Rosslare PYR-2021 Installation Instructions Manual

PYR-2021
Installation Instructions Advanced Wired PIR
1 0706-0960111+01
The PYR-2021wired PIR is a high-performance intrusion sensor made with the highest level of SMD Components as well as Microprocessor Technologies making it ideal for both residential and commercial usage.
The PYR-2021's SSFL technology (look down) allows detection at proximity of 50cm from its mounting location.
The PYR-2021include selectable pulse counting as well as cover and wall tamper detection features. The PIR also features a removable Curtain adapter from inside the Lens that will allow the device to be used for focused detecting, such as across window surfaces or down corridors.
The following pages outline the installation and test instructions for your new PYR-2021 PIR.
2 Technical Specifications
2.1 Optical Characteristics
Lens Type: Spherical Field of view: 115° Max. Coverage: 14 x 14 m (46 x 46ft) No vertical adjustment
2.2 Electrical Characteristics
Input voltage: 9-16VDC Input Current: 15mA Indication: Red LED Alarm Signals: LED 3 seconds on, Relay Output. Relay Output: 35VDC 100mA max N.C. Detector: Dual-element low-noise pyroelectric sensor. Sensitivity modes: 2 interchangeable modes, low and high Sensitivity t= 1.1 C @ 0.9 m/sec ( t= 2 F @ 3 ft /sec)
2.3 Environmental Characteristics
Operating Environment: indoor use Operating Temperature: -10°C to 50°C (14°F to 122°F) Operating Humidity: 0 to 95% (Non-Condensing) RFI Protection: >20 V/m up to 1000 MHz.
2.4 Physical Characteristics
Dimensions: 127mm(5 in)H x 80mm(3.15 in)Wx63mm(2.48 in)D
(Fits US Gang Box)
Weight: 0.25 lbs (112g) Compliance with standard: TBD
2 0706-0960111+01
3 Installation
3.1 General
The PYR-2021 is designed for easy installation. Only a few steps are required to install the PIR device.
To enable the Curtain Adapter for PIR detection on a focused area, such as a corridor, or across a window or opening, follow the instruction outlined in section 4.
When you are sure of the mounting location, follow the steps for mounting the PIR, on a flat surface or in a corner, described below.
3.2 Opening the PYR-2021
The PYR-2021 housing can be opened by unscrewing a Philips­head screw (1) and pushing the safety latch (2) to “unlock”.
Removing the Lens
You will need to remove the lens only to add or remove the Curtain Adapter.
1) Turn the top part of the PYR-2021 over and locate the
“holder pin” (A) for the lens.
2) Use a screwdriver to gently pop it out by putting the edge
under the “holder pin” and pushing down on the handle.
3) Turn the housing over and pop off the lens.
3.3 Wiring the PYR-2021PIR
The PYR-2021 is wired using a terminal block with binding posts that are opened using a thin Philips head screwdriver or a flat head screwdriver and located on the front of the PCB (see PCB image below in the jumper section)
The terminal block consists of two Normally closed alarm relay binding posts, followed by two Tamper binding posts and closed off with a + and – 12VDC binding posts
Connect all the Signaling Cables first.
Wire the power last.
NOTE! When laying wires to the control panel ensure that they are not in parallel with high voltage mains or other high potential wiring as this may cause false alarms.
3.4 Mounting the PYR-2021PIR
Select an area for mounting the PYR-2021, and ensure the location is flat, either a wall or a 90-degree corner, for perfect mounting of the unit. Ensure the PIR has a “view” of the area under surveillance and is free from obstructions.
The PYR-2021 has a detection range of 14.7m (48 ft.) when placed at a height of between 1.8m and 2.3m.
3.5 Wall Mounting
The PIR housing has “dimple” points for insertion of screws, for either wall-mounting or corner mounting (refer to detailed pictures below). Remove the PC board prior to mounting.
NOTE: Be careful not to touch the pyro-electric unit on the board. Touching the unit will gravely affect its ability of the unit to work properly.
Alarm N
.C
RLY
Tamper
12VDC
To panel From panel
1
2
A
Dimples for Flat
Wall Mounting
Dimples for
Corner Mounting
Dimples for
Corner Mounting
Optional corner bracket
3 0706-0960111+01
4 Adding the Curtain Adapter
Use the Curtain Adapter when the need for detecting movement in narrow places (corridors) or across surfaces (window).
1) Place the Curtain Adapter onto the lens area on the front
of the housing. Be sure to place the guide pins into the two holes at the lower part of the lens area.
2) Replace the Lens
3) Turn the whole assembly over and replace the “holding
pin” that holds the Spherical lens in place. Be sure to place the “holding pin” between the lens tab and the housing, with the flat side toward the lens tab.
5 Jumpers and Back Tamper Setting
The PYR-2021 has 2 internal jumpers that can be connected to enable various features, allowing the unit to be versatile for any usage situation.
5.1 Back Tamper
The PYR-2021 has both front and back tamper detection. Front tamper detection is on by default it is activated when the
panel is opened cannot be changed. The back tamper detection is activated when the detector is pulled off the wall and is disabled by default, to enable the back tamper detection cut the back tamper jumper (JP2).
5.2 Detection Sensitivity Jumper
In harsh environment conditions the sensor may detect false alarms, in order to prevent these false alarms; two sensitivity modes were designated, “Low” for regular usage and “High” for high sensitivity when there is little chance for false alarms.
