Rosslare AYCF6X User Manual

AYC-F/G/M60 Series
Convertible Reader with Genuine
HID Technology
Installation and Programming Manual
AYC-F60 AYC-G60 AYC-M60
Copyright © 2017 by Rosslare. All rights reserved.
This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
Table of Contents
Table of Contents
1. Introduction ................................................................ 9
1.1 Box Content ........................................................................... 9
1.2 Ancillary Equipment .............................................................. 10
2. Technical Specifications ............................................ 11
3. Installation ................................................................ 13
3.1 Mounting ............................................................................. 13
3.2 Wiring .................................................................................. 14
3.2.1 Wiring the Unit as a Reader .......................................................... 14
3.2.2 Wiring the Unit as a Controller ..................................................... 15
4. Reader Operation ...................................................... 18
4.1 Standby Mode ...................................................................... 18
4.2 Programming as a Reader ...................................................... 18
4.2.1 Entering Programming Mode ........................................................ 20
4.2.2 Exiting Programming Mode .......................................................... 20
4.2.3 Selecting Keypad Transmission Format ......................................... 21
4.2.4 Selecting HID Prox Card Transmission Format ............................... 26
4.2.5 Selecting Rosslare Proximity Card Transmission Format ................. 26
4.2.6 Changing the Programming Code ................................................ 28
4.2.7 Changing the Facility Code ........................................................... 29
4.2.8 Setting the Backlight Behavior ...................................................... 29
4.2.9 Setting the Credential Format ....................................................... 30
4.2.10 Return to Factory Default Settings ................................................ 30
4.2.11 Replacing a Lost Programming Code ............................................ 31
5. Controller Operation ................................................. 32
AYC-F/G/M60 Series Installation and Programming Manual iii
Table of Contents
5.1 Normal, Secure, and Master Users .......................................... 32
5.2 Modes of Operation .............................................................. 33
5.2.1 Normal Mode ............................................................................... 33
5.2.2 Bypass Mode ................................................................................ 33
5.2.3 Secure Mode ................................................................................ 34
5.2.4 Changing the Modes of Operation ............................................... 34
5.3 Auxiliary Input and Output..................................................... 36
5.4 Door Alarms ......................................................................... 36
5.5 Internal Case and Back Tamper .............................................. 36
5.6 Lockout Feature (Keypad/Card Tamper) .................................. 36
5.7 REX Function ........................................................................ 37
5.8 Secured Intelligent Power Supply ........................................... 37
5.9 Programming as a Controller ................................................. 38
5.9.1 Entering Programming Mode ........................................................ 39
5.9.2 Exiting Programming Mode .......................................................... 39
5.9.3 Changing Lock Strike Code .......................................................... 40
5.9.4 Changing Auxiliary Code .............................................................. 40
5.9.5 Changing the Programming Code ................................................ 41
5.9.6 Changing the Normal/Secure Code .............................................. 42
5.9.7 Changing the Normal/Bypass Code and Door Chime Settings ...... 42
5.9.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike
Release Time ................................................................................. 43
5.9.9 Defining the Auxiliary Input and Output ....................................... 44
5.9.10 Setting the Lockout Feature .......................................................... 51
5.9.11 Setting the Backlight Behavior ...................................................... 52
5.9.12 Selecting the Credential Format .................................................... 52
5.9.13 Enrolling Primary and Secondary Codes ........................................ 53
5.9.14 Deleting Primary and Secondary Codes ......................................... 56
iv AYC-F/G/M60 Series Installation and Programming Manual
Table of Contents
5.9.15 Relay Codes Assignment ............................................................... 59
5.9.16 PIN Code Length/Factory Default Settings ..................................... 61
5.9.17 Replacing a Lost Programming Code ............................................ 62
5.9.18 Replacing a Lost Normal/Secure Code ........................................... 62
A. Declaration of Conformity........................................ 63
B. Limited Warranty ...................................................... 64
AYC-F/G/M60 Series Installation and Programming Manual v
List of Figures
List of Figures
Figure 1: Drilling and Mounting Holes ............................................................. 13
Figure 2: Controller Application Wiring Diagram ............................................. 16
Figure 3: Controller Wiring – Using the Internal Power .................................... 17
Figure 4: Controller Wiring – Using the External Power ................................... 17
vi AYC-F/G/M60 Series Installation and Programming Manual
List of Tables
List of Tables
Table 1: Wiring the Reader to the Controller ................................................... 14
Table 2: Wiring the Unit as a Controller........................................................... 15
Table 3: Reader Programming Menu ............................................................... 19
Table 4: Controller Programming Menu .......................................................... 38
Table 5: Quick Reference Guide for Auxiliary Mode Setting ............................. 46
AYC-F/G/M60 Series Installation and Programming Manual vii
Notice and Disclaimer
Notice and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein.
B
EFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND THE
USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING PROCEDURES
The system must not be used for purposes other than those for which it
was designed.
The use of the software associated with the system and/or product, if
applicable, is subject to the terms of the license provided as part of the purchase documents.
ROSSLARE exclusive warranty and liability is limited to the warranty and
liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with the
maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively
maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury.
The text, images and graphics contained in the manual are for the purpose
of illustration and reference only.
All data contained herein subject to change without prior notice.
In no event shall manufacturer be liable for any special, direct, indirect,
incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury).
All graphics in this manual are for reference only, some deviation between
the image(s) and the actual product may occur.
All wiring diagrams are intended for reference only, the photograph or
graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s).
.
viii AYC-F/G/M60 Series Installation and Programming Manual
Introduction

