Rosslare AC-225E, AC-225IPU, AC-225L, AC-225IPL, AC-225IP PCBA Hardware Installation Manual

...
AC-225x Series
Advanced Scalable Networked Access Controllers
Hardware Installation Manual
Models:
AC-225E, AC-225IPU AC-225U, AC-225IPU AC-225L, AC-225IPL AC-225 PCBA, AC-225IP PCBA
Copyright © 2017 by Rosslare. All rights reserved.
This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
Table of Contents
AC-225x Series Hardware Installation Manual iii
Table of Contents
1. Introduction ................................................................................ 8
1.1 AxTraxNG ........................................................................................... 9
1.1.1 Client-Server Structure ............................................................................... 10
1.1.2 Configurable Links ..................................................................................... 10
1.1.3 Fingerprint Recognition .............................................................................. 10
1.1.4 Compatible Readers .................................................................................. 10
2. Technical Specifications ........................................................... 11
3. AC-225x Panel Setup ................................................................ 13
3.1 Inputs Wiring – Non-Supervised Inputs .............................................. 14
3.2 Inputs Wiring – Supervised Inputs ..................................................... 14
3.3 Outputs Wiring ................................................................................. 15
3.4 Power Supply .................................................................................... 17
3.5 AC-225x Wiring Communications ..................................................... 17
3.6 Reader .............................................................................................. 18
3.7 MD-IO84 .......................................................................................... 19
3.8 MD-D02 ........................................................................................... 19
4. Input and Output Connections ................................................ 20
4.1 Input Types ....................................................................................... 20
4.1.1 Normally Open Input Connection ............................................................... 20
4.1.2 Normally Closed Input Connection ............................................................. 21
4.1.3 Normally Open Supervised Single Resistor Input Connection........................ 22
4.1.4 Normally Open Supervised Double Resistor Input Connection ...................... 22
4.1.5 Normally Closed Supervised Single Resistor Input Connection ...................... 23
4.1.6 Normally Closed Supervised Double Resistor Input Connection .................... 24
4.2 Inputs Description ............................................................................. 24
4.2.1 Request to Exit Button (REX) Input .............................................................. 24
4.2.2 Door Monitor Input ................................................................................... 25
4.2.3 General Purpose Inputs .............................................................................. 25
4.3 Outputs ............................................................................................ 26
Table of Contents
iv AC-225x Series Hardware Installation Manual
4.4 Card Readers and Keypads ................................................................ 26
5. AC-225x Hardware Settings ..................................................... 28
5.1 DIP Switch Configuration .................................................................. 30
5.2 Access Control Panel Baud Rate ........................................................ 30
5.3 Access Control Panel Type ................................................................ 31
5.4 Access Control Panel Addressing ....................................................... 31
6. Communications ....................................................................... 33
6.1 Serial Network Connection ............................................................... 33
6.1.1 RS-232 Connection to the Computer ......................................................... 33
6.1.2 RS-485 Connection to the Computer ......................................................... 34
6.1.3 Daisy Chaining .......................................................................................... 34
6.2 TCP/IP Network Connection .............................................................. 35
6.2.1 LAN and WAN Requirements ..................................................................... 35
6.3 Modem Network Connection ............................................................ 36
6.3.1 Hardware Requirements ............................................................................ 36
6.3.2 Prerequisites .............................................................................................. 37
6.3.3 Computer Connections .............................................................................. 37
6.3.4 AC-225x Panel Connections....................................................................... 37
A. Limited Warranty...................................................................... 38
List of Figures
AC-225x Series Hardware Installation Manual v
List of Figures
Figure 1: AC-225x Panel ................................................................................. 9
Figure 2: Sample AC-225x Configuration...................................................... 13
Figure 3: Inputs Wiring – Non-supervised Inputs ........................................... 14
Figure 4: Door Lock – Failed Close ................................................................ 15
Figure 5: Door Lock – Failed Open ................................................................ 16
Figure 6: Wiring Between PS-33 and AC-225x .............................................. 17
Figure 7: AC-225x Wiring Communications .................................................. 17
Figure 8: Reader Wiring ................................................................................ 18
Figure 9: Connector Location for MD-IO84 or MD-D02 ................................. 19
Figure 10: Normally Open Input Connection ................................................. 21
Figure 11: Normally Closed Input Connection ............................................... 21
Figure 12: Normally Open Supervised Input (Single Resistor) .......................... 22
Figure 13: Normally Open Supervised Input (Double Resistor) ........................ 23
Figure 14: Normally Closed Supervised Input (Single Resistor) ........................ 23
Figure 15: Normally Closed Supervised Input (Double Resistor) ...................... 24
Figure 16: DIP Switch ................................................................................... 30
Figure 17: DIP Switch with Baud Rate Setting ............................................... 31
Figure 18: DIP Switch for Door Setting .......................................................... 31
Figure 19: DIP Switch with Internal Network Address Setting ........................ 31
Figure 20: Daisy Chaining ............................................................................. 34
Figure 21: MD-N32 Configuration Connecting a Single Panel ....................... 35
Figure 22: Connecting Multiple Access Control Panels with MD-N32 ............ 36
Figure 23: Connecting Multiple Access Control Panels with AC-225x ............ 36
Figure 24: Remote Site Modem Configuration .............................................. 36
List of Tables
vi AC-225x Series Hardware Installation Manual
List of Tables
Table 1: Description of Family of AC-225 and AC-225IP Panels ....................... 8
Table 2: AxTraxNG Capabilities ....................................................................... 9
Table 3: Possible Hardware Settings .............................................................. 28
Table 4: DIP Switches and Their Functions ..................................................... 30
Table 5: Switch Baud Rates ........................................................................... 31
Table 6: Available Panel Addresses ............................................................... 32
Table 7: RS-232 Connection ......................................................................... 33
Notice and Disclaimer
AC-225x Series Hardware Installation Manual vii
Notice and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein.
