Rosslare AS-34, SA-34G, SA-34H, SA-34W Installation Instructions And Operators Manual

AS-34/SA-34G/H/W
Installation Instructions Optical Smoke Detector
0706-0960322+00
1. Introduction
The AS-34 optical smoke detector is a standalone supervised smoke detection and warning system for use in family homes or other residential locations. The unit is easy to install and powered by a single 9V battery, which can sustain the unit’s operation for up to 1 year. The smoke detector regi st ers smoke particles by their photoelectric effect, making it especially sensitive to smoky and smoldering fires that burn slowly for many hours before bursting into flames. For example, this type of fire might be caused by a cigarette burning against a sofa. The detector can connect to Rosslare's security system panel, or to any standard wireless security system. To connect the AS-34 smoke detector to a wired or wireless system, mount it on Rosslare's SA-13G (wireless;
433.92MHz), SA-13H (wireless, 868.35MHz), or SA-13 W (wired) base.
NOTE:
When the unit's battery is running low, the unit beeps, flashes its LED indicator, and sends an alert message to its host control pane l.
A fully mounted unit (AS-34 + SA-13G/H/W) is referred to as SA-
34G/H (wireless) or SA-34W (wired).
NOTE: The AS-34 Smoke Detector is not designed to serve as a substitute
for a primary fire detection system.
Figure 1. AS-34 Optical Smoke Detector
2. Technical Specifications
2.1 Electrical Characteristics
AS-34 Detector Current: Standby Alarm: 15–25 mA
: 10 µA
SA-13G/H Base Current: Standby: 16 µA
Transmitting distance: up to 200m
in open space
Transmitting: 16 mA
SA-13W Base Current: NC output:
Standby: 21 mA
Operating: 7 mA
NO output: Standby: 10 mA
Operating: 23 mA
Battery (for SA-34G/H): IEC 6LF22 or MN1604 (9V Alkaline ) Battery Life: 1 year Low Battery Detection:
2.2 Environmental Characteristics
Last 7 days of battery life
Use Environment Indoor Operating Temper a tur e : 0°–40°C (32°–104°F) Operating Humidi ty :
2.3 Physical Characteristics
10% to 90% Non-Condensing
Sensitivity: 0.5% ± 4% FT nominal Indicators: LED and siren Siren Volume: 85 dB at 3m Dimensions:
4.66 x 4.21 x 1.57 inch SA-34G/H: 126.5 x 124 x 63.7 mm (4.98 x 4.88 x 2.5 inch) SA-34W: 121 x 112.6 x 58.5 mm
AS-34: 118.4 x 107 x 40 m m
(4.76 x 4.43 x 2.3 inch)
Weight:
SA-34G/H: 307g (10.38 oz)
AS-34: 130g (4.59oz)
SA-34W: 192.4g (6.5 oz)
3. Installation
The AS-34 is a photoelectric detector, it can be operated as a standalone unit or as an alarm system together with the SA-13 wireless or wired base. Mount the smoke detector on the ceiling in a central area with plenty of air circulation, as described below.
3.1 Location
For full protection, every room should have a smoke detector fitted. In a home with more than one storey, at least one smoke detector should be fitted on each landing and at the bottom of the staircase. Ensure the alert siren is audible from every room.
Do not fit the smoke detector:
In areas where the temperature falls below 0°C or reaches above
40°
In humid areas, such as bathrooms, kitchens, or shower rooms
C
In a garage or other areas where exhaust gases may cause false
alarms
Close to radiators or ventilation vents, which disrupt the airflow In a workshop or other dusty environment
3.2 Wiring the SA-34W
For wiring instillations follow the instructions below.
To set and wire the SA-34W:
1. set the alarm output setting to either Normally Open or Normally Closed using the select switch on the SA-13W.
2. Connect the power between the Security Alarm system and the SA­13W’s Vin and ground terminal blocks.
3. Connect the Tamper outpu ts to the S e c u ri ty Alarm system’s inputs
4. Connect the Alarm terminal blocks to the Security Alarm system, refer to the installation manual of the alarm system you are connecting the detector to.
Figure 2 Wiring Diagram
3.3 Mounting the Detector
Before mounting the Detector, ensure that your chosen mounting area is not in front of any electrical wiring or pipe work.
1. Mark two mounting points in the ceiling according to the base (SA­13G/H/W) size and holes.
2. Drill into the marked points and insert wall plugs.
3. Using screws, mount the base onto the ceiling.
4. Mount the AS-34 unit on the base (see Figure 3).
NOTE:
Be careful not to over-tighten the screws.
Figure 3. Mounting AS-34 on the Base Unit
AS-34 Standalone SA-34G/H Wireless Base SA-34W Wired Base
0706-0960322+00
4. Operating the Smoke Detector
4.1 General Use
During normal operation, the smoke detector's LED indicator should flash once per 40 seconds.
When the unit detects smoke, it triggers its built-in siren. If the detector is connected to a wireless or a wired security network, it sends an alert message to the host security panel.
