Rosslare AC-425 Hardware Installation And User's Manual

Page 1
AC-425
Multi-Advanced Scalable Networked Access Controller
Hardware Installation and User Guide
November 2011
Page 2
Page 3
AC-425 Hardware Installation and User Guide
Page iii
Table of Contents
1 Introduction ..................................................................... 5
1.1 Features ........................................................................................ 7
1.2 AxTraxNG™ ................................................................................ 7
1.3 Compatible Readers ..................................................................... 9
2 Technical Specifications .............................................. 10
3 AC-425 Panel Set-Up .................................................... 12
3.1 Inputs Wiring – Non-Supervis ed Inputs ..................................... 13
3.2 Inputs Wiring – Supervised Inputs ............................................. 14
3.3 Outputs Wiring ........................................................................... 14
3.4 Power Supply ............................................................................. 15
3.5 Reader ........................................................................................ 16
3.6 MD-IO84 .................................................................................... 17
3.7 MD-D04 ..................................................................................... 17
4 Input and Output Connections .................................... 19
4.1 Input Types ................................................................................. 19
4.2 Inputs Description ...................................................................... 24
4.3 Outputs ....................................................................................... 26
4.4 Card Readers and Keypads ......................................................... 27
5 AC-425 Hardware Settings ........................................... 30
5.1 DIP Switch Configuration .......................................................... 32
5.2 AC-425 Panel Baud Rate ........................................................... 33
5.3 AC-425 Panel Type .................................................................... 34
5.4 AC-425 Panel Address ............................................................... 34
6 Communications .......................................................... 37
6.1 Serial Network Connection ........................................................ 37
6.2 TCP/IP Network Connection ...................................................... 39
6.3 Modem Network Connection ..................................................... 41
Appendix A. Limited Warranty .......................................... 43
Appendix B. Technical Support ........................................ 45
Page 4
Notice, Copyright and Disclaimer
AC-425 Hardware Installation and User Guide
Page iv
Notice, Copyright and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein.
Before attempting to install and/or use the system, the installer and the user must read this manual and become familiar with all safety requirements and operating procedures.
THE SYSTEM MUST NOT BE USED FOR PURPOSES OTHER THAN THOSE FOR WHICH IT WAS DESIGNED. T
HE USE OF THE SOFTWARE ASSOC I AT ED WIT H THE SYSTEM AND/OR PRODUCT, IF APPLICABLE, IS
SUBJECT TO THE TERMS OF THE LICENSE PROVIDED AS PART OF THE PURCHASE DOCUMENTS
.
REL,
RSP INC. AND/OR THEIR RELATED COMPANIES AND/OR SUBSIDIARIES (HEREAFTER:
"ROSSLARE") EXCLUSIVE WARRANTY AND LIABILITY IS LIMITED T O THE WARRANTY AND LIABILITY
STATEMENT PROVIDED IN AN APPENDIX AT THE END OF THIS DOCUMENT
.
T
HIS MANUAL DESCRIBES THE MAXIMUM CONFIGURATION OF THE SYSTEM WITH THE MAXIMUM
NUMBER OF FUNCTIONS
, INCLUDING FUTURE OPTIONS. THEREFORE, NOT ALL FUNCTIONS DESCRIBED
IN THIS MANUAL MAY BE AVAILABLE IN THE SPECIFIC SYSTEM AND
/OR PRODUCT CONFIGURATION YOU
PURCHASED
.
I
NCORRECT OPERATION OR INSTALLA TION, OR FAILURE OF THE USER TO EFFECTIVELY MAINTAIN THE
SYSTEM
, RELIEVES THE MANUFACTURER (AND SELLER) FROM ALL OR ANY RESPONS IBILITY FO R
CONSEQUENT NON
-COMPLIANCE, DAMAGE, OR INJURY.
T
HE TEXT, IMAGES AND GRAPHICS CONTAINED IN THE MANUAL ARE FOR THE PURPOSE OF
ILLUSTRATION AND REFERENCE ONLY
.
I
N NO EVENT SHALL MANUFACTURER BE LIABLE FOR ANY SPECIA L, DIRECT, INDIRECT, INCIDENTAL,
CONSEQUENTIAL
, EXEMPLARY, OR PU NITIVE DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY AND
ALL DAMAGES FROM BUSINESS INTERRUPTION
, LOSS OF PROFITS OR REVENUE, COST OF CAPITAL OR
LOSS OF USE OF ANY PROPERTY OR CAPITAL OR INJURY
).
A
LL GRAPHICS IN THIS MANUAL ARE FOR REFERENCE ONLY, SOME DEVIATION BETWEEN THE IMAGE(S)
AND THE ACTUAL PRODUCT MAY OCCUR
.
A
LL WIRING DIAGRAMS ARE INTENDED FOR REFERENCE ONLY, THE PHOTOGRAPH OR GRAPHIC OF THE
PCB(S) ARE INTENDED FOR CLEARER ILLUSTRATION AND UNDERSTANDING OF THE PRODUCT AND
MAY DIFFER FROM THE ACTUAL
PCB(S).
COPYRIGHT 2011 by Rosslare. All rights reserved.
This manual and the information contained herein are proprietary to ROSSLARE. Only ROSSLARE and its customers have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual.
T
EXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT
ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE
. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT
EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS
.
The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other int ellectual propert y rights, except as expressly provided in any written agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
Page 5
Introduction
AC-425 Hardware Installation and User Guide
Page 5
1. Introduction
The AC-425 access control panel is a state-of-the-art networked access controller, employing the latest technology to meet the requirements of the market.
