Rossum Control Forge Quick Start Manual

Page 1
CONTROL FORGE
Programmable Universal CV Generator
Thanks for purchasing (or otherwise acquiring) Control Forge. This guide will get you up and running with a minimum of fuss. However, given Control Forge’s many features, you should really (really!) check out the full owners manual at
www.rossum-electro.com/support/documentation
Installation
Plug the 16-pin connector into the header on the rear of the module such that the red stripe on the cable (the -12V side) is on the same end of the header as the “Red Stripe (-12V)” text on the PCB.
Control Forge requires, at most, 125mA of +12V and 25mA of -12V.
We have included both M3 and M2.5 (for vector rails) mounting screws. Use what fits your system.
If rack rash is of concern to you, use the included nylon washers when mounting Control Forge in your case.
Be Sure You Have the Latest Firmware
If we’ve released an updated version of firmware after your module was shipped to your dealer, you should update to that latest version before proceeding. To check:
> Ensure that your Control Forge is in Play
Mode and press and hold the Global
button until the Utilities screen appears. Scroll to the bottom of the menu to see the current installed firmware version.
> On the web, go to the Downloads tab
at www.rossum-electro.com/products/ control_forge/ and note the latest firmware version.
> If it’s the same as the version in your
module, you’re good to go. If not, follow the instructions there to update your module.
Making Connections
The best way to get a quick idea of what your Control Forge can do is try out some of the included presets. You’ll find descriptions of the presets in the manual.
While some of the presets require unique connections, most can be auditioned using the following general setup:
> Patch the + Output to the CV in of a
VCO and/or VCF and/or VCA or other processor. (It’s easiest to clearly hear what’s happening with a preset by listening to its eect on a VCO.)
> Patch the Trigger 1 output to the gate
input of an envelope or other triggered CV source.
> Patch the output from a gate or trigger
source into the Gate/ Trig input.
> Patch a CV source into the Time
Scale CV input (preferably through an
attenuator).
Now go play!
Page 2
Functional Overview
www.rossum-electro.com
1 TIME & LEVEL Sets the duration and
target level of each segment. Levels can be defined absolutely or relative to the ending level of the previous segment, can be quantized to the nearest 1/12 volt, and can have a range of randomness of either linear or gaussian distribution.
2 TRANSITION SHAPE Each segment
can have one of 67 dierent transition shapes, including the ability to pass CVs directly through to the output for individual segments.
Also included are “DC” shapes that allow the module to be used as a sequencer. Sequences can be hundreds of steps long and modified in real time manually or by CVs.
3 CONDITIONAL JUMPS Each
segment may have a conditional jump that results in a jump to another selected segment (or to a completely dierent preset) if a particular condition is met (e.g., a CV being above or below the
selected conditional value, the presence or lack of a gate or logic high at their respective inputs, etc).
4 TRIGGERS Two
independent triggers can be programmed to fire in response to a variety of events and can be used to aect either Control Forge itself or external modules.
5 GATE/TRIG, LOGIC,
& CVS Inputs that
allow external control of triggering, time scaling, and CV level testing for conditional jumps.
6 SEGMENT
BUTTONS Used to select
segments for editing and to manually jump to selected segments in performance.
7 PRESETS 500 presets
can be saved and recalled.
8 PRESET SEQUENCER Allows stepping
through up to 200 user-defined series of presets under trigger, clock or manual control, for contours and sequences of almost unlimited length and complexity.
+ SATELLITE All presets
and sequences can be transferred to any number of Satellite modules, which can then operate as stand­alone modulation sources, completely independent of the Control Forge.
Loading...