Roto E-Tec DoorDrive Installation, Maintenance And Operation Instructions

Page 1
Window and Door Technology
Roto E-Tec DoorDrive
The concealed swing door drive for doors
Installation, maintenance and operation instructions for timber and aluminium doors
Page 2
Imprint
Copyright: April 2013 Roto Frank AG Wilhelm-Frank-Platz 1 70771 Leinfelden-Echterdingen, Germany Telephone +49 711 7598 0 Fax +49 711 7598 253 info@roto-frank.com www.roto-frank.com
Page 3
General information
Contents
General information
Safety
System architecture
Information on these instructions .................................................... 5
Responsibility of the target groups .................................................. 6
Instruction obligation of the target groups ......................................7
Explanation of the safety instruction symbols .................................8
Limitation of liability ........................................................................ 9
Stipulated application .................................................................... 10
Handling electrical equipment ....................................................... 11
Risks on closing edges and moving components ........................... 11
Residual risk ................................................................................. 11
Overview ....................................................................................... 12
Parts list ........................................................................................ 13
Scope of delivery for Roto E-Tec DoorDrive ................................... 13
Installation
Wiring
Commissioning
Permissible performance characteristics ....................................... 14
Overload protection ....................................................................... 14
Installation explanation .................................................................. 15
Preparation .................................................................................... 16
System overview ........................................................................... 17
Required fastening means ............................................................. 18
Installation steps ........................................................................... 19
Connection diagram for Eneo C / CC with Roto E-Tec DoorDrive ....26
Permissible cable length ................................................................ 27
Initial operation steps .................................................................... 28
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 3
Page 4
General information
Contents
Optional settings
Feedback and errors
Push to close/Push to open operating mode .................................. 31
Control inputs ................................................................................ 32
Programmable output .................................................................... 33
Authorization period ...................................................................... 34
Acoustic signal transmitter, hold-open period ............................... 35
Crush guard, reversing when closing ............................................. 36
Fault memory, special functions .................................................... 37
Signal sequence meaning .............................................................. 38
Feedback ....................................................................................... 38
Troubleshooting ............................................................................. 39
Errors ............................................................................................. 39
Maintenance
Risk assessment
Disposal
Door functions ............................................................................... 43
Structural surroundings ................................................................. 44
Lubrication ..................................................................................... 44
General details ............................................................................... 45
Inspect possible hazardous locations on
automatic Turn-Only sash doors .................................................... 46
Inspect and check possible hazardous locations and protection
measures as per DIN EN 16005 ..................................................... 47
Final comments ............................................................................. 49
....................................................................................................... 50
4 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 5
General information
Information on this manual
This manual contains important information and instructions for safe operation.
This manual also contains binding guidelines to ensure that the duty to instruct is observed through to the end-user.
The information and instructions in this manual refer to the Roto E-Tec DoorDrive products.
This manual should be stored in such a manner that it can be quickly used, if needed.
Additional markings
The following signs are used in this manual to highlight handling directives, results, lists, references and other elements:
Marking Explanation
Drill holes
1
1.
p. 12
Refer to page12 (Cross) reference in the text
Hardware components
Action steps
First level of hierarchy in a list
Unordered list (second level of hierarchy)
(Cross) reference in tables
The figures show DIN right-hand versions. All dimensions stated in mm. Otherwise the values are indicated.
Copyright protection
The contents of this manual are protected by copyright. It is permissible to use these contents when working with the hardware. Any usage over and beyond this is not permitted without written permission from the manufac­turer.
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 5
Page 6
General information
Responsibility of target groups
The information in this document is intended for the following target groups:
Hardware dealers
The “hardware dealers” target group includes all companies/persons who purchase hardware from the hardware manufacturer to resell it without the hardware being modified or subjected to further work.
Door manufacturers
The “door manufacturers” target group includes all companies/persons who purchase hardware from the hardware manufacturer or the hardware dealer and install it into doors.
Building element dealers/installation companies
The “building element dealers” target group includes all companies/ persons who purchase doors from the door manufacturer in order to sell these on and to install them into a building development without modifying them.
The “installation company” target group includes all companies/persons who purchase doors from the door manufacturer or the building element dealer in order to install them into a building development without modi­fying them.
Builders
The “builder” target group includes all companies/persons who order doors for installation into their building project.
End-users
The “end-users” target group includes all persons who operate the installed doors.
6 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 7
General information
Instruction obligation of target groups
Responsibility of hardware dealer
The hardware dealer must forward the following documents to the door manufacturer: – Catalogue – Installation, maintenance and operation instructions
Responsibility of the door manufacturer
The door manufacturer and the customer must conduct a risk assessment (refer to page 45 - 49) in accordance with DIN EN 16005: – Installation, maintenance and operation instructions
The manufacturer must ensure that the end-user is provided with the docu­ments and information intended for them, in printed format.
Responsibility of specialised dealer / installation company
The specialised dealer must forward the following documents to the builder, even when a subcontractor (installation company) is acting as an intermediary: – Maintenance and operating instructions (with the focus on hardware)
The specialised dealer and the customer must conduct a risk assessment (refer to page 45 – 49) in accordance with DIN EN 16005.
Responsibility of builder
The builder must forward the following documents to the end user: – Maintenance and operating instructions (with the focus on hardware) – Specifications/information for end-users (VHBE)
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 7
Page 8
General information
Explanation of safety instruction symbols
In this manual, safety information is indicated by a symbol. The safety information is introduced by a key word that indicates the severity of the danger.
DANGER!
This combination of symbol and signal word indicates an immi­nently hazardous situation, which may lead to fatality or serious injuries, if it is not avoided.
WARNING!
This combination of symbol and signal word indicates a potentially hazardous situation, that may lead to fatality or serious injuries, if it is not avoided.
CAUTION!
This combination of symbol and signal word indicates a potentially hazardous situation, which may lead to minor or light injuries, if it is not avoided.
NOTE!
This symbol and signal word indicate a potentially hazardous situation, which may lead to property or environmental damage if it is not avoided.
8 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 9
General information
Limitation of liability
All the details and information in this document have been compiled based on the relevant standards and regulations, and state of the art development, along with many years of knowledge and experience.
The hardware manufacturer shall not accept liability for damage resulting from: – Failure to comply with this document and all product-specific docu-
ments and related applicable directives (refer to the chapters on Safety and Stipulated Use).
– Non-stipulated use/misuse
(refer to the chapters on Safety and Stipulated Use).
– Inadequate invitation to tender, failure to comply with the installation
instructions. – Forced opening / closing of the door. – Increased soiling.
Claims by third parties against the hardware manufacturer on the ground of damages resulting from misuse or failure to follow the instruction obligation on the part of the hardware dealer, the door manufacturer, and of the specialised dealer or the builder are transferred accordingly.
The undertakings agreed in the delivery contract, the general terms and conditions, the hardware manufacturer’s delivery conditions, and the legal regulations applicable at the time of concluding a contract are effective.