The state-of-the-art dual/quad door AC-425 networked access controller is the backbone of medium scale security systems handling up to 30,000 users and 8184 doors.
Each AC-425 Access Control Unit (ACU) supports four readers (In/Out) of various formats including standard Wiegand 26-bit. Installations can also have one reader per door.
Driven by Rosslare’s powerful, flexible and easy to use AxTraxNG™ software, the system provides an ideal, modular and expandable solution for commercial and institutional needs. It provides seamless integration with Rosslare's range of RFID proximity, PIN, PIN & PROX, smartcard and biometric readers with Rosslare’s selection of RFID credentials.
The AC-425 is ready for installation with a mountable & lockable metal enclosure integrated with transformer, power supply/charger, sounder and control board.
Using onboard RS-232/485, Ethernet TCP/IP, multiple local or remote site door sub-networks can connect to the AxTraxNG Client/Server PC software running on Microsoft
®
Windows®
98/ME & NT/2000/XP/7 operating systems. The AC-425 consists of the following components:
AC-425 controller board
Panel enclosure
PS-33 power supply
Power Transformer
4 x 2.2 kOhm and 4 x 8.2 kOhm resistors for the supervised
inputs.
Page 6
Introduction
AC-425 Hardware Installation and User Guide
Page 6
Figure 1: AC-425 panel
Page 7
Introduction
AC-425 Hardware Installation and User Guide
Page 7
1.1 Features
The AC-425 is a powerful and adaptable access control solution with a range of powerful features.
Controls 1 to 4 doors (DIP switch controlled) or 1 to 8 doors when the optional MD-D04 is installed
Four IN/OUT readers, with tamper switch and LED control
Four inputs, selectable as supervised or non-supervised
Four Form-C relay outputs (rated 5 A)
Optional MD-IO84 with an additional 4 relay outputs and 8
inputs, selectable as supervised or non-supervised
Optional MD-D04 with 4 readers, 4 relay outputs, and 4 inputs selectable as supervised or non-supervised
Built-in sounder generator for chime, bell and siren signals
Panel configuration DIP switch
Up to 32 access control panels in every network (128 doors
in every network or a 256-door network when optional MD­D04 installed)
30,000 users
20,000 FIFO, history event log
RS-232 or RS-485 serial communication (up to 115200 bps)
On-board TCP/IP communication
Remote firmware upgrades
Removable terminal blocks
Real-time clock keeps time for up to 2 weeks without
power (no batteries to replace)
1.2 AxTraxNG™
The AxTraxNG™ software system is custom designed to set up, manage, and supervise all aspects of an access panel network.
Page 8
Introduction
AC-425 Hardware Installation and User Guide
Page 8
It offers the following capabilities:
Parameter
Value
Users capacity 30,000
Unauthorized Use rs
30,000
Access groups
30,000
Number of pa nels in system
1023
Number of doors in system
8184
Note:
These options are softw are and firmware dependent, a nd may change in later releas es or revisions.
1.2.1 Client-Server Structure
AxTraxNG™ operates through a dedicated AxTraxNG™ server computer, which communicates with the access control panels and can serve an unlimited number of network clients.
The server also runs the system's SQL database, which contains settings and definitions for access control across the entire facility. System users can define new cards holders and users, and control access permissions. The system includes tools for database backup, input, and export of previous configurations and automatic backup on a periodic basis.
AxTraxNG™ supports all panel types and offers scalability and flexibility in addition to a range of advanced control features.
1.2.2 Configurable Links
The system's configurable links model makes it possible to trigger any chosen output automatically or report a configurable alarm, based on a selected input. This allows easy integration with other access systems such as intruder alarms, CCTV systems, and elevator controls.
AxTraxNG™ can also define a selected set of operations, which are defined in configurable links, when a panel registers a specified user or group of users. This can be useful, for
Page 9
Introduction
AC-425 Hardware Installation and User Guide
Page 9
example, in elevator control systems. The system can assign users with counters, allowing a limited number of entries to each panel.
1.2.3 Fingerprint Recognition
AxTraxNG™ can share user details with Rosslare's BioTrax software system. The BioTrax system can then download all selected user information to an AY C-W6500 fingerprint reader.
Note:
Fingerprint recognition was not evaluated by UL.
1.3 Compatible Readers
For UL-compliant installations, use any of the following UL-listed PIN and PROX card readers made by Rosslare:
AY-H 1 2, AY-J12, AY-K12, AY-L12, AY-M12, AY-Q12, AYC-F54, AYC-F6 4 , AYC -G54, AYC-G64, AYC-Q54B, or AYC-Q64B
Page 10
Technical Specifica tion s
AC-425 Hardware Installation and User Guide
Page 10
2. Technical Specifications
Parameter
Description/Value
Electrical Characteristics
Operating Voltage 13.8 VDC 1.5 A from PS-33 Maximum Input Current Standby: 80 mA
Maximum: 325 mA
General Inputs 4 supervised high impedance inputs.
