Test Box.
The Test Box allows the user to test Remote and Controller batteries under load as well as test Remote Arm/Fire functions, and test Remote receivers. The Test Box also serves as the programming interface between a computer and a RFD Unit.
Figure 9-1 Test Box.
TEST BOX DESCRIPTIONS.
Antenna / Battery Charger Connector:
The Test Box has an Antenna/Battery Charger connector like the Remotes and Controller. Installing an antenna from the system onto the antenna connector turns on the Test Box. The Test Box has an internal battery pack that must be recharged using the system battery charger.
Probe:
166x Series Test Box
12/19/01 Ver 1.4
Battery Test - Standby
The Test Box has a probe that plugs into the Remote or Controller under test. The Test box communicates to the Unit under test through the probe and by using a radio transmitter that is internal to the Test Box. The two leads coming off the probe are for connecting to the Remote binding posts. The firing voltage of the Remote will be measured through these connections.
Serial Connection:
A serial cable connects the Test Box to a computer serial port operating at 1200 baud. The serial cable must be connected to a computer when the Test Box is being used to program Controller and Remote Units. The serial cable may also be used when the Test Box is in the test mode. While in the test mode, the Test Box transmits the information displayed on the Test Box screen out the serial cable. A terminal program such as Hyper Terminal may be set up to capture this information to a file. The file can then be saved and printed.
TEST BOX OPERATION.
Test Box Messages
When the Test Box is turned on, the following message is displayed.
The “166x Series” part of the message
identifies the system types that the Test Box is designed to operate with. “12/19/01” is the date of the Test Box firmware. “Ver 1.4” is the version of the
Test Box firmware. Plugging the Test Box probe into the Test Box Antenna Connector puts the Test Box into a self-test mode. In this mode, the Test Box loads its own internal battery and then displays the loaded battery voltage along with the low battery threshold point.