Rosslare AYG6XX0, AYH6XX0 User Manual

AY-G/H6xx0
Open to Secure (O2S) Readers
Installation and User Manual
Models:
AY-G6270/G6280 AY-H6270/H6280
AY-H6270/H6280 AY-G6270/G6280 AY-G6370/G63 80 AY-H6370/H6380
AY-G6370/G6380 AY-H6370/H6380
Copyright © 2014 by Rosslare. All rights reserved.
This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
Table of Contents
Table of Contents
1. Introduction ................................................................ 8
1.1 Key Features ........................................................................... 8
1.2 Box Content ........................................................................... 9
2. Technical Specifications ............................................ 10
3. Mounting ................................................................... 12
4. Wiring Instructions ................................................... 13
5. Reader Operation ...................................................... 15
6. Proximity Operation ................................................. 16
6.1 Supported Credential Technologies ........................................ 16
6.2 Wiegand Output ................................................................... 16
7. Keypad Operation Instructions ................................ 17
7.1 Programming Menu .............................................................. 17
7.2 Entering Programming Mode ................................................. 18
7.3 Exiting Programming Mode ................................................... 18
7.4 Selecting Keypad Transmission Format ................................... 18
7.5 Keypad Transmission Format Option Number ......................... 19
7.5.1 Option 1: Single Key, Wiegand 6-Bit (Rosslare Format) ................. 20
7.5.2 Option 2: Single Key, Wiegand 6-Bit Nibble and Parities ............... 20
7.5.3 Option 3: Single Key, Wiegand 8-Bit Nibbles Complemented ....... 20
7.5.4 Option 4: 4 Keys Binary + Facility Code, Wiegand 26-Bit .............. 21
7.5.5 Option 5: 1 to 5 Keys + Facility Code, Wiegand 26-Bit ................. 21
7.5.6 Option 6: 6 Keys BCD and Parity Bits, Wiegand 26-Bit .................. 22
7.5.7 Option 8: 1 to 8 Keys BCD, Clock & Data ..................................... 23
7.5.8 Option 9: Single Key, Wiegand 4-Bit ............................................. 24
AY-G/H6xx0 Installation and User Manual iii
Table of Contents
7.6 Changing the Programming Code .......................................... 24
7.7 Changing the Facility Code .................................................... 24
7.8 Setting the Backlight Behavior ............................................... 25
7.9 Return to Factory Default Settings .......................................... 26
7.10 Replacing a lost Programming Code ....................................... 26
8. OSDP Operation ......................................................... 27
A. Wiegand Output Formats ......................................... 28
A.1 Rules for Wiegand 26-Bit (26A) .............................................. 29
A.2 Wiegand 38-Bit (38A) ............................................................ 31
B. Limited Warranty ...................................................... 33
iv AY-G/H6xx0 Installation and User Manual
List of Figures
List of Figures
Figure 1: Mounting.......................................................................................... 12
AY-G/H6xx0 Installation and User Manual v
List of Tables
List of Tables
Table 1: Wiring ................................................................................................ 13
Table 2: Reader Programming Menu ............................................................... 17
Table 3: Keypad Transmission Format .............................................................. 19
Table 4: Bit Description Table .......................................................................... 28
vi AY-G/H6xx0 Installation and User Manual
Introduction
Notice and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein.
B
EFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND THE
USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING PROCEDURES
The system must not be used for purposes other than those for which it
was designed.
The use of the software associated with the system and/or product, if
applicable, is subject to the terms of the license provided as part of the purchase documents.
ROSSLARE exclusive warranty and liability is limited to the warranty and
liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with the
maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively
maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury.
The text, images and graphics contained in the manual are for the purpose
of illustration and reference only.
All data contained herein subject to change without prior notice.
In no event shall manufacturer be liable for any special, direct, indirect,
incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury).
All graphics in this manual are for reference only, some deviation between
the image(s) and the actual product may occur.
All wiring diagrams are intended for reference only, the photograph or
graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s).
.
AY-G/H6xx0 Installation and User Manual vii
Introduction

1. Introduction

The Open to Secure (O2S) family of readers are multi-format contactless smart card readers for use in access control system solutions.
The AY-x6x70 readers support reading O2S ID data and the CSN from MIFARE Plus
The AY-x6x80 readers support reading O2S ID Data and the CSN from MIFARE
O2S ID data is stored in the secure memory of the MIFARE credential. O2S ID data is AES 128-bit encrypted during transmission to the reader for MIFARE Plus and DESFire EV1 credentials.

