Rosslare AC-A41, AC-A42 Installation And Programming Manual

Page 1
2013
June
AC-A4x Family
Indoor Standalone Controller
Installation and Programming Manual
AC-A41 AC-A42
Page 2
Copyright © 2013 by Rosslare. All rights reserved.
This manual and the information contained herein are proprietary to REL, RSP Inc. and/or their related companies and/or subsidiaries’ (hereafter:”ROSSLARE”). Only ROSSLARE and its customers have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
Page 3
Table of Contents
AC-A4x Installation and Programming Manual iii
Table of Contents
1. Introduction ................................................................ 8
1.1 Reader/Controller Types........................................................... 8
1.2 Key Features ........................................................................... 8
1.3 Equipment .............................................................................. 9
1.4 Additional Equipment .............................................................. 9
2. Technical Specifications ............................................ 10
3. Installation ................................................................ 11
3.1 Mounting ............................................................................. 11
3.2 Wiring .................................................................................. 13
4. Normal, Secure, and Master Users ............................ 15
5. Modes of Operation .................................................. 16
6. Changing the Modes of Operation ........................... 17
6.1 Changing from Normal to Secure Mode ................................. 17
6.2 Changing from Secure to Normal Mode ................................. 17
6.3 Changing from Normal to Bypass Mode ................................. 18
6.4 Changing from Bypass Mode to Normal Mode ....................... 18
7. Auxiliary Input and Output ...................................... 19
8. REX Button ................................................................ 20
9. Case and Back Tamper .............................................. 21
10. BL-D40 External Sounder .......................................... 22
11. Programming the AC-A4x ......................................... 23
11.1 Entering Programming Mode ................................................. 24
11.2 Exiting Programming Mode ................................................... 24
Page 4
Table of Contents
iv AC-A4x Installation and Programming Manual
11.3 Changing the Open Code ...................................................... 25
11.4 Changing the Auxiliary Code ................................................. 25
11.5 Changing the Programming Code .......................................... 26
11.6 Changing the Normal/Secure Code ........................................ 27
11.7 Changing the Normal/Bypass Code and Door Chime Settings .. 27
11.8 Defining the Auxiliary Input and Output ................................. 28
11.9 Setting Fail Safe/Secure Operation, Tamper Siren Time, and Lock
Strike Release Time................................................................ 31
11.10 Enrolling Primary and Secondary Codes .................................. 32
11.10.1 Primary Codes............................................................................... 32
11.10.2 Secondary Codes .......................................................................... 32
11.10.3 Enrolling Primary and Secondary Codes ........................................ 32
11.10.4 Enrolling Primary and Secondary Codes Using the Standard Method
..................................................................................................... 33
11.10.5 Enrolling Secondary Codes Using the Code Search Method .......... 34
11.11 Deleting Primary and Secondary Codes ................................... 35
11.11.1 Deleting Primary and Secondary Codes Using the Standard Method
..................................................................................................... 35
11.11.2 Deleting Primary and Secondary Codes Using the Code Search
Method ........................................................................................ 36
11.12 Lock Strike Relay and Auxiliary Relay Code Assignment ........... 37
11.12.1 Lock Strike Relay and Auxiliary Relay Code Assignment using
Standard Method ......................................................................... 38
11.12.2 Lock Strike Relay and Auxiliary Relay Code Assignment using Search
Method ........................................................................................ 38
11.13 Return to Factory Default Settings .......................................... 39
11.14 Replacing a Lost Programming Code ...................................... 40
11.15 Replacing a Lost Normal/Secure Code .................................... 40
A. Limited Warranty ...................................................... 41
Page 5
List of Figures
AC-A4x Installation and Programming Manual v
List of Figures
Figure 1: AC-A4x Controller – Labeled Diagram .............................................. 11
Figure 2: AC-A4x Controller – Mounting Holes and Terminal Blocks ............... 12
Figure 3: Wiring the Lock Strike Relay and REX ................................................ 13
Figure 4: Wiring the Auxiliary Input and Output .............................................. 13
Figure 5: Wiring the BL-D40 External Sounder ................................................. 14
Page 6
List of Tables
vi AC-A4x Installation and Programming Manual
List of Tables
Table 1: Programming Menus.......................................................................... 23
Table 2: Quick Reference Guide for Auxiliary Mode Setting ............................. 30
Page 7
Notice and Disclaimer
AC-A4x Installation and Programming Manual vii
Notice and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein.
B
EFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND THE
USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY REQUIREMENTS AND OPERATING PROCEDURES
.
The system must not be used for purposes other than those for which it
was designed.
The use of the software associated with the system and/or product, if
applicable, is subject to the terms of the license provided as part of the purchase documents.
ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or
subsidiaries’ (hereafter:"ROSSLARE") exclusive warranty and liability is limited to the warranty and liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with the
maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively
maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury.
The text, images and graphics contained in the manual are for the purpose
of illustration and reference only.
In no event shall manufacturer be liable for any special, direct, indirect,
incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury).
All graphics in this manual are for reference only, some deviation between
the image(s) and the actual product may occur.
All wiring diagrams are intended for reference only, the photograph or
graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s).
