Rosslare AuraSys L-2, AuraSys L-2K Hardware Installation Manual

Page 1
AuraSys™ L-2
2-/4-Zone Alarm Access Panel
Hardware Installation Manual
Models:
L-2 L-2K
Page 2
Copyright © 2012 by Rosslare. All rights reserved.
This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
Page 3
Table of Contents
AuraSys™ L-2 and L-2K Installation Manual iii
Table of Contents
1. Introduction ....................................................................... 8
2. Technical Specifications and Features .......................... 10
3. Installation and Wiring .................................................. 12
3.1 Installation Quick Guide .................................................................... 12
3.2 Installation Prerequisites .................................................................... 12
3.2.1 Preparing the Installation Environment ....................................................... 12
3.2.2 Preparing the Wiring ................................................................................. 12
3.2.3 Mounting the Control Panel....................................................................... 13
4. Wiring Instructions ......................................................... 15
4.1 Wiring Quick Reference .................................................................... 15
4.2 Wiring the System ............................................................................ 16
4.2.1 AC/DC Wiring ........................................................................................... 16
4.2.2 Battery Connection .................................................................................... 16
4.2.3 Telephone Wiring ...................................................................................... 16
4.2.4 PGM Connection ....................................................................................... 17
4.2.5 Smoke Detector Connections ..................................................................... 17
4.2.6 Zone Wiring .............................................................................................. 19
4.2.7 Sounder Connections ................................................................................ 23
4.3 Preliminary Testing ............................................................................ 23
5. Programming ................................................................... 24
5.1 Connections ..................................................................................... 24
5.2 Programming Options ....................................................................... 24
A. Battery Load Capacity .................................................... 25
B. Expansions and Accessories........................................... 26
B.1 MD-31 (RJ-31X Jack) ......................................................................... 26
B.2 SA-59 GSM Communicator ............................................................... 27
C. Reporting Codes .............................................................. 29
D. Useful Information and Tables ...................................... 31
Page 4
Table of Contents
iv AuraSys™ L-2 and L-2K Installation Manual
D.1 Customer Information....................................................................... 31
D.2 Installer Information .......................................................................... 31
D.3 Device Information ........................................................................... 31
D.4 Zone Worksheet ............................................................................... 32
E. Limited Warranty ............................................................ 33
Page 5
List of Figures
AuraSys™ L-2 and L-2K Installation Manual v
List of Figures
Figure 1: L-2 Control Panel ............................................................................. 8
Figure 2: L-2K Control Panel ........................................................................... 9
Figure 3: L-2/2K Mounting Template ............................................................ 14
Figure 4: L-2/2K Control Panel Components ................................................. 15
Figure 5: Battery Connection Diagram .......................................................... 16
Figure 6: Telephone Diagram ........................................................................ 17
Figure 7: PGM Wiring Diagram ..................................................................... 17
Figure 8: Smoke Detectors without Reset Mechanism ................................... 18
Figure 9: Smoke Detectors with Reset Mechanism ........................................ 19
Figure 10: Resistors ...................................................................................... 22
Figure 11: Sounder (bell) Connections .......................................................... 23
Figure 12: Rosslare's MD-62 TTL to RS-232 Converter ................................... 24
Figure 13: MD-31 Dimensions ...................................................................... 26
Figure 14: MD-31 Internal Wiring ................................................................. 26
Figure 15: MD-31 to Alarm Panel Wiring ...................................................... 27
Figure 16. Universal GSM Communicator ..................................................... 28
Page 6
List of Tables
vi AuraSys™ L-2 and L-2K Installation Manual
List of Tables
Table 1: Hardwiring Schematics for Single Zone System ................................ 20
Table 2: Hardwiring Schematics for Doubled Zone System ............................ 21
Table 3: Resistor Color Scheme ..................................................................... 22
Table 4: Resistors Provided ........................................................................... 22
Table 5: Battery Load Capacity ..................................................................... 25
Table 6: Event Codes: Contact ID and SIA - Burglary and Fire ........................ 29
Table 7: Event Codes: Contact ID and SIA - Arming Events ............................ 29
Table 8: Event Codes: Contact ID and SIA - System Events ............................ 29
Page 7
Notice and Disclaimer
AuraSys™ L-2 and L-2K Installation Manual vii
Notice and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein.
B
EFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND
THE USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY
REQUIREMENTS AND OPERATING PROCEDURES
.
