Rosslare SA25G User Manual

SA-25 Instruction Manual - Version 1.0 (Page 1/4)
Compatibility: The SAK-25 Wire to RF Transmitter, with Magnetic Contact Sensor, is compatible with a variety of
Rosslare's receivers and panels, in 433.92 or 868.35 MHz.
GENERAL DESCRIPTION
The SAK-25 Universal WIRE to RF Transmitter is a unique RF transmitter, with
advanced features that operates at 433.92 or 868.35 MHz designed for wireless security and control applications.
Totally Universal: Convert Wired Sensors to Wireless, and interface them to the RF Panel or Multi-Channel Receiver. Compatible with wired PIR / Door / Window / Smoke / Rolling Shutter / Vibration sensors / Glass Break Detectors and more.
Main features are: Two programmable wired inputs and One local Magnetic Contact Sensor, which may share a Supervised RF Sensor ID Code, or have three separate Supervised ID Codes (Supervisor will transmit every 20 minutes, or 1 hour, depending on model ordered). The SAK-25 operates on a 3.6V / 900mAh lithium battery with low current draw, one battery lasts for min 2 Years (With 200 Transmissions per day). In case of low Batt, SAK-25 will transmit a Low Battery Signal to the control Unit. For Backup Power, an auxiliary power input can be connected at +12V DC and GND from the host panel of the wired sensor, or an AC/DC Adaptor.
ADVANCED FEATURES
* Programmable Locally or by PC Software Utility (RS232) * Ultra Low Power Microprocessor Design with Real-Time Software * Tamper-Proof Internal Antenna * Supervised (Every 20 minutes), with Low Battery
* Cover and Wall (Selectable) - Double Tamper Detection * Pulse counting Wired Input for Rolling Shutter, Shock
Detection facility programmable to 3,6, or 9 pulses
* 3 Channels (2 Wired, 1 Local Mag Contact) programmable
as three independent zone ID's or as a single zone ID's.
* Programmable Enable Disable of Local Magnetic Contact Sensor.
PROGRAMMING
Programming of the SAK-25 can be performed locally using the LED and the buttons S1 and S2, as well as, from a connected PC. You may connect to the SAK-25 from the PC using the MD-14 RS232 to RS485 converter and Rosslare's SAK-25 Utility Software for the PC. (Available from Rosslare Website),
SOLID RED LED MENU for programming
the operation of Inputs 1 and 2
PC-Link Connector
RS-232 I/O connects
to PC via supplied
data cable.
Model : SAK-25
Input 2
Terminal Blocks
Input 1
Terminal Blocks
Local Programming the operation of the SAK-25 is available locally using the push buttons S1 and S2 and the Tri Color LED.
1) Press both buttons at the same time and release when the LED is solid red to enter the menu
Solid Red LED MENU
2) Press S1 to scroll Input 1 programming modes-Release at desired Mode.
3) Press S2 to scroll Input 2 programming modes-Release at desired Mode.
4) Press both S1 and S2 together to exit the menu.
Input 1
(Wired Input) Programmable Locally and by PC Link Software, as any of the options below.
Mode 1: PIR (Normally Open) Mode 2: PIR (Normally Closed) Mode 3: Door/Window (Normally Open) Mode 4: Door/ Window (Normally Closed) Mode 5: Smoke (Normally Open) Mode 6: Smoke (Normally Closed)
Local Programming Menu - S1
Solid Red LED
Flashing Red LED
Solid Orange LED
Flashing Orange LED
Solid Green LED
Flashing Green LED
Input 2
(Wired Input) Programmable Locally and by PC Link Software, as any of the options below.
Mode 1: PIR (Normally Open) Mode 2: PIR (Normally Closed) Mode 3: Door/Window (Normally Open) Mode 4: Rolling Shutter 3 Pulse Count Mode 5: Rolling Shutter 6 Pulse Count Mode 6: Rolling Shutter 9 Pulse Count
Local Programming Menu - S2
Solid Red LED
Flashing Red LED
Solid Orange LED
Flashing Orange LED
Solid Green LED
Flashing Green LED
Silver Plated
Antenna
Customized
Internal Antenna
Inside Model : SAK-25
Battery Power
3.0V 1300mAh Lithium Cell
Mag Contact Sensor
S2 - Button
S1 - Button
And Cover Tamper Switch
- 1 -
SA-25 Instruction Manual - Version 1.0 (Page 2/4)
Compatibility: The SAK-25 Wire to RF Transmitter, with Magnetic Contact Sensor, is compatible with a variety of Rosslare's receivers and panels, in 433.92 or 868.35 MHz
LOCAL PROGRAMMING (cont.)
SOLID ORANGE MENU for Programming Channels Common ID and Independent ID Codes.
Local Programming the operation of the SAK-25 is available locally using the push buttons S1 and S2 and the Tri Color LED.
1) Press both buttons at the same time and release when the LED is solid orange to enter the menu
2) You will see the current mode of the ID Code settings upon release of both of the buttons.
Solid Orange LED MENU
S2S1
Mode 1: All channels report independent ID Mode 2: All channels report same ID
Flashing Red LED
Solid Red LED
3) Press S2 to toggle the current setting.
Same ID Code for all 3 Inputs
If the mode was independent ID's (Flashing Red), pressing S2 will toggle the mode to same ID Codes for three Channels.
Flashing Red LED
Solid Red LED
Press both S1 and S2 together to exit the menu.
Different ID Codes for all 3 Inputs
If the mode was Same ID's (Solid Red), pressing S2 will toggle the mode to independent ID Codes for three Channels.
Solid Red LED
Flashing Red LED
Press both S1 and S2 together to exit the menu.
FLASHING ORANGE MENU for Programming Channel 3 Local Magnetic Sensor Restore Event Operation
Local Programming the operation of the SAK-25 is available locally using the push buttons S1
Flashing Orange LED MENU
and S2 and the Tri Color LED.
1) Press both buttons at the same time and release when the LED is solid orange to enter the menu.
2) You will see the current mode of the ID Code settings upon release of both of the buttons.
S2
S2
S2S1
Mode 1: Built-in Magnetic Sensor will not automatically send restore, only when the magnet
will be effectively restored.
Important Note: This local menu will only allow programming if Input 1 is programmed as Magnetic Door/ sensor & Normally Open
Mode 2: Built-in magnetic sensor will automatically send the restore signal after two seconds, even if the magnet has not been effectively restored.
Important Note: This local menu will only allow programming if Input 2 is programmed as 3,6 or 9 pulses rolling shutter or vibration pulse counting.
3) Press S2 to toggle the current setting
Toggling Mode 1 to Mode 2
If the mode was Mode 1 (Flashing Red) pressing S2 will toggle the mode to Mode 2.
Toggling Mode 2 to Mode 1
If the mode was Mode 2 (Flashing Red) pressing S2 will toggle the mode to Mode 1.
- 2 -
Flashing Red LED
Solid Red LED
Flashing Red LED
Solid Red LED
Solid Red LED
Flashing Red LED
S2
S2