for ANSI
Accessories
Valves Series W70 & W74
Interposed Pressure Regulators
Both single and double interposed regulators are available for valves with CV
ratings up to 4.2. A regulator is bolted to the valve’s sub-base or manifold
station, and the valve is then bolted to the regulator. This mounting method
allows the valve to be removed and replaced without disturbing the regulator.
Single pressure regulators provide the same regulated pressure at both outlet
ports. Double pressure regulators allow the pressure at each outlet port to
be set independently.
A locking type knob is used to set the regulated pressure at any point in the
range of:
5 to 125 psig (0.3 to 8.5 bar) for size = 4.2 models.
Maximum inlet pressure is 150 psig (10 bar).
Pressure gauge(s) included.
Order regulators by the part numbers shown at the right.
5 to 100 psig (0.3 to 7 bar) for size 1 and 2 models;
Model Number
Single Double
Solenoid Solenoid Remote Air
C
= 0.9, Size 1 Valves: 840C91 841C91 713C91
V
= 2.0, Size 2.5 Valves: 626C91 627C91 714C91
C
V
= 4.2, Size 4 Valves: 632C91 633C91 715C91
C
V
* Double regulator only for W70 spool valves.
Double interposed regulators will reverse
output ports - the 12 solenoid will
WARNING:
pressurize the 4 port, the 14 solenoid will
pressurize the 2 port - which may cause
unexpected, potentially dangerous cylinder
movement at valve pressurization.
* Single
Manual Override Kits for ANSI Valves, Solenoid Pilot Controlled - Sizes 2.5, 4, 10, 20
Flush flexible manual overrides are standard on solenoid pilot
controlled valves with CV ratings of 2.0 or larger. Both locking
and non-locking metal override buttons are also available for
these models.
FLUSH BUTTON
Type Kit Number
Locking 792K87
Non-locking 790K87
EXTENDED BUTTON
Type Kit Number
Non-locking 791K87
Each of the override buttons in the kits at the right is made of metal
and is spring-returned. The locking type button, however, can be
kept in the actuated position by turning the slot in the top of the
button with a screwdriver.
Order by the kit numbers shown below.
EXTENDED BUTTON with PALM
Type Kit Number
Non-locking 984H87
3-Way Miniature Valves
Series W14
VALVE MODEL NUMBERS
With locking manual override ...........W1413A1408**
With non-locking manual override ...W1413A1409**
BASES: 1/8 NPT ports threads.
For BSPP threads, add a “D” prefix to the model number.
Sub-Base ....... 516B91
Manifold ......... 535K91
Note: Specify voltage when ordering.
**
Insert voltage code: “W” = 24 volts DC; “Z” = 110-120 volts AC, 50/60 Hz; e.g., W1413A1408W, W1413A1408Z.
STANDARD SPECIFICATIONS (for 3/2 Miniature valves):
Rating: 0.1.
C
V
Solenoids: AC or DC power.
Standard Voltages: 24 volts DC; 110-120 volts AC, 50/60 Hz.
For other voltages, see page 113.
Power Consumption: 8 VA inrush, 6 VA holding on 50 or 60 Hz;
6 watts on DC.
Ambient Temperature: 5° to 120°F (-15° to 50°C).
for Base Mounting
DIMENSIONS – inches (mm)
Valve is shown with electrical connector and on a base.
Electrical connector, optional.
Media Temperature: 5° to 175°F (-15° to 80°C).
For temperatures below 40°F (4°C) air must be free of water vapor
to prevent formation of ice.
Flow Media: Filtered air.
Inlet Pressure: Vacuum to 150 psig (10 bar).
Manual Override: Flush; metal, locking and non-locking.
Options:
Indicator Light: Optional in electrical connector, see page 18.
3.1 (79)
2.5
(64)
3.5
(89
1.3 (32)
IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS, WARNINGS on the inside back cover.