1. Introduction
The CSN SMART™ AY-H6255BT is an innovative reader that lets cardholders use smartphone apps as credentials in access control systems by BLE ID and NFC ID compatible apps. The unit features three technologies: a built-in CSN smart card (13.56 MHz) reader, an NFC ID reader, and a Bluetooth BLE ID reader mode that supports BLE ID transmitted by both Android and iOS smartphone apps.
The following list shows the credential technologies for which we have confirmed compatibility:
ISO14443A – MIFARE® Ultralight® Nano / EV1/ C, MIFARE
Classic® / Classic EV1, MIFARE Plus® S / SE / X / EV1, MIFARE DESFire® EV1 / EV2, N-TAG NFC / Card Emulation
ISO15693 – HID® iClass®, PicoPass, iCode, LEGIC
ISO18092 – SONY® FeliCa® (Hong Kong Octopus) Rosslare’s CS-ECA NFC app (HCE) for Android smartphones
Scan the QR code to download Rosslare’s NFC app.
Android app and BLE ID for Android and iPhone
This list is continuously updated. For the latest compatibility list, contact your sales representative
The standard reader outputs the Wiegand CSN data in Wiegand 26-Bit format. Other Wiegand formats are selectable using the
CS-CCT
Configuration Card Tool for the DR-6255
application.
1.1 Installation Kit
The installation kit consists of the following items to be used during the installation procedure:
1 self-adhesive mounting label template 2 mounting screws and 2 screw anchors
1 Torx key tool 1 Torx security screw
Figure 1: AY-H6255BT
2. Technical Specifications
2.1 Electrical Characteristics
Power Supply Type
Regulated
Operating Voltage Range
8 to 16 VDC
Current @ 12 V
Standby: 110 mA, max: 185 mA
Bluetooth BLE Read Range
From 1 m to 10 m (3.2 to 32.5 ft) (line of sight)
RFID and NFC Read Range*
5 cm to 10 m (2.0 to 3.9 in.)
LED/Buzzer Controls
Dry Contact, N.O.
Tamper Output
Open collector, active low, max. sink current 16 mA
Maximum Cable Distance to Controller
Wiegand: 150 m (500 ft) with 18-AWG cable OSDP (RS-485): 1,200 m (4,000 ft) with 2x2
18-AWG twisted shielded cable
* Measured using a Rosslare MIFARE Classic EV1 (ISO card). Read range with
other credential technologies may vary. Range also depends on electrical environment and proximity to metal.
2.2 Environmental Characteristics
Operating Temp. Range
-35°C to 66°C (-31°F to 150°F)
Operating Humidity Range
0 to 95% (non-condensing)
Outdoor Usage
Weather-resistant, UV-resistant, meets IP65, epoxy-potted, suitable for indoor and outdoor use
2.3 Physical Characteristics
Dimensions (H x W x D)
110.7 x 75.0 x 17.0 mm (4.4 x 3.0 x 0.7 in.)
Weight
177 g (6.2 oz)
3. Wiring
The units are supplied with a 10-conductor 5-m (16-ft) pigtail with exposed wires coated with solder.
To connect the reader to the controller:
1. Select the appropriate connections according to Table 1.
2. Prepare the controller cable by cutting its jacket back about 3 cm (1¼") and strip the insulation from the wires about 1.3 cm (½").
3. Splice the reader’s pigtail wires to the corresponding controller wires and cover each joint with insulating tape.
4. If the tamper output is being utilized, connect the purple wire to the correct input on the controller.
5. Trim and insulate the ends of all unused conductors individually. Do not short any unused wires together.
The individual wires from the reader are color coded according the Wiegand standard.
When using a separate power supply for the reader, this supply and that of the controller must have a common ground.
The reader’s cable shield wire should be preferably attached to an earth ground, or a signal ground connection at the panel, or power supply end of the cable.
Table 1: Wiring
Wire Color Function
Red Power
Black Ground
Green Data 0 / Data
White Data 1 / Clock
Orange Green LED Control*
Brown Red LED Control*
Purple Tamper Output
Yellow Buzzer Control*
Blue RS-485 – A / OSDP**
Gray RS-485 – B / OSDP**
* These wires have programmable functions that may be adjusted by presenting
a configuration card within 10 seconds upon powering on the unit. See the
CS-CCT Configuration Card Tool for the DR-6255 Software Manual
for how
you can create a configuration card.
** RS-485 is used for firmware update.
Page 2
2
4. Bluetooth BLE ID and NFC ID Operation
4.1 NFC ID
The NFC ID read function of the AY-H6255BT can read both active and passive NFC credentials. Rosslare features smartphone applications that generate Unique NFC ID for each smartphone.
NFC ID is a short-range contactless technology that works at a range of 3 to 10 cm 2.0 to 3.9 in from the readers depending on the smartphone or passive tag.
