Rosslare AYR6255 User Manual

AY-R6255
Illuminated RFID Reader
Installation and Operational Manual
Copyright © 2015 by Rosslare. All rights reserved.
This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
Table of Contents
Table of Contents
1. Introduction ................................................................ 7
2. Technical Specifications .............................................. 8
3. Mounting Instructions ................................................ 9
4. Wiring Instructions ................................................... 10
5. Operating Instructions .............................................. 12
5.1 Lighting ................................................................................ 12
5.2 DIP Switch Settings for Output and Input Formats ................... 13
6. Testing the Reader .................................................... 14
A. Limited Warranty ...................................................... 15
AY-R6255 Installation and Operation Manual iii
List of Figures
List of Figures
Figure 1: Mounting Template ............................................................................ 9
iv AY-R6255 Installation and Operation Manual
List of Tables
List of Tables
Table 1: Wiring Colors ..................................................................................... 10
Table 2: Operations Table ................................................................................ 12
Table 3: Output Format ................................................................................... 13
Table 4: Read Format....................................................................................... 13
AY-R6255 Installation and Operation Manual v
Notice and Disclaimer
Notice and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product described herein.
B
EFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND THE
USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING PROCEDURES
The system must not be used for purposes other than those for which it
was designed.
The use of the software associated with the system and/or product, if
applicable, is subject to the terms of the license provided as part of the purchase documents.
ROSSLARE exclusive warranty and liability is limited to the warranty and
liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with the
maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively
maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury.
The text, images and graphics contained in the manual are for the purpose
of illustration and reference only.
All data contained herein is subject to change without prior notice.
In no event shall manufacturer be liable for any special, direct, indirect,
incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury).
All graphics in this manual are for reference only, some deviation between
the image(s) and the actual product may occur.
All wiring diagrams are intended for reference only, the photograph or
graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s).
.
vi AY-R6255 Installation and Operation Manual
Introduction

1. Introduction

The AY-R6255 is 13.56 MHz RFID reader and is installed when using access control systems. This is a unique product that has a variety of options to control the reader's illumination according to various settings. An example of this are the settings that enable users to set the reader to project green light when everything is normal and red in case of emergency; this is done by adjusting the inputs accordingly.
This product is compatible with any Rosslare controller that supports Wiegand 26-Bit, Wiegand 32-Bit, Wiegand 34-Bit, or Wiegand 40-Bit protocols, as well with any third-party controllers that support the same Wiegand inputs.
The panel links are used to set various conditions between events and outputs to get the required illumination from the reader.
AY-R6255 Installation and Operation Manual 7
Technical Specifications

2. Technical Specifications

Electrical Characteristics
Power Supply Type
Operating Voltage Range
Maximum Input Current
Tamper Output
Read Range* (max)
Maximum Cable Distance to Controller
RE Modulation
Output Format
Environmental Characteristics
Operating Temp. Range
Operating Humidity Range
Physical Characteristics
Height x Width x Depth
Weight
* Measured using a Rosslare proximity card or equivalent. Range also depends
on electrical environment and proximity to metal.
Linear (recommended)
12–16 VDC
Standby: 100 mA Read: 250 mA
Open collector, active low, max. sink current 16 mA
MIFARE Classic EV1®: 7 cm (2.8 in.) Felica/MIFARE Plus®/DESFire®: 3 cm
(1.2 in.) ISO1443B: 5 cm (2.0 in.) China ID: 2 cm (0.8 in.)
150 m (500 ft)
ASK @ 13.56 MHz
Wiegand 26-Bit, Wiegand 32-Bit, Wiegand 34-Bit, Wiegand 40-Bit
-31°C to 63°C (-25°F to 145°F)
0 to 95% (non-condensing)
120 x 89 x 21 mm (4.7 x 3.5 x 0.8 in.)
202 g (7.1 oz)
8 AY-R6255 Installation and Operation Manual
Mounting Instructions
To mount the reader:

3. Mounting Instructions

Installation of an RFID reader adjacent to metallic surfaces might alter the reader’s specifications. To diminish this interference, use a plastic spacer when mounting the reader.
When mounting the reader, you must remove the snap-off cover to access the screw holes.
1. Determine an appropriate mounting position for the reader.
2. Screw off the back of the unit and place it at the desired mounting position.
3. Using the template as a guide, drill two holes (hole size is indicated on mounting template) for mounting the reader to the surface (Figure 1).
Figure 1: Mounting Template
4. Drill a 10-mm (
7
/16”) hole for the cable.
5. Route the interface cable from the reader to the controller.
The proximity reader is also mountable using strong epoxy glue. After application, firmly hold the reader in place until the glue dries
AY-R6255 Installation and Operation Manual 9
Wiring Instructions
To connect the reader to the controller:

