Rosslare AY-Z12A Installation Manual

Page 1
Long range Multi Reader
Installation Guide
December 2010
AY-Z12A
Page 2
Page 3
Table of Contents

Table of Contents

1. Introduction ................................................................ 3
2. Technical Specific a ti ons ............................................... 4
3. Installation .................................................................. 5
3.1 The Installation Kit.................................................... 5
Installing the AY-Z12A Long Range Reader: ............ 5
3.2
3.2.1. Single Reader Installatio n ................................................ 6
Mu lt iple Reader Installation ............................................. 7
3.2.2.
3.2.3. Installation process .......................................................... 7
4. Wiring and Configuration Instructions ......................... 8
4.1 Wiring instructions .................................................... 8
4.2 Single Reader Configuration ................................... 9
4.3 Multiple Reader Configuration .............................. 10
5. Operation Instr uctions .............................................. 11
Appendix A. Limited Warranty ..................................... 12
Appendix B. Techn ical Su pp ort ..................................... 14
Page 4

Introduction

1. Introduction

The AY-Z12A Long-range Reader is an RFID proximity card reader, utilized with access control systems. The reader can function in one of two scenarios

Single reader installation ( default)
Multiple readers installation

Figure 1 The AY-Z12A Long-Range Reader

This Manual contains the following information:

Installation
Wiring Instructions
Operation Instructions
AY-Z12A Installation Manual Page 3
Page 5

Technical Specifications

Electrical Characteristics

Power Supply Type

Linear type - recommended

Operating Vo ltage Range

10 - 16VDC

Absolute Maximum (non-operating)

Input Current

Tamper Output

Open collector, active low, max. sink current 30mA

Maximum Cable Distance

500 ft (150 meters)

Card Read Di s tance

Weigand 26 output format with a range*

Environmental Characteristics

Operating Temp. Range

-22°F to 145° F (-30°C to 63°C)

Operating Humidity

0 – 95% (non-condensing) Suitable for outdoor use (IP54)

Dimensions

Height x Width x Depth Weight

2.35 Lbs. (1066g)

2. Technical Specifications

18VDC

Standby: 280mA Read: 330mA
23.6" (60 cm) maximum read

11.81" x 11.81" x 1.0" 300mm x 300mm x 25.4 mm

* For maximum range set the reader as a single reader, use Rosslare’s AT-R14 clamshell proximity card, as well as a 16 V power supply and ensure that the installation is as far possible from any additional electrical devices and that it is not in proximity to any metal.
Page 6
Installation

3. Installation

3.1 The Installation Kit

The Installation kit comprises of the following items used during the installation procedure:

One Installation Template
Four pan head screws & wall plugs
One L shaped security screw tool
Three Security screws

3.2 Installing the AY-Z12A Long Range Reader:

Figure 2: Removing th e Top Co ver

Figure 2 shows the front view of the AY-Z12A Long-Range Reader. When installing the reader, you must remove the sn ap-o ff cover to
access the screw holes.
AY-Z12A Installation Manual Page 5
Page 7
Installation

The Reader must be mounted with the appropriate screw s (not supplied), as described in the template provided.

Installing the unit on metal surfaces will reduc e t h e r ead ra n ge considerably, to decrease t he affect of the metal surface use Rosslare’s MP-Z02 Spacer (sold separately) as described in the image below for a max range of 43cm (17 inch).

Figure 3: Install in g th e unit with the MP-Z02 s pacer

3.2.1. Single Reader Installation

The AY-Z12A Long-Range Reader is designed to function with the best performance when installed isolated fro m other AY-Z12A long range readers at least in a range of 2-4 meters, the reader is therefor preconfigured as a single installation reader. See Single Reader Configuration, on page 9, for detailed configuration instructions.
Page 8
Installation

3.2.2. Multiple Reader Installation

Although designed to work in an isolated environment, it is possible to ins tall multip le r eaders within a range of 2-4 meters, however the read range will reduce by 20-30 percent.

When installing multiple readers, configure each of the readers in the close environment for multiple reader insta llation.

We do not recommend multiple readers be installed less than two (2) meters apart due to r edu ced range caused by inter ference between readers.

See Multiple Reader Configuration, on page 10, for detailed configuration instructions.

3.2.3. Installation process

The physical installation of the unit is described below.