The system must not be used for purposes other than those for which it
was designed.
The use of the software associated with the system and/or product, if
applicable, is subject to the terms of the license provided as part of the purchase documents.
ROSSLARE exclusive warranty and liability is limited to the warranty and
liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with the
maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively
maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury.
The text, images and graphics contained in the manual are for the
purpose of illustration and reference only.
All data contained herein subject to change without prior notice. In no event shall manufacturer be liable for any special, direct, indirect,
incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury).
All graphics in this manual are for reference only, some deviation between
the image(s) and the actual product may occur.
All wiring diagrams are intended for reference only, the photograph or
graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s).
Page 8
Introduction
8 AuraSys™ L-2 and L-2K Installation Manual
1. Introduction
The AuraSys™ L-2 (and L-2K), 2/4-zone security system, is a compact and advanced 2-zone (doubled) hardwired control panel for residential and light commercial intrusion alarms.
There are currently two versions of the L-2 product:
L-2 – Away/disarm using key switch L-2K – Local arming using numeric keypad
Figure 1: L-2 Control Panel
Page 9
Introduction
AuraSys™ L-2 and L-2K Installation Manual 9
Figure 2: L-2K Control Panel
Page 10
Technical Specifications and Features
10 AuraSys™ L-2 and L-2K Installation Manual
2. Technical Specifications and Features
The AuraSys L-2 family supports a wide range of security features. This section lists the specifications for the features that comprise the security system, as well as the electrical and mechanical specifications of the security system.
General Attributes
Onboard dual EOL zone inputs (+ tamper detection)
2
Tamper Protection
Back and Front Cover
Zone doubling
Yes
Max. supported zones
4
Onboard PGM output
1 x OC 120 mA
Sounder output
1 x 1 Ampere
Onboard AUX output
+12 VDC 1.0 Ampere
User codes
6 (in L-2K)
Non-volatile event log size
256
Central station accounts (primary, secondary/backup)
Yes
Private telephone numbers
Yes (3)
Electrical Characteristics
Power Supply Type
Linear type (recommended)
Input Voltage
16 VAC with 20 VA transformer (14–18 VAC 50/60 Hz Range)
24 VDC 1A (20 to 30 VDC Range)
Input Current
Standby – 90 mA Maximum – 258 mA
Battery BT-05
Type
SLA (Sealed Lead Acid)
Voltage
12 V
Capacity
800 mAh
Backup/Recharge Period
See Appendix
A
Page 11
Technical Specifications and Features
AuraSys™ L-2 and L-2K Installation Manual 11
Battery BT-16
Type
NiMH (Nickel Metal Hydride)
Voltage
12 V
Capacity
2 Ah
Backup/Recharge Period See Appendix A
Environmental Characteristics
Operating Environment
Indoor use only
Operating Temperature Range
-15ºC to 44°C (5ºF to 111.2°F)
Operating Humidity Range
0 to 95% (non-condensing)
RFI Protection
> 20 V/m up to 1000 MHz
Supervision
Tamper-proof system with constant supervision
Mechanical Specifications
Dimensions Height x Width x Depth
130 x 170 x 38 mm (5.1 x 6.7 x 1.5 in.)
Weight (without battery)
250 g (8.8 oz.)
Page 12
Installation and Wiring
12 AuraSys™ L-2 and L-2K Installation Manual
3. Installation and Wiring
This chapter provides steps for installing the AuraSys L-2 and L-2K devices. It also includes a Quick Guide for fast reference as well as a reference section for wiring the system.
3.1 Installation Quick Guide
There are a number of steps to installing the unit:
Step Action Section
Preparing the Installation Environment 3.2.1
Preparing the Wiring 3.2.2
Mounting the Control Panel
3.2.3
Wiring the L-2 System 4
3.2 Installation Prerequisites
Unit installation is limited to the control panel. Installation instructions for additional communication modules are included in appendices in this manual. For information on installing the various detectors, please refer to the individual manuals supplied with the detector.
3.2.1 Preparing the Installation Environment
Establish the control panel location using the following guidelines:
Locate the control panel in a place where the temperature is within the
specified limits for operation.
When distributing wiring, avoid putting the system wires close to house
wiring to reduce capacitive coupling of noise.
Locate the control panel in the center of the premises to avoid long runs
to any one location.