8 or 12 supervised inputs when using MD-D04
or
MD-IO84 expansion boards Maximum v oltage : 5 VDC
Relay Outputs 4 relay outputs
8 supervised outputs when using MD-D04 or MD-IO84 expansion boards
5A relay N.O. and N.C. options
Reader Ports Standard = 4 reader ports
With MD-D04 = 8 reader ports Output voltage: 12 VDC Max. current: 245 mA
LED control output D0/D1, tamper input
Visual Indicators
9 LEDs (14 LEDs with MDD04)
Audio Built-in sounder (bell, chime, and siren)
Battery Standby Time
3 hours (with 12 V batter y
Communication Characteristics
RS-232
Terminal Block
RS-485
Molex and Terminal Block
TCP/IP On-board RJ-45 connector
Internal IP module
Speed Options 9600, 19200, 57600, 115200 bps
Environmental Characteristics
Operating Temperature
Range
32°F – 120°F (0°C – 49°C)
Operating Humidity 0 – 85% (non-condensing)
Page 11
Technical Specifica tion s
AC-425 Hardware Installation and User Guide
Page 11
Parameter Description/Value
Dimensions
Height x Wid th x Depth 10.4 x 13.2 x 3.4 in.
264 x 334 x 84.5 mm
Weight 8.38 lbs. (3.80 kg)
PS-33 Power Supply Specifications
Input Voltage
16.5 VAC, 3 A
Backup Battery Charger Output
12 VDC, 300 mA
To Access control panel – Output Voltage 1
13.8 VDC, 1.5 A
To Relay Outputs
Output Voltage 2
13.8 VDC, 0.9 A
PS-33 Power Supply Indication
Tamper Output
(open c ollector)
Indicates fau lt y power
PS-33 Power LEDs
Power In (AC)
Green LED1
Main power
Power O ut (DC)
Red LED2
Low voltage
Low Battery
Red LED3
Backup batt ery low voltage
Page 12
AC-425 Panel Set-Up
AC-425 Hardware Installation and User Guide
Page 12
3. AC-425 Panel Set-Up
Each AC-425 panel controls 2 or 4 doors (up to 8 doors with MD-D04). The panels connect together in a network and are controlled by a central server computer, running the AxTraxNG™ software system.
The following diagram shows an example setup for a network of AC -425 access control panels.
Figure 2: Sample AC-425 Configuration
Page 13
AC-425 Panel Set-Up
AC-425 Hardware Installation and User Guide
Page 13
Note:
Bushings are needed for any conductors leaving the enclosure through the provided openings.
3.1 Inputs Wiring – Non-Supervised Inputs
Figure 3: Inputs Wiring – Non-supervised Inputs
Page 14
AC-425 Panel Set-Up
AC-425 Hardware Installation and User Guide
Page 14
3.2 Inputs Wiring – Supervised Inputs
When wiring the AC-425 for supervised inputs, resistors should be placed on the input switch and not on the terminal block.
For more details, refer to Input and Output Connections on page 19.
3.3 Outputs Wiring
The following diagram illustrates wiring for two main types of 12 VDC electrical release mechanisms. Other electrical devices can be switched using the voltage free relay contacts.
Figure 4: Door Lock – Failed Close
Page 15
AC-425 Panel Set-Up
AC-425 Hardware Installation and User Guide
Page 15
Figure 5: Door Lock – Failed Open
3.4 Power Supply
The following diagram illustrates wiring between the PS-33 power supply and the AC-425. It is recommended to add a 12 VDC lead acid backup battery if the main power supply fails. If the main output is 12 VDC, wire it to the PS-33, whose load ratings are 1.5 A/0.9 A/0.3 A; otherwise, you should support your power supply according to the output requirements. For more information, refer to the Outputs on page 26
. A 12 V 7 AH
battery will provide 3 hours of backup operation.
Page 16
AC-425 Panel Set-Up
AC-425 Hardware Installation and User Guide
Page 16
Figure 6: Wiring Between PS-33 and AC-425
3.5 Readers
Proximity & keypad readers are supplied with a limited cable. The color of the cable cover represents the cable’s function according to Wiegand standards.
Note:
When extending the cable distance, be careful with the col or of the cable cover.
Refer to the reader specifications for the maximum cable length (typically 150 m with an 18 AWG cable).
Page 17
AC-425 Panel Set-Up
AC-425 Hardware Installation and User Guide
Page 17
Figure 7: Reader Wiring
3.6 MD-IO84
The MD-IO84 is an optional I/O expansion board that adds 4 relay outputs and 8 supervised inputs to the Access Control Panel. Attach the MD-IO84 to the AC-425's expansion slot, as marked in red in Figure 8). For more information, see the MD­IO84 Installation and User Guide.
3.7 MD-D04
The MD-D04 is an optional reader expansion board that adds 4 readers, 4 relay outputs and 4 supervised inputs to the Access Control Panel. Attach the MD-D04 to the AC-425's expansion slot, as marked in red in Figure 8. For more information, see the MD-D04 Installation and User Guide.
Page 18
AC-425 Panel Set-Up
AC-425 Hardware Installation and User Guide
Page 18
Figure 8: Connector Location for MD-IO84 or MD-D04 Expansions
Page 19
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 19
4. Input and Output Connections
This chapter describes the AC-425 access control panel's input and output connections.
4.1 Input Types
There are four input types:
N.C.
N.O.
Single EOL resistor
Double EOL resistor
Inputs IN1, IN2, IN3, and IN4 may be configured individually as either supervised or non-supervised inputs. Use the AxTraxNG™ system to configure each input separately.
Non-supervised inputs have two states:
Normal
Abnormal
Supervised inputs have three states:
Normal
Abnormal
Trouble
The Trouble state is caused by either tampering with the input circuit or by faulty hardware installation. Once an input is configured as a supervised input, add a resistor of 2.2 kΩ, of
8.2 kΩ, or both on the input circuit. See the following diagrams.
