SERIES W60 SPOOL VALVES – Solenoid Control
ISO 5599/I - Drop Cord Connections
5/2 Single Solenoid Pilot Valve
5/2 Double Solenoid Pilot Valve
5/3 Open or Closed Center Valve
14
42
5
Closed Center
42
5
Open Center
42
5
42
13
5
13
13
13
STANDARD SPECIFICATIONS
12
Solenoids: Rated for continuous duty.
Standard voltages: 100–110 volts 50 Hz.; 100–120
volts 60 Hz.; 24, 110 volts d.c.
Power Consumption: 8.5 VA inrush; 6 VA holding
on 50 or 60 Hz.; 6 watts on d.c.
Ambient Temperature: 40 to 120° F (4 to 50° C).
Media Temperature: 40 to 175° F (4 to 80° C).
Flow Media: 5 micron filtered air .
Inlet Pressure: Vacuum to 150 psig (10 bar).
Pilot Pressure:
Size 1: At least 30 psig (2 bar).
Size 2 and 3: At least 15 psig (1 bar).
1214
OPTIONS
Sub-Bases & Manifolds: Page 14.
Connectors, Electrical: Page 15.
Regulators & Flow Controls, Interposed: Page 15.
Locking Overrides: See note below .
GM PS-1 models with 3-pin mini-connectors: See
note below .
1214
IMPORTANT NOTE
Please read carefully and thoroughly the
CAUTIONS on page 23.
**VALVE RESPONSE TIME (msec) = M + (F • V)
1214
Av erage time required to fill volume V (cubic inches)
to 90% of supply pressure or to exhaust it to 10%
of supply pressure. M and F values are shown in
charts for each valve. See discussion of Valve
Response Time on page 22.
§
5/2 SINGLE SOLENOID PILOT VALVES
Avg. Response Constants** Dimensions inches (mm)
Avg.CvISO
Size
Valve Model
Number
§
Port
Sizes*
M
F
Length Width
Height
†
Weight
lb (kg)
Out-Exh.In-Out
0.9
1.9
3.9
1
2
3
W6076B2401
W6076B3401
W6076B4401
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
29
41
51
3.5
1.5
0.8
4.9
2.4
1.1
5.4 (137)
6.2 (158)
5.9 (150)
1.7 (42)
2.1 (54)
2.6 (65)
4.4 (112)
4.7 (119)
4.9 (124)
1.5 (0.7)
2.0 (1.0)
3.5 (1.6)
5/2 DOUBLE SOLENOID PILOT VALVES
0.9
1.9
3.9
1
2
3
W6076B2407
W6076B3407
W6076B4407
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
17
20
20
3.5
1.5
0.8
5.0
2.5
1.1
6.7 (170)
7.5 (191)
6.0 (152)
17 (42)
2.1 (54)
2.6 (65)
4.4 (112)
4.7 (119)
4.9 (124)
2.0 (1.0)
2.5 (1.2)
4.0 (1.9)
5/3 CLOSED CENTER DOUBLE SOLENOID PILOT VALVES
0.9
1.9
3.9
1
2
3
W6077B2401
W6077B3401
W6077B4401
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
30
40
50
3.5
1.5
0.8
5.0
2.5
1.1
6.7 (170)
7.7 (196)
6.2 (158)
1.7 (42)
2.1 (54)
2.6 (65)
4.4 (112)
4.7 (119)
4.9 (124)
2.0 (1.0)
2.5 (1.2)
4.0 (1.9)
5/3 OPEN CENTER DOUBLE SOLENOID PILOT VALVES
0.9
1.9
3.9
§
Models with locking overrides can be ordered by changing the 9th digit of model number to “1”. For example, W6076B2411.
For models with 3-pin mini-connectors that conform to G.M. PS-1 standards, change the 9th digit to “3”. For example, W6076B2431.
* Port sizes determined by customer’s choice of base or manifold. Bases and manifolds sold separately – see page 14.
†
Height of valve with electrical connector installed. Connectors sold separately – see page 15.
