Rosslare AY-E20 Instruction Manual

Page 1
AY-E20
Ultra-slim Vandal Resistant
Multi-format Proximity Reader
Instruction Manual
March 2008
Page 2
Page 3
Table of Contents
AY-E20 Instruction Manual Page ii
Table of Contents
1. General Information...........................................................3
1.1 Introduction.............................................................................. 3
1.2 Box Content.............................................................................3
1.3 Ancillary Equipment................................................................ 3
2. Technical Specifications ...................................................4
2.1 Key Features............................................................................. 5
3. Installation...........................................................................6
3.1 Mounting the AY-E20 .............................................................. 6
4. Wiring Instructions ..............................................................8
4.1 Wiring the AY-E20..................................................................... 8
5. Operational Instructions ....................................................9
5.1 Testing the AY-E20 and Card Reading................................. 9
5.2 Card Transmission Format Selection ..................................... 9
5.3 Tri-Color LED Color Control................................................... 10
5.4 Buzzer Control........................................................................10
5.5 Card Read/Hold Control...................................................... 10
5.6 Tamper Output...................................................................... 10
Appendix A. Limited Warranty ...........................................11
Appendix B. Technical Support .........................................13
Page 4
General Information
AY-E20 Instruction Manual Page 3
1. General Information
1.1 Introduction
The AY-E20 is an ultra-slim, multi-format RFID proximity card reader that is installed for use with access control systems. The unit is vandal resistant and water resistant, suitable for indoor or outdoor mounting.
This instruction manual contains information regarding the features, mounting, wiring, operating instructions and warranty details for the AY-E20 reader.
1.2 Box Content
Before beginning verify that all of the following is in the box. If anything is missing, please report the discrepancy to your nearest Rosslare office.
One AY-E20 unit
Installation kit and mounting template
Installation and operating instruction
1.3 Ancillary Equipment
The following equipment is required to complete your installation:
Compatible host controller (not supplied) - UL listed access control unit, i.e., model AC-215U or AC-225U
Rosslare accessories can be found on www.rosslaresecurity.com
.
Page 5
Technical Specifications
AY-E20 Instruction Man u al Page 4
2. Technical Specifications
Specifications AY-E20
Electrical Characteristics Power supply type Linear type – recommended Operating voltage
range
5 - 16VDC
Input current standby 40mA@12VDC Max Input current 100mA@16VDC Tamper output Open collector, active low , 16mA max
sink current
Cable distance to host controller
Up to 500ft (150 meters) using an 18AWG cable
Proximity card read range*
1.37inch (3.5cm )
Proximity card modulation
ASK at 125 KHz
Proximity card compatibility
EM cards
Card Transmit format 26-bit Wiegand, Clock & Data or Serial
RS232
LED indicators One tri-colored LED Environmental Characteristics
Operating temp. range -25 to 145° F (-31 to 63° C) Operating humidity 0 – 95% (non-condensing) Outdoor usage Weather-resistant, meets IP-68, epoxy
Page 6
Technical Specifications
AY-E20 Instruction Manual Page 5
Specifications AY-E20
potted, suitable for outdoor use
Mechanical Size
(Height x Width x Depth)
155 x 45 x 8 mm
6.1x1.77x0.314 inch
Weight 135gr(0.297lb)
*Measured using Rosslare proximity card (AT-14) or equivalent. Range also depends on electr ical environment and proximity to metal.
2.1 Key Features
The key features for the AY-E20 are:
Ultra-Slim Flush-mount design on flat surface
Fully potted, waterproof construction for outdoor use
Built-In 125 KHz ASK EM proximity card reader
Selectable Card Transmission Formats: 26-Bit Wiegand,
Clock & Data, or Serial RS-232 output
Optical back tamper sensor
Bi-Color LED control
Buzzer control
Card read/hold control
Mounting template for easier installation
Installation kit
Limited lifetime warranty
Page 7
Installation
AY-E20 Instruction Man u al Page 6
3. Installation
3.1 Mounting the AY-E20
Before starting, select the location to mount the AY-E20. This location should be at shoulder height. To mount the AY-E20, perform the following:
1) For wall mounting, use the included mounting template as a guide for drilling holes and mounting screws (See figure 1).
2) Drill a hole for the cable. I f mounting on metal, place a grommet or electrical tape around the edge of the hole.
