ROULE ELECTRONICS RL R17, RL R10A, RL R40 Users Manual

PIR ALARM KIT
RL-9830G4
Version1.0
Package Contents
ON
OFF
PIR alarm
(Main unit)
*2
Before using the product, please remove the insulation sheets from all transmitters. 2 screws together with 2 plastic plugs (for installing the main unit brackets) and 4 3M stickers(for door/window magnetic sensors)are included in each screw pack. The main unit includes a receiver module and a transmitter module inside.
Remote key fob
(Transmitter)
*2
PIR alarm (Main unit)
Speaker
Indicator light
PIR sensing area
Door/window
magnetic sensor
(Transmitter)
*4
Code button
Vibration alarm
(Transmitter,
3M stickers
included)
*2
Alarm indicator: When the main unit sounds an alarm, the light will flash quickly along with the alarm sound. Low battery indicator: When the batteries installed in the main unit reach a low level, i.e., less than 3.3V, the light will flash slowly (time interval of 3 seconds). Please replace batteries immediately when the low battery indicator light flashes.
Bracket
*2
Screw pack
Paring the Transmitters to the PIR Alarm
30s
A
A
-
-
+
BATTERY
BATTERY
BATTERY
+
+
-
1. Insert batteries to
the PIR alarms A and B.
User manual
*2
*1
B
-
-
+
BATTERY
BATTERY
BATTERY
+
+
-
2. For the PIR alarm A,
press the Code button for 3 seconds by inserting the screwdriver. A single "Beep" will be heard.
d
A
3. Release the screwdriver and within 30 seconds:
3a. Remote key fob: press any button 3b. Vibration alarm: slide the switch to "RF" and
then knock on the vibration alarm. It will send a wireless signal to the main unit.
a
ON
OFF
A
c
B
3c. Door/window magnetic sensor: Separate the magnetic contact from the alarm, the red indicator light will be on. 3d. PIR alarm B: press the Code button by inserting the screwdriver.
Also pair the transmitters to the PIR alarm B by following the steps above. You can add up to 32 transmitters to each PIR alarm.
4. The PIR alarm A will
give one "Beep" tone to indicate that the signal is received.
5. Press the Code button
again for 3 seconds by inserting the screwdriver. Two "Beep" tones will be heard.
A
b
A
6. Release the screwdriver,
pairing is now completed.
Remote key fob (Transmitter)
Arm button
Disarm button
OFF
Front view
Side view
Vibration alarm (Transmitter)
Speaker
RF Off RF+Alarm
Battery Compartment
1
Door/window magnetic sensor
(Transmitter)
Indicator light
Once paired to the main unit and in
the ARM mode if the magnetic AWAY mode HOME mode
Magnetic contact
Once paired to the main unit and in the ARM mode if the vibration alarm is triggered by a vibration, it will sound or send a wireless signal to the main unit. The main unit will sound when it receives the wireless signal from the vibration alarm. To disarm the alarm press the OFF button on the remote key fob.
Switch Operation:
OFF: Power off. RF: When triggered, it itself will not sound but will send a wireless signal to
the main unit. RF+ALARM: Three "Beep" tones will be heard when powered. When triggered, it will send a wireless signal to the main unit and after 2 seconds it itself will also sound for 8 seconds.
contact is separated from the
door/window sensor the alarm will
sound. To disarm the alarm press the
OFF button on the remote key fob.
Clearing Code
-
-
+
BATTERY
BATTERY
BATTERY
+
+
-
Installation
PIR alarm
Firstly, install the bracket and attach the main unit to the angle of the PIR alarm bracket and adjust the angle accordingly.
The PIR alarm A or B Press and hold the Code button by inserting the screwdriver (as above) before installing the batteries. Insert batteries you will hear two "Beep" tones that will confirm that the clearing code has been successful.
NOTE: The above will clear the code for all paired transmitters.
2-6M
The detecting range and angle of the PIR alarm
90°
2
CR2032
Door/window magnetic sensor
1. Open the battery compartment to insert a battery.
2. Fix the unit on the door or window by using a 3M sticker.
Arming/Disarming via Remote Key Fobs
Remote Key Fob: Press "ON" to ARM the unit, "OFF" to DISARM the unit.
Switch: " " into the AWAY mode while " " is the HOME mode.
1) AWAY Mode
Slide the switch to " " AWAY mode and press "ON", the main unit will give one "Beep" tone. After 30 seconds, the unit will enter into the ARM mode. If the door/window installed with the magnetic sensor is opened or the window installed with the vibration alarm is knocked or someone enters the property and the PIR alarm detects the intrusion, the PIR alarm will sound. To disarm the alarm press "OFF" on the remote key fob. When the PIR alarm receives the DISARM command,it will give two "Beep" tones and if it is in the ALARM status, the sound will be immediately turned off.
