Rosslare AY L23H, AY L23G, SA 23G, SA 23H User Manual

AY-L23 G/H and SA-23 G/H
Outdoor Long-Range RF Reader and Remote Control May 2013
Installation and Operation Manual

1. Introduction

The AYL-23G/H is an outdoor long-range RF reader that acts as a receiver. It is compatible with Rosslare’s SA-23 wireless remote control transmitter. The AY-L23 G works with the SA-23 G (433.92 MHz) and the AY-L23 H works with the SA-23 H (868.35 MHz).
When the AY-L23 receives the a command signal from the SA-23 wireless transmitter, the AY-L23 outputs the ID to A_DATA0,A_DATA1 or B_DATA0,B_DATA1 to the attached controller and controls the function of the relay (open drain FET) A or B according to the SA-23 remote’s command.
The command signal consists of 3 parts:
ID (in Wiegand format) ID output to A or B Wiegand Output according to the command in
SA-23
Relay Function A or B according to command in the SA-23

2. Technical Specifications

2.1 AY-L23 G/H

Input Voltage
Standby Current
Maximum Operating Current
Relay (FET, Open Drain) Current
Tamper Output
Maximum Cable Distance to Controller
Wiegand Output Format
Frequencies
Read Range
Operating Temp. Range
Operating Humidity
Dimensions (L x W x D)
7 to 24 VDC
26 mA (12 VDC)
65 mA (12 VDC)
200 mA (max voltage 40 V)
Open collector, active Open, max. sink current is 16 mA
500 ft. (152.4 m)
Wiegand xbit (Wiegand xbit<=Wiegand 40­Bit, decided by remote
G: 433.92 MHz H: 868.35MHz
164 ft (50 m)
-31°C to 63°C (-25°F to 145°F)
0 to 95% (non condensing)
5.7 x 1.7 x 0.8 in. (145 x 43 x 20 mm)
Figure 1: AY-L23 G/H and SA-23 G/H
AY-L23 G/H SA-23 G/H

2.2 SA-23 G/H

Input Voltage
Standby Current
Max Operation Current
ID Format Frequencies
Operating Temp. Range
Operating Humidity
Dimensions (L x W x D)
3 V Battery (CR 2450)
< 1 uA
10 mA
Programmed to Wiegand 26-Bit
G: 433.92 MHz (ASK) H: 868.35 MHz (ASK)
-31°C to 63°C (-25°F to 145°F)
0 to 95% (non condensing)
2.28 x 1.61 x 0.53 in. (58 x 41 x 13.4 mm)

3. Mounting Instructions

Determine an appropriate mounting position for the receiver. Do not mount the receiver near any source of wireless interference or on any metal surface.
To mount the receiver:
1. Peel off the back of the self-stick mounting label template included with the unit and place at the desired mounting position.
2. Using the template as a guide, drill two holes (hole size is indicated on mounting template) for mounting the receiver to the surface.
3. Drill a 7/16” (10-mm) hole for the cable.
4. Remove the front case from the receiver.
5. Attach the receiver to the controller. (See wiring instructions)
6. Screw the receiver’s rear case onto its mounting location and return the front case onto the mounted rear case.
The receiver is to be used with control panels whose power supply is UL Listed Class 2 or equivalent.
1
To activate the relay, the remote button’s ID should be registered

4. Wiring Instructions

To connect the receiver to the controller:
1. Prepare the receiver cable by cutting the cable jacket back 1¼ inches and strip the wires ½ inch.
2. Prepare the controller cable by cutting the cable jacket back 1¼ inches and strip the wires ½ inch.
3. Splice the receiver’s pigtail wires to the corresponding controller wires and cover each connection (see Table 1).
The individual wires coming out of the receiver are color coded according to the recommended Wiegand standard.
When using a separate power supply for the receiver, this supply and the controller’s power supply must have a common ground.
The cable shield wire on the receiver should be attached to an Earth ground (best) or signal ground connection at the panel or power supply end of the cable. This configuration is best for shielding the receiver cable from external interference.
5. 4BOperation
The AY-L23 works with any SA-23 remote and can operate two Wiegand data outputs connected to the reader’s inputs at the access control panel.
5.1 8BReader Mode
When pressing 1 on the SA-23, the AY-L23 sends Wiegand data-A. The LED changes to green for a short time with a beep.
When pressing 2 on the SA-23, the AY-L23 sends Wiegand data-B. The LED changes to orange for a short time with a beep.
The AY-L23 LED is red in Operation mode.
5.2 9BController and Reader Mode
The AY-L23 can register up to 48 IDs for an SA-23 remote control and can operate two OC outputs A/B.
When pressing 1 on the SA-23, the AY-L23 sends Wiegand data-A and activates out-A for 5 seconds. The LED changes to green for a short time with a beep.
When pressing 2 on the SA-23, the AY-L23 sends Wiegand data-B and activates out-B for 5 seconds. The LED changes to orange for a short time with a beep.
The AY-L23 LED is red in Operation mode.
first.
Table 1: Wiring
Color Functionality
Red VIN (7–24 VDC)
Black GND
Dark Green A_Data0
White A_Data1
Orange A_LEDCTL (green LED)
Blue A-OUTPUT (FET, Open Drain)
Light Green B-DATA0
Gray B-DATA1
Brown B_LEDCTL (orange LED)
Yellow B-OUTPUT (FET, Open Drain)
Purple
TAMPER
5.3 10BRegistering an ID
To register an ID:
1. Connect the orange and brown wires to GND.
2. Power on at Vin and GND. After buzzer sounds 3 times, the LED turns green. The AY-L23 is now in Register mode for 15 seconds.
3. Press 1 on the SA-23 remote.
If the registration is successful, you hear 2 short beeps. If the ID was previously registered, you hear 2 long beeps. If the limit of IDs (48) is reached, you hear have 3 long beeps.
4. Press 2 on the SA-23 remote.
If the registration is successful, you hear 2 short beeps. If the ID was previously registered, you hear 2 long beeps. If the limit of IDs (48) is reached, you hear have 3 long beeps.
After the time register (10 to 15 seconds), you hear a long beep.
5.4 11BDeleting all IDs
To delete all IDs:
1. Connect the orange wire to GND.
2. Power on at Vin and GND. After buzzer sounds 3 times, the LED turns orange for 2 seconds
and then turns green. The AY-L23 is now in Delete mode for 5 seconds.
3. When the LED turns green, disconnect the orange wire from GND. The LED changes from green to orange.
4. Re-connect the orange wire to GND within 5 seconds.
If all the IDs in reader are deleted successfully, the alarm
sounds 2 times and then you hear 3 short beeps.
If the deletions fails (times out), the reader outputs a long
beep.
6. 5BUsing the SA-23
The AY-L23 G/H is used along with the SA-23 2-button remote control. The SA-23 remote is programmed to:
Button 1 – Wiegand output to A DATA0/1 with A FET(relay)ON 5S Button 2 – Wiegand output to B DATA0/1 with B FET(relay)ON 5S
6.1 12BInitial Setup
To set up the remote for use:
1. Install the battery. The red LED turns on for 1 second, turns off 1 second and then
turns on for 1 second.
2. Check the distance range of the remote:
If the distance is set to long range (70 m), LED flashes on and
off 0.5 seconds 3 times.
If the distance is set to short range (15 m), LED flashes on and
off 0.1 seconds 6 times.
By default, the remote distance is set to 70 m.
2
Loading...
+ 2 hidden pages