3) Route the interface cable from the AY-E20 to the Controller.
Figure 1 Drilling & Mounting Template
Page 8
Installation
AY-E20 Instruction Manual Page 7
For US Gang Box mounting, no drilling is necessary. Simply screw the AY-E20 to its mounting location or US gang box.
Note:
A linear type power supply is recommended
Card readers are to be used with control panels whose power
supply is UL Listed Class 2 or equivalent
Page 9
Wiring Instructions
AY-E20 Instruction Man u al Page 8
4. Wiring Instructions
4.1 Wiring the AY-E20
The unit is supplied with a 39.4 inch pigtail, having a 10-conductor cable. To connect the unit to the controller, perform the following:
1) Prepare the unit's cable by cutting the cable jacket back 1¼ inches and strip the wire ½ inch.
2) Prepare the controller cable by cutting the cable jacket back 1¼ inches and strip the wire ½ inch.
3) Splice the unit’s pigtail wires to the corresponding controller wires and cover each connection. Refer to the wire color table below.
Wire
Color
Weigand
Output Mode
Clock & Data Output Mode
Serial (RS232)
Output Mode
Red +DC +DC +DC
Black Ground Ground Ground
Green Data 0 Data Tx (RS-232)
White Data 1 Clock -
Orange Green LED Green LED Green LED
Brown Red LED Red LED Red LED
Yellow Buzzer Buzzer Buzzer
Blue Hold Hold Hold
Purple Tamper Tamper Tamper
Grey Open Input Connect to GND
Connect to +DC
4) If the tamper output is used, connect the purple wire to the correct input on the controller.
5) Trim and cover all unused conductors.
Page 10
Operationa l Instructions
AY-E20 Instruction Manual Page 9
5. Operational Instructions
The AY-E20, once connected to standard access controller, functions as a reader. This is indicated by one beep immediately after power-on reset.
The following pages explain the operational instructions of the AY­E20.
5.1 Testing the AY-E20 and Card Reading
The AY-E20 should be tested after wiring it to the Contr o ller. To test the AY-E20, perform the following:
1) Power-up the AY-E20. The LED and Beeper will activate one time. This indicates that the AY-E20 is working properly.
2) Present the appropriate type of proximity card to the AY-E20. The LED will momentarily flash green and a short beep will be emitted. This indicates that the card was read properly by the AY-E20.
3) Once the card’s data has been processed by the Controller, the Controller can then switch the LED on the AY-E20 to green. Refer to the relevant Contro ller instruction manual for more information on controlling LED behavior via the Controller.
5.2 Card Transmission Format Selection
To select the appropriate Card Transmission Format, perform one of the following:
26-Bit Wiegand - the grey wire should be an open circuit
Clock & Data - the grey wire should be held to ground
Serial RS-232 - the grey wire should be held to +DC (VIN).
Page 11
Operationa l Instructions
AY-E20 Instruction Manual Page 10
5.3 Tri-Color LED Color Control
The Tri-Color LED color can be controlled using the orange and brown wires. To control the Tri-Color LED color, perform one of the following:
If the orange wire is held to ground the LED will light green
If the brown wire is held to ground the LED will light red
If both the brown and orange wires are held to ground the
LED will light amber
If the orange and brown wires are not used (open) the LED will remain red continuously and when successfully reading a card the LED will flash green momentarily
5.4 Buzzer Control
The Buzzer can be controlled using the yellow wire. To control the Buzzer, perform one of the following:
If the yellow wire is held to ground the buzzer will sound
If the yellow wire is not used (open) the buzzer will beep
only when a card is read successfully
5.5 Card Read/Hold Control
The reading of cards can be disabled using the blue wire. To control the reading of cards, perform one of the following:
If the blue wire is held to ground the reader will ignore all cards placed in its field
If the blue wire is not used (open) the reader will read all compatible cards normally
5.6 Tamper Output
The AY-E20 has an optical tamper s ensor; when the sensor detects light the tamper output is held open collector; when the sensor does not detect light the tamper output is held to ground.
Page 12
Limited Warranty
AY-E20 Instruction Manual Page 11
Appendix A. Limited Warranty
ROSSLARE ENTERPRISES LIMITED S (Rosslare) FIVE YEARS LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's FIVE YEARS LIMITED WARRANTY is subject to the following conditions:
Warranty
Warranty of Rosslare's products extends to the original purchaser (Customer) of the Rosslare product and is not transferable.
