This manual and the information contained herein are proprietary to
ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or
subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers
have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by
any means, electronic or mechanical, for any purpose, without the express
written permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or
other intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT
IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT
LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE,
REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT
EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any
third party any license to these patents, trademarks, copyrights or other
intellectual property rights, except as expressly provided in any written
agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any
time, without being obliged to announce such revisions or changes
beforehand or after the fact.
Table 3: Quick Reference Guide for Auxiliary Mode Setting ............................36
AC-Q4x Series Installation and Programming Manual vii
Introduction
Notice and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and
efficient installation and usage of the system and/or product, and/or
software described herein.
EFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM,THE I NSTALLER AND THE USER
B
MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND
OPERATING PROCEDURES
The system must not be used for purposes other than those for which it
was designed.
The use of the software associated with the system and/or product, if
applicable, is subject to the terms of the license provided as part of the
purchase documents.
ROSSLARE exclusive warranty and liability is limited to the warranty and
liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with
the maximum number of functions, including future options. Therefore,
not all functions described in this manual may be available in the
specific system and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively
maintain the system, relieves the manufacturer (and seller) from all or
any responsibility for consequent noncompliance, damage, or injury.
The text, images and graphics contained in the manual are for the
purpose of illustration and reference only.
All data contained herein subject to change without prior notice.
In no event shall manufacturer be liable for any special, direct, indirect,
incidental, consequential, exemplary or punitive damages (including,
without limitation, any and all damages from business interruption, loss
of profits or revenue, cost of capital or loss of use of any property or
capital or injury).
All wiring diagrams are intended for reference only, the photograph or
graphic of the PCB(s) are intended for clearer illustration and
understanding of the product and may differ from the actual PCB(s).
.
8 AC-Q4x Series Installation and Programming Manual
Introduction
AC-Q41HP
2 A Standard
AC-Q44
2 A Piezoelectric
1. Introduction
The AC-Q4x series are vandal resistant standalone controllers. All
the units are water resistant and suitable for indoor or outdoor
mounting. The unit(s) accepts up to 500 users and allows entry via
a personal identification number (PIN) and/or by presenting a
proximity card.
1.1 Controller Types
The different types of control units described in this manual are:
Type 41 – PIN only
Type 42 – PIN and proximity card
Type 44 – PIN and proximity card, with piezoelectric contacts
Heater Relay
Current
AC-Q41HB
AC-Q41SB
AC-Q42HB
AC-Q42HP
AC-Q42SB
2 A
2 A
2 A
2 A
2 A
Backlight Keypad
Type
Standard
Standard
Standard
Standard
Standard
Proximity
AC-Q4x Series Installation and Programming Manual 9
Introduction
1.2 Box Content
Before beginning, verify that all of the following is in the box. If
anything is missing please report the discrepancy to your nearest
Rosslare Office.
The following ancillary equipment may be required to complete
your installation:
Electric Lock Strike Mechanism – Fail safe (power to lock) or
fail secure (power to open)
Power supply with backup battery – 12 to 24 VDC (from a
regulated power supply) or 16 to 24 VAC (from a transformer)
Request-to-Exit (REX) button (optional) – Normally open type;
switch is closed when pressed
BL-D40 external sounder (optional) – Provides siren, bell, and
chime
Magnetic contact (optional) – Installed for door monitor
capabilities
10 AC-Q4x Series Installation and Programming Manual
Introduction
1.4 Front Panel Description
Controls and indicators of all controller versions are identical
(excluding the antenna, which is unique to Q42 and Q44) (Figure 1).
Figure 1: Front Panel
AC-Q4x Series Installation and Programming Manual 11
Installation
2. Installation
Installation of an RFID reader adjacent to metallic surfaces
might alter the reader’s specifications. To diminish this
interference, use a plastic spacer when mounting the reader.
2.1 Mounting
Prior to starting, select the location where the controller unit is to be
mounted.
To mount the controller:
1. Peel off the back of the self-adhesive mounting label template
and place it on the required mounting location.
2. At the bottom of the unit’s case, remove the screw.
3. Remove the cover by gently sliding it up and then pulling it
apart. Once you remove the cover, you will see the screw holes
for mounting.
4. Depending on the type of installation, gang box or panel mount,
drill the respective holes in the rear cover (see Figure 2 for
details). For gang box mounting, drill two holes marked “A”. For
flat panel mount, drill four holes marked “B”.
Figure 2: Drilling Holes Identification
The central hole, marked “C” is for routing the wiring to the
controller.
12 AC-Q4x Series Installation and Programming Manual
Installation
5. Drill an additional 10-mm (7/16”) hole for the cable. When
installing the reader on a metallic surface, cover the inside of
the hole with a grommet or electrical tape.
6. Insert the unit’s cable wire into the cable hole and wire the unit
as described in Section 2.2.
7. Screw the back plate into the surface. Ensure the screws are
the size specified on the installation template.
The unit can also be mounted using strong epoxy glue. After
application, firmly hold the unit in place until the glue dries.
8. Carefully re-attach the front cover of the unit.
9. Secure the front cover by using the supplied security Torx
screw. A Torx security screw tool is provided to tighten the
security Torx screw.
2.2 Wiring
The controllers are provided either with a pre-wired cable or with a
screw-type terminal block:
Pre-wired Cabling Models Terminal Block Models
AC-Q41SB AC-Q41HB/HP
AC-Q42SB AC-Q42HB
AC-Q44
AC-Q4x Series Installation and Programming Manual 13
Installation
Blue
Aux: Com
2.2.1 Pre-wired Models
These units are supplied with a 10-conductor 60-cm (24-in.) pigtail
(24-AWG cable) with exposed wires coated with solder.
To wire the controller:
1. Select the appropriate connections according to Table 1.
Table 1: Wire Color Guide
Color Description
Red V input
Black Ground
Green REX/BL
White In/Monitor
Purple Lock: Com
Gray Lock: N.O.
Brown Lock: N.C.
Yellow Aux: N.O.
Orange Aux: N.C.
2. Prepare the secured power supply’s cable by cutting the cable
jacket back 3.2 cm (1¼”) and strip the wire 1.3 cm (½”).
3. Splice the controller pigtail wires to the corresponding ancillary
devices and insulate each connection, including unused wires.
Refer to the wiring diagrams, depending on the desired
application:
Wiring the Lock Strike Relay & REX (Figure 3)
Wiring for Auxiliary Input & Output (Figure 4)
Wiring for the BL-D40 External Sounder (Figure 5)
14 AC-Q4x Series Installation and Programming Manual
Installation
Figure 3: Pre-Wired Connection for Lock Strike Relay & REX
AC-Q4x Series Installation and Programming Manual 15
Installation
Figure 4: Pre-Wired Connection for Auxiliary Input & Output
16 AC-Q4x Series Installation and Programming Manual
Installation
Figure 5: Pre-Wired Connection for the BL-D40 External Sound er
AC-Q4x Series Installation and Programming Manual 17
Installation
2.2.2 Terminal Block Models
These controllers come with removable terminal blocks that are
pushed on pins on the motherboard of the controllers.
To wire the terminal blocks:
1. Route the wires or cable through the large hole in the back
cover See Figure 6. Connect the terminal blocks as shown.
2. Wire the cabling according to the following diagrams.
3. Wiring the Lock Strike Relay & REX (Figure 7)
4. Wiring for Auxiliary Input & Output (Figure 8)
5. Wiring for the BL-D40 External Sounder (Figure 9)
Figure 6: Connections to Terminal Blocks
18 AC-Q4x Series Installation and Programming Manual