The JS2 Jumper changes the detection sensitivity between the two settings, Low or High.
Low Sensitivity (normal), with jumper High Sensitivity, no jumper
5.3 LED Enable / Disable Jumper
In the event that you wish to disable the LED, you can do so using the JP1 jumper.
When the jumper is closed (default), the LED is enabled. When the jumper is open, the LED is disabled.
LED Disabled, no jumper LED Enabled, with jumper
6 Testing the Detector
To test the detection ability of the PYR-2021 at a certain location, it is necessary to perform a walk tests to ensure coverage.
After connecting the detector to the power and adjusting for the required sensitivity, insert LED jumper (JP1). Close the front cover and go to the farthest distance from the
detector. Start to walk parallel to the detector. See that the red LED goes on and off. Do the same in anther location. After a successful walk test open the front cover again and remove JP1 jumper. Close again with the screw.
It is recommended performing a walk test on a weekly basis
Curtain Adaptor
Lens
JS2 sensitivity Jumper
JP1 LED Jumper
JP2 Back Tamper Jumper
Test Mode Reed Switch
Front Cover Tamper
PIR Sensor
LED
12VDC
+ -
Alarm
NC RLY
Tamper
4 0706-0960111+01
7 Limited Warranty
ROSSLARE ENTERPRISES LIMITED S (Rosslare) ONE YEAR LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's ONE YEAR LIMITED WARRANTY is subject to the following conditions:
Warranty
Warranty of Rosslare's products extends to the original purchaser (Customer) of the Rosslare product and is not transferable.
Products Covered By This Warranty and Duration
ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARIES (ROSSLARE) warrants that the PYR-2011 Advanced wired PIR, to be free from defects in materials and assembly in the course of normal use and service. The warranty period commences with the date of shipment to the original purchaser and extends for a period of 1 year (12 Months).
Warranty Remedy Coverage
In the event of a breach of warranty, ROSSLARE will credit Customer with the price of the Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty. Unless otherwise requested by ROSSLARE ENTERPRISES LTD. AND / OR SUBSIDIARIES representative, return of the failed product(s) is not immediately required. If ROSSLARE has not contacted the Customer within a sixty (60) day holding period following the delivery of the warranty claim, Customer will not be required to return the failed product(s). All returned Product(s), as may be requested at ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARY’S sole discretion, shall become the property of ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARIES. To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to obtain an RMA number after which, the product must be returned to the Manufacturer freight prepaid and insured In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day holding period and no defect is found, a minimum US$ 50.00 or equivalent charge will be applied to each Product for labor required in the evaluation. Rosslare will repair or replace, at its discretion, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by Rosslare or a Rosslare authorized service center.
Exclusions and Limitations
ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated. This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product that is used with any ancillary equipment, which is not furnished by ROSSLARE. This warranty does not cover expenses incurred in the transportation, freight cost to the repair center, removal or reinstallation of the product, whether or not proven defective. Specifically excluded from this warranty are any failures resulting from Customer's improper testing, operation, installation, or damage resulting from use of the Product in other than its normal and customary manner, or any maintenance, modification, alteration, or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defects or damage due to lightning or other electrical discharge. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument, or any modification or abuse of, or tampering with, the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim. ROSSLARE does not warrant the installation, maintenance, or service of the Product. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall Rosslare be liable for incidental or consequential damages.
Limited Warranty Terms
THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD
. AND ITS SUBSIDIARIES WARRANTY
THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON, WHETHER OR NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE
.
THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES
. ALL OTHER WARRANTIES EXPRESSED OR IMPLIED,
INCLUDING WITHOUT LIMITATION
, IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
, ARE
SPECIFICALLY EXCLUDED
.
IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT
, OR FOR ANY OTHER INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES
, INCLUDING BUT NOT LIMITED TO
LOSS OF USE
, LOSS OF TIME, COMMERCIAL LOSS, INCONVENIENCE, AND
LOSS OF PROFITS
, ARISING OUT OF THE INSTALLATION, USE, OR INABILITY
TO USE SUCH PRODUCT
, TO THE FULLEST EXTENT THAT ANY SUCH LOSS
OR DAMAGE MAY BE DISCLAIMED BY LAW
.
THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE PROVISIONS OF THIS LIMITED WARRANTY
.
8 Contact information
Asia Pacific, Middle East, Africa
Headquarters:
905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road, Kowloon Bay Hong Kong Tel:+852 2795-5630 Fax: +852 2795-1508 E-mail: support.apac@rosslaresecurity.com
United States and Canada
1600 Hart Court, Suite 103 Southlake, TX, USA 76092 Tool Free:+1-866-632-1101 Local:+1-817-305-0006 Fax: +1-817-305-0069 E-mail: support.na@rosslaresecurity.com
Europe
Global Technical Support & Training Center:
HaMelecha 22 Rosh HaAyin, Israel 48091 Tel: +972 3 938-6838 Fax: +972 3 938-6830 E-mail: support.eu@rosslaresecurity.com
South America
Pringles 868, 1640 Martinez Buenos Aires Argentina Tel: +54 11 4798-0095 Fax: +54 11 4798-2228
Web Site: www.rosslaresecurity.com
Loading...