The warranty covers original Roto components only.
Subject to technical modifications conducted as part of the improvement process for performance characteristics and further development.
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 9
Page 10
Safety
Stipulated use
Roto E-Tec DoorDrive – Is an electromechanical swing door drive – It is used solely for opening and closing doors with a sash weight up to a
max.120 kg
– It has an operating voltage of 12 V – Fulfils the low-energy requirements of DIN EN 16005 – Is not suitable for use in escape routes and with fire protection doors Roto E-Tec DoorDrive is an aid which closes the door, but which does not lock it. The swing door drive is therefore not a theft- deterrent device and as such it does not absolve the user from his/her obligation to lock the door using the door lock.
Certification of the door system as per DIN EN 16005 is only valid with
power supply units certified in accordance with EN60335.
Stipulated use also includes adhering to all the specifications in the product-specific documents, such as:
– These installation, maintenance and operation instructions – Product catalogues – Information and specifications of the profile manufacturer (e.g. light metal
profiles etc.)
– The valid national laws and directives
Any type of use that goes beyond or differs from the stipulated use shall be regarded as misuse.
WARNING! Danger from misuse, improper installation and improper initial operation
Misuse and incorrect installation of hardware can result in hazardous situations. – Never use combinations that have not been approved by the
hardware manufacturer.
– Never use accessories that are not original products or
that have not been approved by the hardware manufacturer.
– Only those control elements, settings or procedures described in
this documentation should be used. (Control elements, settings or procedures that are not described in this documenta­tion may cause electric shocks, hazards through electrical volt­ages / currents and/or hazards through mechanical processes.)
The following safety instructions are in accordance with DINEN16005,
which regulates the safety specifications pertaining to automatic door systems as per the Machinery Directive (2006 / 42 / EG).
Avoidance of any hazard is always preferable to securing the hazard. The door equipped with Roto E-Tec DoorDrive is driven by a so-called low­energy drive. In other words, the energy of the automatically-moved doors is not any more than 1.6 Joules. This amount of energy is deemed to be non-critical for a group of users that is familiar with the operating principle of the driven door.
10 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 11
Safety
WARNING! Do not let children play with the regulation/control equipment.
Keep the remote control unit out of the reach of children.
WARNING! Handling electrical equipment
– All work on electrical systems may be performed by electrics
specialists (electricians) only.
– Never insert metal objects into the Roto E-Tec DoorDrive
openings, otherwise there is a risk of electric shock.
– If the Roto E-Tec DoorDrive is in mounted into a metallic door
sash, then the door leaf has to be properly grounded.
NOTE! Professional installation and diligent maintenance are central components of door reliability and safety.
Adjacent closing edge
Opposite closing
edge
Primary closing
edge
A professional installation and diligent maintenance are central components of door reliability and safety. In the information and examples listed here every attempt has been made to take a variety of the practical instances into consideration. Nevertheless no warranty can be given here for their completeness. If you are interested in any additional information, please contact your Roto processor.
Hazards on closing edges and moving components
The safety instructions should highlight the possible hazard points on power-operated doors, and show the affected safeguards or design requirements.
DANGER!
– There is a risk of crushing, shearing, bumping and pulling-in on
the various closing edges on the automatic doors.
– There is a risk of crushing and shearing on the moving compo-
nents of the door drive and the linkage system.
Residual risk
Depending on the structural conditions, door variants and safeguard options, residual hazards (e.g. crushing, force-limited impacts) cannot be ruled out.
The hazard points that exist on every (even manually driven) Turn-Only sash door at the adjacent closing edge are generally known to all door users. This cannot be influenced by the swing door drive manufacturer.
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 11
Page 12
System architecture
Overview
10
20
E-Tec control unit
Roto E-Tec DoorDrive
30
Cable type SD
40
Cable type S
Cable junction connection
12 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 13
System architecture
Parts list
Scope of delivery for Roto E-Tec DoorDrive
40
30
Scope of delivery
Pos. Designation Material no.
10
Roto E-Tec DoorDrive 637922
20
Roto E-Tec DoorDrive control unit 637923
30
Cable type SD length 1.5 m 637924
40
Cable type S length 1 m 637957 Pluggable cable junction, 8-pin (not depicted) 637956
Power supply unit 13 V for Roto E-Tec DoorDrive
637955
(not depicted)
Counterplate 60 x 55 x 5 mm incl. screws
637958
(not depicted)
20
10
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 13
Page 14
System architecture
Permissible performance characteristics
Power supply unit INPOTRON PSU-4351-09
Door sash weight Max. 120 kg
Door material Aluminium and timber
Door panel Interior or concealed sash
Sash width Min. 700 to 1200 mm
Sash height Min. 1600 to 2350 mm
Door opening angle Max. 105°
Number of door hinges Min. 3 pieces (2 x at top / 1 x at bottom) depending
Cable junction Pluggable cable junction, 8 pin
Overload protection
To avoid any damage to the door and/or the swing door drive through slam­ming through extreme manual force or wind power, the swing door drive is equipped with a brake function.
on type, poss. 4
NOTE!
At least 3 door hinges (2 x at top / 1 x at bottom) must be used. The door hinges must fulfil the Class 14 requirements in accordance with EN 1935.
If the door is moved at too fast a speed, the swing door drive is actively braked until the door comes almost to a standstill again.
14 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 15
System architecture
Installation explanation
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 15
Page 16
Installation
Installation steps overview
1.
Preparing profiles (milling, drilling)
2.
Routing lines in profile
3.
Installing swing door drive
4.
Installing control electronics
5.
Installing door
6.
Conducting function test
7.
Connecting power supply unit and additional peripherals / house wiring (electrician)
Steps 1 to 4 are conducted at the factory. Steps 5 to 7 are conducted at the building site or the door installation location.
Preparation
When installing and positioning the door drive and its components in the door system, process the door profiles in line with the drilling and milling drawing available from Roto.
If the dimensions and tolerances in the drilling and milling drawing are not complied with, fault-free operation of the door drive cannot be guaranteed. Installation problems may also occur.
Mill out corner connector as far as required only. Make a corresponding corner bracket for reinforcement in the clearance.
Set the control to match the Roto configuration. (Refer to page 31). This programming step is best performed in advance, e.g. at the factory.
NOTE! Installation sequence
Install the wiring harness in the door sash before inserting the door panel. The drill holes and milling must be conducted in accordance with
the DINISO2768-mK general tolerance.
NOTE!
Precautions should be taken when installing the door to ensure that any inadvertent opening beyond the maximum opening width is avoided, as otherwise the swing door drive could be damaged. An end stop must be fitted for the maximum opening position on site to ensure that the maximum opening angle (< 105° system specific) is not exceeded.
NOTE!
Sufficient clearance must be given between the frame and the sash at each point, as otherwise reliable closing and opening of the sash cannot be assured.
