Ross Controls 5599-I SPOOL SLEEVE SERIES W60 User Manual

SERIES W60 SPOOL VALVES – Solenoid Control
ISO 5599/I - Drop Cord Connections
5/2 Single Solenoid Pilot Valve
5/2 Double Solenoid Pilot Valve
5/3 Open or Closed Center Valve
14
42
5
Closed Center
42
5
Open Center
42
5
42
13
5
13
13
13
STANDARD SPECIFICATIONS
12
Solenoids: Rated for continuous duty. Standard voltages: 100–110 volts 50 Hz.; 100–120 volts 60 Hz.; 24, 110 volts d.c. Power Consumption: 8.5 VA inrush; 6 VA holding on 50 or 60 Hz.; 6 watts on d.c.
Ambient Temperature: 40 to 120° F (4 to 50° C). Media Temperature: 40 to 175° F (4 to 80° C). Flow Media: 5 micron filtered air . Inlet Pressure: Vacuum to 150 psig (10 bar). Pilot Pressure:
Size 1: At least 30 psig (2 bar). Size 2 and 3: At least 15 psig (1 bar).
1214
OPTIONS
Sub-Bases & Manifolds: Page 14. Connectors, Electrical: Page 15. Regulators & Flow Controls, Interposed: Page 15. Locking Overrides: See note below . GM PS-1 models with 3-pin mini-connectors: See
note below .
1214
IMPORTANT NOTE
Please read carefully and thoroughly the
CAUTIONS on page 23.
**VALVE RESPONSE TIME (msec) = M + (F • V)
1214
Av erage time required to fill volume V (cubic inches) to 90% of supply pressure or to exhaust it to 10% of supply pressure. M and F values are shown in charts for each valve. See discussion of Valve Response Time on page 22.
§
5/2 SINGLE SOLENOID PILOT VALVES
Avg. Response Constants** Dimensions inches (mm)
Avg.CvISO
Size
Valve Model
Number
§
Port
Sizes*
M
F
Length Width
Height
Weight
lb (kg)
Out-Exh.In-Out
0.9
1.9
3.9
1 2 3
W6076B2401 W6076B3401 W6076B4401
1/8 – 3/8 3/8 – 1/2 1/2 – 3/4
29 41 51
3.5
1.5
0.8
4.9
2.4
1.1
1.7 (42)
2.1 (54)
2.6 (65)
4.4 (112)
4.7 (119)
4.9 (124)
1.5 (0.7)
2.0 (1.0)
3.5 (1.6)
5/2 DOUBLE SOLENOID PILOT VALVES
0.9
1.9
3.9
1 2 3
W6076B2407 W6076B3407 W6076B4407
1/8 – 3/8 3/8 – 1/2 1/2 – 3/4
17 20 20
3.5
1.5
0.8
5.0
2.5
1.1
17 (42)
2.1 (54)
2.6 (65)
4.4 (112)
4.7 (119)
4.9 (124)
2.0 (1.0)
2.5 (1.2)
4.0 (1.9)
5/3 CLOSED CENTER DOUBLE SOLENOID PILOT VALVES
0.9
1.9
3.9
1 2 3
W6077B2401 W6077B3401 W6077B4401
1/8 – 3/8 3/8 – 1/2 1/2 – 3/4
30 40 50
3.5
1.5
0.8
5.0
2.5
1.1
1.7 (42)
2.1 (54)
2.6 (65)
4.4 (112)
4.7 (119)
4.9 (124)
2.0 (1.0)
2.5 (1.2)
4.0 (1.9)
5/3 OPEN CENTER DOUBLE SOLENOID PILOT VALVES
0.9
1.9
3.9
§
Models with locking overrides can be ordered by changing the 9th digit of model number to “1”. For example, W6076B2411.
For models with 3-pin mini-connectors that conform to G.M. PS-1 standards, change the 9th digit to “3”. For example, W6076B2431.
* Port sizes determined by customer’s choice of base or manifold. Bases and manifolds sold separately – see page 14.
Height of valve with electrical connector installed. Connectors sold separately – see page 15.