2) HOME Mode
For use in the HOME mode you must use the door/window magnetic sensors or the vibration alarm. Slide the switch to " " HOME mode and press "ON", the main unit will give one "Beep" tone. After 30 seconds, the unit will enter into the ARM mode. NOTE: In this mode the PIR sensor is disabled, therefore, your windows and doors are protected by magnetic sensors or vibration alarms whilst you are in the property. If a door or window is opened or knocked, the alarm will sound. To disarm the alarm press "OFF" on the remote key fob.
NOTE: The description above is only for the system with one PIR alarm. If you want 2 PIR alarms in the system and want them to be interlinked, they both must be paired to each other and be paired to the transmitters respectively. After, you must arm 2 PIR alarms with the remote key fob. Once armed, 2 PIR alarms will sound if any transmitter is triggered. In the AWAY mode, no matter which PIR alarm detects human movements, 2 PIR alarms will sound.
Remote key fobs can only turn off the sound of the PIR alarm. The sound of the vibration alarm, however, will be auto stopped after 8 seconds.
Vibration Alarm
1. Open the battery compartment to insert batteries.
2. Fix the unit on the window by using a 3M sticker.
LR44
LR44 LR44
Technical Specifications
Remote key fob
(Transmitter)
Working Voltage DC 3.0V(CR2032) DC 3.0V(CR2032) 4.5 V (3x battery LR44)
Standby Current <2uA
Working Current
Working Frequency
Working Distance >30m(no barrier)
Alarm Volume
Time Interval of Each Vibration
(30cm)
12mA
433.92MHz±250KHz 433.92MHz±250KHz 433.92MHz±250KHz
/ / >95dB
/ /
Door/window magnetic sensor
(Transmitter)
10uA
15mA
≥80m (no barrier) ≥80m (no barrier)
Vibration alarm
(Transmitter)
6uA
RF: <15mA RF+ALARM: <100mA
5s
Tips
Recommended installation height: 1.6±0.3m, adjust the installation angle to face downward. Do not install the product in direct sunlight or close to a radiator or heat source. The detection range of the PIR alarm may vary slightly due to different environments. Do not attempt to repair this product, please return to your retailer According to the co-channel interference principle, the receive distance may be affected if a strong interference signal exists within the using area. If a car is travelling nearby, the receive distance may be affected as well.. Remove batteries if the product is not in use for a long time and dispose the batteries according to the local laws and regulations.
Troubleshooting
1. The main unit false alarms.
Check if any animals are in the vicinity of the PIR sensor, During warm weather moving shadows may also activate the alarm. Make sure that the PIR sensor is not positioned near a radiator or heat source. Check if any appliances within the property are emitting a strong electromagnetic field near the door/window magnetic contact. Strong electromagnetic fields may cause the door/window magnetic contact to false alarm.
2. The main unit cannot receive the signal sent from the transmitter (remote key fob or door/window
magnetic contact). Check if the pairing between the transmitter and the main unit has been successful. If the pairing was successful, check the battery voltage for both the main unit and the transmitter. Low voltage will cause the product to fail.
3. When the PIR alarm detects movement, however, no alarm sounds.
Check if the low battery indicator is flashing (please replace batteries immediately). If the unit is armed and set in the HOME mode and the PIR sensor detects an intrusion the alarm will not sound. The PIR is disabled in the HOME mode. Check if the main unit is installed correctly.
PIR alarm (Main unit)
Working Voltage DC 4.5V(1.5V/AA/LR6*3)
Working Current 100mA
Standby Current 0.5mA
Low Voltage Indicator ≤3.3V
Alarm Volume ≥100dB(30cm)
Wireless Frequency 433.92MHz±250KHz
Infrared Detective Distance 6m
Infrared Alarm Angle 100°
Arm Mode Arming delays 30s each time
Alarm Mode Alarm once triggered
Alarm Time 30s each time
Wireless Distance ≥30m (no barrier)
3
FCC Statement
Warning: Changes or modifications to this unit not expressly approved by theparty responsible
for compliance could void the user's authority to operate theequipment.
NOTE: This equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits aredesigned to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses and can radiate radiofrequency energy and, if not installed and used in accordance with theinstructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particularinstallation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning the equipment off andon, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to whichthe receiver is connected. Consult the dealer or an experienced radio/TV technician for help
The device must not be co-located or operating in conjunction with any other antenna or transmitter.
Thi s de vice co mp lie s wi th Pa rt 1 5 of th e FC C Rul es .Op er ation i s su bje ct t o the
fol lowi ng two co ndi tions :
(1) this d evice m ay n ot ca us e har mf ul in te rfe re nce, an d
(2) thi s devic e mu st ac ce pt an y in ter fe ren ce r ece iv ed, inc lu din g in ter fe ren ce t hat
may ca use un des ired opera tio n.
4
Loading...