This manual and the information contained herein are proprietary to ROSSLARE
ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’
(hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to
use the information.
No part of this manual may be re-produced or transmitted in any form or by any
means, electronic or mechanical, for any purpose, without the express written
permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or
other intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN
THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS
AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND
TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION
MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any third
party any license to these patents, trademarks, copyrights or other intellectual
property rights, except as expressly provided in any written agreement of
ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time,
without being obliged to announce such revisions or changes beforehand or
after the fact.
This manual’s sole purpose is to assist installers and/or users in the safe and
efficient installation and usage of the system and/or product, and/or software
described herein.
B
EFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND THE
USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY
REQUIREMENTS AND OPERATING PROCEDURES
The system must not be used for purposes other than those for which it
was designed.
The use of the software associated with the system and/or product, if
applicable, is subject to the terms of the license provided as part of the
purchase documents.
ROSSLARE exclusive warranty and liability is limited to the warranty and
liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with the
maximum number of functions, including future options. Therefore, not all
functions described in this manual may be available in the specific system
and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively
maintain the system, relieves the manufacturer (and seller) from all or any
responsibility for consequent noncompliance, damage, or injury.
The text, images and graphics contained in the manual are for the purpose
of illustration and reference only.
All data contained herein subject to change without prior notice.
In no event shall manufacturer be liable for any special, direct, indirect,
incidental, consequential, exemplary or punitive damages (including,
without limitation, any and all damages from business interruption, loss of
profits or revenue, cost of capital or loss of use of any property or capital or
injury).
All graphics in this manual are for reference only, some deviation between
the image(s) and the actual product may occur.
All wiring diagrams are intended for reference only, the photograph or
graphic of the PCB(s) are intended for clearer illustration and
understanding of the product and may differ from the actual PCB(s).
.
viii AYC-x6355 Installation and User Manual
Introduction
1. Introduction
The AYC-x6355 is a family of multi-format contactless smart card
convertible integrated readers and controllers for use in access control
system solutions.
The AYC-x6355 series automatically determines whether to function
as a reader or as a controller. If the unit is connected to a standard
access control unit, then it functions as a reader. If the unit is
connected to Rosslare's secure application appurtenances such as the
PS-A25T, PS-C25T or PS-C25TU, it functions as a secured controller.
Both units are water resistant and suitable for indoor or outdoor
mounting. As a controller, the units accept up to 500 users, and allow
entry via a personal identification number (PIN) and/or by presenting a
proximity card. The PIN code length for the controller has several
options. The PIN code length can be a set number of 4, 5, or 6 digits
or it can be a 4-8 digits option.
CSN SELECT readers support reading from the secure memory of the
following credential technologies:
MIFARE Ultralight / Ultralight C
MIFARE Classic
MIFARE Plus S / Plus X
MIFARE DESFire EV1
ISO 14443A
ISO 14443B
ISO 15693
iClass
ISO 18092 (NFCIP-1)
FeliCa
For information on how the unit functions as a reader, see Chapter 6.
For information on how the unit functions as a controller, see
Chapter 8.
AYC-x6355 Installation and User Manual 9
Introduction
1.1 Box Content
Before beginning, verify that all of the following is in the box. If
anything is missing, please report the discrepancy to your nearest
Rosslare office.
One AYC-x6355 unit
Installation kit – Includes two wall plugs, two mounting screws,
security Torx screw, and security Torx screw tool
Installation and operating instructions
1.2 Ancillary Equipment
The following equipment is required to complete your installation:
1.2.1 Reader
Compatible host controller (not supplied) – UL listed access
control unit, such as model AC-215U
1.2.2 Controller
Secure application appurtenances (such as the PS-A25T, PS-C25T
or PS-C25TU secure controllers)
The controller connects to the following:
Electric lock strike mechanism or a magnetic lock device,
which implements fail safe (power to lock) or fail secure
(power to open) functions.
REX button – Normally open type, switch is closed when
pressed.
Door monitor switch
Rosslare accessories can be found on www.rosslaresecurity.com
.
