Rosslare SA-26, SA-27 SA-28 Installation Instructions Manual

SA-26/27/28
1/2/4-Button Remote
Control Transmitter
Q: What is a Transmitter ? A: A t ransmitter is an electronic device that uses RF
energy and coded digital messages to control and communicate commands to other electronic products.
Q: What is SA-26/27/28 WIRELESS REMOTE and how
can it benefit me ?
A: S A-26/27/28 allows the user ARM and DISARM a
Security Panel Access Control Reader, PANIC or even turn on and off the lights and appliances usi ng a Universal Receiver by the use of RF signal.
Q: What is SUPERVISOR or SUPERVISED sensor ? A: A S upervised sensor continuously reports to the
receiver or security panel to confirm status of th e sensor and its presence. If the receiver fails to hear from a sensor within a pre-programmed time, it will presume a sensor is missing or malfunctioning and notify the user. This provides added security.
INTRODUCTION (FAQ's) - continued;
OPERATION - GENERAL NOTES
Use only the specified AAA-sized 1.5 Volt Alkaline Battery.
1) Push down the Battery Compartment Latch and lift to remove (FIG 1).
2) For a new unit, simply remove the plas tic strip contact breaker. For replacement, remove the battery by using a small screwdriver (FIG 2). CAUTION: Notice the polarity of the battery (+) and (-) must coincide with the markings (+) and (-) on the plastic. Check that the battery is held securely.
3) Dispose of the old battery properly. Do not incinerate, heat, disassemble, recharge.
4) To test, press the buttons on the remo te control and see if there is a transmission. The LED will light to indicate an RF transmission (FIG 3).
5) Close the front cover, by engaging the rid ges of the top case and bottom case near the keychain eye hole, align and gently press together both covers and replace the locking screw.
FIG 1: Back of the SA-26/27/28
Housing
The SA-26/27/28 is a miniature radio transmitter, designed to send coded RF transmissions to wireless receivers and control panels. The transmissions are activated by depressing one of the pushbuttons (1, 2 o r 4 - depending on model) on the unit.
After Removing the battery compartment cover, remove the old batteries and install the batteries in the correct alignment shown.
FIG 2: Replacing the 2 AAA-sized Batteries
After activating or replacing the battery in th e SA-26/27/ 28, test the transmitter by pressing each one of the three buttons to see if there is a transmission.
When pushing one of the transmit buttons, the LED will flash to indicate a transmission.
FIG 3: Testing the Buttons
Fig 4: Back of the SA-26/27/28 Cover
Step 3: RECEIVER COMPATIBILITY
The installation procedure for using the SA-26/27/28 remote control varies from product to produc t.
Full instructions are printed within the installation manual each of the receiver panels or controls.
For this instruction manual, the instructions cover onl y the SP-06 V Wireless Security Control Panel in 433.92 or
868.35 MHz;
The following pages show the simplified enrollment procedures for enrolling SA-26/27/28 transmitters to Rosslare’s SP-06 V panel. For full details about the Wireless Control Panel, please refer to the SP-06 V Installation and Programming Manual.
AND IMPORTANT INFORMATION
INSTALLATION INSTRUCTIONS
P/N:
0706-0960079+01
GENERAL DESCRIPTION
INTRODUCTION (FAQ's)
Q: What is LOW BATTERY detection ? A: For all supervised sensors, LOW BATTERY
detection is when a sensor continuously measures its battery state and transmits a low battery signal to the security panel when the battery's voltage drops below a certain level. This alerts the user in advance to replace a weak battery.
Q: What is a CASE TAMPER detector? A: A Case Tamper detector monitors any unauthorized
opening of the unit housing. A signal will be transmitted to the security panel to notify the user of such tampering.
Q: What is a BACK TAMPER detector ? A: Once the sensor is mounted and activated, the Back
Tamper detector ensures that the sensor is no t removed or vandalized by detecting any removal of the unit from a wall or corner. The Back tamper detector will alert the security panel in such cases.
The SA-26/27/28 remote control is activated by pressing the buttons on the unit and transmits this information to the receiver panel.