The reader scans for NFC ID and transmits the ID number to the host controller via OSDP or Wiegand protocols.
To find out more information on Rosslare’s NFC ID credential app for Android, talk to your nearest authorized reseller.
4.2 BLE ID
The BLE ID can read credentials via Bluetooth using Rosslare’s mobile Bluetooth app
The service accepts incoming connection requests and transfers the credential by Wiegand or OSDP connection to the host. This feature includes MAC address and reader name advertising.
BLE ID credentials have a line-of-sight range of up to 10 m (33 ft) from the reader depending on the type and brand of smartphone or BLE device.
For more information about BLE functionality, please see the manual of the credential. For additional information about apps, please refer your enquiries to an authorized Rosslare distributor.
5. Configuration Card Programming
The
CS-CCT Configuration Card Tool for the DR-6255
application is used to create a configuration card, which in turn can be used to configure the AY-H6255BT reader.
The application allows you to configure RFID output settings, keypad settings (for AYC models), input behavior for the LED, buzzer, and hold controls, and the behavior for the LED and buzzer when a credential is presented or when in Standby mode.
For more information, please see the
CS-CCT Configuration Card Tool
for the DR-6255 Software Manual
.
6. OSDP Operation
In OSDP mode, all control lines (Inputs/Outputs) are disabled.
In OSDP mode, if a connection is not established or lost with the
controller, the right LED flashes yellow continuously.
CSN SMART readers that support OSDP operation are compatible with all reader-related OSDP commands. The reader address is set using DIP switches on the back of the reader. Release the screw on the back of the reader to remove the door to access the DIP switches.
Figure 2 shows the DIP switch settings, which are described below.
Figure 2: DIP Switch Settings
DIP Switch 1
This switch is used to select the reader output (Wiegand or OSDP):
Off = Wiegand On = OSDP
DIP Switch 2
This switch is reserved for future use.
DIP Switch 3
This switch is reserved for future use.
DIP Switches 4 to 8
These switches set the address of the reader for OSDP protocol. DIP Switch 4 is MSB and DIP Switch 8 is LSB. The address is the DIP
switch state +1.
Examples:
All the DIP switches in Off position, address = 1
All the DIP switches in On position, address = 32
7. LEDs Operation
7.1 Standby Mode
Once the reader powers on (or resets), the reader enters Standby Mode. The left LED is blue and the right LED is red.
7.2 Card Read
When the reader reads a contactless card or NFC ID read, the right LED flashes green and the unit beeps once. The data is transferred to the host via Wiegand.
7.3 NFC ID Read
When the reader reads an NFC ID, the right LED flashes green and the unit beeps twice. The ID is transferred to the host via Wiegand.
red blue
green
blue
green
blue
Page 3
3
Declaration of Conformity
FCC ID: GCD-AYH6X55BT This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
This device may not cause harmful interference. This device must accept any interference received, including
interference that may cause undesired operation.
WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Radio Equipment Directive (RED)
Rosslare hereby declares that the AY-H6255BT is in compliance with essential requirements and other relevant provisions of Directive 2014/53/EU.
Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com. Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.
International Standards Approvals
Description Latest Standard Latest EU Directive
CE-EMC
EN 61000-6-3:2007+A1:2011+AC:2012 EN 50130-4:2011+A1:2014 EN 61000-3-2:2014 EN 61000-3-3:2013 AOC
EMCD 2014/30/EU
CE-LVD
EN60950-1 : 2006+A11 : 2009+A1 : 2010+A12 : 2011+A2 : 2013
RED 2014/53/EU
CE-RED
N 300 330 V2.1.1 EN 301 489-1 V2.2.0 EN 301 489-3 V2.1.1 EN 301 489-17 V3.1.1/EN 300 328 V 2.1.1 EN62479: 2010 NB
RED 2014/53/EU
FCC
FCC Part 15B FCC Part 15.225 and 15.247 FCC ID
Contact Information
United States and Canada
Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd. 22 Ha'Melacha St., P.O.B. 11407 Rosh HaAyin, Israel Tel: +972-3-938-6838 Fax: +972-3-938-6830 support.eu@rosslaresecurity.com
Latin America
Rosslare Latin America Buenos Aires, Argentina Tel: +54-11-4001-3104 support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86-755-8610-6842 Fax: +86-755-8610-6101 support.cn@rosslaresecurity.com
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852-2795-5630 Fax: +852-2795-1508 support.apac@rosslaresecurity.com
India
Rosslare Electronics India Pvt Ltd. Tel/Fax: +91-20-40147830 Mobile: +91-9975768824 sales.in@rosslaresecurity.com
CERT
ISO 9001 ISO 14001
BLE 4.1
Loading...