3. ADAPTING THE UNIT IN THE CASE OF CHANGING FROM ONE GAS TO ANOTHER
3.1. CHANGING THE INJECTOR
3.3. ADJUSTMENT OF THE PRIMARY AIR
You need to adjust the opening of the air sleeve to dim. D coresponding to the type of gas used ( see
position of the air sleeve, chapter 2.2.3 and the table of adjustment of the burner, chapter 3.7).
3.3.
TABLE FOR ADJUSTMENT OF ONE BURNER
TIGHTENING
RINGS
GAS SUPPLY PIPE
ELBOW OF 90°
ELBOW NUT OF 90°
INJECTOR HOLDER
INJECTOR
AIR INLET
SLEEVE
BURNER
SLEEVE FOR THE
ADJUSTMENT OF
PRIMARY AIR
ELBOW NUT OF 90°
All this information are the property of Rotisol.
Reproduction partial or in totality are prohibited without authority prior written of company Rotisol.
12,59,56,55Presure at the tap for the reduced flow in mbar
7,57,57,57,5Reduced heat flow in KW
1,161,16--Mass flow kg/h
--1,851,59Flow volumein m3/h
452,52,5
Opening of the primary air
« D » in mm (chapitre 2.2.3)
1,822,92,9Diamete rof injector in mm
180200290290injector making
15151515Heat flow in kW
GF 1375
12,59,555Presure at the tap for the reduced flow in mbar
8,58,58,58,5Reduced heat flow in KW
1,321,32--Mass flow kg/h
--2,091,8Flow volumein m3/h
4513,513,5
Opening of the primary air
« D » in mm (chapitre 2.2.3)
1,92,153,13,1Diamete rof injector in mm
190215310310injector making
17171717Heat flow in kW
GF 1675
12,59,56,55Presure at the tap for the reduced flow in mbar
5555Reduced heat flow in KW
0,7760,776--Mass flow kg/h
--1,231,06Flow volumein m3/h
452,52,5
Opening of the primary air
« D » in mm (chapitre 2.2.3)
1,51,652,42,4Diamete rof injector in mm
150165240240injector making
10101010Heat flow in kW
GF 975
G31 under 50 mbarG31 under 37 mbarG25 under 25 mbarG20 under 20 mbarCARACTERISTICSMODEL