Page 20
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 20
4.1.1 Normally Open Input Connectio n
A Normally Open Input has 2 states:
Switch Open – Normal State: Loop resistance = Infinite (open circuit)
Switch Closed – Abnormal State: Loop resistance = 0 (short circuit)
Figure 9: Normally Open Input Connection
4.1.2 Normally Closed Input Connection
A Normally Closed Input has two states:
Switch Closed – Normal State: Loop resistance = 0 (short circuit)
Switch Open – Abnormal State: Loop resistance = Infinite (open circuit)
Figure 10: Normally Closed Input Connection
Page 21
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 21
4.1.3 Normally Open Supervised Single EOL Resistor Input
Connection
Connect an 8.2 kΩ resistor in parallel to the input switch contacts.
A Normally Open Supervised Input has 3 states:
Switch Open – Normal State: Loop resistance = 8.2 kΩ
Switch Closed – Abnormal State: Loop resistance = 0 (short circuit)
Open circuit across input terminals – Trouble State: Loop resistance = Infinite (open circuit).
Figure 11: Normally Open Supervised Input (Single Resistor)
4.1.4 Normally Open Supervised Double EOL Resistor Input
Connection
Connect a 2.2 kΩ resistor in series to the input switch contacts. Connect an 8.2 kΩ resistor parallel to the input switch
contacts.
Page 22
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 22
A Normally Open Supervised Input has 3 states:
Switch Open – Normal State: Loop resistance = 10.4 kΩ
Switch Closed – Abnormal State: Loop resistance = 2.2 kΩ
Open circuit (infinite loop resistance) or short circuit (0 resistance) across input terminals – Trouble State
Figure 12: Normally Open Supervised Input (Double Resistor)
4.1.5 Normally Closed Supervised Single EOL Resistor Input
Connection
Connect a 2.2 kΩ resistor in series to the input switch contacts. A Normally Closed Supervised Input has 3 states:
Switch Closed – Normal State: Loop resistance = 2.2 kΩ
Switch Open – Abnormal State: Loop resistance = Infinite (open circuit)
Short circuit across input terminals – Trouble State: Loop resistance = 0 (short circuit)
Page 23
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 23
Figure 13: Normally Closed Supervised Input (Single Resistor)
4.1.6 Normally Closed Supervised Double EOL Resistor Input
Connection
Connect a 2.2 kΩ resistor in series to the input switch contacts. Connect an 8.2 kΩ resistor parallel to the input switch
contacts. A Normally Closed Supervised Input has 3 states:
Switch Closed – Normal State: Loop resistance = 2.2 kΩ
Switch Open – Abnormal State: Loop resistance = 10.4 kΩ
Open circuit (infinite loop resistance) or short circuit (0 resistance) across input terminals – Trouble State
Page 24
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 24
Figure 14: Normally Closed Supervised Input (Double Resistor)
4.2 Inputs Description
4.2.1 Request to Exit Button (REX) Input
Use the REX Input to open a door directly. Typically, the REX input is connected to a Normally Open push button that is located inside the premises. The push button is generally located in an easy-to-access position and opens a door without reading a proximity card or PIN code.
Scenario
Setting
Two readers per door Door 1 – IN 1
Door 2 – IN 2
One reader per door
Door 1 – IN 1
Door 2 – IN 2
Door 3 – IN 3
Door 4 – IN 4
Page 25
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 25
REX Inputs functions when using MD-D04:
Scenario Setting
Two readers per door
Door 1 – IN1
Door 2 – IN2
Door 5 – IN5
Door 6 – IN6
One reader per door
Door 1 – IN1
Door 2 – IN2
Door 3 – IN3
Door 4 – IN4
Door 5 – IN5
Door 6 – IN6
Door 7 – IN7
Door 8 – IN8
4.2.2 Door Monitor Input
The Door Monitor Input typically connects to a Normally Closed door sensing micro-switch for door status monitoring. Using Door Monitor enables many advanced options such as door forced alarm, door held open warnings, interlocking doors and more. Door monitor feature is only available when the system is defined as a two reader per door. The following should be defined:
Scenario Setting
Two readers per door
Door 1 – IN3
Door 1 – IN4
Dedicated Inputs functions when using MD-D04:
Scenario
Setting
Two readers per door Door 1 – IN3
Door 2 – IN4 Door 3 – IN7
Door 4 – IN8
Page 26
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 26
4.2.3 General Purpose Inputs
These are free inputs that can be used for various functions. This function is only available with the MD-IO84 expansion. The following should be defined:
Scenario Setting
Single door controller Door 1 – IN 2
Door 1 – IN 2A
Double door controller (no general purpose inputs
available)
General purpose inputs are suitable for most uses. For example, they might be used to detect tampering, to activate alarm sensors, or to monitor a power supply failure.
General purpose inputs functions when using MD-IO84 or MD­D04:
Unit Expansions
MD-IO84
IN5 to IN12
MD-D04 IN5 to IN8 except the dedi cated
inputs
4.3 Outputs
Rosslare Security recommends the use of suppression diodes for all outputs that activate an inductive load.
4.3.1 Door Lock
There are two types of door locking devices:
Fail open (fail secure)
Fail close (fail safe)
The following should be defined:
Scenario Setting
Two readers per door
Door 1 – OUT 1
Door 2 – OUT 2
One reader per door
Door 1 – OUT 1
Door 2 – OUT 2
Door 3 – OUT 3
Page 27
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 27
Scenario
Setting
Door 4 – OUT 4
Door outputs when using MD-D04:
Scenario
Setting
Two readers per door Door 1 – OUT 1
Door 2 – OUT 2
Door 3 – OUT 5
Door 4 – OUT 6
One reader per door
Door 1 – OUT 1
Door 2 – OUT 2
Door 3 – OUT 3
Door 4 – OUT 4
Door 5 – OUT 5
Door 6 – OUT 6
Door 7 – OUT 7
Door 8 – OUT 8
The output can sink current from any power supply (see page
15).
