Rosslare MD-08, MD-12C/W Installation And User Manual

MD-08
Wiegand to RS-232 Output Converter
Installation and User Manual
1
1. Introduction
The MD-08 is an easy-to-use Wiegand to RS-232 converter. It allows you to connect a Wiegand reader directly to one of your PC’s COM ports. The MD-08 allows you to set employee and system codes without having to use a reader attached to a controller in the network.
Figure 1: MD-08
2. 1BTechnical Specifications
2.1 4BElectrical Characteristics
Power Supply
Either 2 terminal blocks or a DC jack. A reader can use a sink up to 100 mA
Electrical Sink
Up to 100 mA
Operating Voltage
9 to 15 VDC
Maximum Voltage
18 VDC
Input Current @ 12 V
10 to 12 mA (without reader)
Serial Interface
Standard DB9 female
2.2 5BEnvironmental Characteristics
Operating Environment
Indoor use only
Operating Temperature Range
0°C to 63°C (32°F to 145°F)
Operating Humidity Range
0 to 95% (non-condensing)
2.3 6BPhysical Characteristics
Dimensions
66 x 80 mm (2.60 x 3.15 in.)
Weight
75 g (2.6 oz)
3. 2BConnecting to the MD-08
You must use the AxTraxNG software to enroll cards. Please refer to the relevant appendix in the
AxTraxNG™ Software
Installation and User Manual
.
There are three ways to attach Wiegand readers to the MD-08:
Wiring a reader directly to the MD-08’s terminal block (Figure 2) Attaching a Rosslare reader directly to the MD-08’s connector
input (Figure 3)
Installing Rosslare’s MD-12W Proximity Reader Module directly into
the MD-08 (Figure 4)
Figure 2: MD-08 Terminal Block Wiring
Figure 3: MD-08 Connector to Reader
(Readers are not provided with the MD-08 and must be purchased separately.)
Figure 4: MD-12W to MD-08
(The MD-12W is not provided with the MD-08 and must be purchased separately.)
4. 3BCommunication Settings
The communication settings are 9600 baud, 8 bits, 1 stop bit and no parity.
The message is in the following format:
SS 02 FF 02 FF 00 0E 29 YY DD XX
Where:
SS is the start frame: FF, FF, FF, 55 YY is the number of Wiegand reception bits (in hexadecimal base)
XX is the message check sum (without the start frame) DD is the incoming Wiegand bits data up to 96.
For less than 96 bits (for example 26-Bit only), the data contain leading zeroes (70 leading zeroes for Wiegand 26-Bit).
2
0706-0960578+00
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com
.
Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.
Contact Information
United States and Canada
Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd. Rosh HaAyin, Israel Tel: +972-3-938-6838 Fax: +972-3-938-6830 support.eu@rosslaresecurity.com
Latin America
Rosslare Latin America Buenos Aires, Argentina Tel: +54-11-4001-3104 support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86-755-8610-6842 Fax: +86-755-8610-6101 support.cn@rosslaresecurity.com
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852-2795-5630 Fax: +852-2795-1508 support.apac@rosslaresecurity.com
India
Rosslare Electronics India Pvt Ltd. Tel/Fax: +91-20-40147830 Mobile: +91-9975768824 sales.in@rosslaresecurity.com
CERT
ISO 9001 ISO 14001
Loading...