Page 8
Introduction
8 AC-A4x Installation and Programming Manual
1. Introduction
The AC-A4x access control units are indoor standalone controllers. The units accept up to 500 users and allow entry via a personal identification number (PIN) and/or by presenting a proximity card
1.1 Reader/Controller Types
The two types of units described in this manual are:
Keypad Type PIN Proximity
AC-A41
Standard
AC-A42
Standard
1.2 Key Features
Built in keypad for PIN code entry Built-in proximity card reader (125 KHz ASK modulation) (AC-A42
only)
Auxiliary Input and Auxiliary Output Eight Auxiliary Modes including Door Ajar, Forced Door, Shunt,
Door Monitor, and Normal/Secure
Internal buzzer Comes with security screw and security screw tool Two status/programming interface LEDs Three user levels (Normal User, Secure User, Master User) Three modes of operation (Normal Mode, Bypass Mode, Secure
Mode)
"Code Search" feature simplifies maintaining user codes Input for REX button Lock Strike Electronic Relay with built-in suppressor protection Comes with mounting template for easier installation Built-in case and back tamper
Page 9
Introduction
AC-A4x Installation and Programming Manual 9
Bell, chime, siren, and strobe features available with BL-D40 Bell, chime, siren, battery backup, tamper output (open collector
20 mA) features available with PS-X41 (output power 1.2 A) and PS-X42 (output power 1.8 A)
Programmable siren time Programmable Lock Strike Release Time
1.3 Equipment
The following equipment is provided in every AC-A4x package:
AC-A4x Access Control Unit Installation kit Installation and operating instructions
1.4 Additional Equipment
The following additional equipment is required:
Electric Lock Strike Mechanism – Fail Safe (Power to Lock) or Fail
Secure (Power to Open)
Power supply with backup battery – 12 to 16 VDC (from a
regulated power supply)
Request to Exit (REX) button – Normally Open Type; switch is
closed when pressed.
BL-D40 External Sounder (optional) – Provides siren, bell, and
chime functions to AC-A4x
Other Rosslare accessories can be found at Rosslare's website:
http://www.rosslaresecurity.com
Page 10
Technical Specifications
10 AC-A4x Installation and Programming Manual
2. Technical Specifications
Electrical Characteristics
Operating Voltage Range
12–16 VDC From a regulated power supply
Input Current
Standby: 40 mA (excluding attached devices)
Max: 100 mA (excluding attached devices)
Relay Outputs
Lock Strike Relay – 3.5 A with built-
in suppressor protection
Auxiliary Relay – Form C, 1 A
Inputs
REX: N.O., Dry Contact Auxiliary Input (In/Monitor):
Monitor mode: N.C., Dry
Contact
Input Mode: N.O., Dry Contact
LEDs
Two tri-colored LEDs
Built-In Proximity Reader (AC­A42)
Read Range:* 3.5 in. (90 mm) Modulation: ASK at 125 kHz
Compatible cards: All 26-Bit EM
cards
Environmental Characteristics
Operating Temperature
-25°F to 145°F (-32°C to 63°C)
Operating Humidity
0 to 95% (non-condensing)
Mechanical Characteristics
Dimensions Length x Width x Depth
4.80 in. x 2.95 in. x 0.94 in. (122 x 75 x 24 mm)
Weight
0.3 lb (140 g)
* Measured using Rosslare Proximity Card (AT-11/12) or equivalent.
Range also depends on electrical environment and proximity to metal
Page 11
Installation
AC-A4x Installation and Programming Manual 11
3. Installation
3.1 Mounting
Before starting, select the location to mount the AC-A4x controller. This location should be at shoulder height and on the same side as the door handle.
The controller is designed to be easily mounted onto a US Gang Box.
1. Remove the Bezel Screw from the unit (see Figure 1).
Figure 1: AC-A4x Controller – Labeled Diagram
2. Screw the controller onto a US Gang Box through the two mounting holes provided (see Figure 2).
Page 12
Installation
12 AC-A4x Installation and Programming Manual
Figure 2: AC-A4x Controller – Mounting Holes and Terminal Blocks
3. Pass the wires through the exit/entry holes and attach them to the controller's terminal blocks, as shown in Figure 3 and Figure
5).
4. Replace the controller’s bezel and replace the factory default screw with the security screw that is provided in the installation kit. A security screw tool is also provided in the installation kit.
AC-A4x
Page 13
Installation
AC-A4x Installation and Programming Manual 13
3.2 Wiring
Three typical wiring diagrams are shown in Figure 3 through Figure 5.
Figure 3: Wiring the Lock Strike Relay and REX
Figure 4: Wiring the Auxiliary Input and Output
AC-A4x
AC-A4x
Page 14
Installation
14 AC-A4x Installation and Programming Manual
Figure 5: Wiring the BL-D40 External Sounder
For other wiring diagram examples, refer to the support section of the Rosslare website:
http://www.rosslaresecurity.com/.
AC-A4x
Page 15
Normal, Secure, and Master Users
AC-A4x Installation and Programming Manual 15
4. Normal, Secure, and Master Users
The AC-A4x series accept up to 500 users and provide entry via the use of proximity cards and/or PIN codes. Each user is provided with two code memory slots: Memory Slot 1 (Primary code) and Memory Slot 2 (Secondary code). For the AC-A42, the two memory slots can be programmed as proximity cards, PIN codes, or a combination of both proximity cards and PIN codes.