Note:
For UL installations, the installer must configure the system as fail-safe to comply with N FPA (National Fire Protection Association) regulations.
4.4 Card Readers and Keypads
Each access control panel can be connected to a maximum of four readers or 8 readers when using MD-D04. There are three available types of reader:
Card readers
Keypads
Dual keypad card readers
A keypad is required for any reader mode that requires PIN code entries, such as "Card or PIN", "PIN Only" or "Card and PIN (Secured mode)".
When connecting a reader, the following should be defined:
Page 28
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 28
Scenario
Setting
Two readers per door
Door 1 – Reader 1 IN/OUT
Door 1 – Reader 3 IN/OUT
Door 2 – Reader 2 IN/OUT
Door 2 – Reader 4 IN/OUT
One readers per door
Door 1 – Reader 1 IN/OUT
Door 2 – Reader 2 IN/OUT
Door 3 – Reader 3 IN/OUT
Door 4 – Reader 4 IN/OUT
When using the MD-D04, the following should be defined:
Scenario
Setting
Two readers per door:
Door 1 – Reader 1 IN/OUT
Door 1 – Reader 3 IN/OUT
Door 2 – Reader 2 IN/OUT
Door 2 – Reader 4 IN/OUT
Door 3 – Reader 5 IN/OUT
Door 3 – Reader 7 IN/OUT
Door 4 – Reader 6 IN/OUT
Door 4 – Reader 8 IN/OUT
One readers per door: Door 1 – Reader 1 IN/OUT
Door 2 – Reader 2 IN/OUT
Door 3 – Reader 3 IN/OUT
Door 4 – Reader 4 IN/OUT
Door 5 – Reader 5 IN/OUT
Door 6 – Reader 6 IN/OUT
Door 7 – Reader 7 IN/OUT
Door 8 – Reader 8 IN/OUT
Use the AxTraxNG™ software to set the readers for IN or OUT use and to set the data transmission format for each reader.
The reader’s tamper output connects to the access control panel's Reader-Tamper input. If the reader is interfered with, an alarm can be generated.
The panel's Reader G.LED output activates the reader’s green LED input when operating in "Card and PIN" secure mode.
Page 29
Input and Output Connections
AC-425 Hardware Installation and User Guide
Page 29
While this mode is in force, users must enter a PIN on the keypad immediately after entering the card.
The controller activates the LED control for 2 seconds when an access granted event occurs.
Page 30
AC-425 Hardware Settings
AC-425 Hardware Installation and User Guide
Page 30
5. AC-425 Hardware Settings
Each AC-425 panel controls an entrance. The behavior of the panel is controlled by DIP switch settings.
Select the appropriate DIP switch setting to operate the panel as either a single door, a double door, or four doors. Refer to AC-425 Panel Type, on page 34.
Access control panels, configured as either single door or double door controllers, have two readers, IN or OUT. Access control panels configured with the MD-D04 expansion as either double door or four-door controllers have four readers.
Connectors
Description
Setup
Two readers per door:
Outputs
Door 1 Lock output
(OUT 1)
Door 2 Lock output (OUT 2)
General purpose output
(OUT 3)
General purpose output (OUT 4)
Inputs
Door 1: Request to exit
(IN 1)
Door monitor input
(IN 3)
Door 2: Request to exit
(IN 2)
Door monitor input
(IN 4)
Readers
Reader1 – Door1
Door Entry or Exit
Reader2 – Door2
Door Exit or Entry
Reader3 – Door1 Door Entry or Exit
Reader4 – Door2
Door Exit or Entry
One reader per door:
Outputs
Door1 Lock output
(OUT 1)
Door2 Lock output
(OUT 2)
Door3 Lock output
(OUT 3)
Door4 Lock output
(OUT 4)
Inputs Door1 Requ est to exit (IN 1)
Door2 Requ est to exit
(IN 2)
Door3 Request to exit (IN 3)
Door4 Request to exit
(IN 4)
Page 31
AC-425 Hardware Settings
AC-425 Hardware Installation and User Guide
Page 31
Connectors
Description
Setup
Readers
Reader1
(Door1 IN/OUT)
Reader2
(Door2 IN/OUT)
Reader3
(Door3 IN/OUT)
Reader4 (Door4 IN/OUT)
Two readers per door with 8 readers (MD-D04):
Outputs Door1 Lock output (OUT 1)
Door2 Lock output
(OUT 2)
Door3 Lock output
(OUT 5)
Door4 Lock output
(OUT 6)
Inputs
Door1 Requ est to exit
(IN 1)
Door1 monitor input
(IN 3)
Door2 Request to exit
(IN 2)
Door2 monitor input (IN 4)
Door3 Request to exit
(IN 5)
Door3 monitor input (IN 7)
Door4 Request to exit
(IN 6)
Door4 monitor input
(IN 8)
Readers
Reader1
(Door1 IN/OUT)
Reader2
(Door2 OUT/IN)
Reader3
(Door1 IN/OUT)
Reader4
(Door2 OUT/IN)
Reader5 (Door3 IN/OUT)
Reader6
(Door4 OUT/IN)
Reader7 (Door3 IN/OUT)
Reader8
(Door4 OUT/IN)
One reader per door with 8 readers (MD-D04)
Outputs
Door1 Lock output
(OUT 1)
Door2 Lock output
(OUT 2)
Door3 Lock output
(OUT 3)
Door4 Lock output
(OUT 4)
Door5 Lock output (OUT 5)
Door6 Lock output
(OUT 6)
Door7 Lock output (OUT 7)
Door8 Lock output
(OUT 8)
Page 32
AC-425 Hardware Settings
AC-425 Hardware Installation and User Guide
Page 32
Connectors
Description
Setup
Inputs
Door1 Requ est to exit
(IN 1)
Door2 Requ est to exit
(IN 2)
Door3 Requ est to exit
(IN 3)
Door4 Request to exit (IN 4)
Door5 Request to exit
(IN 5)
Door6 Request to exit (IN 6)
Door7 Request to exit
(IN 7)
Door8 Request to exit
(IN 8)
Readers
Reader1
(Door1 IN/OUT)
Reader2
(Door2 OUT /IN)
Reader3
(Door3 IN/OUT)
Reader4
(Door4 OUT /IN)
Reader5 (Door5 IN/OUT)
Reader6
(Door6 OUT /IN)
Reader7 (Door7 IN/OUT)
Reader8
(Door8 OUT /IN)
5.1 DIP Switch Configuration
The AC-425 panel DIP switch controls a number of operating parameters, including the device address and baud rates for serial communication.
