
Rosslare
Installation Instructions
Model Series AY-Q12
The AY-Q12 Prox Reader is a weather and
vandal resistant RFID proximity card
reader, to be installed for use with access
control systems.
These Installation Instructions contain the
following information:
* Mounting Instructions
* Wiring Instructions
* Operation Instructions
MOUNTING INSTRUCTION
To mount the Reader, perform the following:
1.
Determine an appropriate mounting position for the Reader.
2.
Peel off the back of the self-stick mounting label template
included with the unit and place at the desired mounting position.
3.
Using the template as a guide, drill two holes (hole size is
indicated on mounting template) for mounting the Reader to the
surface. Drill a 7/16" (10mm) hole for the cable. If mounting on
metal, place a grommet around the edge of the hole.
4.
Remove the case screw and slide the rear case away from the front
case. (See diagram below)
5.
Drill holes into the back of the rear metal case according to how
you want to mount the reader. (See Diagram below)
Attach the reader to the controller.
6.
Screw the readers rear case to its mounting location and return the
7.
front case onto the mounted rear case.
Secure the front cover by using the supplied security screw in the
8.
controllers accessories kit. An L-Shaped tool is provided for use
when tightening the security screw.
US Gang Box
There are two hole
indicators on the back of
the metal cover
specifically for the US
Gang Box. (Shown
marked as A)
4 Screw Custom
There are four indicators
on the back. (Shown
marked as B)
-1-
A
B
B
B
CAUTION!
DO NOT DRILL
This is the Tamper Lens
B
A
03/02
Card Readers are to be used with control panels whose power
supply is UL Listed Class 2 or equivalent.
WIRING INSTRUCTION
The Prox Reader is supplied with an 18-inch pigtail, having a 6conductor cable. To connect the Reader to the Controller, perform
the following steps:
Prepare the Reader cable by cutting the cable jacket back 1
1.
inches and strip the wires inch.
Prepare the Controller cable by cutting the cable jacket back 1
2.
inches and strip the wires inch.
Splice the Reader pigtail wires to the corresponding Controller
3.
1
/2
1
/2
1
1
wires and cover each connection (see Figure 2).
If the tamper output is being utilized, connect the purple wire to
4.
the correct input on the Controller.
Trim and cover all conductors that are not used.
5.
Figure 2 below shows how you should wire the Reader to the
Controller.
COLOR
Red
Black
White
Green
Brown
Purple
Cable Notes:
1.
The individual wires coming out of the reader are color coded according
to the recommended Wiegand standard.
When using a separate power supply for the Reader, this supply and the
2.
Controller's power supply must have a common ground.
The cable shield wire on the Reader should be attached to an Earth
3.
ground (best) or signal ground connection at the panel or power supply
end of the cable. This configuration is best for shielding the Reader
cable from external interference.
WIEGAND
OUTPUT
DC+Input
Ground
Data 1
Data 0
LED Control
Tamper
Figure 2
OPERATION INSTRUCTION
The Reader should be tested after wiring it to a power supply and the
Controller. Do this by performing the following steps:
1.
Power up the Reader. The LED and Beeper will activate three
times. This indicates that the Reader is working properly.
Present the appropriate type of proximity card to the Reader. The
2.
LED will momentarily flash green and a short beep will be
emitted. This indicates that the card was read properly by the Prox
Reader..
3.
After the card data is processed by the Controller, the Controller
can then turn the LED green. Refer to the Controller description
of the LED operation if the Reader LED is controlled by the
Controller.
SPECIFICATIONS
/4
Power Supply Type
Operating Voltage Range
/4
Maximum Input Current
Tamper Output
Maximum Cable Distance
to Controller
RF Modulation
Output Modulation 26-Bit Wiegand
*
Card Read Distance:
Regulatory Approvals:
Operating Temp. Range:
Operating Humidity:
Dimensions:
Measured using Rosslare Proximity Card (P/N AT-11/14) or
*
4.72” (120mm) L x 3” (76mm) W x 1” (27mm) D
equivalent. Range also depends on electrical environment and/or
proximity to metal.
Suitable for outdoor use
Linear type recommended
5 - 16 VDC
Standby : 35 mA
Read : 100 mA
Open collector, active low,
max. sink current is 16 mA
150 meters (500 ft.)
ASK
2” (55mm)
USA : UL 294 & FCC Part 15B
Europe : CE Listed
ooo o
-31 C to 63 C (-25 F to 145 F)
0 to 95% (non condensing)
UL File Number: BP9264
0706-0820022-00
-1-
-2-
-3-

Rosslare
Installation Instructions
Model Series AY-Q14
The AY-Q14 Prox Reader is a weather and
vandal resistant RFID proximity card
reader, to be installed for use with access
control systems.