The way that the two memory slots are programmed determines a user's access level and also determines the way that the units grant access in their three modes of operation (Chapter 5).
There are three user levels:
Normal User – A Normal User only has a Primary code and is only
granted access when the AC-A4x is in Normal or Bypass mode.
Secure User – A Secure User must have a Primary and Secondary
codes programmed; the two codes cannot be the same. The Secure User can gain access when the AC-A4x is in any of its three modes of operation. In Normal mode, the Secure User must use a Primary code to gain entry. In Secure mode, the Secure User must present both a Primary and Secondary code to gain entry.
Master User – A Master User must have both Primary and
Secondary codes programmed with the same Proximity card or PIN code. The Master User can gain access during any mode of operation by presenting the Proximity card (AC-A42 only) or entering the PIN code. (The Master User is convenient, but is less secure than a Secure User.)
Page 16
Modes of Operation
16 AC-A4x Installation and Programming Manual
5. Modes of Operation
In the Operation chapter, “code” refers to a PIN code or proximity card depending on the unit you have.
Memory slots can be a proximity card or PIN code depending on the unit you have.
The AC-A4x series have three modes of operation:
Normal mode – Mode LED is green
Normal Mode is the default mode. In Normal mode, the door is locked until a Primary code is presented to the controller. Special codes such as “Open Code” and “Auxiliary Code” are active in Normal mode (see Sections 11.3 and 11.4).
Bypass mode – Mode LED is orange
In Bypass mode, access to the premises is dependent on whether the controller's Lock Strike Relay is programmed for Fail Safe Operation or for Fail Secure Operation.
When the Lock Strike Relay is programmed for Fail Secure Operation, the door is locked until the door bell button is pressed. When the Lock Strike Relay is programmed for Fail Safe Operation, the door is constantly unlocked.
Secure mode – Mode LED is red
Only Secure and Master Users can access the premises during the Secure Mode. A Secure User must enter a Primary and a Secondary code to gain entry. After entering the Primary code, the Door LED flashes green for 10 seconds, during which time the Secondary code must be entered. A Master User only needs to present the Proximity card or enter the PIN code once to gain entry.
Mode
Door
Green
Mode
Door
Orange
Mode
Door
Red
Page 17
Changing the Modes of Operation
AC-A4x Installation and Programming Manual 17
6. Changing the Modes of Operation
6.1 Changing from Normal to Secure Mode
The default factory setting for the Normal/Secure code is 3838.
To change from Normal to Secure mode:
1. Enter the 4-digit Normal/Secure code.
The Mode LED flashes red.
2. Press # to confirm the mode change.
The Mode LED turns red.
The Auxiliary Input can also be used to switch the Mode of Operation from Normal to Secure and vice versa (see Section 11.8).
6.2 Changing from Secure to Normal Mode
The default factory setting for the Normal/Secure code is 3838.
To change from Secure to Normal mode:
1. Enter the 4-digit Normal/Secure code.
The Mode LED flashes green.
2. Press # to confirm the mode change.
The Mode LED turns green.
The Auxiliary Input can also be used to switch the Mode of Operation from Secure to Normal and vice versa (see Section 11.8).
Mode
Door
Green
Mode
Door
Red
Mode
Door
Red
Mode
Door
Green
Mode
Door
Green
Mode
Door
Green
Page 18
Changing the Modes of Operation
18 AC-A4x Installation and Programming Manual
6.3 Changing from Normal to Bypass Mode
See Section 11.7 to create/modify the Normal/Bypass code.
To change from Normal to Bypass mode:
1. Enter the 4-digit Normal/Bypass code.
The Mode LED flashes orange.
2. Press # to confirm the mode change.
The Mode LED turns orange.
6.4 Changing from Bypass Mode to Normal Mode
See Section 11.7 to create/modify the Normal/Bypass code.
To change from Bypass to Normal mode:
1. Enter the 4-digit Normal/Bypass code.
The Mode LED flashes green.
2. Press # to confirm the mode change.
The Mode LED turns green.
Mode
Door
Green
Mode
Door
Orange
Mode
Door
Orange
Mode
Door
Orange
Mode
Door
Green
Mode
Door
Green
Page 19
Auxiliary Input and Output
AC-A4x Installation and Programming Manual 19
7. Auxiliary Input and Output
For optimum usability in different applications, the controller’s auxiliary input and output can be configured in 8 different modes of operation (see Section 11.8).
Page 20
REX Button
20 AC-A4x Installation and Programming Manual
8. REX Button
The REX button is used to open the door without the use of proximity card or PIN code, and must be located inside the premises to be secured. It is usually located in a convenient location, such as inside the door or at a receptionist's desk. The function of the REX button depends on whether the Lock Strike Relay is programmed for Fail Safe Operation or for Fail Secure Operation. The door chime in the BL-D40 does not sound when the REX button is used to open the door.
Fail Secure Operation: From the moment the REX button is
pressed, the door remains unlocked until the Lock Strike Release Time passes. After this time, the door is locked even if the REX Button is not released.