1
2
3
W6077B2407
W6077B3407
W6077B4407
6
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
30
40
50
3.5
1.5
0.8
ROSS CONTROLS
5.0
2.5
1.1
®
6.7 (170)
7.7 (196)
6.2 (158)
1.7 (42)
2.1 (54)
2.6 (65)
4.4 (112)
4.7 (119)
4.9 (124)
2.0 (1.0)
2.5 (1.2)
4.0 (1.9)
SERIES W60 SPOOL VALVES – Pressure Control
ISO 5599/I
42
14
5/2 Single Remote Pilot Valve
12
STANDARD SPECIFICATIONS
13
5
Ambient/Media T emperature: 40 to 175° F
(4 to 80° C).
Flow Media: 5 micron filtered air .
Inlet Pressure: Vacuum to 150 psig (10 bar).
Pilot Pressure:
Size 1: At least 30 psig (2 bar).
Size 2 and 3: At least 15 psig (1 bar).
5/2 Double Remote Pilot Valve
5/3 Open or Closed Center Valve
Avg.CvISO
Size
Valve Model
Number
42
14
42
13
5
12
13
5
1214
Closed Center
42
13
5
1214
Open Center
5/2 SINGLE REMOTE PILOT VALVES
Avg. Response Constants** Dimensions inches (mm)
Port
Sizes*
M
OPTIONS
Sub-Bases & Manifolds: Page 14.
Flow Controls, Interposed: Page 15.
Regulators, Interposed: Page 15.
IMPORTANT NOTE
Please read carefully and thoroughly the
CAUTIONS on page 23.
**VALVE RESPONSE TIME (msec) = M + (F • V)
Av erage time required to fill volume V (cubic inches)
to 90% of supply pressure or to exhaust it to 10%
of supply pressure. M and F values are shown in
charts for each valve. See discussion of Valve
Response Time on page 22.
F
Out-Exh.In-Out
Length Width Height
Weight
lb (kg)
0.9
1.9
3.9
1
2
3
W6056B2411
W6056B3411
W6056B4411
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
29
41
51
3.5
1.5
0.8
4.9
2.4
1.1
4.2 (106)
5.0 (127)
6.0 (152)
1.7 (42)
2.1 (54)
2.6 (65)
1.8 (47)
2.1 (54)
2.3 (59)
5/2 DOUBLE REMOTE PILOT VALVES
0.9
1.9
3.9
1
2
3
W6056B2417
W6056B3417
W6056B4417
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
17
20
20
3.5
1.5
0.8
5.0
2.5
1.1
4.2 (106)
5.0 (127)
6.0 (152)
1.7 (42)
2.1 (54)
2.6 (65)
1.8 (47)
2.1 (54)
2.3 (59)
5/3 CLOSED CENTER DOUBLE REMOTE PILOT VALVES
0.9
1.9
3.9
1
2
3
W6057B2411
W6057B3411
W6057B4411
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
30
40
50
3.5
1.5
0.8
5.0
2.5
1.1
4.3 (108)
5.3 (135)
6.6 (168)
1.7 (42)
2.1 (54)
2.6 (65)
1.8 (47)
2.1 (54)
2.3 (59))
5/3 OPEN CENTER DOUBLE REMOTE PILOT VALVES
0.9
1.9
3.9
1
2
3
W6057B2417
W6057B3417
W6057B4417
1/8 – 3/8
3/8 – 1/2
1/2 – 3/4
30
40
50
3.5
1.5
0.8
5.0
2.5
1.1
4.3 (108)
5.3 (135)
6.6 (168)
1.7 (42)
2.1 (54)
2.6 (65)
1.8 (47)
2.1 (54)
2.3 (59))
* Port sizes determined by customer’s choice of base or manifold. Bases and manifolds sold separately – see page 14.
0.8 (0.4)
1.5 (0.7)
3.0 (1.4)
0.8 (0.4)
1.5 (0.7)
3.0 (1.4)
1.0 (0.5)
1.5 (0.7)
3.0 (1.4)
1.0 (0.5)
1.5 (0.7)
3.0 (1.4)
7www.rosscontrols.com