To Install the Reader:

1. Determine an approximate location for th e installation of the Reader.

2. Peel off the back of the self-adhesive installation label template and locate it at the required location.

3. Using the template as a guide, drill holes (the size of which are indicated in the template) to install the Reader or spacer onto the surface.

4. Drill a 7/16” (10mm) ho le for the cable. In the event that you are installing the reader on metal, place a grommet or electrical tape around t h e ed g e of the hole and use the MP­Z02 spacer.

5. Route the interface cab le from the Reader to the Cont r oller. A linear type power supply is recommended.

AY-Z12A Installation Manual Page 7
Page 9
Wiring and Configuration Instructions

Reader

Color

Weigand Output

10~16 VDC

Red

DC+Input

Data 1

White

Data 1

Data 0

Green

Data 0

LEDCTL

Brown

LED Control

Tamper

Purple

Tamper

4. Wiring and Configuration Instructions

Follow the wiring and configuration instructions below based on the installation type you are utilizing.

4.1 Wiring instructions

The AY-Z12A Reader is supplied with an 18” pigtail, comprising a 6­conductor cable.

To connect the Reader to the Controller:

1. Prepare the Reader cable by cutting its jacket back 1¼” an d strip the insulation from the wires, ½”.

2. Prepare the Controller c able by cutting its jacket bac k 1¼” and strip the insulation from the wires, ½”.

3. Splice the Reader’s pigtail wires to the correspond ing Controller wires and cover each joint with insulating tape.

If the tamper output is being utilized, connect the purple wire to the correct input on the Controller.

Shield / Ground Black Ground

4. Trim and cover all unused conductors.

Page 10
Wiring and Configuration Instructions

Note:

connection at the panel,
The individual wires from the Reader are color-coded according
the Wiegand standard.
When using a separate power supply for the Reader, this supply
and that of the Controller, must have a common ground.
The Reader’s cable shield wire should preferably be attached
to an earth ground, or a signal ground or power supply end of the cable. This configuration is best for shielding the Reader cable from external interference

4.2 Single Reader Configuration

For single reader installation, follow the configuration process below, this process is not required with new readers as it comes preconfigured from the factory to function as a single door reader.

To configure a single reader installation mode:

1. Turn the reader power OFF

2. Connect the Data 1 wire (White cable) to Grou n d .

3. Leave the LED Control wire (Brown cable) floating.

4. Turn the reader power ON

5. Connect the LED Control wire (Brown cable) to Ground.

6. Release the LED Control wire from the Ground.

7. The Reader’s LED starts flashing continuously and the Buzzer sounds.

8. Turn the reader power OFF

9. Disconnect the Data 1 wire (White cable) from the Ground.

10. The Reader configuration for single reader installation is complete.

.
– Reader LED turns Orange.
.
AY-Z12A Installation Manual Page 9
Page 11
Wiring and Configuration Instructions

4.3 Multiple Reader Configuration

To install multiple readers follow the configuration pro cess below.

To configure a multiple reader installation mode:

1. Turn the reader power OFF

2. Connect the Data 1 wire (White cable) to Ground.

3. Connect the LED Contro l wire (Brown cable) to Gro u n d .

4. Turn the reader power ON

5. Release the LED Control wire from the Ground.

6. Reconnect the LED Control wire (Brown cable) to Grou n d .

7. The Reader’s LED starts flashing continuously and the Buzzer sounds.

8. Turn the reader power OFF

9. Disconnect the Data 1 wire (White cable) from the Ground.

10. The Reader con figuration for multiple reader installation is complete. You can now connect two or three readers within a 2-4 meter range from one ano ther.

.
– Reader LED turns Oran g e.
.
Page 12
Limited WarrantyOperation Instructions

5. Operation Instructions

Test the AY-Z12A long-range reader after wiring it to a power supply and a Controller.

To test the Reader:

1. Power up the Reader. The LED flashes on power up, and the Beeper sounds twice, at which point it begins an auto­calibration procedure, this can take up to two seconds, when the calibration is comp lete a third beep will sound , thus indicating that the Reader is working properly. The LED returns to its idle state (red).

2. Present the appropriat e t ype of proximity card to the R ead er. The LED will flash green briefly and a s h o rt beep is emitted, thus indicating that the card was read proper ly.

