Rosslare AC-225-X Hardware Installation And User's Manual

0706-0960202+02
www.rosslaresecurity.com
Advanced Scalable Networked Access Controller
Hardware Installation and User Guide
May 2010
Table of Contents
AC-225-X
Advanced Scalable Networked Access Controller2
1. Introduction ..................................................................... 3
1.1 Features ............................................................................. 5
1.2 AxTrax AS-525 ..................................................................... 5
1.3 Compatible Readers ......................................................... 6
2. Technical Specifications .................................................. 7
3. AC-225 Panel Set-Up ..................................................... 10
3.1 Inputs Wiring – Non-Supervised Inputs ............................. 11
3.2 Inputs Wiring – Supervised Inputs ..................................... 11
3.3 Outputs Wiring .................................................................. 11
3.4 Power Supply ................................................................... 13
3.5 Reader ............................................................................. 15
3.6 MD-IO84 .......................................................................... 15
3.7 MD-D02............................................................................ 15
4. Input and Output Connections ....................................... 17
4.1 Input Types ....................................................................... 17
4.2 Inputs Description ............................................................ 22
4.3 Outputs ............................................................................ 24
4.4 Card Readers and Keypads ............................................ 24
5. AC-225 Hardware Settings.............................................. 26
5.1 DIP Switch Configuration .................................................. 28
5.2 Access Control Panel Baud Rate ..................................... 29
5.3 Access Control Panel Type .............................................. 29
5.4 Access Control Panel Addressing .................................... 30
6. Communications .......................................................... 32
6.1 Serial Network Connection .............................................. 32
6.2 TCP/IP Network Connection ............................................. 34
6.3 Modem Network Connection .......................................... 36
Appendix A. Limited Warranty ........................................... 38
Appendix B. Technical Support ......................................... 40
Introduction
AC-225 Hardware Installation and User Guide
Page 3
1. Introduction
AC-225, AC-225IP and AC-225IPU access control panels are state-of-the­art networked access controllers, employing the latest technology to meet the requirements of the market.
When used in combination with Rosslare's AxTrax software system, the AC­225 gives you full control over access to your premises. The system can control both single and double door entrances and up to four doors, with MD-D02 two Door expansion module. AC-225 supports up to 30,000 users and uses flash memory to enable easy firmware upgrades.
For more information on the AxTrax AS-525 system, refer to the AxTrax Access Control Software Manual.
The AC-225 consists of the following components:
AC-225 controller board
Panel enclosure
PS-33 power supply
Power Transformer (not included with the AC-225IPU)
• 4 x 2.2k Ohm and 4 x 8.2k Ohm resistors for the supervised inputs.
The AC-225IPU also includes on-board support for communications across a TCP/IP network.
The AC-225U and AC-225IPU are for US installations, and have been approved by UL for use as a stand-alone unit only.
Introduction
AC-225 Hardware Installation and User Guide
Page 4
Figure 1: AC-225 panel
Introduction
AC-225 Hardware Installation and User Guide
Page 5
1.1 Features
The AC-225 is a powerful and adaptable access control solution with a range of powerful features.
Controls 1-2 doors (DIP switch controlled) or 2-4 doors when optional
MD-D02 installed
• Two IN/OUT readers, with tamper switch and LED control
Four inputs, selectable as supervised or non-supervised
Form-C relay outputs (rated 5A)
Optional MD-IO84 with an additional 4 relay outputs and 8 inputs,
selectable as supervised or non-supervised
Optional MD-D02 with 2 readers, 4 relay outputs, and 4 inputs
selectable as supervised or non-supervised
Built-in sounder generator for chime, bell and siren signals
• Panel configuration DIP switch
Up to 32 access control panels in every network (64 doors in every
network or 128 door network when optional MD-D02 installed)
• 30,000 users
20,000 log events
RS-232 or RS-485 serial communication (up to 115200 bps)
On-board TCP/IP communication (AC-225IP only)
• Remote firmware upgrades
• Removable terminal blocks
1.2 AxTrax AS-525
The AxTrax AS-525 software system is custom designed to set-up, manage and supervise all aspects of a access panel network.
It offers the following capabilities:
Users capacity
30000
Unauthorized Users
30000
Access groups
30000
Number of panels in system 1023 Number of doors in system 4092
Note:
These options are software and firmware dependent, and may change in later releases or revisions.
Client-Server Structure
AxTrax AS-525 operates through a dedicated AxTrax server computer, which communicates with the access control panels and can serve an unlimited number of network clients.
Introduction
AC-225 Hardware Installation and User Guide
Page 6
The server also runs the system's SQL database, which contains settings and definitions for access control across the entire facility. Clients can define new employees and control access permissions. The system includes tools for database backup, input and export of previous configurations and automatic backing-up on a periodic basis.
AxTrax AS-525 supports all panel types and offers scalability and flexibility in addition to a range of advanced control features.
Configurable Links
The system's configurable links model makes it possible to trigger any chosen output automatically or report a configurable alarm, based on a selected input. This allows easy integration with other access systems such as intruder alarms, CCTV systems and elevator controls.
AxTrax AS-525 can also define a selected set of operations (defined in configurable links) when a panel registers a specified user or group of users. This can be useful, for example, in elevator control systems. The system can assign users with counters, allowing a limited number of entries to each panel.
Fingerprint Recognition
AxTrax can share user details with Rosslare's BioTrax software system. The BioTrax system can then download all selected users information to an AYC-W6500 fingerprint reader.