Fail Safe Operation: From the moment the REX Button is pressed,
the door remains unlocked until the REX Button is released and the Lock Strike Release Time passes. In this case, the Lock Strike Relay only begins its countdown once the REX Button is released.
Page 21
Case and Back Tamper
AC-A4x Installation and Programming Manual 21
9. Case and Back Tamper
If the case of the controller is opened or the controller is removed from the wall, a tamper event is triggered and a coded tamper signal is sent to a BL-D40, PS-X41 Series, or PS-X42 Series Power Supply, or to another compatible device.
If the BL-D40 External Sounder, PS-x41 Series, or PS-x42 Series Power Supplies receive a tamper event signal, it activates a siren, and if available, a strobe light. The siren time can be easily programmed in the AC-A4x unit from zero to nine minutes.
You can clear a tamper event by entering a valid User or Open code to open the Lock Strike Output in the current mode of operation. For example, while in Secure mode, you cannot use the Open code to clear the tamper event, because the Open code does not work in Secure mode. However, you can apply a Master code or Secure code to clear the tamper event in Secure mode.
Page 22
BL-D40 External Sounder
22 AC-A4x Installation and Programming Manual
10. BL-D40 External Sounder
The BL-D40 External Sounder is compatible with the AC-x31, AC-x32, AC-x41, and AC-x42 series of standalone controllers. (For a more up­to-date list of compatible products, check the Rosslare website at
www.rosslaresecurity.com.) It is designed to operate indoors and is
installed within the premises to be secured. The sounder can be powered by a 16 VAC or 12 to 24 VDC power supply.
The BL-D40 is capable of emitting four different types of alerts, both audible and visual: Bell, Door Chime, Siren, and Strobe Light.
The bell always sounds when the controller's doorbell button is
pressed.
The door chime can be programmed to sound whenever the
controller unlocks the door (the door chime does not sound when the REX button is used to open the door).
The siren can be programmed to sound when the case of the
controller is opened or when the controller is removed from the wall. The controller can also program the length of the siren in the BL-D40.
The controller communicates with the BL-D40 using a coded proprietary Rosslare communications protocol. This provides a more secure link between the controller and the BL-D40. If the BLD40 receives any unrecognized codes on its communication line, or communication between the controller and the BL-D40 are severed, the strobe flashes repeatedly until the communication problem is resolved.
Page 23
Programming the AC-A4x
AC-A4x Installation and Programming Manual 23
11. Programming the AC-A4x
You can program the AC-A4x solely via the unit's keypad-driven programming menu system. To reach the programming menu system, first place the unit into Programming mode (see Section 11.1).
During the AC-A4x manufacturing process, certain codes and settings are pre-programmed. These settings are called the default factory settings.
Table 1 shows the names of all the AC-A4x menus. It also shows all the unit’s default factory codes and settings.
Table 1: Programming Menus
Menu Number Menu Description Factory Settings
1 Change Open Code 1 2580
2 Change Auxiliary Code 0852
3 Change Program Code 1234
4 Change Normal/Secure Code 3838
5 Change Normal/Bypass Code N/A
6 Change Door Release Time 0004
Define Auxiliary Inputs/Outputs 2004
7 Enroll proximity cards, PIN code
or both
8 Delete Proximity cards or PIN
code
9 Code Assignment with
Strike/Auxiliary
0 Return to default factory settings
A complete description and instructions for each of the above menu items is detailed in the following subsections.
Page 24
Programming the AC-A4x
24 AC-A4x Installation and Programming Manual
11.1 Entering Programming Mode
To enter Programming mode:
1. Press # for two seconds.
The Mode LED turns off and the Door LED turns red.
2. Enter your 4-digit Programming code.
If the Programming code is valid, the door LED turns green and the unit goes into Programming mode.
The unit must be in Normal mode to enter the Programming mode.
The factory default Programming code is 1234. If a Programming code is not entered within five seconds, the
unit returns to Normal mode.
11.2 Exiting Programming Mode
To exit Programming mode:
1. Press # for two seconds.
Three beeps are emitted. The Door LED turns off. The Mode LED turns green, indicating that
the unit has returned to Normal mode.
Wrong entries may reset the controller back to Normal mode. While in Programming mode, if no key is pressed for one
minute, the unit exits Programming mode and returns to Normal mode.
In certain Programming modes, a quick press on # may also return the system to Normal mode.
Mode
Door
Red
Mode
Door
Green
Mode
Door
Green
Page 25
Programming the AC-A4x
AC-A4x Installation and Programming Manual 25
11.3 Changing the Open Code
The Open code is mainly used as a method to quickly test the Lock Strike Relay during installation.
The default factory setting for Open code is 2580. When the first user is added to the controller, the default Open code
is automatically deleted, and is ready for a new Open code to be re­entered.
To change the Open code:
1. Enter Programming mode.
2. Press 1 to enter Menu 1.
The Mode LED turns red.
3. Enter the new 4-digit code that you want
to set as the Open code.
The system returns to Normal mode:
The Door LED turns off. The Mode LED turns green.
The Open code does not function in Secure mode. Wrong entries return the controller to Normal mode. Code 0000 erases and deactivates the Open code.