Install the panel 130 cm +/- 10 cm from the floor. Make sure to leave 15
cm all around the control panel for ventilation and/or wiring entry. The panel should be installed at eye level to ease in making connections or repairs.
3.2.2 Preparing the Wiring
The control panel provides 12 VDC up to 1 Ampere for PGM add-ons and sensors. The maximum wire length between the panel and accessories depends on the amount of current drawn by the accessory and the gauge of the conductors (wires) used.
Page 13
Installation and Wiring
AuraSys™ L-2 and L-2K Installation Manual 13
3.2.3 Mounting the Control Panel
The L-2 control panel family comes in two enclosed versions:
L-2 – Plastic enclosure with 2-state key switch L-2K – Plastic enclosure with 6-button arming keypad
Follow the below instruction to mount the L-2 control panel family.
To mount the L-2 and L-2K panel:
1. Using a Philips head screwdriver, unscrew the enclosure screws and open
the L-2/2K enclosure.
2. Use the mounting template as shown in Figure 3 to drill holes in the wall.
3. Insert masonry anchors into the drilled holes.
4. Remove the PCB from the enclosure by gently pressing the PCB clasps to
release the PCB from the enclosure.
5. Use a flat head screwdriver to gently remove the plastic knockouts of both
the wiring hole and screw placement.
The bottom left mounting location is required for the back tamper protection, and is the only hole without a knockout.
6. Thread the wires through the wiring hole and wire the unit as explained
ahead in Chapter
4.
7. Secure the L-2/2K panel to the wall using the supplied mounting screws.
The tamper screw is different from the mounting screws. The mounting screws are pan head screws while the tamper screw is a unique flat head screw.
8. Place the PCB back into the back case of the enclosure; ensure that the
claps are holding the PCB in place.
9. Close and secure the enclosure using a Philips head screwdriver.
Page 14
Installation and Wiring
14 AuraSys™ L-2 and L-2K Installation Manual
Figure 3: L-2/2K Mounting Template
Page 15
Wiring Instructions
AuraSys™ L-2 and L-2K Installation Manual 15
4. Wiring Instructions
This section instructs you on how to wire the L-2/2K system and describes the preliminary test performed after completing wiring the system.
4.1 Wiring Quick Reference
The PCB board and components, as well as general connections from the control panel PCB to other panel components, are shown below:
Figure 4: L-2/2K Control Panel Components
Connector Function
+ BAT –
BT-05/16 battery connector
VIN AC/DC
Power input for AC/DC Voltage
+ Bell -
Bell/Siren connection
PGM
Programmable open collector output
+ AUX -
12 VDC power supply for external devices
Z1…Z2
Zones 1 and 2 input connections
-
Common (ground)
Line
Tip and Ring connection for phone line in
Phone
Tip and Ring connection for phone line out
PC connection
MD-62 connection to AuraSys PC software
Page 16
Wiring Instructions
16 AuraSys™ L-2 and L-2K Installation Manual
4.2 Wiring the System
General connections from the PCB in the control panel to other panel components are shown in the wiring diagram in Figure 4.
4.2.1 AC/DC Wiring
The preferable power input for the system is via an AC adaptor; however, you have the option to connect the system to a DC power supply as well. Wire the AC/DC power supply to the Volt IN terminal blocks (VIN + and -) located on the PCB. Refer to Figure 4 to locate the appropriate connectors.
The AC range is between 14-18 VAC, limited up to 1.2 A. Refer to Chapter
2
for detailed electrical characteristics of the transformer.
4.2.2 Battery Connection
To connect the battery to the panel:
1. Place the battery in the battery housing within the enclosure.
2. Connect the battery’s plug to the dedicated battery power jack on the
PCB.
Figure 5: Battery Connection Diagram
See Chapter
2 for detailed battery related information.
RISK OF FIRE, EXPLOSION AND BURNING
If replaced by incorrect battery type
Do not disassemble, expose to excessive heat or incinerate.
• Dispose used batteries in appropriate container.
4.2.3 Telephone Wiring
See Figure 6 for the telephone wiring diagram to the control panel. It is important to connect the control panel to a good ground, to prevent false ringing.
Page 17
Wiring Instructions
AuraSys™ L-2 and L-2K Installation Manual 17
Figure 6: Telephone Diagram
In the United States, do not connect directly to the phone line; instead use Rosslare’s MD-31 RJ-31X jack to connect to a phone line, as explained in Appendix A.