Since the SA-26/27/28 is a portable wireless device and system reception is dependent upon the condition s of use as follows:
STEP-1 BATTERY INSTALLATION (Fig1,2)
STEP-2 TESTING THE TRANSMISSION
The SA-26/27/28 in 433,92 or 868.35 MHz frequency is compatible with a variety of Rosslare's security panels, universal receiver controls, and system componen ts.
SP-06 V Wireless Security Control Panel, SA-22 Dual Channel Receiver, SA-38 Channel Receiver, AY-L23 Wireless Receiving Wiegand 26, Reader
SA-29 Wireless Repeater with UPS - System Level
and others...
For an updated list please contact your distributor, dealer or agent.
1
2 3
4
5 6
7
8 9
10
11 12
SA-26/27/28 Instruction Manual - Version 1.0 (Page 1/2)
- AVOID: Placing the SA-26/27/28 near strong magnetic or electrical fields other than the magn et with which it is intended to be used. Otherwise, performance could be affected and false alarms could occur.
- AVOID: Using near or behind large metal surfaces and multiple concrete/steel walls. This may interfere or block the wireless signals. Make sure to test the range from the desired location by using the RF Test Procedure to ensure reception.
- IMPORTANT NOTE: When the battery power has been depleted, as indicated by a very dim LED, replace the battery immediately.
The SA-26/27/28 can control up to 4 functions when used with Rosslare’s Wireless Security Control Panels or Universal RF Receivers. The SA-26/27/28 is a battery operated wireless device using a standard 12 Volt Alkaline battery. An LED (Light Emitting Diode) lights during the transmission of the RF signal. Which lights when the battery voltage exceeds 8 VDC. If the LED does not light during the transmission, the battery must be replaced immediately.
SA-26/27/28 is a high quality wireless sensor packed with intelligent wireless and system features such as compatibility with RF Repeaters. Inside the SA-26/27/28 is a state of the art microprocessor, with ASK RF transmitter technology, and is encoded with 16 million factory programmed non-recurring ID codes ensu ring that multiple units can be used on a single system.
Turn the unit over and pull the battery compartment cover latch down, and lift, to open.
+
+
-
-
LED Function: LED will flash when the SA-26/27/28 is transmitting
Function: ARM Button for the Security Panels or Single Channel Transmitter
Function:
Disarm Button
for the Security
Panels or Single
Channel
Transmitter
Function: Emergency Panic Button for the Security Panels or Single Channel Transmitter
Place the battery compartment cover back into the latch, swing shut, until the top latch clicks shut.
The SA-26/27/28 in 433.92 or 868.35 MHz, is compatible with receivers from Rosslare, including the SP-06 V wireless security control panel. This is a short enro lling tutorial for the SP-06 V Panel.
The SA-26/27/28 can be installed by enrollment to ZONE 8 of the SP-06V Panel. Zone 8 can accommodate up to 8 (eight) handheld Remote controls or RF keyboard transmitters.
SA-26/27/28 Remote Control enrolls to any one of the eight addresses in Zone 8 of the SP-06V Wireless Security control panel.
When installed onto the SP-06 V panel, the SA-26/27/28 will have one ARM/ PARTIAL ARM, one DISARM and one PANIC button, active for 24 hours from any mode of the SP-06V.
Enrolling the SA-26/27/28 to Zone 8 of SP-06 V:
1) Using the installer pass code (8888) by pressing the MENU button and entering the code on the keyboard, enter the Installer Menu.