11.4 Changing the Auxiliary Code
The Auxiliary code is mainly used as a method to quickly test the Lock Strike Relay during installation.
The default factory setting for the Auxiliary code is 0852. When the first user is added to the controller, the default Auxiliary
code is automatically deleted, and is ready for a new Auxiliary code to be re-entered.
Mode
Door
Green
Mode
Door
Red
Green
Mode
Door
Green
Page 26
Programming the AC-A4x
26 AC-A4x Installation and Programming Manual
To change the Auxiliary code:
1. Enter Programming mode.
2. Press 2 to enter Menu 2.
The Mode LED turns orange.
3. Enter the new 4-digit code that you want
to set as the Auxiliary code.
The system returns to Normal mode:
Three beeps are emitted. The Door LED turns off. The Mode LED turns green.
The Auxiliary code does not function in Secure mode. Auxiliary code only works when the Auxiliary mode is 1 or 2. Code 0000 erases and deactivates the Auxiliary code.
11.5 Changing the Programming Code
To change the Programming code:
1. Enter Programming mode.
2. Press 3 to enter Menu 3.
The Mode LED turns green.
3. Enter the new 4-digit code that you want
to set as the Programming code.
The system returns to Normal mode:
Three beeps are emitted. The Door LED turns off. The Mode LED turns green.
Mode
Door
Green
Green
Mode
Door
Orange
Mode
Door
Green
Mode
Door
Green
Mode
Door
Green
Green
Mode
Door
Green
Page 27
Programming the AC-A4x
AC-A4x Installation and Programming Manual 27
The Programming code cannot be erased; code 0000 is invalid and does not erase the Programming code.
11.6 Changing the Normal/Secure Code
To change the Normal/Secure code:
1. Enter Programming mode.
2. Press 4 to enter Menu 4.
The Mode LED flashes red.
3. Enter the new 4-digit code that you want
to set as the Normal/Secure code.
The system returns to Normal mode:
Three beeps are emitted. The Door LED turns off. The Mode LED turns green.
When the Auxiliary Mode is 1, 2, 3, or 4, the Auxiliary Input takes priority over the Normal/Secure code.
11.7 Changing the Normal/Bypass Code and Door Chime Settings
The Normal/Bypass code is also used to turn the door chime off and on.
To change the Normal/Bypass code and Door Chime Settings:
1. Enter Programming mode.
2. Press 5 to enter Menu 5.
The Mode LED flashes orange.
Mode
Door
Green
Mode
Door
Red
Green
Mode
Door
Green
Mode
Door
Green
Mode
Door
Orange
Green
Page 28
Programming the AC-A4x
28 AC-A4x Installation and Programming Manual
3.
There are four different ways to program the Normal/Bypass code
and door chime:
Disable both Bypass code
and the door
chime. Enter the code 0000.
Disable Bypass code and enable the
door chime. Enter the code 0001.
Enable Bypass code and disable the
door chime. Enter any code ending with 0.
Enable Bypass code and enable the
door chime. Enter a code not ending with 0.
The system returns to Normal mode:
Three beeps are emitted. The Door LED turns off. The Mode LED turns green.
The door is only generated when the Lock Strike Relay is activated due to a valid code entry.
11.8 Defining the Auxiliary Input and Output
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
The Mode LED flashes green.
Mode
Door
Green
Mode
Door
Green
Mode
Door
Green
Green
Page 29
Programming the AC-A4x
AC-A4x Installation and Programming Manual 29
3. Construct a code using the following
instructions:
Auxiliary Mode Auxiliary Setting
Auxiliary Mode
In addition to the Lock Strike Relay and Lock Strike REX, the controller features an Auxiliary Output Relay and an Auxiliary Input. The Auxiliary mode defines the function of the Auxiliary Input and Output.
The Auxiliary mode also determines if the Auxiliary Output Relay is set for Fail Safe or Fail Secure Operation.
Auxiliary Settings
Each of the Auxiliary modes has a two-digit setting that affects how the Auxiliary mode functions.
The system returns to Normal mode. You hear three beeps. The Door LED turns off and the Mode LED
turns green.
Mode
Door
Green
Page 30
Programming the AC-A4x
30 AC-A4x Installation and Programming Manual
Table 2: Quick Reference Guide for Auxiliary Mode Setting
Aux. Mode Aux. Input
Function
Aux. Output Activated by
Aux. Relay Aux. Settings
(in seconds)
0 REX-2 Valid code or REX-2 N.O. 01 to 99 Aux. Relay
Release Time 00 Aux. Relay Toggles
1 Normal/Secure switch Valid code N.O. 01 to 99 Aux. Relay
Release Time 00 Aux. Relay Toggles
2 Normal/Secure switch Bell button N.O. 01 to 99 Aux. Relay
Release Time 00 Aux. Relay Toggles
3 Normal/Secure switch Tamper event N.C. 01 to 99 Aux. Relay
Release Time 00 Aux. Relay
activated by Tamper
4 Normal/Secure switch Direct shunt N.O.
00 to 99 Shunt time
5 Door Monitor Shunt N.C. 00 to 99 Maximum
shunt time
6 Door Monitor Forced door N.C. 00 to 99 Forced delay
7 Door Monitor Door ajar N.C.
00 to 99 Ajar delay
Page 31
Programming the AC-A4x
AC-A4x Installation and Programming Manual 31
11.9 Setting Fail Safe/Secure Operation, Tamper Siren Time, and Lock Strike Release Time
1. Enter Programming mode.
Press 6 to enter Menu 6.