4.2.4 PGM Connection
The onboard PGM output is an open-collector output with a 120 mA drive capability. The output can be connected to the AUX+, as shown in Figure 7 or to an external power supply.
Figure 7: PGM Wiring Diagram
4.2.5 Smoke Detector Connections
Smoke detectors that have a 2-wire input are wired exactly like zones. To support four-wire smoke detectors, the PGM output must be used as a
reset trigger (see Figure 8). For smoke detectors with internal reset mechanism the PGM output is used for
power supervision purposes (see Figure 9).
For 4-wire fire/smoke detectors, use the following settings:
Zone input type Single N.O.
Attached PGM PG M 1
Zone Functional Type 24-Hour Fire 4-Wires
• PGM Activation Trigger Fire Detector Control
LINE PHONE
Page 18
Wiring Instructions
18 AuraSys™ L-2 and L-2K Installation Manual
Figure 8: Smoke Detectors without Reset Mechanism
Page 19
Wiring Instructions
AuraSys™ L-2 and L-2K Installation Manual 19
Figure 9: Smoke Detectors with Reset Mechanism
4.2.6 Zone Wiring
4.2.6.1 Single Zone Wiring
Refer to Table 1 for hard wiring schematics of the AuraSys L-2 system zones:
Normally Closed  Normally Open  Normally Closed + End-of-Line  Normally Closed + End-of-Line + Tamper
Page 20
Wiring Instructions
20 AuraSys™ L-2 and L-2K Installation Manual
Table 1: Hardwiring Schematics for Single Zone System
4.2.6.2 Zone Doubling
Refer to Table 2 for hard wiring schematics of the AuraSys L-2 system for doubled zones:
Doubled Zone – Normally Closed  Doubled Zone – Normally Open  Doubled Zone – Normally Closed + End-of-Line  Doubled Zone – Normally Closed + End-of-Line + Tamper
Page 21
Wiring Instructions
AuraSys™ L-2 and L-2K Installation Manual 21
Table 2: Hardwiring Schematics for Doubled Zone System
4.2.6.3 Resistors
The AuraSys L-2/2K comes with 3 resistors for the various zones connections, including tamper and EOL detection.
The resistors are: 2.2 KΩ, 4.7 KΩ and 8.2 KΩ
Page 22
Wiring Instructions
22 AuraSys™ L-2 and L-2K Installation Manual
Figure 10, Table 3 and Table 4 help to understand the resistor color scheme:
Figure 10: Resistors
Stripes 1&2 represent numbers that together with stripe 3 represent the number of zeros represents the resistor’s value in Ohm. Stripe 4 represents the tolerance. All resistors provided by Rosslare have a 5% tolerance represented by the color Gold. To read the resistor number, hold the unit with the gold stripe on the right.
The color scheme is as follows:
Table 3: Resistor Color Scheme
Black
0
Brown
1
Red 2
Orange 3
Yellow 4
Green
5
Blue 6
Violet 7
Grey 8
White
9
Based on the above color scheme, the resistors provided are as follows:
Table 4: Resistors Provided
Color Resisitor
  
2.2K
Red Red Red
4.7K
Yellow Violet Red
8.2K
Grey Red Red
Page 23
Wiring Instructions
AuraSys™ L-2 and L-2K Installation Manual 23
4.2.7 Sounder Connections
Sounder connections are shown in Figure 11. Total current drawn from the sounder output cannot exceed 1 A.
Figure 11: Sounder (bell) Connections
4.3 Preliminary Testing
Once the control panel has been properly installed and wired:
1. Physically check the panel to ensure that there are no shorted or open
connections.
2. Power up the system.
All LEDs flash in sequence.
3. Verify that all LEDs were lit.
After programming the system as explained in Chapter 5, perform the following preliminary tests:
1. Perform a walk test for each of the zones.
2. Verify that the corresponding LEDs are lit.
3. Arm/disarm the system to verify that the system behaves according to the
programmed settings.
4. Initiate a call to the call center or to a private phone to test
communication.
Page 24
Programming
24 AuraSys™ L-2 and L-2K Installation Manual
5. Programming
The AuraSys L-2 can only be programmed using the AuraSys Lite Remote Programmer PC software.