1. Introduction

The AYC-F/G/M60 is a series of Rosslare goPROX & PIN readers with Genuine HID Technology technology.
These units automatically determine whether to function as a reader or as a secured standalone controller. If the unit is connected to a standard access control unit, then it functions as a reader. If the unit is connected to a Rosslare secured intelligent power supply such as the PS-A25T, PS-C25T, or PS-C25TU, it functions as a secured standalone controller.
As a reader, the units can read all HID Prox cards/tags (125 kHz FSK) using Genuine HID Technology and outputs HID Prox card data in Wiegand according to the number of bits of data stored on the card. The units also read Rosslare proximity cards (125 kHz) and can output Rosslare proximity card data as Wiegand 26-Bit, Clock & Data, and Wiegand + PIN.
As a controller, the units accept up to 500 users, and allow entry via a personal identification number (PIN) and/or by presenting a proximity card. The PIN code length for the controller has several options. The PIN code length can be a set number of 4, 5, or 6 digits or it can be flexible from 4 to 8 digits.

1.1 Box Content

Before beginning, verify that all of the following is in the box. If anything is missing, please report the discrepancy to your nearest Rosslare office.
One AYC-F/G/M60 unit Installation kit Installation and operating instructions
, as well as Rosslare's Convertible
AYC-F/G/M60 Series Installation and Programming Manual 9
Introduction

1.2 Ancillary Equipment

The following equipment is required to complete your installation:
When functioning as a reader:
Compatible Host Controller (not supplied) – Any host controller that accepts either Wiegand or Clock & Data communication protocols. Multiple keypad formats are supported. For a complete list, see Section 4.2.3. UL installations require a UL listed access control units such as Rosslare's AC-215U and AC-225U.
When functioning as a controller:
Secured intelligent power supply – such as the PC-25T, PS-A25T, PS-C25T, or PS-C25TU secure controllers.
Only PS-C25TU can be used for UL-294 compliant installations.
This unit connects to the following:
Electric lock strike mechanism or a magnetic lock device,
which implements fail safe (power to lock) or fail secure (power to open) functions
Request to Exit (REX) button – normally open type. Switch is
closed when pressed.
Door monitor switch
Rosslare accessories can be found on www.rosslaresecurity.com
.
10 AYC-F/G/M60 Series Installation and Programming Manual
Technical Specifications

2. Technical Specifications

Electrical Characteristics
Power Supply Type
Operating Voltage Range
Input current standby (12 VDC)
Input Current Max (16 VDC)
LED Control Input
Tamper Output
Cable Distance to Host Controller
Max. Proximity Card Read Range*
Proximity Card Modulation
Proximity Card Compatibility
Card Transmit Format (Reader)
Keypad Transmit Format (Reader)
LED Indicators
Communication
* Measured using a Rosslare proximity card or equivalent. Range also
depends on electrical environment and proximity to metal.
Linear (recommended)
5–16 VDC (when used as a controller, provided by the secured intelligent power supply)
100 mA
140 mA
Dry contact N.O.
Open collector, active low, 32 mA max sink current
Up to 150 m (500 ft) using an 18 AWG cable
60 mm (2.4 in.)
Rosslare proximity/HID Prox at 125 kHz
Rosslare proximity/HID Prox cards
Rosslare proximity cards: Wiegand 26-Bit, or Clock & Data
HID Prox cards: According to card type
Programmable PIN code formats (see Section
4.2.3)
Two tri-colored LEDs
Data1/C1, Data0/C2–open collector, 5 V termination
AYC-F/G/M60 Series Installation and Programming Manual 11
Technical Specifications
Environmental Characteristics
Operating Temp. Range
Operating Humidity Range
Outdoor Usage
-30°C to 65°C (-22°F to 150°F)
0 to 95% (non-condensing)
Weather-resistant, meets IP65, epoxy-potted, suitable for indoor and outdoor use
Physical Characteristics
Size (Height x Width x Depth)
Weight
F: 120 x 76 x 21 mm (4.7 x 3.0 x 0.8 in.)
G: 137 x 44 x 21 mm (5.4 x 1.7 x 0.8 in.)
M: 93 x 93 x 18 mm (3.6 x 3.6 x 0.7 in.)
F: 230 g (8.1 oz)
G: 175 g (6.2 oz)
M: 185 g (6.5 oz)
12 AYC-F/G/M60 Series Installation and Programming Manual
Installation
To mount the unit:

3. Installation

Installation of an RFID reader adjacent to metallic surfaces might alter the reader’s specifications. To diminish this interference, use a plastic spacer when mounting the reader.
Before starting, select the location to mount the unit. This location should be at shoulder height.

3.1 Mounting

Before starting, select the location to mount the unit. This location should be at shoulder height.
1. Peel off the back of the self-adhesive installation template and attach the template to the required location.
2. Using the template as a guide, drill holes according to how you want to mount the unit (Figure 1).
Figure 1: Drilling and Mounting Holes
AYC-F60 AYC-G60 AYC-M60
3. Drill a 10-mm (7/16”) hole for the cable. If the surface is metal, place a grommet or electrical tape around the edge of the hole.
4. At the bottom of the unit’s case, remove the screw.
5. Carefully remove the snap-off front cover of the unit to reveal the screw holes.
AYC-F/G/M60 Series Installation and Programming Manual 13
Installation
To connect the unit as a reader (to a controller):
6. Insert the unit’s cable wire into the cable hole and wire the unit as described in Section 3.2.
7. Screw the back cover to its mounting location.
8. Carefully re-attach the front cover of the unit.
9. Secure the front cover by using the supplied security Torx screw. A Torx security screw tool is provided to tighten the security Torx screw.

3.2 Wiring

The unit is supplied with a 6-conductor 56-cm (22-in.) pigtail with exposed wires coated with solder.

3.2.1 Wiring the Unit as a Reader

If you connect the unit to a standard access control unit, it automatically functions as a reader.
1. Select the appropriate connections according to Table 1.
Table 1: Wiring the Reader to the Controller
Wire Color Function
Black/Shield Ground (+)
Red Vin (-)
Green Data 0/Data (D0)
White Data 1/Clock (D1)
Brown LED control
Purple Tamper
2. Prepare the controller cable by cutting the cable jacket back 3.2 cm (1¼”) and strip the wire 1.3 cm (½”).
3. Splice the reader’s pigtail wires to the corresponding controller wires and cover each joint with insulating tape.
4. If the tamper output is being utilized, connect the purple wire to the correct input on the controller.
14 AYC-F/G/M60 Series Installation and Programming Manual
Installation
nnection at the panel or power supply end of
the cable. This configuration is best for shielding the reader cable from
To connect the unit as a controller:
5. Trim and cover all conductors that are not used.
The individual wires extending from the reader are color-coded according to the required Wiegand standard.
When using a separate power supply for the reader, this supply and the controller’s power supply must have a common ground. A linear power supply is recommended.
Attach the cable shield wire on the reader to an earth ground (best), or to a signal ground co
external interference.