The Mode LED flashes green.
2. Construct the 4-digit code using the
following instructions:
First Digit
For Fail Secure Operation, the first digit should be 0.
For Fail Safe Operation the first digit should be 1.
Second Digit
Tamper Siren time in minutes (1–9)
Third and Fourth Digits
Enter the number of seconds (from 1 to 99) that you want the Lock Strike to be released.
For example, 0512 means a Fail Secure Operation consisting of a 5-minute siren and a 12-second Lock Strike release time.
The system returns to Normal mode. You hear three beeps. The Door LED turns off and the Mode LED
turns green.
Mode
Door
Green
Mode
Door
Green
Green
Mode
Door
Green
Page 32
Programming the AC-A4x
32 AC-A4x Installation and Programming Manual
11.10 Enrolling Primary and Secondary Codes
11.10.1 Primary Codes
Primary codes can only be enrolled to an empty user slot,
meaning a slot where there is no existing Primary code.
Primary codes must be unique, meaning that one user's Primary
code cannot be the same as another user's Primary code.
Primary codes cannot be the same as any system codes, such as
the Normal/Secure code or Open code.
Users who hold a Primary code can gain entry only during Normal
mode.
11.10.2 Secondary Codes
Secondary codes can only be enrolled to a user slot that already
has a Primary code enrolled, but no Secondary code.
Secondary codes do not have to be unique, meaning that
multiple users can all hold the same Secondary code.
Secondary codes cannot be the same as any system codes, such
as the Normal/Secure code or Open code.
Users who hold Secondary codes can gain entry in any mode of
operation.
11.10.3 Enrolling Primary and Secondary Codes
There are two methods to enroll Primary and Secondary codes:
Standard Method
Mainly used when the user slot number for the user that you want to program is known. You can program both Primary and Secondary codes using the Standard method (see Section
11.10.4).
Code Search Method
Mainly used when enrolling a user's Secondary code and the user slot code is unknown. The Code Search method only works if a user’s Primary code is already enrolled but the Secondary code is not (see Section 11.10.5).
Page 33
Programming the AC-A4x
AC-A4x Installation and Programming Manual 33
11.10.4 Enrolling Primary and Secondary Codes Using the Standard Method
To enroll primary and secondary codes using the Standard method:
1. Enter Programming mode.
2. Press 7 to enter Menu 7.
The Door LED turns orange.
3. Perform one of the following:
a. Enter a 3-digit User Slot number
between 001 and 500 to indicate the user to whom you want to enroll a Primary or Secondary code. For example, the User Slot 003 represents User #3.
If the selected slot has no Primary code, the Mode LED flashes green, indicating that the controller is ready to accept a Primary code.
If the selected slot already has a Primary code but no Secondary code, the Mode LED flashes red, indicating that the controller is ready to accept a Secondary code.
If the selected slot already has a Primary and Secondary code
,
you hear a long beep and the controller returns to Normal mode.
Mode
Door
Green
Mode
Door
Orange
Mode
Door
Green
Green
Mode
Door
Red
Green
Page 34
Programming the AC-A4x
34 AC-A4x Installation and Programming Manual
b. Present a Proximity card (AC-A42) or enter the 4-digit PIN
that you want to assign as the Primary or Secondary code for this slot number.
If the Proximity card or PIN entered is valid, the Mode LED stops flashing and the controller is ready for you to enter the next 3-digit slot number (refer to Step a) that you want to assign a code to.
4. Do one of the following:
a. Press # to move to the next slot number.
b. If you do not wish to continue enrolling codes, press # twice
and the controller returns to Normal mode.
11.10.5 Enrolling Secondary Codes Using the Code Search Method
The Code Search feature enables you to quickly enroll a Secondary code to a user who already has a Primary code.
To enroll secondary codes using the Code Search method:
1. Enter Programming mode.
2. Press 7 to enter Menu 7.
The Door LED turns orange.
3. Enter the 3-digit User Slot number 000.
The Door LED flashes orange.
The controller is now waiting for the Primary code of the User to whom you want to add a Secondary code.
4. Present the Proximity card (AC-A42) or enter the 4-digit PIN code
of the Primary code belonging to the user for whom you want to add a Secondary code.
Mode
Door
Green
Mode
Door
Orange
Mode
Door
Orange
Page 35
Programming the AC-A4x
AC-A4x Installation and Programming Manual 35
5. The Mode LED flashes red.
If the Primary code entered is not valid, a long beep is emitted and the unit continues to wait for a valid Primary code.
6. Present the Proximity card or enter the 4-digit PIN code to be
used as the Secondary code:
If the Secondary code is valid, the controller beeps three times and returns to Normal mode.
If the Secondary code is invalid, the controller emits a long beep, and then the unit continues to wait for you to enter a valid Secondary code.
11.11 Deleting Primary and Secondary Codes
There are two methods to delete Primary and Secondary codes: the Standard Method and the Code Search method.
