Contents of this publication may not be reproduced in any form without the written permission of Ross
Video Limited. Reproduction or reverse engineering of copyrighted software is prohibited.
Notice
The material in this manual is furnished for informational use only. It is subject to change without
notice and should not be construed as a commitment by Ross Video Limited. Ross Video Limited
assumes no responsibility or liability for errors or inaccuracies that may appear in this manual.
Trademarks
• is a registered trademark of Ross Video Limited.
• Ross, ROSS, ROSS
• All other product names and any registered and unregistered trademarks mentioned in
this manual are used for identification purposes only and remain the exclusive property
of their respective owners.
, and MLE are registered trademarks of Ross Video Limited.
Important Regulatory and Safety Notices
Before using this product and any associated equipment, refer to the “Important Safety Instructions”
listed below so as to avoid personnel injury and to prevent product damage.
Products may require specific equipment, and /or installation procedures be carried out to satisfy
certain regulatory compliance requirements. Notices have been included in this publication to call
attention to these Specific requirements.
Symbol Meanings
Warning
Caution
Notice
ESD
Susceptibility
This symbol on the equipment refers you to important operating and maintenance
(servicing) instructions within the Product Manual Documentation. Failure to heed
this information may present a major risk of damage or injury to persons or
equipment.
The symbol with the word “Warning” within the equipment manual indicates a
potentially hazardous situation, which if not avoided, could result in death or serious
injury.
The symbol with the word “Caution” within the equipment manual indicates a
potentially hazardous situation, which if not avoided, may result in minor or
moderate injury. It may also be used to alert against unsafe practices.
The symbol with the word “Notice” within the equipment manual indicates a
situation, which if not avoided, may result in major or minor equipment damage or a
situation which could place the equipment in a non-compliant operating state.
This symbol is used to alert the user that an electrical or electronic device or
assembly is susceptible to damage from an ESD event.
Important Safety Instructions
Caution
Warning
Warning
This product is intended to be a component product of the RossGear 8000 series
frame. Refer to the RossGear 8000 series frame User Manual for important safety
instructions regarding the proper installation and safe operation of the frame as well
as it’s component products.
Certain parts of this equipment namely the power supply area still present a safety
hazard, with the power switch in the OFF position. To avoid electrical shock,
disconnect all A/C power cords from the chassis' rear appliance connectors before
servicing this area.
Service barriers within this product are intended to protect the operator and service
personnel from hazardous voltages. For continued safety, replace all barriers after
any servicing.
This product contains safety critical parts, which if incorrectly replaced may present
a risk of fire or electrical shock. Components contained within the product’s power
supplies and power supply area, are not intended to be customer serviced and should
be returned to the factory for repair.
To reduce the risk of fire, replacement fuses must be the same type and rating.
Only use attachments/accessories specified by the manufacturer.
EMC Notices
US FCC Part 15
This equipment has been tested and found to comply with the limits for a class A Digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
users will be required to correct the interference at their own expense.
Notice
Changes or modifications to this equipment not expressly approved by Ross Video
Ltd. could void the user’s authority to operate this equipment.
CANADA
This Class “A” digital apparatus complies with Canadian ICES-003.
Cet appareil numerique de classe “A” est conforme à la norme NMB-003 du Canada.
EUROPE
This equipment is in compliance with the essential requirements and other relevant provisions of CE
Directive 93/68/EEC.
INTERNATIONAL
This equipment has been tested to CISPR 22:1997 along with amendments A1:2000 and A2:2002 and
found to comply with the limits for a Class A Digital device.
Notice
This is a Class A product. In domestic environments this product may cause radio
interference in which case the user may have to take adequate measures.
Maintenance/User Serviceable Parts
Routine maintenance to this RossGear product is not required. This product contains no user
serviceable parts. If the module does not appear to be working properly, please contact Technical
Support using the numbers listed under the “Contact Us” section on the last page of this manual. All
RossGear products are covered by a generous 5-year warranty and will be repaired without charge for
materials or labor within this period. See the “Warranty and Repair Policy” section in this manual for
details.
Environmental Information
The equipment that you purchased required the extraction and use of natural resources for its
production. It may contain hazardous substances that could impact health and the environment.