Figure 15: DIP Switch
The following is a list of DIP switch numbers and their functions:
DIP
Switch
Function
1
Panel's communication baud rate .
2
3 Panel type
Defines the number of readers for each door – one or two readers per door. This will also affect the number of doors controlled by the
panel.
1 2 3 4 5 6 7 8
Up is ON Down is OFF
Page 33
AC-425 Hardware Settings
AC-425 Hardware Installation and User Guide
Page 33
4
AC-425 panel's RS-485 network address.
5
6
7
8
Note:
Power off the access control panel before changing the DIP switch settings.
After changes have been made, reboot the pane l. The new
settings are automatically defined after power up.
5.2 AC-425 Panel Baud Rate
The AC-425 panel serial port baud rate, set in DIP switches 1 and 2, defines the communication speed for connecting with a PC in a network connection.
The default baud rate is set to 9600 bits per second.
Figure 16: DIP Switch with Baud Rate Setting
The following lists the status of Switches 1 and 2 and the baud rate:
Switch 1
Switch 2
Baud Rate
Off
Off
9600
Off
On
19200
On
Off
115200
On
On
57600
1 2 3 4 5 6 7 8
Page 34
AC-425 Hardware Settings
AC-425 Hardware Installation and User Guide
Page 34
Note:
The access co n tr ol panel baud r a te mu s t be i dentical to the AxTraxNG™ Network configuration of baud rate.
5.3 AC-425 Panel Type
The AC-425 panel type is defined using the third DIP switch. There are two panel types: a panel with one reader per each door or a panel with two readers per each door. This DIP switch setting influences the number of readers per door in the panel.
The default AC-425 panel setting is for two readers per each door.
Figure 17: DIP Switch for Door Setting
Off – Defines using two readers for each door. Panel controls two or four doors when MD-D04 is installed.
On – Using one reader for each door. Panel controls four doors or eight doors when MD-D04 installed.
5.4 AC-425 Panel Address
The last 5 DIP switches are used to set the binary code of the access control panel internal network address.
The default access control panel address is “1”.
1 2 3 4 5 6 7 8
Page 35
AC-425 Hardware Settings
AC-425 Hardware Installation and User Guide
Page 35
Figure 18: DIP Switch with Internal Network Address Setting
Note:
For successful communications, the DIP switch must match the address set in the AxTraxNG™ software.
The following table displays the 32 address settings available:
Address
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
1 Off Off Off Off Off
2
Off
Off
Off
Off
On
3 Off Off Off On Off
4
Off
Off
Off
On
On
5
Off
Off
On
Off
Off
6
Off
Off
On
Off
On
7
Off
Off
On
On
Off
8
Off
Off
On
On
On 9 Off
On
Off
Off
Off
10 Off On Off Off On
11
Off
On
Off
On
Off
12 Off On Off On On
13
Off
On
On
Off
Off
14
Off
On
On
Off
On
15
Off
On
On
On
Off
16
Off
On
On
On
On
17
On
Off
Off
Off
Off
18
On
Off
Off
Off
On
19 On Off Off On Off
20
On
Off
Off
On
On
21 On Off On Off Off
22
On
Off
On
Off
On
1 2 3 4 5 6 7 8
Page 36
AC-425 Hardware Settings
AC-425 Hardware Installation and User Guide
Page 36
Address
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
23 On Off On On Off
24
On
Off
On
On
On
25 On On Off Off Off
26
On
On
Off
Off
On
27
On
On
Off
On
Off
28
On
On
Off
On
On
29
On
On
On
Off
Off
30 On On On Off On
31
On
On
On
On
Off
32 On On On On On
Note:
The AC-425 panel address is defined in the AxTraxNG™ software.
The DIP switch and the software must be set to the same
address.
Page 37
Communications
AC-425 Hardware Installation and User Guide
Page 37
6. Communications
Communication lines are used to upload and download information between the AC-425 panel and the AxTraxNG™ server. When the access control panel and the computer are communicating, the system’s two LEDs flash accordingly.
The RX LED flashes when the controller receives data
The TX LED flashes when the controller transmits data
There are three connection modes:
Serial Network (RS-232 or RS-485)
Modem Network
TCP/IP Network
6.1 Serial Network Connection
The computer serial port controlling the access control panel is set from within the AxTraxNG™ server. The default baud rate is 9600 bps for direct connection to the computer.
