Rosslare AC-215-Bx, AC-215-DIN, AC-215IP-DIN, AC-215IP-Bx Installation Manual And User's Manual

AC-215x-B Series
2-Reader Networked Access Control Panel
Hardware Installation Manual and User Guide
Models:
AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN
Copyright © 2018 by Rosslare. All rights reserved.
This manual and the information contained herein are proprietary to ROSSLARE ENTERPRISES LIMITED and/or its related companies and/or subsidiaries’ (hereafter: "ROSSLARE"). Only ROSSLARE and its customers have the right to use the information.
No part of this manual may be re-produced or transmitted in any form or by any means, electronic or mechanical, for any purpose, without the express written permission of ROSSLARE.
ROSSLARE owns patents and patent applications, trademarks, copyrights, or other intellectual property rights covering the subject matter in this manual.
TEXTS, IMAGES, AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE. THEIR USE, REPRODUCTION, AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS.
The furnishing of this manual to any party does not give that party or any third party any license to these patents, trademarks, copyrights or other intellectual property rights, except as expressly provided in any written agreement of ROSSLARE.
ROSSLARE reserves the right to revise and change this document at any time, without being obliged to announce such revisions or changes beforehand or after the fact.
Table of Contents
AC-215x-B Series Hardware Installation Manual iii
Table of Contents
1. Introduction ................................................................................ 8
1.1 AxTraxNG ........................................................................................... 9
1.1.1 Client-Server Structure ............................................................................... 10
1.1.2 Configurable Links ..................................................................................... 10
2. Technical Specifications ........................................................... 11
2.1 AC-215x-DIN .................................................................................... 11
2.2 AC-215x Installed in ME-1015 .......................................................... 12
3. AC-215x Panel Setup ................................................................ 13
3.1 Inputs Wiring – Non-Supervised Inputs .............................................. 14
3.2 Inputs Wiring – Supervised Inputs ..................................................... 14
3.3 Outputs Wiring ................................................................................. 15
3.4 Power Supply .................................................................................... 17
3.5 AC-215x-B Wiring Communications .................................................. 18
3.6 Reader .............................................................................................. 19
4. Input and Output Connections ................................................ 20
4.1 Input Types ....................................................................................... 20
4.1.1 Normally Open Input Connection ............................................................... 20
4.1.2 Normally Closed Input Connection ............................................................. 21
4.1.3 Normally Open Supervised Single Resistor Input Connection........................ 22
4.1.4 Normally Open Supervised Double Resistor Input Connection ...................... 22
4.1.5 Normally Closed Supervised Single Resistor Input Connection ...................... 23
4.1.6 Normally Closed Supervised Double Resistor Input Connection .................... 24
4.2 Inputs Description ............................................................................. 24
4.2.1 Request-to-Exit Button (REX) Input ............................................................. 24
4.2.2 Door Monitor Input ................................................................................... 25
4.2.3 General Purpose Inputs .............................................................................. 25
4.3 Outputs ............................................................................................ 25
4.4 Card Readers and Keypads ................................................................ 26
5. AC-215x Hardware Settings ..................................................... 27
Table of Contents
iv AC-215x-B Series Hardware Installation Manual
5.1 DIP Switch Configuration .................................................................. 27
5.2 Access Control Panel Baud Rate ........................................................ 27
5.3 Access Control Panel Type ................................................................ 28
5.4 Access Control Panel Addressing ....................................................... 29
6. Communications ....................................................................... 31
6.1 Serial Network Connection ............................................................... 31
6.1.1 RS-232 Connection to the Computer ......................................................... 31
6.1.2 RS-485 Connection to the Computer ......................................................... 32
6.1.3 Daisy Chaining .......................................................................................... 33
6.2 TCP/IP Network Connection .............................................................. 34
6.2.1 LAN and WAN Requirements ..................................................................... 34
A. Declaration of Conformity....................................................... 36
B. Radio Equipment Directive (RED) ............................................ 37
C. RoHS Directive .......................................................................... 38
D. Limited Warranty...................................................................... 39
List of Figures
AC-215x-B Series Hardware Installation Manual v
List of Figures
Figure 1: AC-215x Panel ................................................................................. 9
Figure 2: Sample AC-215x Configuration...................................................... 13
Figure 3: Inputs Wiring – Non-supervised Inputs ........................................... 14
