Rosslare SA-23-B4, AY-L23, SA-23-B2 Installation And Operation Manual

AY-L23 and SA-23-B2/B4
Outdoor Long-Range RF Reader and Remote Controls
Installation and Operation Manual
1
1. Introduction
The AY-L23 is an outdoor long-range RF reader that acts as a receiver. It is compatible with Rosslare’s SA-23 wireless remote control transmitters:
SA-23-B2 – 2-Button Remote Control SA-23-B4 – 4-Button Remote Control
The AY-L23 reader and the remote controls are available in both G (433.92 MHz) and H (868.35 MHz) frequencies.
The AY-
L23 is not compatible with old remote controls such as:
SA-26, SA-27, and SA- 28.
When the AY-L23 receives the a command signal from a SA-23-B2/B4 wireless transmitter, the AY-L23 outputs the ID to A_DATA0,A_DATA1 or B_DATA0,B_DATA1 to the attached controller and controls the function of the relay (open drain FET) A or B according to the SA-23-B2 remote’s command.
The command signal consists of 3 parts:
ID (in Wiegand format) ID output to A or B Wiegand Output according to the command in
SA-23-B2
Relay Function A or B according to command in the SA-23-B2
Figure 1: AY-L23 and SA-23-B2/B4
AY-L23 SA-23-B2 SA-23-B4
2. Technical Specifications
2.1 AY-L23
Input Voltage
7 to 24 VDC
Standby Current
26 mA (12 VDC)
Maximum Operating Current
65 mA (12 VDC)
Relay (FET, Open Drain) Current
200 mA (max voltage 40 V)
Tamper Output
Open collector, active Open, max. sink current is 16 mA
Maximum Cable Distance to Controller
152 m (500 ft.)
Wiegand Output Format
Wiegand 26-Bit, 32-Bit, 34-Bit, 40-Bit (decided by remote)
Frequencies
G: 433.92 MHz H: 868.35 MHz
Operating Temperature Range
-31°C to 63°C (-25°F to 145°F)
Operating Humidity Range
0 to 95% (non-condensing) Suitable for outdoor use (IP65)
Dimensions (L x W x D)
145 x 43 x 20 mm (5.7 x 1.7 x 0.8 in.)
2.2 SA-23-B2/B4
Input Voltage
3 V Battery (CR 2450)
Standby Current
< 1 uA
Max Operation Current
10 mA
ID Format
Programmed to Wiegand 26-Bit
Frequencies
G: 433.92 MHz (ASK) H: 868.35 MHz (ASK)
Operating Temp. Range
-31°C to 63°C (-25°F to 145°F)
Operating Humidity
0 to 95% (non-condensing)
Dimensions (L x W x D)
58 x 41 x 13.4 mm (2.3 x 1.6 x 0.5 in.)
Weight
AY-L23: 100.8 g (3.56 oz) SA-23: 21 g (0.74 oz) (without battery)
3. Mounting Instructions
Determine an appropriate mounting position for the receiver. Do not mount the receiver near any source of wireless interference or on any metal surface.
To mount the receiver:
1. Peel off the back of the self-stick mounting label template included with the unit and place at the desired mounting position.
2. Using the template as a guide, drill two holes (hole size is indicated on mounting template) for mounting the receiver to the surface.
3. Drill a 7/16” (10-mm) hole for the cable.
4. Remove the front case from the receiver.
5. Attach the receiver to the controller. (See wiring instructions)
6. Screw the receiver’s rear case onto its mounting location and return the front case onto the mounted rear case.
The receiver is to be used with control panels whose power supply is UL Listed Class 2 or equivalent.
2
4. Wiring Instructions
To connect the receiver to the controller:
1. Prepare the receiver cable by cutting the cable jacket back 1¼ inches and strip the wires ½ inch.
2. Prepare the controller cable by cutting the cable jacket back 1¼ inches and strip the wires ½ inch.
3. Splice the receiver’s pigtail wires to the corresponding controller wires and cover each connection (see Table 1).
The individual wires coming out of the receiver are color coded according to the rec ommended Wiegan d standard.
When using a separate power supply for the receiver, this supply and the controller’s power supply must have a common ground.
The cable shield wire on the receiver should be attached to an Earth ground (best) or signal ground connection at the panel or power supply end of the cable. This configuration is best for shielding the receiver cable from external interference.
Table 1: Wiring
Color Functionality
Red VIN (7–24 VDC)
Black GND
Dark Green A_Data0
White A_Data1
Orange A_LEDCTL (green LED)
Blue A-OUTPUT (FET, Open Drain)
Light Green B-DATA0
Gray B-DATA1
Brown B_LEDCTL (orange LED)
Yellow B-OUTPUT (FET, Open Drain)
Purple
TAMPER
5. 4BOperation
The AY-L23 works with any SA-23 remote and can operate two Wiegand data outputs connected to the reader’s inputs at the access control panel.
The AY-L23 LED is red in Operation mode.
5.1 8BReader Mode
When pressing 1 on the SA-23-B2/B4, the AY-L23 sends Wiegand data-A. The LED changes to green for a short time with a beep.
When pressing 2 on the SA-23-B2, the AY-L23 sends Wiegand data-B. The LED changes to orange for a short time with a beep.
When pressing 2 on the SA-23-B4, the AY-L23 sends ID+1 on Data A line to the controller. The LED changes to green for a short time with a beep.
