Rosslare SA-17 Installation Instructions Manual

SA-17
Installation Instructions
Wireless Rate-of-Rise Heat
Detector
1
0706-0960018+00
1. Introduction
The SA-17 Wireless Heat Detector is a supervised system for detecting hi g h tem peratures and sudden temperature increases within an area.
The detector can be used in any residential or commercial location, require s no wiring and is ful ly equipped for RF wireless control from a central security unit. The detector is easy to install and powered by one 9V battery, giving a typical battery life of on e year.
Mount the detector on the SA-13 RF base. Using the SA-13's wireless transmitter, the detector c an connect to any standard wireless security system. For best performance, Rosslare recommend using the SA-17 with our custom designed HomeLogiX and SP-03 wireless security panels. The SA-13 is powered b y an additional 9V battery.
The detector has anti-tampering sensors on its cover and back plate, and sends a standard status message to its host security panel ever y 20 minutes . When the unit's batte r y is running low ,
the unit beeps, flashes its LED indicator and sends an aler t message to its host control panel.
NOTE: The SA-17 Heat Detector is not designed as a substitute for a primary fire detection system.
2. Technical Specifications
2.1 Electrical Characteristics
Battery: IEC 6LR61 (9V Carbon-Zinc) or
IEC 6LF22 or MN1604 (9V Alkaline)
Detector Current Standby: 10µA
Alarm State: 10–15mA
Transmitter Current Standby: 16 µA
Transmitting: 16mA
Battery Life 1 year Low Battery
Detection
Last 7 days of battery lif e
2.2 Environmental Characteristics
Environment Indoor Use Operating Temperature: 0°C–40°C (32°F –104°F) Operating Humidity 10% to 90% Non-Condensing
2.3 Physical Characteristics
Alarm Temperature 70°C ±5°C Alarm Rate-of-Rise 12°C per minute Operation Indicators: LED and siren Siren Volume: 85dB at 3m (10ft) Dimensions: 48mm height, 107mm diameter
(1.89" height, 4.21" diameter)
Weight: 206 grams (7.266 oz)
2.4 Standards
USA: NFPA #74,
UL 217, FCC
Europe: CE,
ETSI
3. Installation
The SA-17 is a single station detector and must not be connected to other fire alarm systems.
3.1 Location
For full protection, every room should have a heat detector fitted. At the very least, a home built on a single storey should have at least one heat detector in the hall, close to all the living areas, including bedrooms and kitchens. Ensure the alert siren is audible from every room.
In a home wit h more than one sto r ey, at leas t one heat detector should be fitted on each landing and at the bottom of the staircase.
3.2 Mounting the Detector
Before mounting the SA-17 Heat Detector, ensu re that your chosen mounting area is not in front of any electrical wiring or pipe work.
Mark two mounting points in the wall, using the SA-13 mounting bracket.
Drill into the marked points and in sert wall p lu g s . Screw the mounting bracket into the wall. Be careful not to
over-tighten the screws. Insert a battery i nto the SA-17 Heat Detector and p ush down
the metal tab fully. Attach the detec tor to the mounting b ra c ket.
NOTE: Do not paint or cover the detector.
Test
Button
2
0706-0960018+00
4. Opera ting the Heat Detector
4.1 General Use
During normal operation, the heat detector's LED indicator should flash once a minu te.
When the unit records dangerously high temperatures or detects that the temperature in the area is incre asing at a dangerously high speed, it triggers its built-in siren. If the detector is connected to a wire less security network, it sends an alert message to the host security panel.
The siren stops when the temperature has fal len back below the danger level or the rate of temperature increase has slowed. An "all clear " message is sent to th e ho s t security panel.
As standard, the heat detector will trigger an alert when it detects tempe r atures of 70°C or more, or registers that the temperature is increasing at more than 12°C per minute. The trigger values are controlled by a factory setting and can be adjusted to meet specific client ne eds. Contact Rosslare Security for more information.
4.2 Testing the Detector
To test the Heat detector, pus h and hold the self-test button for 3 seconds. A loud pulsating siren sounds and the LED indicator flashes quickly.
Rosslare recommend testing your heat detector once every week. A Heat detector installed in a car or other non­commercial vehicle should be checked before any long journeys , and whenever t he vehicle has been in storage for an extended period of time.
4.3 Maintenance
Dust and dirt reduce the Heat detector's se n sitivity. Clean your heat detector regularly, by passing a vacuum cleaner with a brush attachment gently over the front grilled sections and sides of the heat detector.