The Reader transmits the card's data to the Controller; the Controller checks the data, if the card transmission is valid, the LED changes briefly to green. Refer to the Controller’s description of LED operation for Controllers with Reader LED control. The LED then returns to its idle state ( red )
The range is measured us ing a Rosslare Proximity Card (P/N AT­11/12) or equivalent. Th e ran g e also depends on electrica l environment and/or proximity to metal.
AY-Z12A Installation Manual Page 11
Page 13
Limited Warranty

Appendix A. Limited Warranty

ROSSLARE ENTERPRISES LIMITED S (Rosslare) FIVE YEARS LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's FIVE YEARS LIMITED WARRANTY is subject to the following conditions:

Warranty

Warranty of Rosslare's products extends to the original purchaser (Customer) of the Rosslare product and is not transferable.

Products Covered By This Warranty and Durati on

ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARIES (ROSSLARE) warrants that the AY-Z12A RFID long-range proximity card Reader, to be free from defects in materials and assembly in the course of normal use and service. The warranty period commences with the date of shipment to the original purchaser and extends for a period of 5 years (60 Months).

Warranty Remedy Coverage

In the event of a breach of warranty, ROSSLARE will credit Customer with the price of the Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty. Unless otherwise requested by ROSSLARE ENTERPRISES LTD. AND / OR SUBSIDIARIES representative, return of the failed product(s) is not immediately requi red. If ROSSLARE has not contacted the Customer within a sixty (60) day holding period following the delivery of the warranty claim, Customer will not be required to return the failed product(s). All returned Product(s), as may be requested at ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARY’S sole discretion, shall become the property of ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARIES. To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to obtain an RMA number after which, the product must be returned to the Manufacturer freight prepaid and insured In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day holding period and no defect is found, a minimum US$ 50.00 or equivalent charge will be applied to each Product for labor required in the evaluation. Rosslare will repair or replace, at its discretion, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by Rosslare or a Rosslare authorized service center.
Page 14
Limited Warranty

Exclusions and Limitations

ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated. This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product that is used with any ancillary equipment, which is not furnished by ROSSLARE. This warranty does not cover expenses incurred in the transportation, freight cost to the repair center, removal or reinstallation of the product, whether or not proven defective. Specifically excluded from this warranty are any failures resulting from Customer's improper testing, operation, installation, or damage resulting from use of the Product in other than its normal and customary manner, or any maintenance, modification, alteration, or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defects or damage due to lightning or other electrical discharge. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument, or any modification or abuse of, or tampering with, the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim. ROSSLARE does not warrant the installation, maintenance, or service of the Product. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall Rosslare be liable for incidental or consequential damages.

Limited Warranty Terms

THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD. AND
S SUBSIDIARY'S WARRANTY
IT
189BTHE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON, WHETHER OR
NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE
190BTHIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES. ALL OTHER
WARRANTIES EXPRESSED OR IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SPECIFICALLY EXCLUDED
191BIN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE
PURCHASE PRICE OF THE PRODUCT CONSEQUENTIAL OR SPECIAL DAMAGES
, LOSS OF TIME, COMMERCIAL LOSS, INCONVENIENCE, AND LOSS OF PROFITS,
USE ARISING OUT OF THE INSTALLATION THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE DISCLAIMED BY LAW
192BTHIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE
PROVISIONS OF THIS LIMITED WARRANTY
.
, INCLUDING WITHOUT LIMITATION, IMPLIED
, OR FOR ANY OTHER INCIDENTAL,
, INCLUDING BUT NOT LIMITED TO LOSS OF
, USE, OR INABILITY TO USE SUCH PRODUCT, TO
.
.
, ARE
.
AY-Z12A Installation Manual Page 13
Page 15

Appendix B. Technical Support

Asia Pacific, Middle East, Africa

Rosslare Security Products Headquarters 905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road, Kowloon Bay Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 E-mail:

United States and Canada

1600 Hart Court, Suite 103 Southlake, TX, USA 76092 Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 E-mail:

Europe

Global Technical Support & Training Center HaMelecha 22 Rosh HaAyin, Israel 48091 Tel: +972 3 938-6838 Fax: +972 3 938-6830 E-mail:

South America

Presbitero Actis 555, Oficina 31. San Isidro. Buenos Aires. Argentina Tel: +5411-5273-6383 Tel: +305-921-9919 E-mail:

Web Site: www.rosslaresecurity.com

support.apac@rosslaresecurity.com
support.na@rosslaresecurity.com
support.eu@rosslaresecurity.com
support.la@rosslaresecurity.com
Technical Support
Loading...