Introduction
1
Thank you for purchasing this infrared thermometer-Econ. Version. This infrared thermometer is non-contact infrared temperature measuring instruments. Features include a4 digits backlit LCD, scan/hold function and auto power off (6 seconds).To measure a temperature, point the unit at the object, pull the measuring trigger and hold. Make sure the target area is larger than the unit’s spot size.
Safety Information
1
2
Read the following safety information carefully before attempting to operate or service the meter. Only qualified personnel should perform repairs or servicing not covered in this manual.
2-1 Cautions!
● DO NOT submerge the unit in water.
● This product is not designed for use in medical evaluations. The product can only
be used to measure body temperature simply for reference. They are meant for industrial and scientific purposes.
Laser Warning Note!
Do not point laser directly at eye. Use caution a round reflective surfaces. Keep out of reach of children.
2-2 Safety symbols
Dangerous, refer to this manual before using the meter.
CE Certification.
This instrument conforms to the following standards:
EN61326
Electrical equipment for measurement, control and laboratory use.
IEC61000-4-2
Electrostatic discharge immunity test.
user manual
Infrared Thermometer / Thermomètre infrarouge
2
Maintenace
3
IEC61000-4-3
Radiated, radio-frequency, electromagnetic field immunity test.
IEC61000-4-8
Power frequency magneticfield immunity test.
IEC60825-1
Safety
Tests were conducted using a frequency range of 80-1000MHz with the instrument in three orientations. The average error for the three orientations is ±0.5°C (±1.0°F) at 3V/m throughout the spectrum. However, between 781-1000MHz at 3V/m, the instrument may not meet its stated accuracy.
Cleaning the lens: Blow off loose particles using clean compressed air. Gently brush remaining debris away with a camel’s hair brush. Carefully wipe the surface with a moist cotton swab. The swab may be moistened with water.
NOTE:
DO NOT use solvents to clean the glass lens.
Cleaning the housing:
Use soap and water on a damp sponge or soft cloth.
Restrict to use of six substances within electrical and electronic equipment (EEE), thereby contributing to the protection of human health and the environment.
The device of used materials content no following substances that list of proposed REACH substances of very high concern .
The device may not be disposed of with the trash. It promotes the re-use recycling and other forms of recovery of used materials and components, and to improve the environmental performance of all operators (manufacturers, traders and treatment facilities) involved in the life cycle of products. Dispose of the product appropriately in accordance with the regulations in force in your country.
RoHS
REACH (SVHC)
user manual
Infrared Thermometer / Thermomètre infrarouge
3
Specification
4
Operation of instrument
5
Temperature Range
Accuracy
Distance/Spot Ratio Resolution Response Time Emissivity Auto Power Off C/F Switchable Backlight Laser Sight Switchable Dimension Weight
-35ºC ~ 500ºC (-31ºF ~ 932ºF) ±3.0ºC/±5.4ºF (-35ºC~-20ºC / -31ºF~-4ºF) ±2.0ºC/±3.6ºF (-20ºC~0ºC / -4ºF~32ºF), ±1.5ºC/±2.7ºF (0ºC~60ºC / 32ºF~140ºF), ±2.0ºC/±3.6ºF (60ºC~100ºC / 140ºF~212ºF), ±2% (100ºC~500ºC / 212ºF~932ºF) 10:1
0.1ºC / 0.1ºF 500ms
0.95 fixed 6 sec. Yes Yes Yes 156 x 100 x 32 mm (6.14” x 3.94” x 1.26”) 135g (0.3lbs)
To measure a temperature, point the unit at the target you want to measure, pull the trigger and hold. Be sure to consider the target area inside the angle of vision of this instrument. The single spot of laser is used for aiming only.
The unit is powered by 9V battery and displays temperatures in either ˚C or°F .
The user has to replace the battery when the battery voltage drops bellow the voltage for reliable operation and at the same time the low battery symbol will appear.
Battery Low
Lasser ON/OFF Indication
Lasser ON/OFF Switch
SCAN / HOLD
Temperature Display
/ Switch
/ Indication