B
EFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND
THE USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY
REQUIREMENTS AND OPERATING PROCEDURES
.
The system must not be used for purposes other than those for which it
was designed.
The use of the software associated with the system and/or product, if
applicable, is subject to the terms of the license provided as part of the purchase documents.
ROSSLARE exclusive warranty and liability is limited to the warranty and
liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with the
maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively
maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury.
The text, images and graphics contained in the manual are for the
purpose of illustration and reference only.
All data contained herein subject to change without prior notice. In no event shall manufacturer be liable for any special, direct, indirect,
incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury).
All graphics in this manual are for reference only, some deviation between
the image(s) and the actual product may occur.
All wiring diagrams are intended for reference only, the photograph or
graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s).
Introduction
8 AC-225x Series Hardware Installation Manual
1. Introduction
The AC-225 and AC-225IP family of access control panels are state-of-the-art networked access controllers, employing the latest technology to meet the requirements of the market.
Table 1 summarizes the family of AC-225 and AC-225IP models and their respective descriptions.
Table 1: Description of Family of AC-225 and AC-225IP Panels
Model Name Description
AC-225-E AC-225, no onboard IP, supplied with 230 VAC
transformer
AC-225-U AC-225, no onboard IP, FCC approved and UL-294 listed,
Transformer Not Supplied
AC-225-L AC-225, no onboard IP, supplied with 110 VAC
transformer
AC-225-PCBA AC-225, no onboard IP, PCB only AC-225IP-E AC-225IP with onboard IP, supplied with 230 VAC
transformer
AC-225IP-U AC-225IP with onboard IP, FCC approved and UL-294
listed, transformer not supplied
AC-225IP-L AC-225IP with onboard IP, supplied with 110 VAC
transformer
AC-225IP-PCBA AC-225IP with onboard IP, PCB only
The IP models also includes onboard support for communications across a TCP/IP network.
The U models are for US installations, and have been approved by UL for use as standalone units only.
When used in combination with Rosslare's AxTraxNG™ software system, the AC-225x gives you full control over access to your premises. The system can control both single and double door entrances and up to four doors, with MD­D02 two Door expansion module. AC-225x supports up to 30,000 users and uses flash memory to enable easy firmware upgrades. For more information on the AxTraxNG system, refer to the
AxTraxNG™ Software Installation and User
Manual
.
The AC-225x consists of the following components:
AC-225x controller board Panel enclosure PS-33 power supply Power Transformer (as described in Table 1) 4 x 2.2 kΩ and 4 x 8.2 kΩ resistors for the supervised inputs.
Introduction
AC-225x Series Hardware Installation Manual 9
Figure 1 shows the general layout of the AC-225x panel.
Figure 1: AC-225x Panel
1.1 AxTraxNG
The AxTraxNG software system is custom designed to set up, manage, and supervise all aspects of an access panel network.
Table 2 presents the AxTraxNG software capabilities:
Table 2: AxTraxNG Capabilities
Users capacity 30000 Unauthorized Users 30000
Access groups 30000 Number of panels in system 1023 Number of doors in system 4092
These options are software and firmware dependent, and may change in later releases or revisions.
Introduction
10 AC-225x Series Hardware Installation Manual
1.1.1 Client-Server Structure
AxTraxNG operates through a dedicated AxTrax server computer, which communicates with the access control panels and can serve an unlimited number of network clients.