When deleting a user slot, both the Primary code and the Secondary code are erased.
11.11.1 42BDeleting Primary and Secondary Codes Using the Standard Method
To delete the Primary and Secondary codes using the Standard Method:
1. Enter Programming mode.
2. Press 8 to enter Menu 8.
The Mode LED turns red and the Door LED turns orange.
3. Enter the 3-digit user slot
code you wish to
delete.
Mode
Door
Red
Orange
Mode
Door
Green
Mode
Door
Red
Orange
Page 36
Programming the AC-A4x
36 AC-A4x Installation and Programming Manual
The Mode LED flashes red indicating the controller is waiting for the Programming code to confirm the deletion.
If the user slot is empty, a long beep is emitted and the unit returns to Normal mode.
4. Enter your programming code to confirm
the deletion.
If the Programming code is valid, three beeps are emitted and the
unit returns to Normal mode.
If the Programming code is invalid, a long beep is emitted and the
unit returns to Normal mode.
It is recommended that a record be kept of added and deleted users so that it is easier to keep track of which user slots are empty and which user slots are not.
11.11.2 Deleting Primary and Secondary Codes Using the Code Search Method
To delete the Primary and Secondary codes using the Code Search Method:
1. Enter Programming mode.
2. Press 8 to enter Menu 8.
The Mode LED turns red and the Door LED turns orange.
3. Enter 000 as the 3-digit user slot number.
The Door LED flashes orange, indicating that the controller is now waiting for the Primary code of the user you want to delete.
Mode
Door
Red
Orange
Mode
Door
Green
Mode
Door
Red
Orange
Mode
Door
Red
Orange
Page 37
Programming the AC-A4x
AC-A4x Installation and Programming Manual 37
The controller is now waiting for the Primary code of the user
you
want to delete.
4. Present the Proximity card or enter the 4-
digit PIN code of the Primary code belonging to the user you want to delete.
The Mode LED flashes red.
5. Enter your Programming code to confirm the deletion.
If the Programming code is valid, three beeps are emitted and the
unit returns to Normal mode.
If the Programming code is invalid, a long beep is emitted and the
unit returns to Normal mode.
It is recommended that a record be kept of added and deleted users so that it is easier to keep track of which user slots are empty and which user slots are not.
11.12 Lock Strike Relay and Auxiliary Relay Code Assignment
When a Primary code is enrolled for any user, that user is assigned rights to activate the Lock Strike Relay when a valid code is presented to the controller. The Code Assignment menu allows you to assign whether the Lock Strike Relay and/or the Auxiliary Relay is activated when a user enters a valid code.
There are two methods to assign relay codes to users: a standard method and a search method.
Mode
Door
Red
Orange
Page 38
Programming the AC-A4x
38 AC-A4x Installation and Programming Manual
11.12.1 Lock Strike Relay and Auxiliary Relay Code Assignment using Standard Method
1. Enter Programming mode.
2. Press 9 to enter Menu 9.
The Mode LED turns green and the Door LED turns orange.
3. Enter the 3-digit user slot for code
assignment.
The Mode LED flashes green.
4. Enter the assignment digit for the current user slot:
1 activates the Lock Strike relay only default
2 activates the Auxiliary relay only
3 activates the Lock Strike and Auxiliary relays
If the assignment code is valid, the Mode indicator stops flashing. The controller is now waiting for another slot number.
5. Press # to move to the next slot or enter a new slot number.
If you do not wish to continue, press # twice and the controller returns to Normal mode.
11.12.2 Lock Strike Relay and Auxiliary Relay Code Assignment using Search Method
1. Enter Programming mode.
2. Press 9 to enter Menu 9.
The Mode LED turns green and the Door LED turns orange.
Mode
Door
Green
Mode
Door
Green
Orange
Mode
Door
Green
Orange
Mode
Door
Green
Mode
Door
Green
Orange
Page 39
Programming the AC-A4x
AC-A4x Installation and Programming Manual 39
3. Enter 000 for user slot access.
The Door LED flashes orange.
The controller is now waiting for the Primary code of the user.
4. Present the Proximity card or enter
the primary code belonging to
the user.
The Mode LED flashes green.
5. Enter the assignment digit for the current user slot:
1 activates the Lock Strike relay only default
2 activates the Auxiliary relay only
3 activates the Lock Strike and Auxiliary relays
If the assignment digit is valid, three beeps are heard and the controller returns to Normal mode.
If the assignment digit is invalid, a long beep sounds and the controller waits for another assignment digit to be entered.
11.13 Return to Factory Default Settings
Be very careful before using this command as it erases the entire memory, including all User and Special codes, and returns all codes to their factory default settings.
To return to factory default settings:
1. Enter Programming mode.
2. Press 0 to enter Menu 0.
The Mode LED and the Door LED flash red.
3. Enter your 4-digit Programming code.
Mode
Door
Green
Orange
Mode
Door
Green
Orange
Mode
Door
Green
Mode
Door
Red
Red
Page 40
Programming the AC-A4x
40 AC-A4x Installation and Programming Manual
If the Programming code is valid, all memory is erased, three
beeps are emitted, and the controller returns to Normal mode.