5.2 9BController and Reader Mode
The AY-L23 can operate two OC outputs A/B with the SA-23-B2. To activate the output from SA-23-B2, the remote button’s ID should
be registered first (Section 5.3).
In Controller and Reader mode, SA-23-B4 is not in use as it does not activate any output of the AY-L23.
When pressing 1 on the SA-23-B2, the AY-L23 sends Wiegand data-A and activates out-A for 5 seconds.
When pressing 2 on the SA-23-B2, the AY-L23 sends Wiegand data-B and activates out-B for 5 seconds.
5.3 10BRegistering an ID
The AY-L23 can register up to 48 IDs with an SA-23-B2.
To register an ID:
1. Connect the orange and brown wires to GND.
2. Power on at Vin and GND. After buzzer sounds 3 times, the LED turns green.
The AY-L23 is now in Register mode for 15 seconds.
3. Press 1 on the SA-23-B2 remote.
If the registration is successful, you hear 2 short beeps. If the ID was previously registered, you hear 2 long beeps.
If the limit of IDs (48) is reached, you hear have 3 long beeps.
4. Press 2 on the SA-23-B2 remote.
If the registration is successful, you hear 2 short beeps.
If the ID was previously registered, you hear 2 long beeps. If the limit of IDs (48) is reached, you hear have 3 long beeps.
Once the AY-L23 exits Register mode (after 15 seconds), you hear a long beep.
Each of the 4 buttons of the B4 remote control is pre­programmed with an ID that cannot be changed.
5.4 11BDeleting all IDs
To delete all IDs:
1. Connect the orange wire to GND.
2. Power on at Vin and GND. After buzzer sounds 3 times, the LED turns orange for 2 seconds
and then turns green.
The AY-L23 is now in Delete mode for 5 seconds.
3. When the LED turns green, disconnect the orange wire from GND.
The LED changes from green to orange.
4. Re-connect the orange wire to GND within 5 seconds.
If all the IDs in reader are deleted successfully, the alarm
sounds 2 times and then you hear 3 short beeps.
If the deletions fails (times out), the reader outputs a long
beep.
3
6. Using the SA-23
The AY-L23 is used along with either the SA-23 2-button or 4-button remote control.
The SA-23-B2 remote is programmed to:
Button 1 – Wiegand output to A DATA0/1 with A FET(relay)ON 5S Button 2 – Wiegand output to B DATA0/1 with B FET(relay)ON 5S
The SA-23-B4 remote is programmed to:
Button 1 – Wiegand output to A DATA0/1 [ID number] Button 2 – Wiegand output to A DATA0/1 [ID number+1]
Button 3 – Wiegand output to A DATA0/1 [ID number+2] Button 4 – Wiegand output to A DATA0/1 [ID number+3]
6.1 Initial Setup
To set up the remote for use:
1. Install the battery. The red LED turns on for 1 second, turns off 1 second and then
turns on for 1 second.
2. Check the distance range of the remote:
If the distance is set to long range (70 m), LED flashes on and
off 0.5 seconds 3 times.
If the distance is set to short range (15 m), LED flashes on and
off 0.1 seconds 6 times.
By default, the remote distance is set to 70 m.
6.2 Changing the Remote Distance Range
You can set the remote range to either 15 or 70 m.
To set the remote distance:
1. Remove the battery from the remote.
2. Press any button to reset the remote.
Any time you remove the battery from the SA-23, you must reset the remote control by pressin g any key to discharge the internal capacitors.
3. Install the battery.
4. Press 1 and 2 together before the LED flashes for a second time.
The remote toggles to the other remote distance range.
If the distance is set to long range (70 m), LED flashes on and
off 0.5 seconds 3 times.
If the distance is set to short range (15 m), LED flashes on and
off 0.1 seconds 6 times.
6.3 Changing the ID of Button 2 (for SA23­B2 only)
You can set Button 2 to transmit the same ID as Button 1 or to transmit a unique ID. By default, Buttons 1 and 2 transmit the same ID number.
To change the ID of Button 2 to be unique:
1. Remove the battery from the remote.
2. Press any button to reset the remote.
3. Press 2 and install the battery until the red LED flashes quickly 5
times for 0.1 seconds.
Button 2 will now use transmit a unique ID (ID of Button 1 +1)
4. Close the cover.
To change the ID of Button 2 to use ID of Button 1:
1. Remove the battery from the remote.
2. Press any button to reset the remote.
3. Press 1 and install the battery until the red LED flashes quickly 5
times for 0.1 seconds.
Button 2 will now transmit the same ID as Button 1.
4. Close the cover.
4
Declaration of Conformity
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device may not cause harmful interference.
This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com
.
Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.
Contact Information
United States and Canada
Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd. Rosh HaAyin, Israel Tel: +972-3-938-6838 Fax: +972-3-938-6830 support.eu@rosslaresecurity.com
Latin America
Rosslare Latin America Buenos Aires, Argentina Tel: +54-11-4001-3104 support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86-755-8610-6842 Fax: +86-755-8610-6101 support.cn@rosslaresecurity.com
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852-2795-5630 Fax: +852-2795-1508 support.apac@rosslaresecurity.com
India
Rosslare Electronics India Pvt Ltd. Tel/Fax: +91-20-40147830 Mobile: +91-9975768824 sales.in@rosslaresecurity.com
www.rosslaresecurity.com
0706-0960503+04
Loading...