NOTE!
The sealing systems used must be capable of being sufficiently compressed to ensure that the sash is reliably closed.
16 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 17
Installation
System overview
The following drawing shows an overall view of the system.
Counterplate
E-Tec control unit
Roto E-Tec DoorDrive
Cable type SD
Cable type S
Cable junction connection
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 17
Page 18
Installation
Required fastening means
20 20 20 20 20 20
40
10
50
30
60
Fastening means
Pos. Pcs Designation Description
2)
10
1 Counterplate t = 5 mm 60 x 50 x 5
20
14 Countersunk self-drilling screw
(for aluminium fastening)
1)
20a
14 Spax countersunk screws with Torx TX20 4 x 40
2)
30
4 Allen screw DIN 6912 – M5 x 60 – 8.8
2)
40
4 Washer DIN 125 – A 5.3 – 140 HV
2)
50
1 Fillister head screw DIN 7504 N 3.5 x 32
60
2 Countersunk self-drilling screw DIN 7504 P 4.2 x 32
1) To fasten the door drive in a timber door 20 is replaced by
20a
.
DIN 7982 C 3.9 x 19
60
NOTE!
Position 10, 30, 40 and 50 are included in the scope of supply for
637958.
18 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 19
Installation
Installation steps
Pull cable type SD with the free end at the top
1.
through the milled recesses in the door sash into the interior (door panel). Pull cable type SD in far enough until a protrusion of approx. 400 mm still projects beyond the upper milled recess.
Route cable type SD into the glazing rebate up to
2.
the milled recess for the electronic unit. Ensure that the cable here has sufficiently large bending radii. Alternatively, the cable can also be routed into the profile chamber. To do this, the cable must however have been inserted before the corner connector is made.
Route the cable type SD through the bore in the
3.
glazing rebate into the profile chamber. Seal the drill holes to the glazing rebate after routing the cable with vapour diffusion-proof adhesive tape.
Drill hole
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 19
Page 20
Installation
Installation steps
Elongated hole 1
Elongated hole 2
Elongated hole 1
Elongated hole 2
Route cable type S through the specified elongated
4.
hole 1 into the glazing rebate and then through elongated hole 2 back into the profile chamber. Seal the drill holes after connecting the electronic unit using vapour diffusion-proof adhesive tape.
To install the door drive into the door sash, the
5.
assembly must be separated. To do so, release the fillister head screw and remove
thethreaded bushing.
Open door sash to max. 90° and bolt the angle
6.
bracket using four Allen screws (
40
washers (
Page 18) into the specified drill holes in
30
Page 18) and
the frame profile to the counterplate (tightening torque max. 3 Nm). When positioning the angle bracket make sure that the Allen screws
30
(
Page 18) are located in the centre of the elon­gated holes of the angle bracket. The elongated holes can be used for making positioning correc­tions if the door sash should sag.
20 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 21
Installation
Installation steps
Secure the counterplate using the self-drilling screw
7.
50
(
Page 18).
Fasten plug-and-socket connection between cable
8.
type SD and door drive connector.
Apply light coating of grease to complete circumfer-
9.
ence of guide tube on flexible bearing on both sides (1+2) using Klübersynth LI 44-22 or Berulub FR 43
1
2
Insert door drive from above into milled recess of door sash. Make sure when inserting, that the the cable type SD is not damaged or kinked.
Screw the door drive from the top using 14 fixing
10.
screws (
20
Page 18) onto the door sash.
(Tightening torque max. 1.4 Nm)
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 21
Page 22
Installation
Installation steps
Manually pull the coupling rod approx.80 mm out of
11.
the door sash. Then, by moving the door sash, join the coupling rod with the angle bracket. When joining, make sure that the system remains free of tension and that the gap widths between the coupling rod and the angle bracket are spaced equally apart.
Slide the threaded bushing from above into the
12.
coupling rod and through the angle bracket. Fasten this in place using the fillister head screw. When bolting together, press with the finger from above onto the threaded bushing. (Tightening torque max. 2.5 Nm)
The two plug-and-socket connectors on X1 and X2
13.
cannot be interchanged, and they have reverse­polarity protection. Therefore, make sure that they are wired correctly.
– Connect to X1 cable type SD to Roto E-Tec
DoorDrive.
– On X2, connect cable type S to the cable junction.
22 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 23
Installation
Installation steps
Strip the required wires (refer to Table1 or sketch on
14.
left) on cable type SD to 9 mm. Connect the stripped
wires to the plug-and-socket connectorX1 denoted
by the white dot, as per Table 1. The contacts are numbered at the side on the connector The wires are coloured.
NOTE!
When shortening the cable it is advisable to strip the insulation for an area of at least 5 cm, because the cable in the stripped insulation area is flexible, this in turn ena­bles the excess length required in the profile to be simply cleared away.
Table 1: Assignment of plug-and-socket connector X1 to the door /to the spindle drive on cable harness 1
Contact Description Abbreviation Wire colour
1
Motor + M+ Red
2
Motor – M– Black
3
Hall GND HGND Violet
4
5
Hall Vcc HVCC Yellow
6
7
Hall Speed 2 HS2 Green
8
9
Hall Speed 1 HS1 Blue
10
11
12
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 23
Page 24
Installation
Installation steps
Connect the second plug-and-socket connector X2
15.
to cable type S as per Table 2 (similar to first plug­and-socket connector).
Connect cable – using screwdriver (2.5 x 0.4 mm).
Table 2: Assignment of plug-and-socket connector X2 to house wiring / lock to cable type SD
Contact Description Abbreviation Wire colour
1
Lock signal SSIG
2
Lock ground SGND
3
Lock supply S+
4
Lock feedback SRM
5
Driver output OFF
6
Antenna ANT
7
Signal 1 IN1 Pink
8
Signal 1 AC IN1AC
9
Signal 2 / IN2 Blue
10
Signal 3 IN3
11
Supply voltage 12V Red
12
Ground GND Black
To jam the plug-and-socket connector in place, insert a screwdriver at an incline onto the outer visible spring in the terminal strip. The screwdriver opens the spring contact and sticks there in place (it can then be released). Insert the wire and remove the screwdriver again. The contact numbering is printed on to the side. The two connectors are coded and they cannot be interchanged. Therefore, when connecting the lines make sure that the correct plug-and-socket connector has been selected.
24 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 25
Installation
Installation steps
60
Join the two connectors to the control unit.
16.
Insert the electronic wiring for the door drive into the
17.
designated milled recess in the door sash. When doing so make sure that the cable is not kinked or damaged. Then, using the two self-drilling screws (
60
Page 18),
connect the door drive electronics to the door frame.
CAUTION!
The opening for programming the control system must be down.
NOTE!
When installing the door, precautions have to be taken to ensure that any unintended open­ing over and beyond the maximum opening angle is avoided – risk of damage to the swing door drive!