NOTE:
Do not paint or cover the detector.
4.2 Testing the Detector
To test the smoke detector, push and hold the self-test button. A loud pulsating siren sounds and the LED indicator flashes quickly,
while a signal is emitted to the host control panel (if part of a system). We recommend testing the smoke detector once a week.
Figure 4. Test Button Location
4.3 Low battery
When the detector' s battery is low, the detector beeps once per 40 seconds. The detector continues operating with a low battery for at least 7 days.
4.4 Maintenance
Dust and dirt reduces the smoke detector's sensitivity. Clean the smoke detector regularly, by passing a v acuum cleaner with a brush attachment gently over the front grilled sections and sides of the smoke detector.
When the detector's battery is low, the detector beeps once every 40 seconds.
The smoke detector continues operating with a lo w battery for at least 7 days.
5. Limited Warranty
ROSSLARE ENTERPRISES LIMITED S (Rosslare) ONE YEAR LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's ONE YEAR LIMITED WARRANTY is subject to the following conditions:
Warranty of Rosslare's products extends to the original purchaser (Customer) of the Rosslare product and is not transferable.
Warranty
ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARI ES (ROSSLARE) warrants that the AS-34 Optical Smoke Detector, to be free from defects in materials and assembly in the course of normal use and service. The warranty period commences with the date of shipment to the original purchaser and extends for a period of 1 year (12 Months).
Products Covered By This Warranty and Duration
In the event of a breach of warranty, ROSSLARE will credit Customer with the price of the Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty. Unless otherwise requested by ROSSLARE ENTERPRISES LTD. AND / OR SUBSIDIARIES representative, return of the failed product(s) is not immediately required.
Warranty Remedy Coverage
If ROSSLARE has not contacted the Customer within a sixty (60) day holding period following the delivery of the warranty claim, Customer will not be required to return the failed product(s). All returned Product(s), as may be requested at ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARY’S sole discretion, shall become the property of ROSSLARE ENTERPRISES LTD. AND / OR SUBSIDIARIES. To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to obtain an RMA number after which, the product must be returned to the Manufacturer freight prepaid and insured In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day holding period and no defect is found, a minimum US$ 50.00 or equivalent charge will be applied to each Product for labor required in the evaluation. Rosslare will repair or replace, at its discretion, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by Rosslare or a Rosslare authorized service center.
ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated. This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product that is used with any ancillary equipment, which is not furnished by ROSSLARE.
Exclusions and Limitations
This warranty does not cover expenses incurred in the transportation, freight cost to the repair center, removal or reinstallation of the product, whether or not proven defective. Specifically excluded from this warranty are any failures resulting from Customer's improper testing, operation, installation, or damage resulting from use of the Product in other than its normal and customary manner, or any maintenance, modification, alteration, or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defects or damage due to lightning or other electrical discharge. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument, or any modification or abuse of, or tampering with, the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim. ROSSLARE does not warrant the installation, maintenance, or service of the Product. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall Rosslare be liable for incidental or consequential damages.
THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD. AND ITS SUBSIDIARIES WARRANTY
.
Limited Warranty Terms
97BTHE TERMS OF THIS WA RRANTY MAY NOT BE VARIED BY ANY PERSON, WHETH ER OR NOT
PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE
.
98BTHIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES. ALL OTHER
WARRANTIES EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
, ARE SPECIFICALLY
EXCLUDED
.
99BIN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE
OF THE PRODUCT, OR FOR ANY OTHER INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF USE
, LOSS OF TIME, COMMERCIAL LOSS,
INCONVENIENCE
, AND LOSS OF PROFITS, ARISING OUT OF THE INSTALLATION, USE, OR INABILITY
TO USE SUCH PRODUCT
, TO THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE
DISCLAIMED BY LAW
.
100BTHIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE
PROVISIONS OF THIS LIMITED WARRANTY
.
6. 41BContact information
52BAsia Pacific, Middle East, Africa 56BHeadquarters:
25B905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road, Kowloon Bay HK 26BTel:+852 2795-5630 Fax: +852 2795-1508 27BE-mail: 1TUsupport.apac@rosslaresecurity.comU1T
53BUnited States and Canada 28B1600 Hart Court, Suite 103 Southlake, TX, USA 76092 29BToll Free:+1-866-632-1101 Local:+1-817-305-0006 Fax: +1-817-305-0069 30BE-mail: 1TUsupport.na@rosslaresecurity.comU1T
54BEurope 57BGlobal Technical Support & Training Center:
31BHaMelecha 22 Rosh HaAyin, Israel 48091 32BTel: +972 3 938-6838 Fax: +972 3 938-6830 33BE-mail: 1TUsupport.eu@rosslaresecurity.comU1T
55BSouth America 34BPringles 868, 1640 Martinez Buenos Aires Argentina 35BTel: +54 11 4798-0095 Fax: +54 11 4798-2228
15BWeb Site:1TU www.rosslaresecurity.comU1T
TEST
BUTTON
Loading...