To avoid the potential release of those substances into the environment and to diminish the need for
the extraction of natural resources, Ross Video encourages you to use the appropriate take-back
systems. These systems will reuse or recycle most of the materials from your end-of-life equipment in
an environmentally friendly and health conscious manner.
The crossed-out wheeled bin symbol invites you to use these systems.
If you need more information on the collection, reuse, and recycling systems, please contact your local
or regional waste administration.
You can also contact Ross Video for more information on the environmental performances of our
products.
Contents
Introduction 1-1
In This Chapter .......................................................................................................................1-1
A Word of Thanks....................................................................................................1-1
Warranty and Repair Policy .....................................................................................5-2
AMA-8511 User Manual (Iss. 03) Contents • i
Ordering Information 6-1
In This Chapter ...................................................................................................................... 6-1
AMA-8511 and Related Products ........................................................................... 6-1
ii • Contents AMA-8511 User Manual (Iss. 03)
Introduction
In This Chapter
This chapter contains the following information sections:
• A Word of Thanks
• Overview
• Functional Block Diagram
• Features
• Documentation Terms
A Word of Thanks
Congratulations on choosing the Ross Video AMA-8511 AES/EBU Distribution Amplifier and
Converter. The AMA-8511 is part of a full line of Digital Products within the RossGear Terminal
Equipment family of products, backed by Ross Video’s experience in engineering and design expertise
since 1974.
You will be pleased at how easily your new AMA-8511 fits into your overall working environment.
Equally pleasing is the product quality, reliability and functionality. Thank you for joining the group
of worldwide satisfied Ross Video customers!
Should you have a question pertaining to the installation or operation of your AMA-8511, please
contact us at the numbers listed on the back cover of this manual. Our technical support staff is always
available for consultation, training, or service.
AMA-8511 User Manual (Iss. 03) Introduction • 1-1
Overview
The RossGear AMA-8511 AES/EBU Distribution Amplifier and Converter is a broadcast quality
digital AES/EBU audio reclocking distribution amplifier, as well as a modular product used to convert
20 or 24 bit AES-3id (coaxial) signals to analog audio. The AMA-8511 accepts one 32, 44.1, or
48kHz sample rate AES/EBU audio signal and provides two copies of balanced stereo (A, B) analog
audio and four reclocked copies of the input signal. The RossGear AMA-8511 is designed for use in
75-ohm coaxial SMPTE 276M or AES-3id systems.
The AMA-8511 provides automatic cable equalization for lengths up to and beyond 610m (2000 ft.).
The D/A converter uses a state of the art 24bit 128X over-sampled Delta Sigma Modulator DAC to
convert to analog audio. Following the D/A conversion, the analog audio passes through a very high
quality reconstruction filter that assures low distortion and noise. Two identical copies of the analog
signal are output via the rear plug-on module, the CON-8516 AES Audio Connector (included with
the card).
A coarse level adjustment headroom jumper (18dB or 24dB), and a fine adjustment potentiometer
(±6dB) are provided to precisely match to your facility’s house reference audio level. The AMA-8511
can accommodate any full-scale digital (FSD) level in the -12 to - 30dBFS range. Automatic detection
of AES/EBU 50/15µs de-emphasis is available for all data rates.
The AMA-8511 has been designed with the capability to report a variety of AES signal errors
including No Lock, Coding, Parity, CRC, and Validity. These errors are indicated on a card edge
LED. In addition, there is a SMPTE 269M fault reporting output to the back of the Ross frame.
The AMA-8511 fits into Ross 8000A series digital frames, the DFR-8110A (2RU) and the DFR8104A (1RU), and provides system builders with the ability to easily distribute and convert digital
audio within a facility.
A reclocking amplifier is the preferred method of distribution for long coaxial runs to reduce jitter in
the data stream. The AMA-8511 performs reclocking in a two-stage process that develops an output,
which is stable and noise-free.
The AMA-8511 is part of a complete line of RossGear AES solutions that includes distribution,
conversion, and monitoring. Designed and manufactured to meet the highest quality broadcast
industry standards, the RossGear AMA-8511 is an ideal, flexible, and cost effective solution for your
digital audio reclocking distribution and digital to analog conversion requirements.
Functional Block Diagram
Figure 1. Simplified Block Diagram of AMA-8511 Functions
1-2 • Introduction AMA-8511 User Manual (Iss. 03)
Loading...
+ 22 hidden pages
You need points to download manuals.