1.1 Key Features

Contactless smart card reader (13.56 MHz) Meets ISO14443 Type A Standard
AES 128-bit encryption during transmission (MIFARE Plus and
Reads O2S ID data from O2S credentials
Reads CSN of non-O2S credentials Output formats:
RGB multi-color light indicator
Blue backlit tact switch keypad Fully-potted construction for indoor and outdoor use
Optical back tamper sensor with OC output Two LED control inputs Buzzer control input
Hold feature (not in standard configuration)
®
and MIFARE® Classic credentials.
®
DESFire® EV1 and MIFARE Classic credentials.
MIFARE DESFire EV1)
Wiegand (outputs per format on the card) OSDP via RS-485 (selected models)
8 AY-G/H6xx0 Installation and User Manual
Introduction
Pigtail or terminal block connectivity Comes with mounting template for easier installation
Comes with an installation kit that includes a security Trox screw
and a security Torx screw tool.

1.2 Box Content

Before beginning, verify that all of the following is in the box. If anything is missing, please report the discrepancy to your nearest Rosslare office.
One O2S reader
Installation kit – Includes two wall plugs, two mounting screws,
security Torx screw, and security Torx screw tool
Installation and operating instructions
AY-G/H6xx0 Installation and User Manual 9
Technical Specifications

2. Technical Specifications

Electrical
AY-G H6xx0
Characteristics
Power Supply Type
Operating Voltage Range
Current @ 12 V
Read Range for G Models*
Read Range for H Models*
LED Control Input 1**
LED Control Input 2**
Auxiliary Input**
Auxiliary Output**
Maximum Cable Distance to Controller
Linear type (recommended)
6 to 16 VDC
Standby: 85 mA Maximum: 110 mA
MIFARE Classic: 40 to 45 mm (1.5 to 1.8 in.) MIFARE Plus: 25 mm (1 in.) MIFARE DESFire EV1: 25 mm (1 in.)
MIFARE Classic: 40 to 45 mm (1.5 to 1.8 in.) MIFARE Plus: 30 mm (1.2 in.) MIFARE DESFire EV1: 30 mm (1.2 in.)
Green LED control, TTL
Red LED control, TTL
Buzzer control, TTL
Tamper output (open collector, active low, max. sink current 30 mA)
Wiegand: 150 m (500 ft) with 18-AWG cable OSDP (RS-485): 1200 m (4,000 ft) with 2x2
18-AWG twisted shielded cable
Environmental Characteristics
Operating Temp. Range
Operating Humidity Range
Outdoor Usage
-31°C to 63°C (-24°F to 145°F)
0 to 95% (non-condensing)
Weather-resistant, meets IP65, epoxy-potted, suitable for indoor and outdoor use
* Measured using Rosslare O2S ISO cards. Range also depends on
electrical environment and proximity to metal.
** Standard configuration. Custom configurations are available.
10 AY-G/H6xx0 Installation and User Manual
Technical Specifications
Physical Characteristics
Dimensions of Pigtail Models
(H x W x D)
Dimensions of Terminal Block and OSDP Models
(H x W x D)
Weight
AY-G6xx0: 145.3 x 42.0 x 23.0 mm (5.7 x 1.7 x 0.9 in.)
AY-H6xx0: 120.0 x 80.0 x 23.0 mm (4.7 x 3.2 x 0.9 in.)
AY-G6xx0: 145.3 x 42.0 x 31.0 mm (5.7 x 1.7 x 1.2 in.)
AY-H6xx0: 120.0 x 80.0 x 31.0 mm (4.7 x 3.2 x 1.2 in.)
AY-G6xx0: 155 g (5.5 oz)
AY-H6xx0: 217.0 g (7.7 oz)
AY-G/H6xx0 Installation and User Manual 11
Loading...
+ 23 hidden pages