Figure 4: Door Lock – Failed Close ................................................................ 15
Figure 5: Door Lock – Failed Open ................................................................ 16
Figure 6: Wiring Between PM-10 and AC-215x-B ......................................... 17
Figure 7: AC-215x-B Wiring Communications ............................................... 18
Figure 8: Reader Wiring ................................................................................ 19
Figure 10: Normally Open Input Connection ................................................. 21
Figure 11: Normally Closed Input Connection ............................................... 21
Figure 12: Normally Open Supervised Input (Single Resistor) Connection ....... 22
Figure 13: Normally Open Supervised Input (Double Resistor) Connection ..... 23
Figure 14: Normally Closed Supervised Input (Single Resistor) Connection ..... 23
Figure 15: Normally Closed Supervised Input (Double Resistor) Connection ... 24
Figure 16: DIP Switches ................................................................................ 27
Figure 17: RS-232 Panel Connection to PC ................................................... 31
Figure 18: RS-485 Panel Connection to PC ................................................... 32
Figure 19: Daisy Chaining ............................................................................. 33
Figure 20: Connecting Multiple Access Control Panels to AC-215IP .............. 34
Figure 21: Connecting a Single Control Panel with MD-N32 ......................... 34
Figure 22: Connecting Multiple Access Control Panels with MD-N32 ............ 35
List of Tables
vi AC-215x-B Series Hardware Installation Manual
List of Tables
Table 1: Description of AC-215x-B Panels ....................................................... 8
Table 2: AxTraxNG Capabilities ....................................................................... 9
Table 3: DIP Switches and Their Functions ..................................................... 27
Table 4: Switch Baud Rates ........................................................................... 28
Table 5: Possible Hardware Settings .............................................................. 28
Table 6: Available Panel Addresses ............................................................... 29
Table 7: RS-232 Connection ......................................................................... 32
Notice and Disclaimer
AC-215x-B Series Hardware Installation Manual vii
Notice and Disclaimer
This manual’s sole purpose is to assist installers and/or users in the safe and efficient installation and usage of the system and/or product, and/or software described herein.
B
EFORE ATTEMPTING TO INSTALL AND/OR USE THE SYSTEM, THE INSTALLER AND
THE USER MUST READ THIS MANUAL AND BECOME FAMILIAR WITH ALL SAFETY
REQUIREMENTS AND OPERATING PROCEDURES
.
The system must not be used for purposes other than those for which it
was designed.
The use of the software associated with the system and/or product, if
applicable, is subject to the terms of the license provided as part of the purchase documents.
ROSSLARE exclusive warranty and liability is limited to the warranty and
liability statement provided in an appendix at the end of this document.
This manual describes the maximum configuration of the system with the
maximum number of functions, including future options. Therefore, not all functions described in this manual may be available in the specific system and/or product configuration you purchased.
Incorrect operation or installation, or failure of the user to effectively
maintain the system, relieves the manufacturer (and seller) from all or any responsibility for consequent noncompliance, damage, or injury.
The text, images and graphics contained in the manual are for the
purpose of illustration and reference only.
All data contained herein subject to change without prior notice. In no event shall manufacturer be liable for any special, direct, indirect,
incidental, consequential, exemplary or punitive damages (including, without limitation, any and all damages from business interruption, loss of profits or revenue, cost of capital or loss of use of any property or capital or injury).
All wiring diagrams are intended for reference only, the photograph or
graphic of the PCB(s) are intended for clearer illustration and understanding of the product and may differ from the actual PCB(s).
Introduction
8 AC-215x-B Series Hardware Installation Manual
1. Introduction
In this manual, unless otherwise stated, “AC-215x-B” refers to both the regular AC-215-B and the AC-215IP-B moels
The AC-215x-B series of access control panels are networked access controllers, employing the latest technology to meet the requirements of the market.
Table 1 summarizes the AC-215x-B models and their respective descriptions.
Table 1: Description of AC-215x-B Panels
Model Name Description
AC-215-BA Installed in ME-1015 with Type I plug power cable, RS-485
connection
AC-215-BB Installed in ME-1015 with Type G plug power cable, RS-485
connection
AC-215-BE Installed in ME-1015 with Type F plug power cable, RS-485
connection
AC-215-BU Installed in ME-1015 with Type B plug power cable, RS-485
connection
AC-215-DIN PCBA only with wall /DIN rail mounting base, RS-485 connection
AC-215IP-BA Installed in ME-1015 with Type I plug power cable, TCP/IP
connection
AC-215IP-BB Installed in ME-1015 with Type G plug power cable, TCP/IP
connection
AC-215IP-BE Installed in ME-1015 with Type F plug power cable, TCP/IP
connection
AC-215IP-BU Installed in ME-1015 with Type B plug power cable, TCP/IP
connection
AC-215IP-DIN PCBA only with wall /DIN rail mounting base, TCP/IP connection
The IP models also includes onboard support for communications across a TCP/IP network.
When used in combination with Rosslare's AxTraxNG™ software system, the AC-215x gives you full control over access to your premises. The system can control both single and double door entrances and up to two doors. AC-215x supports up to 30,000 users and uses flash memory to enable easy firmware upgrades. For more information on the AxTraxNG system, refer to the
AxTraxNG™ Software Installation and User Manual
.