Note: Fingerprint recognition was not evaluated by UL.
1.3 Compatible Readers
For UL-compliant installations, use any of the following UL-listed PIN and PROX card readers made by Rosslare:
AY-H12, AY-J12, AY-K12, AY-L12, AY-M12, AY-Q12, AYC-F54, AYC-F64, AYC­G54, AYC-G64, AYC-Q54B, or AYC-Q64B
Technical Specifications
AC-225 Hardware Installation and User Guide
Page 7
2. Technical Specifications
Electrical Characteristics
Operating Voltage
13.8V DC 1.5A from PS-33
Maximum Input Current
AC-225: Standby: 80mA
Maximum: 325mA
AC-225IP: Standby: 120mA
Maximum: 370mA
General Inputs
4 supervised high impedance inputs.
8 or 12 supervised inputs when using MD-D02 or MD-IO84 expansion boards
Maximum voltage: 5V DC
Relay Outputs
4 Relay outputs 8 supervised outputs when using MD­D02 or MD-IO84 expansion boards
5A Relay N.O. and N.C. options
Reader Ports
Standard = 2 Reader ports
With MD-D02 = 4 Reader ports Output voltage: 12V DC Max. Current: 245mA LED control output D0/D1, tamper
input
Visual Indicators
11 LEDs
Audio
Built in sounder (bell, chime and siren)
Battery Standby Time
3 hours (for w/12V battery
Communication Characteristics
RS-232
Terminal Block
RS-485
Molex and Terminal Block
TCP/IP
On-board RJ-45 connector
(AC-225IP and AC-225IPU have an
internal IP module)
Speed Options
9600 bps
19200 bps 57600 bps
115200 bps
Technical Specifications
AC-225 Hardware Installation and User Guide
Page 8
Environmental Characteristics
Operating Temperature Range
32°F - 120°F (0°C - 49°C)
Operating Humidity
0 - 85% (Non-condensing)
Dimensions
Height x Width x Depth
10.4 x 13.2 x 3.4 inch 264 x 334 x 84.5 mm
Weight
AC-225 8.38 lbs. (3.80 Kg)
AC-225IP
8.40 lbs. (3.81 Kg)
AC-225U
5.95 lbs. (2.70 Kg)
AC-225IPU
5.97lbs. (2.71Kg)
Transformer (for AC-225 and AC-225IP models only)
AC Transformer
AC transformer 120/220V AC / 16V AC 3A (50VA),class 2 (not included)
PS-33 Power Supply Specifications
Input Voltage
16.5V AC/3A
Backup Battery Charger Output
12VDC/300mA
To Access control panel ­Output Voltage 1
13.8V DC / 1.5A
To Relay Outputs
Output Voltage 2
13.8V DC/ 0.9A
PS-33 Power Supply Indication
Tamper Output
(open collector)
Indicates faulty power
Technical Specifications
AC-225 Hardware Installation and User Guide
Page 9
PS-33 Power LEDs
Power In (AC) Green LED1
Main power
Power Out (DC) Red LED2
Low voltage
Low Battery
Red LED3
Backup battery low voltage
Note:
For models: AC-225U and AC-225IPU These models come without a transformer. When using a third-party transformer, please make sure that it is rated for at least 50W (16.5 VAC @ 3A). AC-225U and AC-225IPU have a maximum 50Wpower­consumption, which means that it requires 3.0A. This rated power is divided in the system, as follows:
1) 300 mA for the Lead Acid Battery Charger
2) 980mA total for four readers (when MD-D02 is used)
3) 900mA total for the four outputs In cases where the installation requires more power (for example high rated magnetic locks) we recommend using
an external power supply for the lock.
Note:
UL-listed panic hardware must be used to allow emergency exit from the protected area.
AC-225 Panel Set-Up
AC-225 Hardware Installation and User Guide
Page 10
3. AC-225 Panel Set-Up
Every AC-225 panel controls one or two doors (up to 4 doors with MD­D02). The panels connect together in a network and are controlled by a central server computer, running the AS-525 AxTrax software system.
The following diagram shows an example set-up for a network of AC-225 access control panels.
Figure 2: Sample AC-225 Configuration
Note:
The use of bushings is required for any conductors leaving the enclosure through the provided openings.
AxTrax Software
Door 1
Door 3
Door 2
Door 4
Reader,
Keypad
and Door
Release
Reader
Reader,
Keypad
and Door
Release
Exit
Button
Exit
Button
2 Readers
for Reader
In and
Reader
Out
AC-225
Single
Door
AC-225
Single
Door
AC-225
Double
Door
RS-485/232
Converter
RS-232 RS-485
RS-485
RS-485
Up to
32
Access control panels
AC-225
Single
Door
AC-225 Panel Set-Up
AC-225 Hardware Installation and User Guide
Page 11
3.1 Inputs Wiring – Non-Supervised Inputs
Figure 3: Inputs Wiring – Non-supervised Inputs
3.2 Inputs Wiring – Supervised Inputs
When wiring the AC-225 for supervised inputs, resistors should be placed on the input switch and not on the terminal block.
For further details refer to Input and Output Connections on page 17.
3.3 Outputs Wiring
The following diagram illustrates wiring for two main types of 12VDC electrical release mechanisms. Other electrical devices can be switched using the voltage free relay contacts.
AC-225 Panel Set-Up
AC-225 Hardware Installation and User Guide
Page 12
Figure 4: Door Lock – Failed Close