When using an RS-232 connector, only one AC-425 panel can be linked to each communication port on the computer. Use an RS-485 if you wish to connect more than one panel on one communication port.
Note:
The J1 switch must be se t to the corre c t po sition to select the RS­232 communicati on.
6.1.1 RS-232 Connection to the Computer
Set the J1 switch to the RS-232 position.
Access control panel
DB9 Connector
DB25 Connector
GND Pin 5 Pin 7
Tx
Pin 2
Pin 3
Rx Pin 3 Pin 2
Page 38
Communications
AC-425 Hardware Installation and User Guide
Page 38
Note:
The RS-232 connects the computer to only a single AC-425 panel.
The distance between the c omputer and the AC-425 panel must be no more than 150 feet (50 meters).
If the baud rate is increased to 57600 or beyond, the distance
must be no more than 30 feet (10 meters).
6.1.2 RS-485 Connection to the Computer
Set the J1 switch to the RS-485 position. Up to 32 access control panels (AC-425 , AC-225, AC-215, or
AC-525) can be linked together and connected to a single communication port on the computer.
Use the RS-485 interface for situations where there are multiple controllers connected. The serial port used to control the access control panel is assigned within the AxTraxNG™ software.
The AC-425 panel supports a 2-wire RS-485 interface. Using the RS-485 interface can increase the distance between server and panels up to 4,000 feet.
To use the RS-485 interface, the panels must be connected in a daisy-chain formation with an MD-14 adapter.
6.1.3 Daisy Chaining
You can connect up to 32 panels to a single serial line using a daisy-chain formation.
The first panel is connected directly to the server using an MD­14 adaptor, while the second panel connects to the first panel. Additional panels are connected in the same way, one after another. The maximum distance from the PC to the last panel in the chain is 4,000 ft (1,219.2 m).
Page 39
Communications
AC-425 Hardware Installation and User Guide
Page 39
Figure 19: Daisy Chaining
At each end of the data line, both where the panel connects to the server and on the last panel in the network, a termination resistor of 120 Ω may be required. Apply the resistor across the L1 and L2 connections.
Note:
These termination resi stors are e specially impo rtant in lo ng cable runs.
6.2 TCP/IP Network Connection
The computer running the AxTraxNG™ server can communicate with the access control panels via a TCP/IP network. The connection settings are controlled within the AxTraxNG™ Client software.
AC-425 panels connect to the TCP/IP network (LAN or WAN) directly, using an on-board network module. When an access control panel network is connected using RS-485, up to 32 panels can be connected on each TCP/IP network.
Page 40
Communications
AC-425 Hardware Installation and User Guide
Page 40
6.2.1 LAN and WAN Requirements
The devices can be connected to a TCP/IP network using any valid network address.
Use a TCP/IP connection when a LAN network already exists and the long RS-485 network is not required. The following schematic illustrates the connection of a single AC-425 to a computer via a LAN network.
Figure 20: MD-N32 Configuration connecting a single panel
The maximum distance from the Ethernet port of the panel to the LAN/WAN connection is 328 ft. (99.97 m).
When the TCP/IP connection is implemented over a Wide Area Network (WAN), it becomes possible to connect through the Internet. This makes it possible to control multiple access control panels worldwide, all from a single server.
Figure 21: Connecting Multiple Access control panels with AC-425
Page 41
Communications
AC-425 Hardware Installation and User Guide
Page 41
Before connecting a panel by TCP/IP connection for the first time, the AxTraxNG™ software must configure the device. Settings are then stored in non-volatile memory on the device (see the AxtraxNG™ Software Manual).
6.3 Modem Network Connection
Access control panels can be controlled from the computer's modem. The modem is assigned from within the AxTraxNG™ software.
Use a modem when the access control panel is too far from the computer to use a serial connection and an alternative RS-232/RS-485 network or TCP/IP network is unavailable.
The following diagram illustrates remote site modem configuration with AC-425.
Figure 22: Remote Site Modem Configuration
Note:
For more informat ion o n modem connections, refer to the MD­N33 User Manual and the AxTraxNG™ Software Manual.
6.3.1 Hardware Requirements
2 standard telephone cables – RJ11 plugs in both sides
Crossed 9-pin RS-232 cable (female jack on both sides)
Rosslare MD-14 (RS-232 to RS-485 converter)
2 Rosslare MD-N33 (modem to serial gateway)
Rosslare AC-425 panel
Page 42
Communications
AC-425 Hardware Installation and User Guide
Page 42
6.3.2 Prerequisites
Before performing permanent modem installations, the modem that will be connected to the panel must be initialized from the computer running the AxTraxNG™ software.
6.3.3 Computer Connecti ons
The MD-N33 must connect to the computer via a serial port.
To connect to the PC:
1. Connect a 9 VDC adapter to the first MD-N33. Make sure that the power LED (red) is on.
2. Connect the PC using an available COM port to the MD­N33 with a crossed 9-pin RS-232 cable.
3. Connect the MD-N33's RJ11 jack to the telephone line using the telephone cable.
6.3.4 AC-425 Panel Connecti ons
1. Connect a 9 VDC adapter to the second MD-N33. Make sure that the power LED (red) is on.
2. Connect the MD-N33's RJ11 jack to the telephone wall mount using the telephone cable.
3. Connect the MD-N33 DB9 female jack to the MD-14 DB9 female jack.
4. Connect the AC-425 RS-485 outlet to the MD-14 4 wires cable. Make sure the J1 switch (on the AC-425) is set to RS­485 Mode.