The AC-215x comes either as a PCBA “DIN” module that can be wall or DIN rail mountable, or pre-assembled within the ME-1015 power management enclosure. The ME-1015 contains a universal switch mode power supply that
Introduction
AC-215x-B Series Hardware Installation Manual 9
accepts inputs from 90 ~ 265 VAC (50 ~ 60 Hz) and outputs 60 watts, a power management board that provides two independently fused 12 VDC, 2 Amp power outputs – one for the controller and readers, and one for locks. The ME-1015 power management enclosure also includes an alert sounder, a lead acid battery charger for a lead acid battery of up 12 V and 7 Ah, and an intelligent light bar that provides enclosure lighting, an enclosure tamper sensor, and a power status LED indicator.
Figure 1 shows the general layout of the AC-215x panel.
Figure 1: AC-215x Panel
1.1 AxTraxNG
The AxTraxNG software system is designed to set up, manage, and supervise all aspects of an access control panel network.
Table 2 presents the AxTraxNG software capabilities:
Table 2: AxTraxNG Capabilities
Users capacity
30,000 Unauthorized Users 30,000 Access groups 30,000
Number of panels in system 1,023 Number of doors in system 4,092
Introduction
10 AC-215x-B Series Hardware Installation Manual
These options are software and firmware dependent, and may change in later releases or revisions.
1.1.1 Client-Server Structure
AxTraxNG operates through a dedicated AxTrax server computer, which communicates with the access control panels and can serve an unlimited number of network clients.
The server also runs the system's SQL database, which contains settings and definitions for access control across the entire facility. Clients can define new employees and control access permissions. The system includes tools for database backup, input and export of previous configurations and automatic backing-up on a periodic basis.
1.1.2 Configurable Links
The system's configurable links model makes it possible to trigger any chosen output automatically or report a configurable alarm, based on a selected input. This allows easy integration with related access systems such as intruder alarms, CCTV systems and elevator controls.
AxTraxNG can also define a selected set of operations (defined in configurable links) when a panel registers a specified user or group of users. This can be useful, for example, in elevator control systems. The system can assign users with counters, allowing a limited number of entries to each panel.
Technical Specifications
AC-215x-B Series Hardware Installation Manual 11
2. Technical Specifications
2.1 AC-215x-DIN
Electrical Characteristics
Operating Voltage
12 VDC, 1.5 A from a regulated power supply
Maximum Input Current
AC-215 Standby: 80 mA
Maximum: 325 mA
AC-215IP Standby: 120 mA
Maximum: 370 mA
General Inputs
• 4 supervised high impedance inputs
• Maximum voltage: 5 VDC
Relay Outputs
4 Form C 5 Amp relay outputs
Reader Ports
• 2 reader ports
Communication: Wiegand (D0, D1) or Clock &
Data (C, D)
• Output voltage to reader: 12 VDC
• Max. current to reader: 245 mA
• LED control output and Tamper Input
Visual Indicators
11 LEDs for outputs and communication status
Audio
Sounder output for use with compatible speakers provide chime, bell and siren signals
Battery Standby Time
3 hours with a 12 V, 7 Ah lead acid battery
Communication Characteristics
RS-485 / RS-232
RS-485 or optional RS-232
RS-485 connection by terminal block or MD-14U
connector
• RS-232 connection by terminal block
RS-232
Terminal Block
RS-485
Molex and Terminal Block
TCP/IP
On-board RJ-45 connector (functional on AC-215IP models only)
Selectable Communication Speed
9600, 19200, 57600, 115200 bps
Environmental Characteristics
Operating Temperature Range
0°C to 49°C (32°F to 120°F)
Operating Humidity Range
0 to 85% (non-condensing)
Dimensions
Height x Width x Depth
193 x 136.5 x 39 mm (7.6 x 5.4 x 1.5 in.)
Technical Specifications
12 AC-215x-B Series Hardware Installation Manual
Weight
0.36 kg (12.7 oz)
2.2 AC-215x Installed in ME-1015
Electrical Characteristics – Switch Mode Power Supply
Operating Voltage
90 ~ 265 VAC, 50 ~ 60 Hz from mains power
Maximum Input Current
1.5 A
Output Power
15 VDC, 4 A (60 Watts) to the power management board
Electrical Characteristics – Power Management Board (PM-10)
Input Power
15 VDC, 4 A to the power management board
Output Power
Two PTC fused outputs, each provides 13.8 VDC, 2 A
One output for controller and readers One output for locks
Battery Charger
13.8 VDC, 300 mA for 12VDC, 7Ah Lead Acid Battery
Speaker
0.5 Watt, 8 Ohm
Light Bar
0.3 Watt for LED light
Environmental Characteristics
Operating Temperature Range
0°C to 49°C (32°F to 120°F)
Operating Humidity Range
0 to 85% (non-condensing)
Dimensions
Height x Width x Depth
365 x 264 x 97 mm (14.4 x 10.4 x 3.8 in.)
Weight
3.4 kg (7.5 lb)