These Installation Instructions contain the
following information:
* Mounting Instructions
* Wiring Instructions
* Operation Instructions
MOUNTING INSTRUCTION
To mount the Reader, perform the following:
1.
Determine an appropriate mounting position for the Reader.
2.
Peel off the back of the self-stick mounting label template
included with the unit and place at the desired mounting position.
3.
Using the template as a guide, drill two holes (hole size is
indicated on mounting template) for mounting the Reader to the
surface. Drill a 7/16" (10mm) hole for the cable. If mounting on
metal, place a grommet around the edge of the hole.
4.
Remove the case screw and slide the rear case away from the front
case. (See diagram below)
5.
Drill holes into the back of the rear metal case according to how
you want to mount the reader. (See Diagram below)
Attach the reader to the controller.
6.
Screw the readers rear case to its mounting location and return the
7.
front case onto the mounted rear case.
Secure the front cover by using the supplied security screw in the
8.
controllers accessories kit. An L-Shaped tool is provided for use
when tightening the security screw.
US Gang Box
There are two hole
indicators on the back of
the metal cover
specifically for the US
Gang Box. (Shown
marked as A)
4 Screw Custom
There are four indicators
on the back. (Shown
marked as B)
-1-
A
B
B
B
CAUTION!
DO NOT DRILL
This is the Tamper Lens
B
A
03/02
Card Readers are to be used with control panels whose power
supply is UL Listed Class 2 or equivalent.
WIRING INSTRUCTION
The Prox Reader is supplied with an 18-inch pigtail, having a 6conductor cable. To connect the Reader to the Controller, perform
the following steps:
Prepare the Reader cable by cutting the cable jacket back 1
1.
inches and strip the wires inch.
Prepare the Controller cable by cutting the cable jacket back 1
2.
inches and strip the wires inch.
Splice the Reader pigtail wires to the corresponding Controller
3.
1
/2
1
/2
1
1
wires and cover each connection (see Figure 2).
If the tamper output is being utilized, connect the purple wire to
4.
the correct input on the Controller.
Trim and cover all conductors that are not used.
5.
Figure 2 below shows how you should wire the Reader to the
Controller.
COLOR
Cable Notes:
1.
The individual wires coming out of the reader are color coded according
to the recommended Wiegand standard.
When using a separate power supply for the Reader, this supply and the
2.
Controller's power supply must have a common ground.
The cable shield wire on the Reader should be attached to an Earth
3.
ground (best) or signal ground connection at the panel or power supply
end of the cable. This configuration is best for shielding the Reader
cable from external interference.
Red
Black
White
Green
Brown
Purple
CLOCK & DATA
OUTPUT
DC+Input
Ground
Clock
Data
LED Control
Tamper
Figure 2
OPERATION INSTRUCTION
The Reader should be tested after wiring it to a power supply and the
Controller. Do this by performing the following steps:
1.
Power up the Reader. The LED and Beeper will activate three
times. This indicates that the Reader is working properly.
Present the appropriate type of proximity card to the Reader. The
2.
LED will momentarily flash green and a short beep will be
emitted. This indicates that the card was read properly by the Prox
Reader..
3.
After the card data is processed by the Controller, the Controller
can then turn the LED green. Refer to the Controller description
of the LED operation if the Reader LED is controlled by the
Controller.
SPECIFICATIONS
/4
Power Supply Type
Operating Voltage Range
/4
Maximum Input Current
Tamper Output
Maximum Cable Distance
to Controller
RF Modulation
Output Modulation Clock and Data
*
Card Read Distance:
Regulatory Approvals:
Operating Temp. Range:
Operating Humidity:
Dimensions:
Measured using Rosslare Proximity Card (P/N AT-11/14) or
*
4.72” (120mm) L x 3” (76mm) W x 1” (27mm) D
equivalent. Range also depends on electrical environment and/or
proximity to metal.
Suitable for outdoor use
Linear type recommended
5 - 16 VDC
Standby : 35 mA
Read : 100 mA
Open collector, active low,
max. sink current is 16 mA
150 meters (500 ft.)
ASK
2” (55mm)
USA : UL 294 & FCC Part 15B
Europe : CE Listed
ooo o
-31 C to 63 C (-25 F to 145 F)
0 to 95% (non condensing)
UL File Number: BP9264
0706-0820023-00
-1-
-2-
-3-