Page 43
Limited Warranty
AC-425 Hardware Installation and User Guide
Page 43
Appendix. A Limited Warranty
ROSSLARE ENTERPRISES LIMITED (ROSSLARE) TWO-YEAR LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. ROSSLARE'S TWO-YEAR LIMITED WARRANTY is subject to the following conditions:
Warranty
Warranty of ROSSLARE'S products extends to the original purchaser (Custom er) of the ROSSLARE product and is not transferable.
Products Covered By This Warranty and Duration
ROSSLARE ENTERPRISES LTD. AND/OR SUBSIDIARIES (ROSSLARE) warrants that the AC-425 Access Control Panel is free from defects in materials and assembly in the course of normal use and service. The warranty period commences with the date of shipment to the original purchaser and extends for a period of 2 years (24 months).
Warranty Remedy Coverage
In the event of a breach of warranty, ROSSLARE will credit Customer with the price of the Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty. Unless otherwise requested by ROSSLARE representative, return of the failed product(s) is not immediately required.
If ROSSLARE has not contacted the Customer within a sixty (60) day holding period following the delivery of the warranty claim, Customer will not be required to return the failed product(s). All returned Product(s), as may be requested at ROSSLARE’S sole discretion, shall become the property of ROSSLARE.
To exercise the warranty, the user must contact ROSSLARE to obtain an RMA number after which, the product must be returned to the Manufacturer freight prepaid and insured.
In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day holding period and no defect is found, a minimum US$ 50.00 or equivalent charge will be applied to each Product for labor required in the evaluation.
ROSSLARE will repair or replace, at its discretion, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by ROSSLARE or a ROSSLARE authorized service center.
Exclusions and Limitations
ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated. This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, nor to any
Page 44
Limited Warranty
AC-425 Hardware Installation and User Guide
Page 44
Product that is used with any ancillary equipment, which is not furnished by ROSSLARE.
This warranty does not cover expenses incurred in the transportation, freight cost to the repair center, removal or reinstallation of the product, whether or not proven defective.
Specifically excluded from this warranty are any failures resulting from Customer's improper testing, operation, installation, or damage resulting from use of the Product in other than its normal and customary manner, or any maintenance, modification, alteration, or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defects or damage due to lightning or other electrical discharge. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument, or any modification, abuse of, or tampering with the Product, if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim.
ROSSLARE does not warrant the installation, maintenance, or service of the Product. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall ROSSLARE be liable for incidental or consequential damages.
Limited Warranty Terms
THIS WARRANTY SETS FORTH THE FULL EXTENT OF ROSSLARE WARRANTY. THE TERMS OF THIS WARRANTY MAY NOT BE VARIED BY ANY PERSON, WHETHER OR NOT
PURPORTING TO REPRESENT OR ACT ON BEHALF OF
ROSSLARE.
THIS LIMITED WARRANTY IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES. ALL OTHER WARRANTIES
, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
, ARE
SPECIFICALLY EXCLUDED
.
IN NO EVENT SHALL ROSSLARE BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT
, OR FOR ANY OTHER INCIDENTAL, CONSEQUENTIAL OR SPECIAL
DAMAGES
, INCLUDING BUT NOT LIMITED TO LOSS OF USE, LOSS OF TIME, COMMERCIAL
LOSS
, INCONVENIENCE, AND LOSS OF PROFITS, ARISING OUT OF THE INSTALLATION, USE, OR
INABILITY TO USE SUCH PRODUCT
, TO THE FULLEST EXTENT THAT ANY SUCH LOSS OR
DAMAGE MAY BE DISCLAIMED BY LAW
.
THIS WARRANTY SHALL BECOME NULL AND VOID IN THE EVENT OF A VIOLATION OF THE PROVISIONS OF THIS LIMITED WARRANTY
.
Page 45
Technical Support
AC-425 Hardware Installation and User Guide
Page 45
Appendix. B Technical Support
Asia Pacific, Middle East, Africa
Rosslare Security Products Headquarters 905-912 Wing Fat Industrial Bldg 12 Wang Tai Road, Kowloon Bay Hong Kong Tel: +852 2795-5630 Fax: +852 2795-1508
support.apac@rosslaresecurity.com
United States and Canada
1600 Hart Court, Suite 103 Southlake, TX, USA 76092 Toll Free: +1-866-632-1101 Local: +1-817-305-0006 Fax: +1-817-305-0069
support.na@rosslaresecurity.com
Europe
Global Technical S upport & Training Center HaMelec ha 22 Rosh HaAyin, Israel 48091 Tel: +972 3 938-6838 Fax: +972 3 938-6830
support.eu@rosslaresecurity.com
South America
Presbitero Actis 567 Of. 31 San Isidro Buenos Aires, Argentina 1642 Tel: + 54 11 5273 6383 Fax: +54 11 4763 6505
support.la@rosslaresecurity.com
India
Rosslare Security Indi a Ltd. 707, High Land 4, Akurli Road, Lokhandwala Township, Kandivali (East), Mumbai – 400101 Tel: +0091 22 2966 1130 Fax: +0091 22 2966 1130
support.in@rosslaresecurity.com
China
Beijing Office Room 1408, 14F, Building 315 Huizhong North Road, Ch aoyang District Beijing, Chin a Tel: +86 10 64808945
support.cn@rosslaresecurity.com
Shanghai Office Room K, 19 F, Ladoll Build ing 831 Xinzha Road, Jing’an, District Shanghai, China Tel: +86 21 32313299
support.cn@rosslaresecurity.com
Website: www.rosslaresecurity.com
Page 46