– The maximum opening angle (<105°) must
not be exceeded.
– The specified position of the retaining
bracket relative to the swing door drive must be maintained. The coupling rod must not be tensioned when it is installed.
– The specified wiring must be maintained
exactly as stipulated.
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 25
Page 26
Wiring
Connection diagram for Eneo C / CC with Roto E-Tec DoorDrive
Roto E-Tec DoorDriveDoorSafe Eneo
Black
Access control
system
Finger scan,
Bluetooth,
PIN code keyboard
Plug-in cable junction
box
Inside: Push-button
JST plug-
and-socket
connector
White
K1b
Pink
Black
Grey
K1a
Yellow
IN2
GND
Green
Green
+24V
Brown
IN1
White
Plug-and-
socket
connector
Red
Black
Violet
1 2 3
Control unit
7 911
Brown
Green
Yellow
Grey
White
Black Green
Pink
Pink
Blue
Red
1 2 3 4 5 6 1 2 3 4
White
Brown
Green
Yellow
Grey
Pink
Red
Black
Yellow
5
12
Black
Green
Blue
7 9
On the sash side
On the frame side
+ –
Power supply unit for Roto E-Tec DoorDrive
IN: 100-240 V AC
OUT: 13 V DC/120 W
N L
“Open and close door”
“Day/night”
“Close door”
Switch
Outside: Push-button
Two-way intercom system
Signal (e.g. 12 V)
Potential-free contact
NOTE!
If a 24V voltage is applied to terminal 4, the
lock is in the “day operation mode”. If voltage is not applied, the lock is in the “night opera­tion mode“ (optional).
N L
Eneo power supply unit
IN: 100-240 V AC
OUT: 24 V DC/2.5 A
Plug and cable assignment
White: IN1 / Input 1 (OPEN)
Brown: +24 V
Green: GND (24 V)
Yellow: IN2 / Input 2 (day/night)
Blue: Close push-button
Violet: Close push-button
Red: +13
Black: GND (13 V)
–V+V
26 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 27
Wiring
Permissible cable length
13 V
Power supply unit
(Top-hat rail)
Max. 25 m at 2.5 mm2 /
Max. 40 m at 4 mm
2
Connection
socket
BK / GND (13V)
RD / 13V
n
2
/
C
y s t e
m
.
Cable junction
o
D
n
o
t
o
r
r
o
l
S
For reliable operation, including with door blocking and a high load, a power supply line resistance is required from the power supply unit to the cable junction of less
than 0.3 Ω for an output wire.
NOTE! House wiring
To ensure that correct operation is possible the power supply line from the 13 V power supply unit for the control system must fulfil specific requirements. Because of the power transfer involved, a wire cross-section of at least
1.5 mm² is recommended. Orientation is provided here by the illustration.
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 27
Page 28
Initial operation
Initial operation steps
Preparation
1.
Connect Eneo lock
2.
Convert to Roto setting
3.
Teach-in closed position
4.
Teach-in open position
5.
Optional: conduct function test
6.
Set up delivery status
7.
Initial operation is only possible with the INPOTRON PSU-4351-09 power supply unit.
CAUTION!
Initial operation (electrical connection) of the door with a swing door drive may be performed by skilled electrics specialist (electri­cian) only.
Ill. 1
Parameter configuration using DIP switch
Using the DIP switch (Ill. 1) under the rubber plug enables various settings for the door to be made to the electronic circuits on the hinge side.
Select the required configuration and confirm the set value. To do so, press one of the two push-buttons for a programmed remote control or a con­nected operation mechanism (push-button, etc.) for longer than 5 seconds.
Acceptance of the setting is indicated by acoustic feedback. The number of signal tones heard is equivalent to the configured value.
Five short beeps indicate an invalid setting.
Once all the required settings have been made, the DIP switches must be reset to “0” (i.e. “00000000”).
The following settings can be made:
CAUTION!
If one of the eight DIP switches is not set to “0”, electrical control of the swing door drive is not possible.
28 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 29
Initial operation
Preparation
1.
Remove the rubber plug of the elongated hole over the DIP switches using a finger nail or a screwdriver. The DIP switches are now visible, refer to illustration.
1 2 3 4 5 6 7 8
DIP switch
on
Service interface
Illustration of DIP switch position
Control logics
Select DIP switches 1– 4 in required top group. Change DIP switches 5–8 function for top group.
0 = OFF 1 = ON
Prepare power supply unit (Status: switched off). Connect the red wire of the cable harness to the positive output. Connect the black wire to the negative output.
NOTE!
To be conducted by electrics specialist (electrician) only.
The default position for the DIP switch is OFF, this position has to be adopted again following every action.
Illustration of power supply unit with connection terminals
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 29
Page 30
Initial operationInitial operation
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
Connecting multi-point locking system
2.
Connect Eneo C / CC multi-point locking system with the operation mechanism as per the wiring diagram to the power supply units. Switch on power supply units or plug connector into power socket.
Converting to Roto setting
3.
Activate Roto settings. To do so, switch on power for control system and set DIP switches to 1111.1010. Confirm by pressing one of the operation mechanisms for 3 seconds.
NOTE!
Operation mechanisms are Eneo hand-held transmitters (they have to be programmed beforehand, refer to Eneo C / CC IMO_190 installation instructions or refer to page 26).
Teaching-in closed position
4.
Set DIP switches to 1111.0001. Close door and use hand to keep it closed. Press an operation mechanism for 5 seconds until acoustic feedback is issued indicating the action was successful.
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
NOTE!
Use hand to keep door closed until the acoustic feedback is heard.
Teaching-in open position
5.
Manually open the door to gain access to the DIP switches. Set the DIP switches to 1111.0010, move door to the required open position and hold it there. Press an operation mechanism for 3 seconds until acoustic feedback is issued indicating the action was successful.
NOTE!
A fault reason can also be an error in step 4. Set the DIP switches to position 0000.0000.
Conducting optional function test
6.
Check closing and opening of the door to match the selected settings or configurations. The operation mechanism should be able to initiate the door opening and door closing process.
Setting up delivery status
8.
Set up required delivery status. For example:
Disconnect the power supply unit from the mains, detach connection
to the door
Insert rubber plug into cover openingStow away the remote controls and supply unit
30 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 31
Optional settings
Operating mode, Push to close/Push to open
A service dongle is required for certain individual settings (denoted by * in the following text), which only the door manufacturer may make. Plug the service dongle onto the service connector. The correct function is indicated by the LED on the service dongle lighting up. All the other settings can be made by the end user.
ON
Illustration of service dongle, the tab acts as a reverse-polarity protection
1 2 3 4 5 6 7 8
Service interface illustration
Service interface
Roto settings are available in the tables in bold. These default values are replaced during initial operation in step 3.
Individual setting
NOTE!
All settings denoted by * require a service dongle.