10 AYC-x6355 Installation and User Manual
Technical Specifications
2. Technical Specifications
Electrical Characteristics
Power Supply Type
Operating Voltage Range
Current @ 12 V
Read Range
LED Control Input 1**
Auxiliary Input**
Auxiliary Output**
Maximum Cable Distance
to Controller
Environmental Characteristics
Operating Temp. Range
Operating Humidity Range
Outdoor Usage
* Measured using Rosslare O2S ISO cards. Range also depends on electrical
environment and proximity to metal.
** Standard configuration. Custom configurations are available.
Linear (recommended)
6 to 16 VDC
Standby: 85 mA
Maximum: 110 mA
MIFARE Classic EV1: 40 to 45 mm (1.5 to 1.8
in.)
MIFARE Plus: 30 mm (1.2 in.)
MIFARE DESFire EV1: 30 mm (1.2 in.)
Green LED control, TTL
Buzzer control, TTL
Tamper output (open collector, active low,
max. sink current 30 mA)
Wiegand: 150 m (500 ft) with 18-AWG cable
OSDP (RS-485): 1200 m (4,000 ft) with 2x2
18-AWG twisted shielded cable
-25°C to 65°C (-13°F to 149°F)
0 to 95% (non-condensing)
Weather-resistant, meets IP65, epoxy-potted,
suitable for indoor and outdoor use
AYC-x6355 Installation and User Manual 11
Technical Specifications
Physical Characteristics
Dimensions
(H x W x D)
Weight
AYC-H6255: 110.7 × 75.0 × 18.2 mm
(4.4 x 3.0 x 0.6 in.)
AYC-M6255: 89.5 × 88.9 × 18.3 mm
(3.5 x 3.5 x 0.7 in.)
AYC-H6255: 220 g (7.8 oz)
AYC-M6255: 215 g (7.6 oz.)
12 AYC-x6355 Installation and User Manual
Mounting
To mount the units:
3. Mounting
Before mounting, you should determine the best location for the
reader.
1. Peel off the back of the self-adhesive mounting label template
and place it at the required mounting location.
2. Using the template as a guide, drill two holes (sizes indicated on
the template) used for mounting the back plate onto the surface.
3. Insert a suitable wall plug into each screw hole.
4. Drill a 10-mm (7/16”) hole for the cable. If mounting on metal,
place a grommet or electrical tape around the edge of the hole.
5. Wire the reader as described in Chapter 4. A linear type power
supply is recommended.
6. Remove the reader's snap-off front cover to reveal the two screw
holes (see Figure 1).
Figure 1: Removing the Top Cover
AYC-x6355 Installation and User Manual 13
Mounting
7. Align the two holes of the reader with those drilled in the wall
and firmly attach the reader to the wall with two screws, whose
size is indicated on the template.
8. Relocate the front cover onto the reader.
The reader can also be mounted using strong epoxy glue. After
application, the reader should be firmly held in place until the
glue dries
14 AYC-x6355 Installation and User Manual
Wiring Instructions
To connect a pigtail reader to the controller:
4. Wiring Instructions
The units are supplied with a 10-conductor 18” (46 cm) pigtail or
with 10 terminal blocks.
1. Prepare the reader cable by cutting its jacket back 3.2 cm (1¼”)
and strip the insulation from the wires 1.3 cm (½").
2. Prepare the controller cable by cutting its jacket back 3.2 cm
(1¼") and strip the insulation from the wires 1.3 cm (½").
3. Splice the reader’s pigtail wires to the corresponding controller
wires (as indicated in Table 1) and cover each joint with insulating
tape.
Table 1: Wiring
Terminals Wire Color Output
1 Red Power
2 Black Ground
3 Green Data 0 / Data
4 White Data 1 / Clock
5 Blue OSDP / RS-485-A2
6 Gray OSDP / RS-485-B2
7 Orange LED Control 1
8 Brown LED Control 2
9 Yellow Auxiliary Input
10 Purple Tamper Output
4. If the tamper output is being utilized, connect the purple wire to
the correct input on the controller.
The LED control may be configured by the factory to function
either as a LED control or as buzzer control. Currently, Auxiliary
Input is used as buzzer control and LED Control 1 is used as the
green LED control.
5. Trim and cover all unused conductors.
AYC-x6355 Installation and User Manual 15
Wiring Instructions
earth ground, or a signal ground connection at the panel, or power
• The individual wires from the reader are color coded according the
Wiegand standard.
