1. Introduction
The CSN SELECT AY-x6255 is a family of multi-credential technology contactless smart card readers for use in access control system solutions. CSN SELECT readers have the capability to read the Card Serial Number (CSN) from many smart card RFID Standards implementations. The following list shows the credential technologies for which we have confirmed compatibility:
ISO14443A – MIFARE® Ultralight® Nano / EV1/ C, MIFARE
Classic® / Classic EV1, MIFARE Plus® S / SE / X / EV1, MIFARE DESFire® EV1 / EV2, NFC N–TAG / Card Emulation
ISO14443B – China National ID ISO15693 – HID® iClass®, PicoPass, iCode, LEGIC ISO18092 – SONY® FeliCa® (Hong Kong Octopus)
This list is continuously updated. For the latest compatibility list, contact your sales representative.
The standard readers output the Wiegand CSN data in 26-bit format. Other Wiegand formats are available upon request.
1.1 Installation Kit
The installation kit consists of the following items to be used during the installation procedure:
One self-adhesive mounting label template Two pan head mounting screws and screw anchors
One pin Torx key tool One pin Torx security screw
AY-K6255 AY-L6255 AY-H6255 AY-M6255
2. Technical Specifications
2.1 Electrical Characteristics
Power Supply Type
Regulated
Operating Voltage Range
8 to 16 VDC
Current @ 12 V
AY-K/L6255: Standby: 55 mA, max: 80 mA AY-H/M6255: Standby: 75 mA, max: 110 mA
Read Range*
AY-K6255: 5 cm (2.0 in.) AY-L6255: 7 cm (2.9 in.) AY-H/M6255: 9 cm (3.5 in.)
Green LED Control**
Dry Contact, N.O.
Red LED Control**
Dry Contact, N.O.
Buzzer Control**
Dry Contact, N.O.
Tamper Output**
Open collector, active low, max. sink current 16 mA
Maximum Cable Distance to Controller
Wiegand: 150 m (500 ft) with 18-AWG cable OSDP (RS-485): 1,200 m (4,000 ft) with 2x2 18-
AWG twisted shielded cable
* Measured using a Rosslare MIFARE Classic EV1 (ISO Card). Read range with
other credential technologies may vary. Range also depends on electrical environment and proximity to metal.
** Control Lines are factory programmable and can be custom configured upon
request.
2.2 Environmental Characteristics
Operating Temp. Range
-35°C to 66°C (-31°F to 150°F)
Operating Humidity Range
0 to 95% (non-condensing)
Outdoor Usage
Weather-resistant, UV-resistant, meets IP65, epoxy-potted, suitable for indoor and outdoor use
2.3 Physical Characteristics
Dimensions (H x W x D)
AY-K6255: 80.5 x 40.5 x 14.7 mm (3.2 x 1.6 x 0.6 in.)
AY-L6255: 145.0 x 43.0 x 22.3 mm (5.7 x 1.7 x 0.9 in.)
AY-H6255: 110.7 x 75.0 x 17.0 mm (4.4 x 3.0 x 0.7 in.)
AY-M6255: 89.5 x 88.5 x 16.9 mm (3.5 x 3.5 x 0.7 in.)
Weight
AY-K6255: 73 g (2.6 oz)
AY-L6255: 130 g (4.6 oz)
AY-H6255: 177 g (6.2 oz)
AY-M6255: 167 g (5.9 oz)
3. Wiring Instructions
The units are supplied with a 10-conductor 18” (46-cm) pigtail.
To connect the reader to the controller:
1. Prepare the reader cable by cutting its jacket back about 3 cm (1¼”) and strip the insulation from the wires about 1.3 cm (½").
2. Prepare the controller cable by cutting its jacket back about 3 cm (1¼") and strip the insulation from the wires about 1.3 cm (½").
3. Splice the reader’s pigtail wires to the corresponding controller wires (see Table 1) and cover each joint with insulating tape.
4. If the tamper output is being utilized, connect the purple wire to the correct input on the controller.
5. Trim and cover all unused conductors.
The individual wires from the reader are color coded according the Wiegand standard.
When using a separate power supply for the reader, this supply and that of the controller must have a c ommon ground.
The reader’s cable shield wire should be preferably attached to an earth ground, or a signal ground connection at the panel, or power supply end of the cable.
Table 1: Wiring
Wire Color Function
Red Power
Black Ground
Green Data 0 / Data
White Data 1 / Clock
Orange Green LED control
Brown Red LED control
Purple Tamper Output
Yellow Buzzer control
Blue RS-485 - A / OSDP*
Gray RS-485 - B / OSDP*
* RS-485 is used for firmware update. OSDP function available only for the AY-
H6255 and AY-M6255 models.
Page 2
2
4. OSDP Operation
The AY-K6255 and AY-L6255 models do not currently support OSDP function.
In OSDP mode, all control lines (Inputs/Outputs) are disabled.
In OSDP mode, if a connection is not established or lost with the
controller, the LED flashes orange continuously.
CSN SELECT readers that support OSDP operation are compatible with all reader-related OSDP commands. The reader address is set using DIP switches on the back of the reader. Release the screw on the back of the reader to remove the door to access the DIP switches.
Figure 1 shows the DIP switch settings, which are described below.
Figure 1: DIP Switch Settings
DIP Switch 1
This switch is used to select the reader output (Wiegand or OSDP):
Off = Wiegand
On = OSDP
DIP Switch 2
This switch is reserved for future use.
DIP Switch 3
This switch is reserved for future use.
DIP Switches 4 to 8
These switches set the address of the reader for OSDP protocol.
DIP Switch 4 is MSB and DIP Switch 8 is LSB. The address is the DIP switch state +1.
Examples:
All the DIP switches in Off position, address = 1 All the DIP switches in On position, address = 32
Declaration of Conformity
AY-M/H6255: FCC ID = GCD-AYCX6X55
AY-K/L6255: FCC ID = GCD-AYX6255
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com. Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.
Contact Information
United States and Canada
Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd. Rosh HaAyin, Israel Tel: +972-3-938-6838 Fax: +972-3-938-6830 support.eu@rosslaresecurity.com
Latin America
Rosslare Latin America Buenos Aires, Argentina Tel: +54-11-4001-3104 support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86-755-8610-6842 Fax: +86-755-8610-6101 support.cn@rosslaresecurity.com
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852-2795-5630 Fax: +852-2795-1508 support.apac@rosslaresecurity.com
India
Rosslare Electronics India Pvt Ltd. Tel/Fax: +91-20-40147830 Mobile: +91-9975768824 sales.in@rosslaresecurity.com
www.rosslaresecurity.com
0706-0960618+02
Loading...