Rosslare ME-01P14, ME-12P14 Installation Manual

ME-01P14
Single-Board Self-Powered Metal Enclosure
Installation Manual
1
1. Introduction
The ME-01P14 Single-Board Self-Powered Metal Enclosure is a sturdy, lockable, metal case that has room for a single PCB board along with a power supply and backup battery.
The ME-01P14 is suitable for the various ExpansE™ units, EXP-1032 Network Controllers known as an MU, and the various EUs: EXP-2024 Dual Reader Door Unit, EXP-2016 16-Relay Elevator Control Unit, and EXP-2088 – 8-Inputs/Outputs Interface. In addition, it is suitable for use with Rosslare’s AC-215, AC-225, and AC-425 access control units.
Figure 1: ME-01P14
2. Technical Specifications
2.1 Electrical Characteristics
Power
110/220 VAC (from Rosslare’s PS-14)
Backup Battery
12 V, 7 Ah
2.2 Environmental Characteristics
Operating Environment
Indoor
Operating Temperature Range
-10°C to 50°C (14°F to 122°F)
Operating Humidity Range
0 to 95% (non-condensing)
2.3 Physical Characteristics
Dimensions (L x W x H)
300 x 280 x 50 mm (11.8 x 11 x 2 in.)
Weight
700 g (1.55 lb)
3. Installation
3.1 Installing the ME-01P14
Wire the power, backup battery, and tamper as described below.
To install the ME-01P14:
1. Connect the PS-14 power supply to the power terminal block (Figure 2).
Figure 2: Power Supply Wiring
2. Connect the backup battery to the battery terminal block.
3. Connect the ME-01P14’s tamper switch to the PCB’s tamper input terminal block.
4. Wire the unit being installed according to the wiring instructions as explained in the relevant installer manual.
5. Place the PCB and secure it using the designated holes and spacers clearly marked on the inside of the enclosure.
6. Thread the wires through the designated holes and springs (Figure
3).
Figure 3: ME-01P14 Unit Mounting and In-Box Connections
2
3.2 Mounting the ME-01P14
When selecting an area for mounting the ME-01P14, ensure the location is flat.
To mount the ME-01P14:
1. Using the holes dimensions and locations shown in Figure 4, drill holes in the wall.
Figure 4: ME-01P14 Mounting Template
2. Insert masonry anchors into the drilled holes.
3. Mount the ME-01P14 enclosure onto the wall as shown in Figure
5.
Figure 5: ME-01P14 Wall Mounting
4. Mount the board in the enclosure using the spacers supplied.
5. Connect the in-box power and backup battery as explained in Section 3.2.
6. Close and secure the enclosure.
3
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com
.
Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.
Contact Information
United States and Canada
Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd. Rosh HaAyin, Israel Tel: +972-3-938-6838 Fax: +972-3-938-6830 support.eu@rosslaresecurity.com
Latin America
Rosslare Latin America Buenos Aires, Argentina Tel: +54-11-4001-3104 support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86-755-8610-6842 Fax: +86-755-8610-6101 support.cn@rosslaresecurity.com
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852-2795-5630 Fax: +852-2795-1508 support.apac@rosslaresecurity.com
India
Rosslare Electronics India Pvt Ltd. Tel/Fax: +91-20-40147830 Mobile: +91-9975768824 sales.in@rosslaresecurity.com
www.rosslaresecurity.com
0706-0960424+0
1
Loading...