The server also runs the system's SQL database, which contains settings and definitions for access control across the entire facility. Clients can define new employees and control access permissions. The system includes tools for database backup, input and export of previous configurations and automatic backing-up on a periodic basis.
AxTraxNG supports all panel types and offers scalability and flexibility in addition to a range of advanced control features.
1.1.2 Configurable Links
The system's configurable links model makes it possible to trigger any chosen output automatically or report a configurable alarm, based on a selected input. This allows easy integration with other access systems such as intruder alarms, CCTV systems and elevator controls.
AxTraxNG can also define a selected set of operations (defined in configurable links) when a panel registers a specified user or group of users. This can be useful, for example, in elevator control systems. The system can assign users with counters, allowing a limited number of entries to each panel.
1.1.3 Fingerprint Recognition
AxTrax can share user details with Rosslare's BioTrax software system. The BioTrax system can then download all selected users information to an AYC­W6500 fingerprint reader.
Fingerprint recognition was not evaluated by UL.
1.1.4 Compatible Readers
For UL-compliant installations, use any of the following UL-listed PIN and PROX card readers made by Rosslare: AY-H12, AY-J12, AY-K12, AY-L12, AY-M12, AY-Q12, AYC-F54, AYC-F64, AYC-G54, AYC-G64, AYC-Q54B, or AYC-Q64B.
Technical Specifications
AC-225x Series Hardware Installation Manual 11
2. Technical Specifications
Electrical Characteristics
Operating Voltage
13.8 VDC 1.5 A from PS-33
Maximum Input Current
AC-225 Standby: 80 mA
Maximum: 325 mA
AC-225IP Standby: 120 mA
Maximum: 370 mA
General Inputs
4 supervised high impedance inputs. 8 or 12 supervised inputs when using MD-D02
or MD-IO84 expansion boards Maximum voltage: 5 VDC
Relay Outputs
4 Relay outputs 8 supervised outputs when using MD-D02 or
MD-IO84 expansion boards 5 A Relay N.O. and N.C. options
Reader Ports
Standard: 2 reader ports With MD-D02: 4 reader ports Output voltage: 12 VDC Max. current: 245 mA LED control output D0/D1, tamper input
Visual Indicators
11 LEDs
Audio
Built in sounder (bell, chime and siren)
Battery Standby Time
3 hours (for w/12V battery
Communication Characteristics
RS-232
Terminal Block
RS-485
Molex and Terminal Block
TCP/IP
Onboard RJ-45 connector (AC-225IP and AC-225IPU have an internal IP
module)
Speed Options
9600 bps 19200 bps 57600 bps 115200 bps
Environmental Characteristics
Operating Temperature Range
0°C to 49°C (32°F to 120°F)
Operating Humidity Range
0 to 85% (non-condensing)
Technical Specifications
12 AC-225x Series Hardware Installation Manual
Dimensions
Height x Width x Depth
264 x 334 x 84.5 mm (10.4 x 13.2 x 3.4 in.)
Weight
AC-225 4.0 kg (8.7 lb) AC-225IP 3.8 kg (8.4 lb)
AC-225U 2.7 kg (5.8 lb) AC-225IPU 2.7 kg (5.8 lb)
Transformer (for IP models only)
AC Transformer
AC transformer 120/220 VAC/16 VAC 3A (50 VA), class 2 (not included)
PS-33 Power Supply Specifications
Input Voltage
16.5 VAC, 3 A
Backup Battery Charger Output
12 VDC, 300 mA
To access control panel – Output Voltage 1
13.8 VDC, 1.5 A
To Relay Outputs – Output Voltage 2
13.8 VDC, 0.9 A
PS-33 Power Supply Indication
Tamper Output (open collector)
Indicates faulty power
PS-33 Power LEDs
Power In (AC) – Green LED1
Main power
Power Out (DC) – Red LED2
Low voltage
Low Battery – Red LED3
Backup battery low voltage
For models: AC-225U and AC-225IPU These models come without a transformer. When using a third-party
transformer, please make sure that it is rated for at least 50 W (16.5 VAC @ 3A).
AC-225U and AC-225IPU have a maximum 50 W power consumption, which means that it requires 3.0 A. This rated power is divided in the system, as follows:
1) 300 mA for the Lead Acid Battery Charger
2) 980 mA total for four readers (when MD-D02 is used)
3) 900 mA total for the four outputs
In cases where the installation requires more power (for example high rated magnetic locks), we recommend using an external power supply for the lock.
UL listed panic hardware must be used to allow emergency exit from the protected area.