Ross RAAC2/24, RAAC2.5/36 Instructions For Installation, Use And Maintenance Manual

RAAC2/24 and RAAC2.5/36
Direct drive electric air compressors
General instruction for installation use and maintenance
Protect yourself and others by observing all safety information, warnings, and cautions. Failure to comply with instructions could result in personal injury and/or damage to product or property. Please retain instructions for future reference.
RAAC2/24 and RAAC2.5/36
2
ITEM
DATA
Model
2HP 24litre 2.5HP 36Litre
Power
1.5Kw/2HP
1.8Kw/2.5HP
Voltage
240V
Frequency
50Hz
Motor Poles
2P
Rated Speed
2850 r/min
Current
7.5A
8A
Delivery
115L/Min
134L/Min
Discharge Pressure
115PSI/8 Bar
Tank Capacity
24L 36L
Air Outlet Size
1/4” BSP
Part No.
RAAC2/24 RAAC2.5/36
SPECIFICATIONS
Warranty
This product has been manufactured to a high quality standard. It is guaranteed against faulty materials and workmanship for 12 months from the date of purchase. Please retain your receipt as proof of purchase.
If the product is found to be defective within the relevant time period, we will either replace all defective parts or, at our discretion, replace the unit free of charge with the same item or items of a greater value and/or specification.
This guarantee does not cover defects caused by or resulting from: misuse, abuse or neglect; lack of maintenance; trade, professional or hire use; repairs attempted by anyone other than our authorised service agent; or damage caused by foreign objects, substances or accident.
RAAC2/24 and RAAC2.5/36
3
GENERAL SAFETY INSTRUCTIONS
Before attempting to operate this compressor the following basic safety precautions should always be taken to reduce the risk of fire, electric shock and personal injury. It is important to read the instruction manual to understand the application, limitations and potential hazards associated with any tool. They are designed for the safety of yourself and others, ensuring a long and trouble free service life from your machine.
SAFE OPERATION
Work Area
Workbenches should be kept tidy because cluttered benches and work areas invite accidents.
Floors should be kept clean and free from rubbish. Special care should be taken if the floor is
slippery due to sawdust or wax.
Work Environment
Keep the work area well lit. Do not use compressor in areas where there is a risk of explosion
or fire from combustible materials, flammable liquids, e.g., paint, varnish, petrol etc or flam-
mable gases and dust of an explosive nature.
Guard Against Electric Shock
Do not expose your compressor to rain, or use in damp or wet locations.
Beware Children and Pets
Children and pets should be kept out of the work area.
Use the right tool
Select the right tool for the job. Do not use a tool for a job for which it was not designed. Do not force a small tool to do the job of a heavy-duty tool.
Personal safety Clothing
Do not wear loose clothing, jewellery or anything that could get caught in moving machinery.
Hair
Long hair should be tied back or contained in a protective covering.
Eye Protection
All ways use protective safety goggles or safety glasses.
Ear Protection
Ear protection is advised during periods of extended operation.
Footwear
Where there is a risk of heavy objects damaging feet or if there is a risk of slipping on wet or slippery floors suitable non-slip safety footwear should be worn.
RAAC2/24 and RAAC2.5/36
4
Secure the Work Piece
Wherever possible secure the work piece using clamps or a vice. It is safer than using your hand and leaves both hands free to control the air tool. Do Not Over-reach Do not over-reach, keep proper footing and maintain your balance at all times. Maintain Tools with Care Keep cutting tools sharp and clean for better and safer performance. Follow the instructions for lubricating and changing accessories. Check the tool power cord periodically and if damaged have it replaced by an authorised service facility. Keep handles dry, clean and free from oil and grease. Ensure that ventilation slots are kept clean and free from dust at all times. Blocked venti­lation slots can cause overheating and damage to the motor.
Stay Alert
Watch what you are doing, use common sense, and do not operate the air tool when you are tired or have taken medication that causes drowsiness, consumed alcohol or drugs.
FOR ADDITIONAL PROTECTION FROM ELECTRIC SHOCK
It is recommended that this tool be used in conjunction with a residual current device (RCD) with a rated residual current of 30mA or less.
General Warnings for compressors
Do not attempt to modify the compressor in any way.
The use of any tools or accessory other than those designed for use with compressed air could result in injury to the operator.
The output pressure of the compressor should be adjusted to the design pressure of the air tool or accessory being used.
Always check that the output of the compressor does not exceed the maximum pressure for any attached tool or accessory.
Repairs should only be carried out by qualified persons using original spare parts. Fail­ure to do so may result in considerable danger to the user.
Breathable Air Warning
This compressor/pump is not equipped and should not be used to supply breathing quality air for any application of air for human consumption.
Overload protection. This compressor is fitted with an overload protection device. In the event that the motor becomes too hot, a thermal protection device will cut the mains supply to the mo­tor. When the motor temperature returns to normal the mains supply will be restored automati­cally.
Loading...