Rossmax Suction Tester Instruction Manual

Portable Testing Device
for Suction unit
Manufacturer: Rossmax International Ltd., 12F., No. 189, Kang Chien Rd., Taipei, 114, Taiwan www.rossmax.com
EC Representative: Rossmax Swiss GmbH, Tramstrasse 16, CH-9442 Berneck, Switzerland
OBM_IB_SuctionTester_ver1903
Model: Suction Tester
Instruction Manual
www.rossmax.com
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
25
30
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
30
40
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
0
10
0
5
10
15
20
25
30
20
30
40
50
60
70
76
cm Hg
in Hg
Introduction
Rossmax Suction Tester is a portable and easy-to-use device that allows the users to quickly check the performance of the pump of a suction unit. Power source is not required for Suction Tester during operation and the test result is easy to read and interpret. Suction
Tester consists of an oil vacuum gauge, ow meter, PVC tubing and stainless steel stand.
This device is used to check the working conditions of the pump, and you are able to check:
1. Maximum (free) air ow
2. Maximum vacuum
Parts name/location
Flow meter
Regulator
Installation
Insert PVC tubing
into connector
Screw the nut
15
10
20
40
30
50
20
60
25
10
70
0
76
cm Hg
in Hg
0
30
5
PVC tubing
Vacuum
gauge
(2) Suction tester with NK1000 (Nasal Aspirator)
20
50
60
25
70
76
30
(1) Suction tester with Suction unit
(1)
15
10
40
30
20
5
10
0 cm Hg
in Hg
0
(2)
securely
Connector
15
10
20
40
30
50
20
60
25
5
10
70
76
0
cm Hg
in Hg
30
0
Operation procedures
1. Check maximum (free) air ow
Step 1: Turn the regulator of ow meter anticlockwise around 2~3 circles. Step 2: Insert the other end of PVC tubing into the air inlet of the suction unit. Step 3: Power on the suction unit. Step 4: Keep the suction unit running for 30 seconds to warm up. Step 5: Adjust air ow and set the level of vacuum at 0 cmHg by turning the
regulator of ow meter.
Step 6: Check the air ow rate.
Step 7: Turn off the suction unit.
Step 8: Disconnect the PVC tubing from suction unit.
2. Check maximum vacuum
Step 1: Turn the regulator of ow meter anticlockwise around 2~3 circles. Step 2: Insert the other end of PVC tubing into the air inlet of the suction unit. Step 3: Power on the suction unit. Step 4: Keep the suction unit running for 30 seconds to warm up. Step 5: Set the air ow rate at 0 L/min by turning the regulator of ow meter
clockwise completely.
Step 6: Check the values on the vacuum gauge.
Step 7: Turn off the suction unit.
Step 8: Disconnect the PVC tubing from suction unit.
Specications
Power source No need
Operating temperature 0 ~ 54ºC
Storage temperature -10 ~ 60ºC
Air ow
Vacuum
scale 0~50 L/min
accuracy ±4% of full scale
scale 0~-76 cmHg
accuracy ±2.5% of full scale
Weight 730g
Dimension 120(L) x 105(W) x 145(H) mm
Cautions and maintenance
1. This device should be used with suction unit only.
2. Place the device and suction unit on a at, horizontal surface while in use.
3. Turn the regulator slowly to avoid possible damage.
4. Do not completely unscrew regulator stem.
5. Do not attempt to disassemble the device.
6. Avoid excessive vibration, physical impact and dropping.
7. Do not store the device in direct sunlight, high temperature or humidity.
8. Keep the device away from static electricity.
Loading...