4. Wiring Instructions

The AY-R6255 is supplied with a 10-wire 45-cm (18”) pigtail, comprising a 6-conductor cable.
1. Prepare the reader cable by cutting its jacket back 4.5 cm (1¼”) and strip the wires 1.3 cm (½”).
2. Prepare the controller cable by cutting its jacket back 3.2 cm (1¼”) and stripping the wires 1.3 cm (½”).
3. Splice the reader’s pigtail wires to the corresponding controller wires and cover each connection.
Table 1: Wiring Colors
Color Wiring
Black Ground
Red Vin
Green Data 0
White Data 1
Brown G.LED
Purple Tamper
Yellow SET 0
Blue SET 1
Gray SET 2
Orange SET 3
If the tamper output is being utilized, connect the purple wire to the correct input on the controller.
10 AY-R6255 Installation and Operation Manual
Wiring Instructions
4. Trim and cover all unused conductors.
The individual wires from the reader are color-coded according the Wiegand standard.
When using a separate power supply for the reader, this supply and that of the controller, must have a com mon ground.
The reader’s cable shield wire should preferably be attached to an earth ground, or a signal ground connection at the panel, or power supply end of he cable. This configuration is best fro shielding the Reader cable from external interference
AY-R6255 Installation and Operation Manual 11
Operating Instructions

5. Operating Instructions

5.1 Lighting

Table 2 shows the settings for Set 0 through Set 3, which determine the color of the unit’s lighting.
Table 2: Operations Table
Operation Set 0 Set 1 Set 2 Set 3
Green
Green with dimming
Red
Red with dimming
Blue
Blue with dimming
Purple
Purple with dimming
Yellow
Yellow with dimming
Cyan/Aqua
Cyan/Aqua with dimming
White
White with dimming
No Illumination
7 colors circularly with dimmer
1 – Not connected; 0 – Connected to the ground
0 0 0 0
0 0 0 1
0 0 1 0
0 0 1 1
0 1 0 0
0 1 0 1
0 1 1 0
0 1 1 1
1 0 0 0
1 0 0 1
1 0 1 0
1 0 1 1
1 1 0 0
1 1 0 1
1 1 1 0
1 1 1 1
12 AY-R6255 Installation and Operation Manual
Operating Instructions

5.2 DIP Switch Settings for Output and Input Formats

Setting the DIP Switches of Pins 1 and 2 determine the output format of the reader (Table 3), while Pins 3 and 4 determine the card format that is read (Table 4).
Pins 5 through 8 are for future use.
Table 3: Output Format
Pin 1 Pin 2 Output
0 0 Wiegand 26-Bit
0 1 Wiegand 32-Bit
1 0 Wiegand 34-Bit
1 1 Wiegand 40-Bit
Table 4: Read Format
Pin 3 Pin 4 Read
0 0 ISO14443A
0 1 ISO14444B
1 0 ISO15693.Felica.Topaz
1 1 China ID/ ISO14443A
AY-R6255 Installation and Operation Manual 13
Testing the Reader
To test the reader:

6. Testing the Reader

Once the reader has been wired to a power supply and the controller, it should be tested.
1. Power up the reader. The beeper activates 3 times after which the
LED lights up green (according to Set 0, Set 1, Set 2, and Set 3 setup). This indicates that the reader is working properly.
The default is that the reader switches colors circularly. The color can be set according to the input wires.
2. Present the appropriate type of proximity card to the reader. The
LED turns green (if set to default) and a short beep is emitted, indicating that the card was read properly by to proximity reader.
14 AY-R6255 Installation and Operation Manual
Limited Warranty

A. Limited Warranty

The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at
www.rosslaresecurity.com
Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.
.
AY-R6255 Installation and Operation Manual 15
Caution:
This device complies with Part 15 of the FCC rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or change to this equipment. Such modifications or change could void the user’s authority to operate the equipment. This radio transmitter (identify the device by certification number or model number if Category II) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement.
To maintain compliance with FCC’s RF exposure guidelines, this equipment should be
installed and operated with a minimum distance of 20cm between the radiator and your body.
0706-0960607+00
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd. Kowloon Ba y, Hong Kong Tel: +852-2795-5630 Fax: +852-2795-1508 support.apac@rosslaresecurity.com
United States and Canada
Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd. Rosh HaAyin, Israel Tel: +972-3-938-6838 Fax: +972-3-938-6830 support.eu@rosslaresecurity.com
AY-R6255
Latin America
Rosslare Latin America Buenos Aires, Argentina Tel: +54-11-4001-3104 support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86-755-8610 6842 Fax: +86-755-8610 6101 support.cn@rosslaresecurity.com
India
Rosslare Electronics India Pvt Ltd. Tel/Fax: +91-20-40147830 Mobile: +91 -9975768824 sales.in@rosslaresecurity.com
Loading...