Rosenlew RL520 User Manual

Type H20 / 60 821 2660-01
ENGLISH
miniBar
INSTRUCTIONS for USE
INSTALLATION INSTRUCTIONS
T.B. 04/2005 MB
HiPro Vision
2
1.0 INTRODUCTION 3
2.0 FOR YOUR SAFETY 3
2.1 Warnings and Safety Advice 3
2.2 Coolant 3
3.0 WARRANTY AND 3 CUSTOMER SERVICE
4.0 INSTALLATION 4
4.1 The Purpose of this Manual 4
4.2 Tools/Materials Required 4
4.3 Unpacking 4
4.4 Cleaning 4
4.5 Installation 5
4.6 Securing 6
4.7 Connecting the Device to the 6
Electricity Supply
4.8 Changing the Sliding Hinge 8
4.9 Changing the Doorhang 9
4.10 Decor Panel 10
5.0 INSTRUCTION FOR USE 11
5.1 Initial Operation 11
5.2 Temperature Control 11
5.3 Automatic Defrost Function 11
5.4 Leakage Detection 11
5.5 Postioning the Storage Rack 12
5.6 Interior Light 12
5.7 Door-opening Control Device 12
5.8 Check List 13
5.9 Technical Data 14
5.10 Spare Parts 14
5.11 Environmental Advice 15
5.12 Disposal 15
5.13 Energy Saving Tips 15
5.14 Declaration of Conformity 15
TABLE OF CONTENTS
Model No.
Product No.
Serial No.
These operating instructions should be kept in a safe place. If this device is passed on, please include these operating instructions with it.
Warning
Attention
Information
Environmental Advice
3
INTRODUCTION
You have made an excellent choice by choosing the Dometic miniBar. We are convinced that you will be satisfied with your new appliance in every way. Silent in operation because of the Absorption principle, the miniBar fulfils high quality standards and guarantees an efficient use of resources and energy during its entire working life, i.e. during manufacturing, use and disposal. Please study the installation and operating instructions carefully before attempting to operate the miniBar.
FOR YOUR SAFETY
Warnings and Safety Advice
In the interests of children's safety:
When disposing of the refrigerator, remove all doors and leave the shelves inside. This prevents children from being accidentally trapped or suffocated in the refrigerator.
Never open the cooling unit - it is under high pressure. Never store explosive substances, such as lighter fuel, petrol, ether or
similar products in the miniBar.
The minibar is not suitable for the proper storage of medications. The miniBar must be installed in such a way that accidental contact with
the cooling unit (which heats up when in use) is impossible.
The appliance has to be connected to a properly earthed socket in line
with the relevant valid country regulations.
Servicing must only be carried out by authorised service personnel.
Coolant
Ammonia is used as a coolant. This is a natural compound also used in household cleaning agents (1 litre of Salmiak cleaner contains up to 200g of ammonia - about twice as much as is used in the refrigerator). Sodium chromate is used for corrosion protection (1,8% of the coolant). If a leak occurs (which can be easily detected due to the unpleasant smell):
Switch the device off (pull mains plug, if applicable); Ventilate room thoroughly. Inform hotel personnel.
For the safety of hotel guests and personnel, it has been established by inspectors that the coolant poses no threat to health.
WARRANTY AND CUSTOMER SERVICE
Warranty arrangements are in accordance with EC Directive 44/1999/CE and the normal conditions applicable for the country concerned. For warranty or other servicing, please contact our Dometic service department. Any damage due to improper use is not covered by the warranty. The warranty does not cover any modifications to the appliance or the use of non-original Dometic parts; the warranty does not apply if the installation and operating instructions are not adhered to and no liability shall be entertained. Parts can be ordered throughout Europe from our Dometic service department. When contacting customer service, please always state model, product number,
11..00
22..00
2.1
33..00
2.2
4
MLC-Code and serial number ! You can find this information on the model label inside the device.
INSTALLATION
The Purpose of this Manual
The manual shows you how to:
install the miniBar correctly. operate the miniBar correctly. guarantee the miniBar´s correct maintenance and functioning. deal with faults by yourself.
Tools / Materials Required
You will need the following tools for initial operation:
Unpacking
Check during unpacking that the device is defect-free.
Report transport damage to the transport company within 48 hours. Check that the voltage noted on the model label corresponds to the
mains voltage.
Depending on the model, the following parts can be found in the miniBar :
Cleaning
Before operating the miniBar, we recommend you clean it both inside and outside.
Use a soft cloth, lukewarm water and a mild detergent. Following this, wash out the miniBar using clean water and dry thoroughly. At annual intervals, remove dust from fridge aggregate using a brush or
soft cloth.
AATTTTEENNTTIIOONN
To prevent material damage:
Do not use soap or detergents which are harsh, coarse or which contain
soda.
Keep the door seal free from oil and grease. The cylinder locks have been lubricated in the factory to be long-lasting.
4.1
4.2
4.4
44..00
4.3
mild detergent
e.g.
HHiiPPrroo 33000000
2x
sliding hinge
Special Equipment
IR-transmitter
Reflector
5
Installation4.5
1. The refrigerator must be level both directions.
2. There should be 20mm clearance to the wall.
3. Ventilation must be provided as shown in alternatives A, B, C or D.
4. The ventilation duct must at least measure 105mm x the wid
th of the refrigerator.
5. Only the entire cooling unit must project into the duct as shown.
6 Air p
assing through the duct must not be
preheated by any source of heat.
7. Ventilation grills, if used, must have openings of at least 200cm² each.
Please follow the installation details below carefully. Guarantee is valid for products installed as described only.
IMPORTANT:
200 cm²
20 mm
The mains plug/socket must be freely accessible once the miniBar has been installed.