Products Covered By This Warranty and Duration
ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARIES (ROSSLARE) warrants that the AY-E20, Ultra Slim Metal Reader as listed above, to be free from defects in materials and assembly in the course of normal use and service. The warranty period commences with the date of shipment to the original purchaser and extends for a period of 5 years (60 Months).
Warranty Remedy Coverage
In the event of a breach of warranty, ROSSLARE will cre dit Customer with the price of the Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty. Unless otherwise requested by ROSSLARE ENTERPRISES LTD. AND / OR SUBSIDIARIES representative, return of the failed product(s) is not immediately required. If ROSSLARE has not contacted the Customer within a sixty (60) day holding period following the delivery of the warranty claim, Customer will not be required to return the failed product(s). All retur ned Prod uct (s) , as may be re qu ested at ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARY’S sole discretion, shall become the property of ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARIES. To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to obtain an RMA number after which, the product must be returned to the Manufacturer freight prepaid and insured In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day holding period and no defect is found, a minimum US$ 50.00 or equ i valent charge will be applied to each Product for labor required in the evaluation. Rosslare will repair or replac e, at its discretion, any product that under normal cond itions of use and service proves to be de fec tive in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by Rosslare or a Rosslare authorized service center.
Page 13
Limited Warranty
AY-E20 Instruction Manual Page 12
Exclusions and Limitations
ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated. This warranty sha ll not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product that is used with any ancillary equipment, which is not furnished by ROSSLARE. This warranty does not cover expenses incurred in the transportation, freight cost to the repair center, removal or reinstallation of the product, whether or not proven defective. Specifically excluded from this warranty are any failures resulting from Customer's improper testing, operation, installation, or damage resulting from use of the Product in other than its normal and customary man ne r, or any mai ntenance, modification, alte rati o n, or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defects or damage due to lightning or other electrical discharge. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument, or any modification or abuse of, or tampering with, the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim. ROSSLARE does not warrant the installation, maintenance, or service of the Product. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall Rosslare be liable for incidental or consequential damages.
Limited Warranty Terms
THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE ENTERPRISES LTD. AND IT
S SUBSIDIARY'S WARRANTY
THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON, WHETHER OR NOT PURPORTING TO REPRESENT OR ACT ON BEHALF OF ROSSLARE
.
THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES. ALL OTHER WARRANTIES EXPRESSED OR IMPLIED
, INCLUDING WITHOUT LIMITATION, IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
, ARE
SPECIFICALLY EXCLUDED
.
IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT
, OR FOR ANY OT HER INCIDENTAL,
CONSEQUENTIAL OR SPECIAL DAMAGES
, INCLUDING BUT NOT LIMITED TO LOSS OF
USE
, LOSS OF TIME, COMMERCIAL LOSS, INCONVENIENCE, AND LOSS OF PROFITS,
ARISING OUT OF THE INSTALLATION
, USE, OR INABILITY TO USE SUCH PRODUCT, TO
THE FULLEST EXTENT THAT ANY SUCH LOSS OR DAMAGE MAY BE DISCLAIMED BY LAW
.
THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE PROVISIONS OF THIS LIMITED WARRANTY
.
Page 14
Technical Support
AY-E20 Instruction Manual Page 13
Appendix B. Technical Support
Asia Pacific, Middle East, Africa
Rosslare Security Products Headquarters 905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road, Kowloon Bay Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 E-mail: support.apac@rosslaresecurity.com
United States and Canada
1600 Hart Court, Suite 103 Southlake, TX, USA 76092 Toll Free:+1-866-632-1101 Local:+1-817-305-0006 Fax: +1-817-305-0069 E-mail: support.na@rosslaresecurity.com
Europe
Global Technical Support & Training Center HaMelecha 22 Rosh HaAyin, Israel 48091 Tel: +972 3 938-6838 Fax: +972 3 938-6830 E-mail: support.eu@rosslaresecurity.com
South America
Pringles 868, 1640 Martinez Buenos Aires Argentina Tel: +54 11 4798-0095 Fax: +54 11 4798-2228 E-mail: support.la@rosslaresecurity.com
Web Site: www.rosslaresecurity.com
Page 15
Page 16
0706-0960225+01
www.rosslaresecurity.com
Loading...