1. Operating mode
Setting operating mode on DIP switches 1 – 4 = 0000
DIP switch Description Feedback signal Personal setting
0 0 0 0 Normal operation Basic setting
0 0 0 0
1 1 1 1 Change to
parameterisation mode
= Activate serial
interface
2. Push to close / Push to open
Push to close or Push to open can be set to suit requirements.
In this function several options can be defined for the parameter as sepa­rate settings can be made for “Push to close / Push to open”. Push to open means that the door is automatically opened by approx. 10° following a manual impulse. Push to close is the same except the door closes here instead of opening.
Setting general functionality / comfort on DIP switches 1– 4 = 0001
DIP switch Description Feedback signal Personal setting
0 0 Feedback on current status
0 0
0 1 Push to close OFF 1 1 0 Push to close ON 2
0 0 Feedback on current status
0 0 0 1
0 1
0 1 Push to open OFF 1 1 0 Push to open ON 2
0 0 Feedback on current status*
1 0
0 1 1
* Placeholder
1 0 2
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 31
Page 32
Optional settings
Actuation inputs
3. Actuation inputs*
The door is equipped with three different actuation inputs to which various operation mechanisms (remote control, card reader, Bluetooth receiver, area push-button, etc.) can be connected to which the door will respond.
Various system response modes for each connected operation mechanism can be selected: – Direct actuation: Door opens/closes immediately – Authorisation: Connected operation mechanisms are processed
as authorisation – the system is activated for a programmable period (enabled, authorised). Door movement is not actuated without other operation mechanisms.
– Authorised actuation: Connected operation mechanisms are only
accepted as valid operation when authorisation
has been issued. – Immediate opening: Door opens or remains open – Immediate closing: Door closes or remains closed – Authorised opening: Door only opens when authorisation has been
issued or it remains open – Authorised closing: Door only closes when authorisation has been
issued or it remains closed
Actuation input E1:
DIP switch Description Feedback signal Personal setting
0 0 0 0 Feedback on current setting
0 0 0 1 E1 not assigned 1
0 0 1 0 E1 direct actuation 2
0 0 1 1 E1 authorised actuation 3
0 0 10
0 1 0 0 E1 authorisation 4 0 1 0 1 E1 direct actuation 5
0 1 1 0 E1 direct closing 6
0 1 1 1 E1 authorised opening 7
1 0 0 0 E1 authorised closing 8
Actuation input E2:
DIP switch Description Feedback signal Personal setting
0 0 0 0 Feedback on current setting
0 0 0 1 E2 not assigned 1
0 0 1 0 E2 direct actuation 2
0 0 1 1 E2 authorised actuation 3
0 0 11
0 1 0 0 E2 authorisation 4
0 1 0 1 E2 direct actuation 5 0 1 1 0 E2 direct closing 6
0 1 1 1 E2 authorised opening 7
1 0 0 0 E2 authorised closing 8
Actuation input E3:
DIP switch Description Feedback signal Personal setting
0 0 0 0 Feedback on current setting – 0 0 0 1 E3 not assigned 1
0 0 1 0 E3 direct actuation 2
0 0 1 1 E3 authorised actuation 3
0 1 0 0
0 1 0 0 E3 authorisation 4
0 1 0 1 E3 direct actuation 5
0 1 1 0 E3 direct closing 6
0 1 1 1 E3 authorised opening 7
1 0 0 0 E3 authorised closing 8
32 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 33
Optional settings
Programmable output
4. Programmable output*
The door control is equipped with its own programmable output to which, e.g. the light in the input area is connected and where it can be configured such that it is switched on when the door is opened. A small LED lamp can also be connected, which lights up when authorisation has been issued.
It is also possible to configure the output so that it is only briefly actuated, in other words it flashes on and off briefly or it is permanently activated.
NOTE!
In the standard wiring the signal for the programmable output is not routed out of the door.
DIP switch Description Feedback signal Personal setting
0 0 Feedback on current status
1
2
2
3
2
3
0 1 1 0
0 1 General setting:
Continuous signal as long as
0 0
0 1
1 0
authorisation issued
1 0 General setting:
Continuous signal if not closed
1 1 General setting: Precision setting at bottom 3
0 0 Feedback on current status
0 1 Signal when opening: None 1
1 0 Signal when opening:
Output activated for 0.5 seconds
1 1 Signal when opening:
Output activated as long as actuation issued
0 0 Feedback on current status
0 1 Signal when closing: None 1
1 0 Signal when closing:
Output activated for 0.5 seconds
1 1 Signal when closing:
Output activated as long as actuation issued
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 33
Page 34
Optional settings
Authorisation period
5. Authorisation period
Authorisation means that the door receives a pulse, which indicates to the door that the pulse transducers are authorised to operate the door.
The authorisation period enables the validity of an actuated authorisation to be defined. If the authorised operation mechanism is used, the authorisa­tion is then cancelled. In other words, the operation mechanism has to be authorised again before each usage. The Roto setting for the authorisation period is one minute.
Example: DIP switch set to 01110111 (Roto setting): Following authorisa­tion, the door has to be opened within a period of one minute. Operation during authorisation does not extend the authorisation period, but rather it cancels it. If the door is to then be closed again, authorisation has to be is­sued once more to enable the door to be closed within the one minute pe­riod.
DIP switch Description Feedback signal Personal setting
0 0 Feedback on current setting – 0 1 Authorisation for activation period 1
0 0
1 0 10 seconds 2
1 1 20 seconds 3
0 0 30 seconds 4
0 1 40 seconds 5
0 1
1 0 50 seconds 6
0 1 1 1
1 1 1 minute 7
0 0 1 minute 15 seconds 8
0 1 1 minute 30 seconds 9
1 0
1 0 1 minute 45 seconds 10
1 1 2 minutes 11
0 0 2 minutes 30 seconds 12
0 1 3 minutes 13
1 1
1 0 4 minutes 14
1 1 5 minutes 15
34 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 35
Optional settings
Acoustic signal transmitter, hold-open period
6. Acoustic signal transmitter
This option can be used to set whether you hear a signal or not when you issue the door with a command or not. The “Successful close signal” option enables you to choose whether an acoustic signal should be issued when the door latches shut or not. This is only possible for a lock equipped with feedback.
In the “For start of actuation” setting, you will hear an acoustic signal once at the start of the process. If you choose “as long as the actuation”, this signal is repeated until the process is completed. In other words, until the door is fully opened or closed.
You can also select this setting separately for the opening and closing process.
NOTE! In the event of a fault, feedback is always issued in the form of an acoustic signal.
