Rosslare DRU955BT User Manual

DR-U955BT
SMART
Multi-format Desktop Reader
User Manual
1. Introduction
The DR-U955BT is an advanced desktop reader for MIFARE Classic® EV1, MIFARE the credential, and transmits the relevant ID data to any connected access control software, such as Rosslare’s AxTraxNG™.
It has a slim and attractive design and is built for convenience and portability. With its USB computer interface, it is quick and easy to install and runs without any additional power source.
Using the BLE-Admin or BLE-ID apps, the reader can function like other Rosslare BLE readers and can transmit the BLE ID to the reader.
The Hardware Configuration Tool (HCT) can be used to configure the reader’s specifications, such as the Wiegand format used.
The reader reads the CSN ID of each credential (MIFARE, UHF, BLE) and transmits it to the software with the bit length pre-configured by the user.
®
DESFire® EV1, UHF, and BLE. It reads the ID data of
2. Technical Specifications
2.1 Electrical Characteristics
Operating Voltage Range 5 VDC (USB powered)
Standby Current 250 mA
Max. Operation Current 300 mA
Supported Transponders MIFARE, UHF, BLE
Read Card Distance UHF and MIFARE: Up to 5 cm (2 in.)
BLE: Up to 6 m (19.7 ft)
Operation Frequency
Output Formats Supports Wiegand 26-Bit to 64-Bit
RFID: 13.56 MHz
DR-U955BT US: 902–928 MHz
(America) RFID
DR-U955BT EU: 865–868 MHz (Europe) RFID
Bluetooth: 2.402-2.480 GHz
Figure 1: DR-U955BT
2.2 Environmental Characteristics
Operating Environment Indoor use
Operating Temperature Range
Storage Temperature Range -20°C to 63°C (-4°F to 145°F)
Relative Humidity Range 0 to 95% (non-condensing)
-20°C to 63°C (-4°F to 145°F)
2.3 Physical Characteristics
Weight 130 g (4.6 oz)
Dimensions (L x W x H) 123 x 70 x 16.2 mm (4.9 x 2.8 x 0.6 in.)
3. Operation
The DR-U955BT appears as a COM port device when plugged in to a PC and can be used for any application. When a card is presented to the reader, the reader outputs the Wiegand ID data on the COM port only once until a new card is presented.
You must use the AxTraxNG software to enroll cards. Please refer to the relevant appendix in the AxTraxNG™ Software Installation and User Manual.
For the enrollment reader to function in AxTraxNG, you must know the COM port being used. The COM port can be found in Microsoft Device Management’s driver details under ‘Ports (COM & LPT)’. The port being used appears as “USB serial Port (COMx)”, where x is the number of the port used.
1
Declaration of Conformity
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions:
This device may not cause harmful interference.This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Limited Warranty
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for
help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment . This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operate
d with minimum distance
20cm between the radiator &you body.
The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at
www.rosslaresecurity.com
.
Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.
Contact Information
United States and Canada
Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd. 22 Ha'Melacha St., P.O.B. 11407 Rosh HaAyin, Israel Tel: +972-3-938-6838 Fax: +972-3-938-6830 support.eu@rosslaresecurity.com
Latin America
Rosslare Latin America Buenos Aires, Argentina support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86-755-8610-6842 Fax: +86-755-8610-6101 support.cn@rosslaresecurity.com
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852-2795-5630 Fax: +852-2795-1508 support.apac@rosslaresecurity.com
India
Rosslare Electronics India Pvt Ltd. Tel/Fax: +91-20-40147830 Mobile: +91-9975768824 sales.in@rosslaresecurity.com
CERT
ISO 9001 ISO 14001
2
0706-0960664+00
Loading...