1 2 3
W6077B2407 W6077B3407 W6077B4407
6
1/8 – 3/8 3/8 – 1/2 1/2 – 3/4
30 40 50
3.5
1.5
0.8
ROSS CONTROLS
5.0
2.5
1.1
®
1.7 (42)
2.1 (54)
2.6 (65)
4.4 (112)
4.7 (119)
4.9 (124)
2.0 (1.0)
2.5 (1.2)
4.0 (1.9)
SERIES W60 SPOOL VALVES – Pressure Control
ISO 5599/I
42
14
5/2 Single Remote Pilot Valve
12
STANDARD SPECIFICATIONS
13
5
Ambient/Media T emperature: 40 to 175° F (4 to 80° C).
Flow Media: 5 micron filtered air . Inlet Pressure: Vacuum to 150 psig (10 bar). Pilot Pressure:
Size 1: At least 30 psig (2 bar). Size 2 and 3: At least 15 psig (1 bar).
5/2 Double Remote Pilot Valve
5/3 Open or Closed Center Valve
Avg.CvISO
Size
Valve Model
Number
42
14
42
13
5
12
13
5
1214
Closed Center
42
13
5
1214
Open Center
5/2 SINGLE REMOTE PILOT VALVES
Avg. Response Constants** Dimensions inches (mm)
Port
Sizes*
M
OPTIONS
Sub-Bases & Manifolds: Page 14. Flow Controls, Interposed: Page 15. Regulators, Interposed: Page 15.
IMPORTANT NOTE
Please read carefully and thoroughly the
CAUTIONS on page 23.
**VALVE RESPONSE TIME (msec) = M + (F • V)
Av erage time required to fill volume V (cubic inches) to 90% of supply pressure or to exhaust it to 10% of supply pressure. M and F values are shown in charts for each valve. See discussion of Valve Response Time on page 22.
F
Out-Exh.In-Out
Length Width Height
Weight
lb (kg)
0.9
1.9
3.9
1 2 3
W6056B2411 W6056B3411 W6056B4411
1/8 – 3/8 3/8 – 1/2 1/2 – 3/4
29 41 51
3.5
1.5
0.8
4.9
2.4
1.1
1.7 (42)
2.1 (54)
2.6 (65)
1.8 (47)
2.1 (54)
2.3 (59)
5/2 DOUBLE REMOTE PILOT VALVES
0.9
1.9
3.9
1 2 3
W6056B2417 W6056B3417 W6056B4417
1/8 – 3/8 3/8 – 1/2 1/2 – 3/4
17 20 20
3.5
1.5
0.8
5.0
2.5
1.1
1.7 (42)
2.1 (54)
2.6 (65)
1.8 (47)
2.1 (54)
2.3 (59)
5/3 CLOSED CENTER DOUBLE REMOTE PILOT VALVES
0.9
1.9
3.9
1 2 3
W6057B2411 W6057B3411 W6057B4411
1/8 – 3/8 3/8 – 1/2 1/2 – 3/4
30 40 50
3.5
1.5
0.8
5.0
2.5
1.1
1.7 (42)
2.1 (54)
2.6 (65)
1.8 (47)
2.1 (54)
2.3 (59))
5/3 OPEN CENTER DOUBLE REMOTE PILOT VALVES
0.9
1.9
3.9
1 2 3
W6057B2417 W6057B3417 W6057B4417
1/8 – 3/8 3/8 – 1/2 1/2 – 3/4
30 40 50
3.5
1.5
0.8
5.0
2.5
1.1
1.7 (42)
2.1 (54)
2.6 (65)
1.8 (47)
2.1 (54)
2.3 (59))
* Port sizes determined by customer’s choice of base or manifold. Bases and manifolds sold separately – see page 14.
0.8 (0.4)
1.5 (0.7)
3.0 (1.4)
0.8 (0.4)
1.5 (0.7)
3.0 (1.4)
1.0 (0.5)
1.5 (0.7)
3.0 (1.4)
1.0 (0.5)
1.5 (0.7)
3.0 (1.4)
7www.rosscontrols.com
SUB-BASES and MANIFOLDS for ISO 5599/I VALVES
SUB-BASE NUMBERS and PORT SIZES
ISO
Size
1
2
3
Side
Ported 654K91 600C01
D600C01
642K91 601C01
D601C01
643K91 602C01
D602C01
644K91
Bottom
Ported
659K91
– –
660K91
– –
661K91
– –
C
L
HH
42
I
I
1, 2, 4
1/8 1/4
G1/4
3/8 3/8
G3/8
1/2 1/2
G1/2
3/4
Port Sizes
3, 5
1/4 1/4
G1/4
3/8 3/8
G3/8
1/2 1/2
G1/2
3/4
D
12 14
M
12, 14
1/8 1/8
G1/8
1/8 1/8
G1/8
1/8 1/8
G1/8
1/8
K
In addition to the manifold stations, an end station kit must be ordered for each manifold installation. End-ported stations are assemblies consisting of a bottom-ported station and an end-ported adaptor plate. Adaptor plates are cross-hatched in the drawings below.