There are two ways to connect the unit to a PC:
Directly using Rosslare’s MD-62 TTL to an RS-232 converter Remotely via the telephone line
You can also update the unit’s firmware using the AuraSys Lite Remote Programmer PC software with a direct connection using HyperTerminal.
5.1 Connections
To connect the AuraSys L-2 panel to the PC directly:
1. Using the Rosslare's MD-62 TTL to RS-232 converter, connect the MD-62
to the L-2/2K’s PC serial port.
Figure 12: Rosslare's MD-62 TTL to RS-232 Converter
If your computer does not have a serial port, use Rosslare’s MD-C24 USB to RS­232 converter.
2. Connect the RS-232 connector to the PC.
3. Ensure that the red wire in the cable’s 10-pin connector is connected to
Pin Number 1 on the PCB male connector.
4. Run the AuraSys Lite Remote Programmer PC software.
To connect the AuraSys L-2 panel to the PC remotely:
1. Connect the L-2/2k to the phone line using the RJ-11 cable.
2. Run the AuraSys Lite Remote Programmer PC software.
3. Ensure that the unit’s phone number is assigned in the application.
4. Ensure the computer running AR-P02 has a modem connection.
5.2 Programming Options
Refer to the AuraSys Lite Software Manual for detailed instructions on connecting to the panel and other available options.
Page 25
Battery Load Capacity
AuraSys™ L-2 and L-2K Installation Manual 25
A. Battery Load Capacity
Table 5: Battery Load Capacity
Panel Load Capacity BT-05 (800mAh) BT-16 (2 Ah)
Standby Current
Maximum Current
Standby Current
Maximum Current
L-2 Low 1 x PIRs 10 Hours 3.2 Hours 25 Hours 8.0 Hours L-2K Low 1 x PIRs 10 Hours 3.2 Hours 25 Hours 8.0 Hours
L-2 Full 2 x PIRs 8.8 Hours 3.1 Hours 22.2 Hours 7.8 Hours L-2K Full 2 x PIRs 8.8 Hours 3.1 Hours 22.2 Hours 7.8 Hours
Page 26
Expansions and Accessories
26 AuraSys™ L-2 and L-2K Installation Manual
B. Expansions and Accessories
B.1 MD-31 (RJ-31X Jack)
Even though the RJ31X jack has additional connections, typically only four wires are used; two for connecting to the outside phone line (T and R), and two for connecting to the inside phone lines (T1 and R1).
The MD-31 has eight screw terminals inside the housing. This makes it easy to connect the outside and inside lines.
To connect the MD-31:
1. Connect the lines as shown in Figure 13 and Figure 14.
The outside and inside lines can come into the jack from within the wall behind the jack, or into either, or both, sides of the jack.
Figure 13: MD-31 Dimensions
Figure 14: MD-31 Internal Wiring
Out to internal Phone Line – Ring Out to internal Phone Line – Tip From Phone Company – Ring From Phone Company – Tip
Page 27
Expansions and Accessories
AuraSys™ L-2 and L-2K Installation Manual 27
Color coding in the Figure 15 may vary based on the installer’s wiring; however, these are the standard color coding based on a typical installation.
When connected as shown (and nothing is plugged into the jack), the internal phones should work.
2. Replace the cover on the jack.
The unit can now be connected to the security system.
Figure 15: MD-31 to Alarm Panel Wiring
3. Connect the 50-cm cord to the alarm panel:
Yellow to "R" or "Ring" contact (Ring, from phone company) Green to "T" or "Tip" contact (Tip, from phone company) Brown to "R1" contact (Ring, To inside phones) White to "T1" contact (Tip, to inside phones)
4. Plug the 50-cm cord into the MD-31 and test communication.
B.2 SA-59 GSM Communicator
The SA-59 is a universal GSM reporting unit and communicator. When it is connected to an alarm panel, the SA-59 operates as a GSM backup unit to the PSTN line, enabling incoming and outgoing calls to be redirected to the GSM network if the PSTN line fails. Since the SA-59 simulates a telephone line, it makes no difference whether the device to which it is connected is a GSM or a land line.
The built-in SA-59 GSM module connects via the PSTN line to check for phone communication type availability. If there is no PSTN line, the SA-59 automatically switches the call from PSTN line to GSM.
When the SA-59 is connected to a telephone line (Line IN), the SA-59 tunnels the device to a land line to make a call. If the land line is cut or not
Page 28
Expansions and Accessories
28 AuraSys™ L-2 and L-2K Installation Manual
functioning, all communications go via the GSM network without the need for any special additional settings.