You will then enter the installer programming menu for the SP-06 V control panel
SILENT
PANIC
8
ON Z E
Zone Numbe r
Remote ControlType Displa
y
PANIC = Audiable Pani
c
SILENT = Silent Duress Alarm
Zone Box Status Displa
y
ZONE
= Zone is armed
ZONE
(flashing)= Zone was triggered
LCD Example of ZONE BOX Display
432
5 6 7 8
1
OFFMENU
ESC
SET
INSTALL CODE
MASTER
CODE
ZONE
PANIC
MENU
ESC
ENTER
SUPERVISION
MASTER CODE USER CODE
SET OUTPUT
SIREN TIME
EXIT DELAY CLOCK
SYSTEM
TEST
PARTIAL OFF
MODE
SET SIREN
SILENT PANIC
A
CTIVATE
CHIME
CODE
ENTRY DELAY
CLEAR R/F
ADD R/F
SET ZONE
TELEPHONE
ZONE
MENU
ESC
NUMBER
ENTRY DELAY
CLEAR R/F
ADD R/F
SET ZONE
ZONE
MENU
ESC
ENTER
ADD R/F
SET ZONE
ZONE
PANIC
8
ZONE
CLEAR R/F
Battery: Two 1.5-Volt AAA Alkaline Battery
Use only the specified 1.5-Volt Alkaline Battery
Operating Temp: -10
o
C to +50oC
[14
o
F to + 122oF]
Operating Humidity: Up to 95% Non-Condensing (max.)
Alarm Transmit: 500 ms (milliseconds)
RF Frequency: Available in 433.92 or 868.35 MHz
Usage: Carried in pocket or worn on a belt; for indoor (dry) use only.
Tamper: The SA-26/27/28 has no tamper transmission.
Supervisor: The SA-26/27/28 is not a supervised transmitter.
Current: Standby -0 A
Transmit - 16 mA
Size: 104mm (h) x 40mm (w) x 15mm (d)
(4.09 " x 1.57" x 0.59")
Weight: 28 grams including battery.
Color: Brown
The Manufacturer does not represent that its Product may not be compromised and/or circumvented, or that the Product will prevent any death, personal and/or bodily injury and/or damage to property resulting from burglary, robbery, fire or otherwise, or that the Product will in all case provide adequate warning or protection. User understands that a properly installed and maintained alarm may only reduce the risks of events such as burglary, robbery and fire without warning, but is no assurance or a guarantee that such will not occur or that there will be no death, personal damage and/or damage to property as a result.
The Manufacturer shall have no liability for any death, personal and/or bodily injury and/or damage to property or other lo ss whether direct, indirect, incidental, consequential or otherwise, based on a claim that the Product failed t o function.
However, if the Manufacturer is held liable, weather directly or indirectly, for any loss of damage arising under this limited warranty or otherwise, the Manufacturer’s maximum liability shall not in any case exceed the purchase price of the Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Manufacturer.
Warning: The user should follow the installation and operation instructions and among other things test the Product and the whole system at least once a week. For various reasons, including, but not limited to, changes in environmental conditions, electric or electronic disruptions and tampering, the Product may not perform as expected. The user is advised to take all necessary precautions for his/her safety and the protection of his/her property.
&
MENUMENU
88
2) In the INSTALLER MENU, press the down arrow to select the ZONE menu and press Enter
3) In the ZONE menu, when prompted for the zone number, press the number 8 to select Zone 8.
&
88 88 88
4) To program operation of the Panic Button U se the down arrow to select SET ZONE option and Press Enter.
5) Press the SET key until the zone type shows “PANIC”, for an audible emergency alarm, to enable the SA-26/ 27/28 to perform a non audible alarm, scroll to “SILENT PANIC”. Press ENTER to enable your selection of either PANIC to sound or not to soun d an ALARM at the panel, if the alarm is transmitted from the SA-26/27/28 Remote Control.
6) Within the zone 8 menu, use the arrow key to select ADD RF and press enter, use the arrow key to select the desired available slots from 8.1 to 8.8, and press ENTER.
7) When Prompted for RADIO, press any pushbuttons on the SA-26/27/28 to transmit,
MENU
ESC
ENTER
ADD R/F
SET ZONE
ZONE
PANIC
8
ZONE
CLEAR R/F
&
ENTERENTER
&
&
88
SETSET
&
ENTERENTER
&
MENU
ESC
ENTER
SET
ADD R/F
ZONE
8
ONZE
PANIC
&
&
ENTERENTER
8) When the control panel receives the coded signal from the SP-03 V there will be a been and an indication to press enter on the LCD. Press the ENTER button on the panel’s keyboard.
9) Once the SA-26/27/28 is enrolled onto the SP-06 V control panel, the remote control may be used to perform 4 Functions, such as ARMING (Full Away Arming all Zones), PARTIAL ARMING (Part Zones Arming for Stay), DISARMING, and EMERGENCY PANIC.