MANIFOLD NUMBERS and PORT SIZES
C
L
ISO
Size
1
2
3
P N
N
Bottom
Ported
Station 460K91
D460K91
461K91
D461K91
462K91
D462K91
5
1
3
C
L
End Ported Station
664K91
D664K91
665K91
D665K91
666K91
D666K91
F
End
Station
Kit
326K86
D326K86
327K86
D327K86
328K86
D328K86
5
1
3
Port Sizes
2, 4
G1/4 G3/8 G1/2
1/4 3/8 1/2
1, 3, 5
3/8
G3/8
1/2
G1/2
1
G1
K
J
12, 14
1/8
G1/8
1/8
G1/8
1/8
G1/8
I
5
G
H
1
O
H
G
3
L
C
L
35
G
1
F
F
B
Sub-base Dimensions inches (mm)
ISO 1
1.89
4.33
1.26
0.41
0.85
0.85
0.39
0.47
1.14
0.94
0.93
3.86
0.22
(48)
(110)
(32) (11)
(22) (22)
(10) (12)
(29) (24)
(24) (98)
(6)
A B
C D
E F
G
H
I
J
K L
M
* 1.77 (45) on sub-base 644K91.
ISO 2 ISO 3
2.24
(57)
4.88
(124)
1.57
(40)
0.55
(14)
1.02
(26)
1.10
(28)
0.51
(13)
0.59
(15)
1.46
(37)
1.12
(29)
1.18
(30)
4.41
(112)
0.26
(7)
14
2.80
5.87
1.26
0.67
0.67
1.34
0.71
0.63
1.77
1.40
0.87
5.35
0.26
J
D
A
E
(71)
(149)
(32)*
(17) (17)
(34) (18)
(16) (45)
(36) (22)
(136)
(7)
C
ACCESSORIES and OPTIONS for MANIFOLDS
Blank Station Kits, Blocking Discs, Pressure Plates, Transition Plates and other available options are shown on page 15.
ROSS CONTROLS
DE
A
C
L
ML
BC
NOTE: Lined portions of
12 12
S
4
R
Q
2
4
2
drawings are end-ported adaptors which are included only with end-ported stations.
TT
Manifold Dimensions inches (mm)
ISO 1
5.12
0.87
1.69
0.30
0.06
4.25
0.55
0.94
0.83
0.94
1.81
0.33
0.85
0.51
4.33
0.27
0.47
0.98
3.19
0.43
(130)
(22) (43)
(8) (2)
(108)
(14) (24)
(21) (24)
(46)
(9)
(22) (13)
(110)
(7)
(12) (25)
(81) (11)
A B C D E
F G
H
I
J
K L
M N
O P
Q R
S T
A and F dimensions are for a 2-station manifold. For each additional station add the C dimension to obtain new A and F dimensions.
®
ISO 2 ISO 3
6.46
1.02
2.20
0.24
0.20
5.43
0.69
1.24
0.87
0.94
1.85
0.35
1.10
0.59
5.31
0.35
0.55
1.02
3.54
0.57
(164)
(26) (56)
(138)
(18) (32)
(22) (24)
(47) (28)
(15)
(135)
(14) (26)
(90) (15)
(6) (5)
(9)
(9)
7.95
1.18
2.80
0.31
0.24
6.77
1.02
1.85
1.22
1.34
2.20
0.39
1.40
0.75
7.48
0.47
0.67
1.14
3.90
0.71
(202)
(30) (71)
(8)
6)
(172)
(26) (47)
(31) (34)
(56) (10)
(36) (19)
(190)
(12) (17)
(29) (99)
(18)
ACCESSORIES for ISO 5599/I VALVES
CONNECTORS for use with DROPCORDS
Electrical connectors are required to connect the valve solenoids to the
dropcords supplying electrical power. Each connector can be oriented so that the cord can exit in any one of four directions: outboard, inboard, and to the right or to the left of the valve centerline. Cords of 6-mm to 10-mm diameter can be used.
