ME-14
Compact Single Board Self-Powered Enclosure
Installation Manual
1. Introduction
The ME-14 is a simple plastic enclosure suited for a singular PCB and
Rosslare’s BT-16 backup battery. The ME-14 boasts two tamper triggers,
one for the back case detecting wall detachment and one for the casing
itself detecting attempts to open the encasement.
The enclosure is suitable for any one of Rosslare’s ExpansE units, EXP1032 Network Controller known as an MU, and the various EUs: EXP2024 Dual Reader Door Unit, EXP-2016 16-Relay Elevator Control Unit,
EXP-2088 – 8-Input/Output Interface, as well as Rosslare’s MD-W11
Wireless Access Control Door Interface.
Figure 1: ME-14
2. Technical Specifications
2.1 Electrical Characteristics
Power
From External source
Backup battery
BT-16
The backup battery has no external power source and has no
charger available, once the backup battery is depleted it needs
to be replaced.
2.2 Environmental Characteristics
Operating Environment
Indoor use
Operating Temperature Range
-10°C to 50°C (14°F to 122°F)
Operating Humidity Range
0 to 95% (non-condensing)
2.3 Physical Characteristics
Dimensions (H x W x D)
130 x 180 x 40 mm (5.1 x 7.1 x 1.6 in.)
Weight
200 g (7 oz.)
3. Installation
3.1 General
The ME-14 is designed for easy installation. Only a few steps are required
to wire the chosen PCB, install it in the case and mount it onto the wall.
1. Unscrew the three Philips-head screw located on the bottom of the
unit and push the safety latches to “unlock”.
2. Open the case upwards in accordance with the notches located on
the top of the case.
3. Use the designated notches to install the PCB and backup battery
into the ME-14 case.
4. Wire the unit being installed according to the wiring instructions as
explained in the relevant installer manual.
5. Mount the PCB into the designated area; align the PCB holes with
those of the encasement.
6. Mount the backup battery (optional) onto the designated location on
the top right side of the encasement.
Figure 2: ME-14 Assem bly
3.2 Mounting the ME-14
Select an area for mounting the ME-14, and ensure the location is flat,
for perfect mounting of the unit. When using the ME-14 with the MDW11, make sure to mount the ME-14 in a location suited for wireless
reception.
1. Using the holes dimensions and locations shown in Figure 2, drill
holes in the wall. Alternatively, use the ME-14’s back plate as a
template.
2. Insert masonry anchors into the drilled holes.
3. Mount the PCB into the designated area; align the PCB holes with
those of the encasement.

4. Mount the backup battery (optional) onto the designated location on
the top right side of the encasement
5. Thread the wires through the designated holes in the rear of the
case..
6. Mount the ME-14 onto the wall.
7. Secure the screws. Make sure to thread a screw into the wall tamper
screw hole.
8. Close and secure the enclosure.
Figure 3: ME-14 Mounting Template
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick
Links section on the ROSSLARE website at www.rosslaresecurity.com
.
Rosslare considers any use of this product as agreement to the
Warranty Terms even if you do not review them.
Contact Information
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd.
Kowloon Bay, Hong Kong
Tel: +852 2795-5630
Fax: +852 2795-1508
support.apac@rosslaresecurity.com
United States and Canada
Rosslare Security Products, Inc.
Southlake, TX, USA 76092
Toll Free: +1-866-632-1101
Local: +1-817-305-0006
Fax: +1-817-305-0069
support.na@rosslaresecurity.com
India
Rosslare Electronics India Pvt Ltd.
Tel/Fax: +91-20-40147830
Mobile: +91-9975768824
sales.in@rosslaresecurity.com
Europe
Rosslare Israel Ltd.
Rosh HaAyin, Israel 48091
Tel: +972 3 938-6838
Fax: +972 3 938-6830
support.eu@rosslaresecurity.com
Latin America
Rosslare Latin America
Buenos Aires, Argentina
Tel: +54-11-4001-3104
support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd.
Shenzhen, China
Tel: +86 755 8610 6842
Fax: +86 755 8610 6101
support.cn@rosslaresecurity.com
www.rosslaresecurity.com
0706-0960426+01