DIP switch Description Feedback signal Personal setting
0 0 Feedback on current status
0 0
0 1 Signal for successful closing* OFF 1
1 0 Signal for successful closing* ON 2
0 0 Feedback on current status – 0 1 Signal when opening: None 1
1 0 Signal when opening: During start of actua-
0 1
1 0 0 0
1 0
* only effective for lock with feedback
tion
1 1 Signal when opening: As long as actuation
issued
0 0 Feedback on current status
0 1 Signal when closing: None 1 1 0 Signal when closing:
During start of actuation
1 1 Signal when closing: During start of actuation 3
2
3
2
7. Hold-open period
This setting can be used to define the period until the door is automatically closed. This is only valid however, when the door is electrically opened to its end position. The time in the table below indicates the timespan in which the door remains open until an automatic closing process is initiated.
DIP switch Description Feedback signal Personal setting
0 1 1 1
0 0 Feedback on current setting
(as per operation mechanism)
0 1 Automatic closing inactive = Continuous-
0 0
0 1
1 0
1 1
ly open
1 0 After 5 seconds 2
1 1 After 10 seconds 3
0 0 After 20 seconds 4
0 1 After 30 seconds 5
1 0 After 40 seconds 6
1 1 After 1 minute 7
0 0 After 1 minute 15 seconds 8
0 1 After 1 minute 30 seconds 9
1 0 After 1 minute 45 seconds 10
1 1 After 2 minutes 11
0 0 After 2 minutes 30 seconds 12
0 1 After 3 minutes 13
1 0 After 4 minutes 14
1 1 After 5 minutes 15
1
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 35
Page 36
Optional settings
Crush guard, reversing when closing
8. Crush guard
This setting is used to choose the resistance which has to act on the door before it stops an opening or closing process.
DIP switch Description Feedback signal Personal setting
0 0 Feedback on current setting
1 0 1 1 0 0
0 1 Light triggering
(Door stops at slightest resistance)
1 0 Medium = Normal triggering 2
1 1 Heavy triggering
(Door only stops for substantial resistance)
1
3
9. Reversing when closing*
This defines how the door behaves if it is blocked when closing. This is only possible for closing. If the door encounters an obstacle when closing and the reversing function is switched on, it opens again somewhat and - after a brief pause - it tries to close again for a specified number of attempts. If the reversing function is switched off, the door stops at the position that it encountered the obstacle. When opening, the door comes to a standstill without any further attempt to open further.
The number of continuation attempts and the pause time each have a value
that can be configured by Service (factory setting: 4second waiting period, 2continuation attempts). This value cannot be changed by the DIP
switches.
DIP switch Description Feedback signal Personal setting
0 0 Feedback on current setting
0 1 Reversing on, without continuation after
pause
0 0
1 1 0 0
1 0 Reversing on, with continuation after
pause
1 1 Reversing off, without continuation after
pause
0 1 0 0 Reversing off, with continuation after pause 4
1
2
3
36 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 37
Optional settings
Fault memory, special functions
10. Fault memory
The fault memory stores the last 14 system faults. These faults can be called up by corresponding DIP switch settings.
Apart from this, the number of faults can be examined or all faults cleared.
DIP switch Description Feedback signal Personal setting
0 0 Feedback = Number of stored faults
matches number of signals
0 1 1. Display fault memory
0 0
1 0 2. Display fault memory
1 1 3. Display fault memory
0 0 4. Display fault memory
0 1 5. Display fault memory
0 1
1 0 6. Display fault memory
1 1 1 0
1 1 7. Display fault memory
0 0 8. Display fault memory
0 1 9. Display fault memory
1 0
1 0 10. Display fault memory
1 1 11. Display fault memory
0 0 12. Display fault memory
0 1 13. Display fault memory
1 1
1 0 14. Display fault memory
1 1 Acknowledge / delete all faults
Fault codes for faults at position 1-14 (Number of tones issued)
1 RAM fault
2 ROM fault
3 Hall fault
4 Undervoltage fault
5 Excess current fault
10 Fault memory overrun
Fault
11. Special functions
Teach-in of zero position, usually this is the closed door position.
Teach-in of maximum opening angle for the door, the angle which describes how far the door swings open when electrically opened. These two settings must undergo teach-in before being used for the first time!
Similarly, the configurations have to be reset to factory settings.
DIP switch Description Feedback signal Personal setting
0 0 0 1 Programming the zero position
0 0 1 0 Programming the maximum opening angle
1 1 1 1
1 1 1 0 Resetting to factory settings*
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 37
Page 38
Feedback and faults
Signal sequence meaning
Feedback Acknowledgement key: An acknowledgement key is deemed to be any
operation mechanism connected to the control system, which generates a continuous signal or the push-buttons on a previously programmed remote control unit
Continuous sound: Continuous beep
DIP switch: Small slide control. Accessible here in the control system
below the rubber cap.
ESD: Electro Static Discharge
Door electronics: Component on hinge side of door sash, which accom-
modates the control system for the Roto E-Tec DoorDrive.
Encoding: A text / code is used in a secret translation.
Changeable code: Code that changes constantly. A code isvalid once
only. Its use prevents any impermissible access through repetition of a previously used radio signal when opening a door.
Regular beeping: 0.25 s beep and 0.25 s no beep.
(1) (..) (n)
0.25 s
0.25 s
Signal sequence for a fault: 5 shorter beeps (0.1 s beep + 0.2 s no beep).
(1) (2) (3) (4) (5)
0.1 s
0.2 s
1.5 s
Signal sequence for a successful action: 3 longer beeps (0.5 s beep / 0.5 s no beep).
0.5 s
0.5 s
3s
Signal sequence for an active clearance guard: 5 shorter beeps with extended pauses (0.1 s beep + 0.5 s no beep).
(1) (2) (3) (5)
0.1 s
38 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
0.5 s
2.5 s
Page 39
Feedback and faults
Troubleshooting
Errors
The swing door drive complies with a high quality standard and all the nec­essary technical regulations and specifications. Internal safety circuits and external safety circuits managed by the swing door drive are monitored on a cyclical basis. Situations may occur during operation of the Roto E-Tec DoorDrive system that lead to malfunctions.
The swing door drive attempts to determine the reasons for this and to re­spond accordingly. The response will be proportionate to the severity of the reason, and it can lead to a shut down of the automatic swing door drive function. In this instance, the door can be manually opened and closed.
Hardware defects, installation faults and manual operation during the safety test can cause fault messages whereupon the system will changeover into operation. The following option is available to reset fault messages: Mains reset: Switch off the mains voltage for the swing door drive (circuit breaker). A service technician must be notified promptly in the event of a defective or malfunctioning swing door drive.
However, some faults can be checked and rectified without the need for a technician, and the following table should provide assistance here:
Troubleshooting
Problem Possible causes Corrective action Specialist company End-users
Door fails to open automatically, only manual operation possible.
– Control system, power supply
or hand-held transmitter indi­cate a fault.
– Closed or open position not
programmed.
– Switch on power supply unit,
system reset through power supply unit: Deactivate circuit breaker for house wiring for power supply unit for 15 s or contact the specialist company.
– Refer to Initial operation.
– Door jams, may be caused by
door sagging
– Lock unlocks too late.