Indicator Lights. Lights in connectors with a translucent housing can be used as indicator lights to show when sole­noids are energized.
Wired Connectors. Connec­tors have a 6-1/2- ft (2-meter) cord with three 18-gauge con­ductors. Cord exits outboard as shown at the right. Insula­tion is water , oil, and abrasion resistant. Connectors are available with 10-mm cords for maximum abrasion resistance, or with 6-mm cords where added flexibility or small diameter is required.
CONNECTORS for use with THREADED CONDUIT
Connectors similar to those above but threaded to accept 1/2-inch electrical conduit fittings are also available.
FLYING SOLENOID LEADS
Instead of the connectors described, power to the solenoids can also be supplied via “flying leads.” These are 18-gauge insulated wires with spade connectors at one end. A kit of flying leads consists of three wires, each 39 inches (one meter) long. Order by kit number 725K77.
PART NUMBERS of ELECTRICAL CONNECTORS
Connector Type
For use with drop cord (Cord not included)
Wired with 6-mm cord Wired with 10-mm cord For use with threaded conduit
* Specify solenoid voltage.
Without
Light
937K87 721K77
371K77 723K77
With
Light*
936K87 720K77
383K77 724K77
BLANK STATION KITS
A blank station plate is used to cover the top of a manifold station that is not in use. A kit consists of a metal plate 0.32 inch (8mm) thick, a gasket, and mounting bolts.
ISO Size 1: 546H77 ISO Size 2: 694K77 ISO Size 3: 537H77
TRANSITION PLATES
Different size ISO valv es can be used in the same manifold installation by means of transition plates. The inlet and e x­haust ports of two different size manifold stations are con­nected by means of a transition plate installed between the two stations Thic kness [inches (mm)] of the plates is shown below.
ISO Size 1 to 2 - 0.79 (20): D355K86 ISO Size 2 to 3 - 1.26 (32): D356K86 ISO Size 1 to 3 - 1.26 (32): D357K86
INTERPOSED FLOW CONTROLS for SPOOL VALVES
An interposed flow control unit regulates the exhaust flow of air from a pneumatic cylinder, thereby controlling the e x­tension and retraction speeds. Separate controls regulate the air flow from each end of the cylinder. Being located between the valve and base, the unit requires no additional piping. A vailable only f or Series W60 and W63 spool v alves.
ISO Size 1: 701B77 ISO Size 2: 702B77 ISO Size 3: 722K77
INDEPENDENT PRESSURE PLATES
When a valve in a manifold installation must work at a dif­ferent pressure than that supplied to the manifold, an inde­pendent supply can be provided via an independent pres­sure plate. The pressure plate mounts between valve and base and isolates the valve from the manifold inlet pres­sure. The independent supply is connected to an inlet port in the end of the pressure plate.
ISO Size 1 (1/4 inlet port): 703K77 ISO Size 2 (3/8 inlet port): 692K77 ISO Size 3 (1/2 inlet port): 715K77
BLOCKING DISKS
Ports between manifold stations can be closed by means of blocking disks.
Single Disk Kit of 3 Disks ISO Size 1: 235A40 1007K77 ISO Size 2: 236A40 1008K77 ISO Size 3: 253A40 1009K77
INTERPOSED PRESSURE REGULATORS
Both single and double pressure regulators are available. Single pressure regulators provide the same regulated pres­sure at both outlet ports. Double pressure regulators al­low the pressure at each outlet port to be set independently. Pressure can be regulated from 5 to 100 psig (0.3 to 7 bar) for ISO sizes 1 and 2;
A
Single Regulator
5 to 125 psig (0.3 to
8.5 bar) for ISO size
3. Maximum inlet pressure is 150 psig (10 bar). Requires no new piping.
Double Regulator
Double**
ISO Size
1 2 3
**Double regulators only for series W60 and W63 spool valves.
Regulator Dimensions - inches (mm)
ISO Size
1 2 3
Single
620C91 624C91 628C91
A
(Single)
7.75 (197)
8.25 (210)
12.70 (323)
(Solenoid)
621C91 625C91 629C91
A
(Double)
12.90 (328)
13.60 (346)
20.00 (508)
A
Double**
(Air)
710C91 711C91 712C91
B
(Single/Double)
B
B
15www.rosscontrols.com
Loading...