• When using a separate power supply for the reader, this supply and
that of the controller must have a common ground.
• The reader’s cable shield wire should be preferably attached to an
supply end of the cable. This configuration is best for shielding the
reader cable from external interference.
16 AYC-x6355 Installation and User Manual
Reader Operation
To test the reader:
5. Reader Operation
Once the reader is wired to a power supply and to the controller, you
should test the reader.
1. Power up the reader.
To indicate that the reader is working properly, the reader flashes
red, then green, and then orange, each for 1 second and a beep
is heard for each color. The LED returns to its idle state (red).
2. Present the appropriate type of proximity card to the reader.
The LED momentarily flashes green and a short beep is emitted
indicating that the card was read properly by the reader.
The reader transmits the card's data to the controller.
AYC-x6355 Installation and User Manual 17
OSDP Operation
6. OSDP Operation
CSN SELECT readers that support OSDP operation are compatible
with most OSDP commands. The reader address is set using DIP
switches on the back of the reader.
The DIP switch settings are as follows:
DIP Switch 1
This switch is used to select the reader output (Wiegand or OSDP):
Off = Wiegand
On = OSDP
DIP Switch 2
This switch is reserved for future use.
DIP Switch 3
This switch is reserved for future use.
DIP Switches 4 to 8
These switches set the address of the reader for OSDP protocol.
DIP Switch 4 is MSB and DIP Switch 8 is LSB. The address is the DIP
switch state +1.
Examples:
All the DIP switches in Off position, state is = 0 => address = 1
All the DIP switches in On position, state is = 0x1F => address =
0x20 = 32
DIP switches 4, 6, 8 in On position and 5, 7 in Off position, state
is = 0x15 => address = 0x16 = 22
18 AYC-x6355 Installation and User Manual
Reader Functionality
reader is in Transmit mode,
Mode/Transmit
Door/ Progra m
Red
Mode/Transmit
Door/ Progra m
Green
7. Reader Functionality
Upon power-on reset, the unit searches for the presence of Rosslare's
secure application appurtenances. If a secured controller is not
detected, it is automatically configured as a reader, as indicated by
the red Mode LED.
This chapter explains how the AYC-x6355 series functions as a reader.
7.1 Transmit Mode
When the unit is in Transmit mode, it is ready to receive data from a
presented proximity card or from an entered PIN code.
When the
the Transmit LED is red and the
Program LED is off.
When a proximity card or PIN entry is
being transmitted, the Transmit LED
flashes green.
Keyboard data can be sent via one of eight different Keypad
Transmission Formats (see Section 7.2.3).
Proximity cards presented to the reader are always sent in either
Wiegand 26-Bit or Clock & Data format (see Section 7.2.4).
7.2 Programming the AYC-x6355 Series
Programming the AYC-x6355 is done solely via the unit's keypad
driven Programming Menu System. During the AYC-x6355’s
manufacturing process, certain codes and settings are preprogrammed. These settings are called the default factory settings.
Table 2 shows the names of all the AYC-x6355 reader menus.
Default factory settings are marked by a "*" sign.
AYC-x6355 Installation and User Manual 19
Reader Functionality
Table 2: Reader Programming Menus
Menu Description Default
1 Selecting Keypad Transmission Format
Single Key, 6-Bit Wiegand (Rosslare Format)
Single Key, 6-Bit Wiegand with Nibble + Parity Bits
Single Key, 8-Bit Wiegand, Nibbles Complemented
4 Keys Binary + Facility Code, Wiegand 26-Bit
1 to 5 Keys + Facility Code, Wiegand 26-Bit
6 Keys BCD and Parity Bits, Wiegand 26-Bit
1 to 8 Keys BCD, Clock & Data
Single Key, Wiegand 4-Bit
2 Selecting Card Transmission Format
Wiegand 26-Bit
Clock & Data
3 Changing the Programming Code 1234
4 Changing the Facility Code 0
6 Backlight Options
Off
On (Default)
Off until key press when on for 10 seconds
Dimmed until key press when on for 10 seconds
0 Return to Factory Default Settings
*
*
*
20 AYC-x6355 Installation and User Manual