If the SA-59 is not connected to a land line, all communications take place via the GSM network.
Figure 16. Universal GSM Communicator
Page 29
Reporting Codes
AuraSys™ L-2 and L-2K Installation Manual 29
C. Reporting Codes
Table 6, Table 7, and Table 8 provide a listing of the Contact ID (CID) codes used to communicate with the CMS.
Table 6: Event Codes: Contact ID and SIA - Burglary and Fire
Burglary and Fire Event/Restore
Description CID Description CID
Medical Alarm (Restore) R100 Shorted (Event) E142
Emergency Alarm (Event) E101 Wired Tamper (Event) E144
Fire (Event) E110 Wired Tamper (Restore) R144
Fire (Restore) R110 Any Zone Trouble (Event) E380
RF Panic (Event) E120 Any Zone Trouble (Restore) R380
Alarm – 24-hour Silent (Event) E122 RF Supervisor (Event) E381
Alarm – 24-hour Silent (Restore) R122 RF Supervisor (Restore) R381
Burglary (Event) E130 RF Tamper (Event) E383
Burglary (Restore) R130 RF Tamper (Restore) R383
Alarm – 24-hour Audible (Event) E133 RF Low battery (Event) E384
Alarm – 24-hour Audible (Restore)
R133 RF Low battery (Restore) R384
Open (Event) E141
Table 7: Event Codes: Contact ID and SIA - Arming Events
Arm and Disarm Events
Description CID Description CID
Duress E121 Key Switch Disarm E409
Disarm E401 Key Switch Arm Away R409
Arm Away R401 Forced Arm Away R423
Alarm Cancel E406
Table 8: Event Codes: Contact ID and SIA - System Events
System Events
Description CID
Panel Remote Tamper (Event) E137
Panel Remote Tamper (Restore) R137
Panel Trouble E300
Page 30
Reporting Codes
30 AuraSys™ L-2 and L-2K Installation Manual
System Events
Description CID
Panel AC Fail (Event) E301
Panel AC Fail (Restore) R301
Panel Low battery (Event) E302
Panel Low battery (Restore) R302
Aux Bell Over (Event) E312
Aux Bell Over (Restore) R312
REM Module Missing (Event) E330
REM Module Missing (Restore) R330
RF Jamming (Event) E344
RF Jamming (Restore) R344
Communication Fail (Event) E354
Communication Fail (Restore) R354
Swinger Over E377
Zone Bypass E570
Zone Un-bypass R570
Fire Zone Bypass E571
Fire Zone Un-bypass R571
CMS Test E602
Listen In Start E606
Inaccurate Time (Event) E626
Inaccurate Time (Restore) R626
Page 31
Useful Information and Tables
AuraSys™ L-2 and L-2K Installation Manual 31
D. Useful Information and Tables
There are several programming worksheets in this chapter so that the installer can keep a record of what has been done during the initial programming.
D.1 Customer Information
Customer: __________________________________________________________ Address: ___________________________________________________________ ___________________________________________________________________ ___________________________________________________________________ Telephone: ______________________ Installation Date: ____________________
D.2 Installer Information
Name: _____________________________________________________________ Address: ___________________________________________________________ ___________________________________________________________________ ___________________________________________________________________ Telephone: ______________________ Installer’s Code: ____________________
D.3 Device Information
Module Name Description Location
Page 32
Useful Information and Tables
32 AuraSys™ L-2 and L-2K Installation Manual
D.4 Zone Worksheet
Print out this Zone Worksheet and use it to plan programming values for each zone.
Zone Input
Type
Partition PGM#
Crossing
Paired Zone
Response time (in100 ms)
Chime Alarm
Verification
PGM
Activation
on Zone Violation
No-
Activity
Monitoring
Zone Crossing/ Walkthrough
01 02
03 04
Page 33
Limited Warranty
AuraSys™ L-2 and L-2K Installation Manual 33
E. Limited Warranty
The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www.rosslaresecurity.com.
Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them.
Page 34
AuraSys™ L-2
0706-0960326+01
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 support.apac@rosslaresecurity.com
United States and Canada
Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd. Rosh HaAyin, Israel Tel: +972 3 938-6838 Fax: +972 3 938-6830 support.eu@rosslaresecurity.com