– Re-adjust hinges or contact
specialist company.
– Contact specialist company.
Door fails to open, beeps in response to open request
– Clearance guard has actuated.
This occurs to prevent any damage through continuous operation.
– Wait for approx. 15 seconds, the
swing door drive can then be used again.
– Acoustic fault signal is issued.
– System reset through power sup-
ply unit: Deactivate power supply unit for 15 seconds, other wise contact the specialist company; programming error was deter­mined, reprogram control system (contact specialist company).
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 39
Page 40
Feedback and faults
Troubleshooting
Troubleshooting
Problem Possible causes Corrective action Specialist company End-users
Door fails to close completely.
– Door jams, may be caused by
door sagging or damaged gasket
– Re-adjust hinges, correct gasket
or contact specialist company.
– Lock sluggish.
– Closed position no longer
programmed
Door opens auto­matically, but only
– “Hold-open period” parameter
incorrectly set. closes after an ex­tended period or not at all.
– Obstacle in door opening area,
which prevents it from closing.
– Door open too far
(open 10 % beyond pro-
grammed open position).
Door reverses
– Sluggishness in system without crushing instance
– Wind load / wind gust
Noise – Joints not greased or dusty.
– Swing door drive damaged.
– Door has sagged
– Grease or contact specialist
company.
– Reprogram closed position or
disconnect system from mains voltage for 15 seconds.
– Adjust hold-open period on
DIP switch.
– Clear opening area.
– Manually close door and check
opening angle, if necessary install door stopper; program new open position (still open)
– Check whether an obstacle can
be detected at the swing door drive and remove it (foreign ob-
ject). – Check door settings. – If necessary, contact specialist
company.
– Adapt crush guard setting using
the DIP switch.
– Grease again with specified
grease, refer to Maintenance.
– Contact specialist company. – Check door setting and readjust
if necessary.
Blocking – Opening area blocked by an
– Clear opening area.
obstacle, blocked by swing door drive (crush guard).
Blocking of swing door drive in
– Swing door drive or actuation
defective. closed position, opening not
– Lock defective.
possible
= To be carried out only by a specialist company
– Contact specialist company,
manual opening remains possible
– Have lock replaced, contact
specialist company.
= Not to be carried out by the end-user; the end-user may not carry out installation work!
= To be carried out either by a specialist company or by the end-user
The DIP switches enable the fault memory to be read out.
40 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 41
Maintenance
Long-term dependability and reliable operation of the automatic door can be assured through regular maintenance.
Have maintenance conducted at least once annually by qualified personnel. Qualified personnel is trained for the following specified work. If, during initial operation, the end user is also given instruction, then the mainte­nance described here can also be performed by the end user. Your Roto specialist dealer will be only too glad to provide you with assistance.
Install certified genuine replacement parts only. Your Roto specialist dealer will provide you with replacement parts.
SAFETY! Danger through moving door sash Risk of injuries through crushing or shearing
– Before performing any mechanical work on the swing door drive,
disconnect it from the power supply, – Secure door against moving, e.g. with a door stopper. – Do not touch the closing edge when checking functions. – Keep children away from the working area.
Property damage through incorrect handling
– The electronic circuit must not come into contact with water. – Do not open door sash any further than 105°.
General maintenance
2
5
3
1
4
76
Maintenance points
1
Angle bracket / coupling rod
2
Fastening of swing door drive
3
Door latch
4
Electronic circuit
5
Power supply unit
6
Fastening of door frame
7
Cable junction
Checking angle bracket and coupling rod
2
1
– The fixing screws of the angle bracket
not be loose.
2
and the coupling rod1 must
– Re-tighten loose screws using screwdriver finger tight. – Check angle bracket and coupling rod for obvious damage and visible
signs of wear.
– Have damaged parts replaced by qualified personnel.
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 41
Page 42
Maintenance
1
2
Checking coupling rod alignment
– The coupling rod must be aligned parallel to the edge of the door. – To readjust, apply light pressure to adapter profile on inner closing edge
1
to release it and remove it, to then enable all the screws to be accessed.
– Release screws
3
– Slide angle bracket so that the coupling rod runs parallel to the upper
2
on angle bracket 3.
edge of the door. – Tighten screws using screwdriver finger tight. Attach adapter profile again.
Checking fastening of swing door drive
The swing door drive is installed into the door leaf below the upper edge of the door. The fastening of the swing door drive can be accessed from above. – The fixing screws of the swing door drive must not be loose. – Re-tighten loose screws using screwdriver finger tight. – Check swing door drive for obvious damage and visible signs of wear. – Have damaged parts replaced by qualified personnel.
Checking door latch for ease of movement
– Door latch must close smoothly. – Remove any coarse soiling. – Clean door latch using clean cloth. – If necessary, also lubricate door latch.
Visually inspecting electronic circuits
2
The electronic circuits are installed in the door leaf. – No soiling or moisture in the electronic circuits. – Clean electronic circuits on outside using clean cloth. – If sealing plug – Re-tighten
1
is damaged or missing, replace it.
2
screws on cover of electronic circuits.
Checking temperature of power supply unit with hand
– When installed, power supply unit is warm to the touch.
1
– If the power supply unit is hot, have the power supply unit checked or
replaced by qualified personnel.
2
– If necessary, switch off the circuit breaker to disconnect the power supply
unit from the mains supply.
Checking mounting of door in masonry
– The door frame is mounted firmly into the masonry. No gaps are visible
between the frame and the masonry. When the door sash is moved the
frame does not move. – Door edges or frame edges are horizontal or vertical. – The closed door sash makes close and even contact with all the closing
edges and the frame. – Check the position of the frame and the door sash using a spirit level. – If necessary, have frame adjusted or mounted again by qualified personnel.
42 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 43
Maintenance
Max. 105°
1
Checking cable junction for firm seating
– The cable junction
1
must be firmly mounted to the frame and to the
door sash.
2
– Tighten fixing screws
2
of cable junction finger tight.
Door functions
Checking programmed door functions
– The opening angle matches the configured value. – The behaviour of the functions corresponds to the settings:
– Crush guard
– Reversing
– Push to close, etc. – The swing door drive operates silently. – If necessary, have door functions set by qualified personnel.
Carrying out manual test run
– Door can be opened and closed without any power supply. – Disconnect swing door drive from mains supply (switch off circuit
breaker). – Open door sash all way to end stop and then close again. – Switch on circuit breaker again.
When next actuated the door closes, irrespective of the current position. – Have faulty behaviour checked and rectified by qualified personnel.
Checking maximum opening angle
– The maximum opening angle for automatic opening is equivalent to the
value in the setting log. – The door sash cannot be opened manually or automatically any further
than105°.
– Check maximum opening angle for automatic and manual operation. Use
an angle protractor or prepared template for the measurement. – Check door hinge or end stop and – if required – have adjusted by quali-
fied personnel. – If necessary, use door stopper to limit opening angle.