If the Programming code is invalid, a long beep is emitted,
and the controller returns to Normal mode without erasing the memory of the controller.
11.14 Replacing a Lost Programming Code
To be able to replace a lost programming code, the unit must be in Normal mode. Before proceeding, verify that the Mode LED is green.
1. Remove power from the controller.
2. Press the REX button.
3. Apply power to the unit while pressing the REX button.
4. Release the REX button.
5. You have 15 seconds to program a new Programming code into
the unit using the initial default code 1234 before the controller reverts to the existing code.
11.15 Replacing a Lost Normal/Secure Code
To be able to replace lost Normal/Secure code, the unit must be in Secure mode. Before proceeding, verify that the Mode LED is red.
1. Remove power from the AC-A4x.
2. Press the REX button.
3. Apply power to the unit while pressing the REX button.
4. Release the REX button.
5. You have 15 seconds to program a new Normal/Secure code into
the unit using the initial default code 3838 before the controller reverts to the existing code.
Page 41
Limited Warranty
AC-A4x Installation and Programming Manual 41
A. Limited Warranty
ROSSLARE‘S TWO-YEAR LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. ROSSLARE'S TWO-YEAR LIMITED WARRANTY is subject to the following conditions:
WARRANTY
Warranty of ROSSLARE'S products extends to the original purchaser (Customer) of the ROSSLARE product and is not transferable.
PRODUCTS COVERED BY THIS WARRANTY AND DURATION
ROSSLARE warrants the AC-A4x Family of Indoor Standalone Controllers to be free from defects in materials and assembly in the course of normal use and service. The warranty period commences with the date of shipment to the original purchaser and extends for a period of 2 years (24 months).
WARRANTY REMEDY COVERAGE
In the event of a breach of warranty, ROSSLARE will credit Customer with the price of the Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty. Unless otherwise requested by a ROSSLARE representative, return of the failed product(s) is not immediately required.
If ROSSLARE has not contacted the Customer within a sixty (60) day holding period following the delivery of the warranty claim, Customer will not be required to return the failed product(s). All returned Product(s), as may be requested at ROSSLARE’S sole discretion, shall become the property of ROSSLARE.
To exercise the warranty, the user must contact ROSSLARE Enterprises Ltd. to obtain an RMA number after which, the product must be returned to the Manufacturer freight prepaid and insured.
In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day holding period and no defect is found, a
Page 42
Limited Warranty
42 AC-A4x Installation and Programming Manual
minimum US$ 50.00 or equivalent charge will be applied to each Product for labor required in the evaluation.
ROSSLARE will repair or replace, at its discretion, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by ROSSLARE or a ROSSLARE authorized service center.
EXCLUSIONS AND LIMITATIONS
ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated. This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product that is used with any ancillary equipment, which is not furnished by ROSSLARE.
This warranty does not cover expenses incurred in the transportation, freight cost to the repair center, removal or reinstallation of the product, whether or not proven defective.
Specifically excluded from this warranty are any failures resulting from Customer's improper testing, operation, installation, or damage resulting from use of the Product in other than its normal and customary manner, or any maintenance, modification, alteration, or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defects or damage due to lightning or other electrical discharge. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument, or any modification or abuse of, or tampering with, the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim.
ROSSLARE does not warrant the installation, maintenance, or service of the Product. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate.
In no event shall ROSSLARE be liable for incidental or consequential damages.
Page 43
Limited Warranty
AC-A4x Installation and Programming Manual 43
LIMITED WARRANTY TERMS
This warranty sets forth the full extent of ROSSLARE’S warranty. The terms of this warranty may not be varied by any person, whether
or not purporting to represent or act on behalf of ROSSLARE. This limited warranty is provided in lieu of all other warranties. All
other warranties expressed or implied, including without limitation, implied warranties of merchantability and fitness for a particular purpose, are specifically excluded.
In no event shall ROSSLARE be liable for damages in excess of the purchase price of the product, or for any other incidental, consequential or special damages, including but not limited to loss of use, loss of time, commercial loss, inconvenience, and loss of profits, arising out of the installation, use, or inability to use such product, to the fullest extent that any such loss or damage may be disclaimed by law.
This warranty shall become null and void in the event of a violation of the provisions of this limited warranty.
Page 44
AC-A4x Family
Asia Pacific, Middle East, Africa
Rosslare Enterprises Ltd. Kowloon Bay, Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508 support.apac@rosslaresecurity.com
United States and Canada
Rosslare Security Products, Inc. Southlake, TX, USA Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069 support.na@rosslaresecurity.com
Europe
Rosslare Israel Ltd. Rosh HaAyin, Israel Tel: +972 3 938-6838 Fax: +972 3 938-6830 support.eu@rosslaresecurity.com
Latin America
Rosslare Latin America Buenos Aires, Argentina support.la@rosslaresecurity.com
China
Rosslare Electronics (Shenzhen) Ltd. Shenzhen, China Tel: +86 755 8610 6842 Fax: +86 755 8610 6101 support.cn@rosslaresecurity.com
India
Rosslare Electronics India Pvt Ltd. Tel/Fax: +91 20 40147830 Mobile: +91 9975768824 sales.in@rosslaresecurity.com
0706-0960520+00
Loading...