3.2.2 Wiring the Unit as a Controller

If you connect the unit to a Rosslare PS-x25x secured power supply, it automatically functions as a controller.
1. Select the appropriate connections according to Table 2.
Table 2: Wiring the Unit as a Controller
Controller Wire Color Func tion Note
- Red +DC Input Wired to the PS-x25x
+ Black Ground Wired to the PS-x25x
C 1 White Communication Wired to the PS-x25x
C 2 Green Communication Wired to the PS-x25x
AUX. IN Brown Auxiliary Input Wired to input
N/A
Attach the cable shi eld wire on the unit to an earth ground (best). You can also attach it to a signal ground connection at the p anel or power supply end of the cable. This configuration is best for shiel ding the controller cable from external interference.
Purple Not in use N/A
2. Prepare the PS-x25x secured power supply’s cable by cutting the cable jacket back 3.2 cm (1¼”) and strip the wire 1.3 cm (½”).
3. Splice the controller pigtail wires to the corresponding PS-x25x secured power supply’s wires and cover each joint with insulating tape.
AYC-F/G/M60 Series Installation and Programming Manual 15
Installation
4. Trim and cover all conductors not used.
5. To connect the unit to the desired power supply option, refer to the relevant wiring diagrams that follow.
Figure 2 shows the wiring for the controller application using a dual relay secured intelligent power supply.
Figure 2: Controller Application Wiring Diagram
16 AYC-F/G/M60 Series Installation and Programming Manual
Installation
Figure 3 shows the auxiliary output connection using the internal power.
Figure 3: Controller Wiring – Using the Internal Power
Transorb:1.5
KE
77c-Connect to load terminals
(optional transorb for inductive loads,not supplied)
Figure 4 shows the auxiliary output connection using the external power.
Figure 4: Controller Wiring – Using the External Power
(optional transorb for inductive loads,not supplied)
AYC-F/G/M60 Series Installation and Programming Manual 17
Reader Operation
Green
Red

4. Reader Operation

The AYC-F/G/M60 series can function both as a reader and as a controller. If the unit is connected to standard access controller, it functions as a reader, indicated by one beep immediately after power­on reset.

4.1 Standby Mode

The default mode of the reader is Standby mode. In Standby mode, the unit is ready to receive data from a presented proximity card or an entered PIN code.
When the reader is in Standby mode, the left LED is red and the right LED is off.
When a proximity card is presented or a keypad entry is being transmitted, the left LED flashes green.
Keypad data can be sent via one of eight keypad transmission formats. For more information, see Section 4.2.3.
Rosslare proximity cards presented to the reader can output card data as Wiegand 26-Bit, Clock & Data, and Wiegand + PIN. See Section
4.2.5 for more information.
HID Prox card data is output in Wiegand according to the number of bits of data stored on the card. See Section 4.2.4 for more information.

4.2 Programming as a Reader

Programming is done solely via the unit's keypad driven Programming Menu System. During the unit’s manufacturing process, certain codes and settings are pre-programmed. These settings are called the default factory settings.
18 AYC-F/G/M60 Series Installation and Programming Manual
Reader Operation
Table 3 shows the names of all the reader programming menus.
Default factory settings are marked by *.
Table 3: Reader Programming Menu
Menu Description Default
1 Selecting Keypad Transmission Format
Single Key, Wiegand 6-Bit (Rosslare Format) Single Key, Wiegand 6-Bit with Nibble + Parity Bits Single Key, Wiegand 8-Bit, Nibbles Complemented 4 Keys Binary + Facility code, Wiegand 26-Bit 1 to 5 Keys + Facility code, Wiegand 26-Bit 6 Keys Binary-Coded Decimal (BCD) and Parity Bits, Wiegand
26-Bit Single Key, 3x4 Matrix Keypad 1 to 8 Keys BCD, Clock & Data Single key, Wiegand 4-Bit
2 Selecting Rosslare Proximity Card Transmission Format
Wiegand 26-Bit Clock & Data Wiegand Card + PIN
3 Changing the Programming code
4 Changing the Facility code
6 Setting the Backlight
Always off Always on 10 sec. backlight after key press otherwise off 10 sec. backlight after key press otherwise dimmed
6 Setting Credential Format
Rosslare Proximity HID Prox Rosslare Proximity + HID Prox
0 Return to Factory Default Settings
*
*
1234
0
*
*
AYC-F/G/M60 Series Installation and Programming Manual 19
Reader Operation
To enter Programming mode:
To exit Programming mode:
Red
Green

4.2.1 Entering Programming Mode

To reach the Programming Menu System, the unit must first be placed into Programming mode.
The factory 4-digit Programming code is 1234.
If a Programming code is not entered within 30 seconds, the unit
returns to Standby mode.
1. Press # four times.
The left LED turns off and the right LED turns red.
2. Enter your 4-digit Programming code.
If the Programming code is valid, the right LED turns green.
If the Programming code is invalid, you hear a long beep and the reader returns to Standby mode.

4.2.2 Exiting Programming Mode

1. Press # to exit Programming mode at any time.
You hear a beep.
The left LED turns red and the right LED
turns off.
This indicates that the unit has returned to Standby mode.
Wrong entries may reset the reader back to Standby mode. If no key is pressed for 30 seconds while in Programming mode, the unit exits Programming mode and returns to Standby mode.
20 AYC-F/G/M60 Series Installation and Programming Manual