&
ENTERENTER
! Warning ! Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Rosslare Enterprises Ltd.) could void the user's authority to operate the equipment.
Our wireless systems are very reliable and are teste d to high standards. However, due to their low transmitting power (required by international standards imitations) there may be some limitations to be considered:
A. Receivers may be blocked by radio signals occurring
on or near their operating frequencies, regardless of the ID.
B. A receiver can res pond to one transmitted signal at a
time
C. Wireless equipm ent should be tested regularly (At
least once a week) to determine if there are sources of interference and protect against faults.
MISCELLANEOUS COMMENTS
SA-26/27/28 SPECIFICATIONS
Rosslare Enterprises Ltd. And/or its subsidiaries and its affiliates (“the Manufacturer”) warrants it’s products hereinafter referred to “the Product” or “Products” to be in conformance with it’s own plans and specifications and to be free of defects in materials and workmanship under the normal use and service for a period of twelve months from the date of shipment by the Manufacturer. The Manufacturer’s obligations shall be limited within the warrantee period at its option to repair or replace the product or any part thereof. The manufacturer shall not be responsible for dismantling and/or reinstallation charges. To exercise the warranty the product must be returned to the Manufacturer freight prepaid and insured.
This Warranty does not apply in the following cases: improper installation, misuse, failure to follow installation and operating instructions, alteration, abuse, accident or tampering, and repair done by anyone other than the Manufacturer.
This warranty is exclusive and expressly in lieu of al other warranties, obligations or liabilities, weather written, oral, express or implied, including warranty of merchantability or fitness for a particular purpose, or otherwise. In no case shall the Manufacturer be liable for any consequential damages for breach of this warranty or any other warranties whatsoever, as aforesaid.
This warranty shall not be modified, varied or extended, and the Manufacturer does not authorize any person to act on it’s behalf in the modification, variation or extension of this warranty. This warranty shall apply to the Product only. All products, accessories or attachments of others used in compilation with this product, including batteries, shall be covered solely by their own warranty, if any. The manufacturer shall not be liable for any damage or loss whatsoever, weather directly, indirectly, incidentally, consequentially or otherwise, caused by malfunction of the Product due to products, accessories, or attachments of others, including batteries, used in conjunction with the Products.
STANDARDS COMPLIANCE
European Standards Compliance: Meets the requirements of the Harmonized European Standards for CE Mark.
ETS 301 459 ETS 300 220
Step 4: INSTALLING TO THE SP-06 V WIRELESS SECURITY CONTROL PANEL
12
14 15
16
17 18
19
20 21
WARRANTY
22
23 24
SA-26/27/28 Instruction Manual - Version 1.0 (Page 2/2)
TECHNICAL SUPPORT
Asia Pacific, Rosslare Security Products Headquarters Middle East 905-912 Wing Fat Industrial Bldg, and Africa 12 Wang Tai Road, Kowloon Bay Hong Kong
Tel: +852 2795-5630 Fax: +852 2795-1508 E-mail: support.apac@rosslaresecurity.com
United States 1600 Hart Court, Suite 103 Southlake, TX, USA 76092 and Canada Toll Free: +1-866-632-1101
Local: +1-817-305-0006 Fax: +1-817-305-0069 E-mail: support.na@rosslaresecurity.com
Europe Global Technical Support & Training Center
HaMelecha 22, Rosh HaAyin, Israel 48091 Tel: +972 3 938-6838 Fax: +972 3 938-6830 E-mail: support.eu@rosslaresecurity.com
South America Pringles 868, 1640 Martinez, Buenos Aires, Argentina
Tel: +54 11 4798-0095 Fax: +54 11 4798-2228 E-mail: support.la@rosslaresecurity.com
Web Site: www.rosslaresecurity.com
Press: any other button to generate an RF transmission to enroll the SA-26/ 27/28 to the Control Panel.
Function:
DISARM (Short Press)
Function:
ARM (Short Press) PARTIAL ARM (Long Press)
LED Function:
LED will flash when the SA-26/27/28 is transmitting
Function:
PANIC (2 second Press)
Loading...