When the detecto r ' s battery is low, the detector beeps once every minute. If the detector is connec ted to a wireless security network, it sends a low battery warning message to the host control panel.
The heat detector continues operating with a low battery for at least 7 days.
5. Limited Warranty
ROSSLARE ENTERPRISES LIMITED S (Rosslare) ONE YEAR LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's ONE YEAR LIMITED WARRANTY is subject to the following conditions:
Warranty
Warranty of Rosslare's products extends to the original purchaser (Customer) of the Rosslare product and is not transferable.
Products Covered By This Warranty and Duration
ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARIES (ROSSLARE) warrants that the SA-17 Wireless Heat Detector, to be free from defects in materials and assembly in the course of normal use and service. The warranty period commences with the date of shipment to the or igina l pur chas er an d ext ends for a pe rio d of 1 year (12 Months).
Warranty Remedy Coverage
In the ev en t o f a breach of warranty, ROSSLARE will credit Customer with the price of the Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by the Custome r durin g the warr anty per iod in accor dan ce with the term s of th is wa rran ty. Unless otherwise requested by ROSSLARE ENTERPRISES LTD. AND / OR SUBSIDIARIES representative, return of the failed product(s) is not immediately required. If ROSSLARE has not contacted the Customer within a sixty (60) day holding period following the delivery of the warranty claim, Customer will not be required to return the failed product(s). All returned Product(s), as may be requested at ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARY’S sole discretion, shall become the property of ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARIES. To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to obtain an RMA number after which, the product must be returned to the Manufacturer freight prepaid and insured In the ev en t ROS SL AR E ch o os es to p er f or m a pr oduct evaluation within the sixty (60) day holding period and no defect is found, a minimum US$ 50.00 or equivalent charge will be applied to each Product for labor required in the evaluation. Rosslare will repair or replace, at its discretion, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by Rosslare or a Rosslare authorized service center.
Exclusions and Limitations
ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is
incorporated. This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product that is used with any ancillary equipment, which is not furnished by ROSSLARE.
This warranty does not cover expenses incurred in the transportation, freight cost to the repair center, removal or reinstallation of the product, whether or not proven defective.
Specifically excluded from this warranty are any failures resulting from Customer's improper testing, operation, installation, or damage resulting from use of the Product in other than its normal and customary manner, or any maintenance, modification, alteration, or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defec ts or d ama ge due to lightning or other electrical discharge. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument, or any modification or abuse of, or tampering with, the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim.
ROSSLARE does not warrant the installation, maintenance, or service of the Product. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall Rosslare be liable for incidental or consequential damages.
Limited Warranty Terms
this warrant y set s for th the fu ll exten t of rosslare enterprises ltd. and its subsidiaries warranty.
the terms of this warranty may not be varied by any person, whether or not purporting to represent or act on behalf of rosslare.
this limited warranty is provided in lieu of all other warranties. all other warranties expressed or implied, inc lud ing without limita tion , implie d w arran t ies of mer chan tab ility an d fit ne ss fo r a particular purpose, are specifically excluded.
in no event shall rosslare be liable for damages in excess of the purchase price of the product, or for any other incidental, consequential or special damages, including but not limited to loss o f use , los s of time , com merc ial lo ss , incon v en ience , and loss of pro f its, arising out of the installation, use, or inability to use such product, to the fullest extent that any such loss or damage may be disclaimed by law.
this warranty shall become null and void in the event of a violation of the provisions of this limited warranty.
6. Contact i nformatio n
Asia Pacific, Middle East, Africa
Headquarters:
905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road, Kowloon Bay HK Tel: +852 2795-5630 Fax: +852 2795-1508 E-mail: support.apac@rosslaresecurity.com
United States and Canada
1600 Hart Court, Suite 103 Southlake, TX, USA 76092 Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 E-mail: support.na@rosslaresecurity.com
Europe
Global Technical Support & Training Center:
HaMelecha 22 Rosh HaAyin, Israel 48091 Tel: +972 3 938-6838 Fax: +972 3 938-6830 E-mail: support.eu@rosslaresecurity.com
South America
Pringles 868, 1640 Martinez Buenos Aires Argentina Tel: +54 11 4798-0095 Fax: +54 11 4798-2228 E-mail: support.la @rosslaresecurity.com Web Site: www.rosslaresecurity.com
Loading...