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 43
Page 44
Maintenance
Structural surroundings
Min. 25 mm
Max. 8 mm
Avoiding hazardous areas
– The following on-site requirements must be given:
– The distance between the ground and the lower closing edge is less
than 8 mm.
– The distance between the upper edge of the door sash and the room
ceiling is greater than 25 mm.
– There are no obstacles on the ground.
The specifications are dependent on the conducted safety analysis and the individual assessment of residual risks.
– Should you have any queries or if anything is unclear, please contact your
local Roto specialist dealer.
Lubrication
Purchase all lubrication from your Roto specialist dealer. As and when required or at least once a year:
Lubricating door latch and locking cam
– Remove any old, excess lubricant using a dry, lint-free cloth. – Apply one drop of resin-free oil (e.g. Molykote Omnigliss) to moving
parts.
Lubricating door hinge
– Remove any old, excess lubricant using a dry, lint-free cloth. – Apply a drop of oil to the door hinge (e.g. Molykote Omnigliss).
Care
Specialist company End-users
Keep the hardware free from deposits and soiling.
Never use aggressive, acidic cleaning or scouring agents.
Only use mild, pH-neutral cleaning agents in diluted form.
Use a soft cloth only for cleaning.
= To be carried out by a specialist company only
= Not to be carried out by the end-user; the end-user may not carry out installation work!
= To be carried out either by a specialist company or by the end-user
No legal claims can be derived from these recommendations. Application is to be geared to each specific individual case. The door manufacturer must ensure that builders and end-users are made aware of the importance of these maintenance instructions. Roto Frank AG recommends that manufac­turers enter into maintenance agreements with their end-users.
44 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 45
Risk assessment
The door manufacturer (door system installer) shall conduct a risk assessment with the customer (operator) in accordance with DIN EN 16005:
General details
Project (building site / builder) Address
Installation location e.g. ground floor, basement, garage, etc.
Door and swing door drive type Turn-Only sash door with automatic door drive, 1 sash inward opening,
sash overlapping on one or both sides.
Door opening angle Max. 105°
Sash width Min. 700 to 1200 mm
Sash height Min. 1600 to 2350 mm
Door sash weight Max. 120 kg
Automatic door system user group “Private area”
Private area (1 and 2 family home) Regular use for defined and authorised persons, controlled access points, use for instructed and trained persons only.
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 45
Page 46
Risk assessment
Inspecting possible hazardous points on automatic Turn-Only sash doors
Hazard point between adjacent closing edge and ceiling
Hazard point between primary closing edge and opposite closing edge
Hazard point between adjacent closing edge and opposite closing edge/wall
Risk of impact
Risk of crushing
Hazard point between adjacent closing edge and floor
Risk of impact
46 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 47
Risk assessment
Inspecting and checking possible hazard points and protection measures as per DIN EN 16005
Hazard points and protection measures
Hazard point Measure undertaken Remark
Risk of crushing and impact when
Low-energy operation closing the door sash (primary closing edge).
Risk of crushing and impact when opening the door sash (primary closing edge).
Risk of crushing on hinge side (between sash and frame, adjacent closing edge).
Risk of being pulled in between the sash and the flooring (adjacent closing edge).
Low-energy operation
The crushing risk is not influenced by
the swing door drive.
This hazard point is also present on swing doors without swing door drive. It should be assumed that us­ers are familiar with these hazard points from everyday handling of manual doors. Generally, the swing door drive manufacturer has no influ­ence on such hazard points. The risk of crushing – in contrast to the situation on the lock side (= primary closing edge) – is not protected by the low-energy opera­tion. When operating the door, it should be ensured that people are not inadvertently crushed.
Safety distances are maintained. Distance less than 8 mm
(important for floor layer!).
This must be taken into
consideration during the planning phase!
Risk of being pulled in between the
Safety distances are maintained. Distance greater than 25 mm. sash and the ceiling (adjacent closing edge).
This must be taken into
consideration during the planning phase!
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 47
Page 48
Risk assessment
Inspecting and checking possible hazard points and protection measures as per DIN EN 16005
Hazard points and protection measures
Hazard point Measure undertaken Remark
Risk of cutting Use of safety glass in sash and side
part; no sharp edges on door sash,
on door panel or on side part
(combined).
Risk of tripping No obstacles in passage area; no
threshold or step in passage area
(thresholds and platforms ≤ 20 mm).
Risk through weathering, e.g. ice in front of door, etc.
Protection against weather
influences.
Risk though operating error Operation of opening/closing func-
tion for authorised people only
(Operator = “Builder”) instruction of
user group (builder, resident)
This must be taken into
consideration during the planning phase!
The door installation position
is to be chosen to match the planning requirements, e.g.
through installation in the reveal, protection through canopy, not to be installed on weather side, no heavy shadow or direct sunlight.
The door operator is responsible for its safe operation.
48 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 49
Risk assessment
Final comments
Details on residual risks, special functions, changes in use
SAFETY!
The safety instructions must be observed and checked both before and after installation of the door.
The signatory opposite hereby confirms that the hazard points have been adequately secured and considered, and that the auto­matic door system can therefore be put into operation.
Examples of residual risks:
– Steps or stairs in immediate vicinity of door – Door opens too late for configured actuation delay – Impact against primary closing edge of an opening or
closing door sash – Thresholds – Risk of crushing / shearing through rolling levers or
linkage
Address
Place, Date Signature of door system installer
The operator hereby declares that the residual risks are known, that he is familiar with the installation and operating instructions, that he has received appropriate instruction, and that he will ensure that the user group (builder, resident) receives corresponding instructions.
Place, Date Operator signature
Subject to change. Roto E-Tec DoorDrive IMO_294_EN_v0 May 2013 49
Page 50
Disposal
Both the Roto E-Tec DoorDrive and the packaging consist mainly of raw materials that can be recycled. The Roto E-Tec DoorDrive and the accessories should not be disposed of with domestic waste. Make sure that the old device and any accessories are routed to an appropriate disposal process. Ensure that legal, national regulations are complied with here.
50 May 2013 IMO_294_EN_v0 Roto E-Tec DoorDrive Subject to change.
Page 51
Page 52
Roto Frank AG Window and door technology
Wilhelm-Frank-Platz 1 70771 Leinfelden-Echterdingen Germany
Telephone +49 711 7598 0 Telefax +49 711 7598 253 info@roto-frank.com
www.roto-frank.com
MS/B&N Issue date: May 2013. Subject to change. IMO_294_EN_v0
© 2013 Roto Frank AG ® Roto is a registered trademark
From a single source: The optimum hardware system to meet all challenges:
Roto Equipment | Additional technology for windows and doors
Roto Door | Matching hardware technology “for everything to do with doors”
Roto Tilt&Turn | The Tilt&Turn hardware system for windows and balcony doors
Roto Sliding | Hardware systems for large sliding windows and doors
Loading...