Ross 1000-SERIES Operating Instructions Manual

CCHHAANNGGIINNGG TTHHEE BBAATTTTEERRYY
Specifications
1000-SERIES
ELECTRONIC COMBINATION
SAFE LOCK
OPERATING INSTRUCTIONS
CCHHAANNGGIINNGG
TTHHEE
BBAATTTTEERRY
Y
This unit runs on a 9V alkaline battery. It is recommended that either ‘Duracell’ or ‘Energizer’ brands be used.
To change the battery, please refer to the diagram below.
Simply slide the entry pad housing up and
carefully pull it away from the mounting surface to expose the battery compartment.
The battery connector is easily removed by
unclipping it from the terminals on top of the battery. Care must be taken to ensure that the wires leading from the battery connector to the entry pad are not pulled out from the housing.
Once the battery has been changed, carefully
position the entry pad back over the mounting screws and slide the entry pad back into position. Ensure there are no wires or cables trapped between the entry pad and the safe door.
Distributor :-
ROSS
A.B.N. 23 609 454 458
K.J.ROSS SECURITY LOCKS
PTY.LTD.
Lock Manufacturer i Specialist in Safe & Vault Locks
29 Henderson Road, Knoxfield, Victoria 3180, Australia. Telephone :- + 61 3 9763 1796 Fax :- + 61 3 9763 4223 Email :- rosslocks@rosslocks.com.au Web :- www.rosslocks.com.au
AUSTRALIAN MADE
MMAANNAAGGEERR SSTTAARRTTUUPP IINNSSTTRRUUCCTTIIOONNSS
TTOO OOPPEENN
FFOORR TTHHEE
FFIIRRSSTT TTIIMME
E
Using the factory set manager code –
Enter ( 1 2 3 4 5 6 ) 2 beeps sound.
The handle can now be turned to open the safe door.
TTOO
CCHHAANNGGEE
TTHHEE
MMAANNAAGGEERR
CCOODDE
E
Always perform the following instructions with safe door open.
Enter ( 0 0 0 0 0 0 ) 2 beeps sound.
Enter the factory set manager code
( 1 2 3 4 5 6 ) 2 beeps sound.
Enter the new 6 digit manager code. 1 beep sounds.
To verify, re-enter the same manager code. 1 beep sounds.
Enter the new manager code to verify the new code has been accepted. 2 beeps sound.
TTOO AADDDD TTHHEE UUSSEERR CCOODDEE FFOORR TTHHEE FFIIRRSSTT
TTIIMME
E
Enter the manager code, and on the last digit of the code, hold the button down until 2 set of 2 beeps are sounded.
Enter ( 1 ) 2 beeps sound.
Enter the 6 digit user code. 1 beep sounds.
To verify, re-enter the same user code. 1 beep sounds.
Enter the new user code to verify the new code has been accepted. 2 beeps sound.
MMAANNAAGGEERR OOPPEERRAATTIIOONNAALL IINNSSTTRRUUCCTTIIOONNSS
TTOO
CCHHAANNGGEE
TTHHEE UUSSEERR
CCOODDE
E
Always perform the following instructions with safe door open.
Enter ( 0 0 0 0 0 0 ) 2 beeps sound.
Enter the user code. 2 beeps sound.
Enter the new 6 digit user code. 1 beep sounds.
To verify, re-enter the same user code. 1 beep sounds.
Enter the new user code to verify the new code has been accepted. 2 beeps sound.
TTOO
DDIISSAABBLLEE
TTHHEE UUSSEERR
CCOODDE
E
Enter the manager code, and on the last digit of the code, hold the button down until 2 set of 2 beeps are sounded.
Enter ( 2 ) 2 beeps sound.
Enter the user code to verify this code has been disabled.
TTOO
EENNAABBLLEE
TTHHEE UUSSEERR
CCOODDEE
Enter the manager code, and on the last digit of the code, hold the button down until 2 set of 2 beeps are sounded.
Enter ( 1 ) 2 beeps sound.
Enter the user code to verify this code has been enabled.
TTOO
DDEELLEETTEE
TTHHEE UUSSEERR
CCOODDEE
Enter the manager code, and on the last digit of the code, hold the button down until 2 set of 2 beeps are sounded.
Enter ( 3 ) 2 beeps sound.
Enter the user code to verify this code has been deleted.
To re-enter the user code, follow the procedure, “ To add the user code for the first time”.
OOPPEERRAATTIIOONNAALL FFEEAATTUURREESS
SSTTAANNDDBBYY
MMOODDE
E
There is a time limit of 15 seconds allocated to
complete an instruction.
nd to indicated you will need to 2 beeps will sou
re-start the instruction again.
WWRROONNGG
EENNTTRRYY
PPEENNAALLTTY
Y
If 4 consecutive invalid codes have been entered,
a 5 minute delay period will be activated.
l A beep, in intervals of 5 seconds, will sound unti
the time delay period has expired.
AAUUTTOOMMAATTIICC
RREE--LLOOCCK
K
A re-lock will occur within 4 seconds.
LLOOWW
BBAATTTTEERRYY
IINNDDIICCAATTOOR
R
If during the unlock cycle, a repeated beeping
sound is detected, the battery is low and needs to be replaced.
It is recommended that either “Energizer” or
“Duracell” brands be used.
To change the battery, please refer to the
procedure, “Changing the battery”.
UUSSEERR OOPPEERRAATTIIOONNAALL IINNSSTTRRUUCCTTIIOONNSS
CCHHAANNGGEE
TTHHEE UUSSEERR
CCOODDE
E
Always perform the following instructions with safe door open.
Enter ( 0 0 0 0 0 0 ) 2 beeps sound.
Enter the user code. 2 beeps sound.
Enter the new 6 digit user code. 1 beep sounds.
To verify, re-enter the same user code. 1 beep sounds.
Enter the new user code to verify the new code has been accepted. 2 beeps sound.
Loading...