Rosemount Analytical TUpH 396, TUpH 396P, TUpH 396R Product Data Sheet

Retraction/Submersion/Insertion pH/ORP Sensor
• MINIMUM SENSOR MAINTENANCE due to patented TUpH reference technology1which ensures steady pH signal when sensor is coated.
• OPTIMUM VERSATILITY by providing various mounting options. Also can be used with all Rosemount Analytical and other manufacturers’ instruments.
• FIELD PROVEN ACCUGLASS
2
pH glass formulations minimize glass cracking, resulting
in enhanced performance and increased life.
• MAXIMUM SENSOR LIFE because of secondary helical reference pathway
3
which hinders
reference poisoning.
Product Data Sheet
PDS 71-TUpH
September 1999
Models 396/396P/396R
MODEL 396:
A LARGE SELF CLEANING OPTIONAL FLAT OR STANDARD HEMI glass bulb electrode in a stain­less steel body, completely sealed by EPDM to eliminate process intrusion.
MODEL 396P:
A RUGGED THREADED POLYPROPYLENE BODY for maximum chemi­cal resistance and completely sealed to eliminate process intrusion.
MODEL 396R:
A TITANIUM RETRACTABLE BODY for insertion depths up to 27 inch­es and easy sensor removal under pressure without process shut­down (ball valve kit shown can be purchased separately).
1
May be protected by U.S. Patent No. 5,152,882, Foreign Patent Pending.
2
ACCUGLASS and TUpH are trademarks of Rosemount Analytical.
3
U.S. and Foreign Patents Pending.
NOW OFFERING MAXIMUM PRESSURE SPECIFICATIONS
of 150 psig (1136 kPa) at 100°C (212°F) ON ALL THREE MODELS
OPTIONAL FLAT BULB
STANDARD HEMI BULB
2 Rosemount Analytical
FEATURES AND APPLICATIONS
Rosemount Analytical sets a new industry standard for the life expectancy of pH and ORP sensors with the introduction of our TUpH Sensors. These low maintenance, disposable sensors offer long life and high performance in the measurement of pH in aque­ous solutions in pipelines, open tanks or ponds.
The TUpH Sensors feature a patented large area polypropylene reference junction for maximum resist­ance to process coatings, generally found in dirty, high solid applications. In addition, the patented secondary helical reference pathway serves as added protection from poisoning ions.
Our TUpH Sensors also feature a standard 1 in. outer diameter for versatile mounting in flow through, inser­tion or submersion pH and ORP applications.
The Model 396 Sensor is specifically designed for improved life in harsh, dirty, and abrasive applications such as lime slurry waste treatment, paper machine headbox and pigment/dye applications, where large quantities of suspended solids are present.
The Model 396 is available with custom glass elec­trodes, optional flat or standard hemi glass pH bulb, to best meet your application needs. Flat glass is advantageous in abrasive or coating applications that etch or build up on glass respectively. In coating appli­cations, such as slurries, the flat surface allows the process flow to act as a scrubbing agent to reduce coating and maintenance whereas in abrasive appli­cations pitting from silicates and other similar materi­als is minimized by the flat surface to provide longer life. The hemi bulb is ideal for general purpose use and for those processes requiring greater accuracy over the entire pH range.
The sensor is housed in a stainless steel body with EPDM seals. The simplified construction, designed with user convenience in mind, does not require elec­trolyte replenishment or any component replace­ment. The Model 396 also features a large glass bulb for increased resistance to high temperature and other effects of aging for longer life.
The Model 396 is not available with an integral pre­amplifier. The preamplifier must be in a remote loca­tion or integral to the analyzer/transmitter. Therefore, the Model 396 is compatible with all Rosemount Analytical and other manufacturers’ instruments.
The Model 396P Sensor is specifically designed for improved life in harsh, dirty applications, such as sour water waste treat­ment and scrubbers, where a high performance, low maintenance, disposable sensor is required.
The sensor is available in two configurations: the stan­dard shrouded tip, in which the pH glass is completely recessed within the reference junction for abrasive or rough applications, and the optional slotted tip with a partially exposed pH glass for viscous or low flow applications.
The Model 396P features a titanium solution ground, constructed in an annular design around the pH/ORP electrode. The solution ground provides advanced sensor diagnostics for preventative maintenance when used with the Models 54 pH/ORP analyzer, 1054B pH/ORP analyzer, and 3081 pH/ORP transmitter. In addition, the Model 396P sensor can be used with most non-diagnostic Rosemount Analytical and other manufacturers’ instruments.
The sensor is housed in a molded polypropylene body with EPDM seals, making it virtually indestructible and chemically resistant. Complete encapsulation elimin­ates leakage or high humidity problems traditionally found in other pH/ORP designs. The simplified con­struction, designed with user convenience in mind, does not require electrolyte (KCl) replenishment or any high maintenance troubleshooting procedures.
The Rosemount Analytical Model 396P is available with an optional integral preamplifier to convert the high impedance pH or ORP mV signal into a stable, noise-free signal with transmission capability of up to three miles.
Percent Linearity
396 396 396P 396R
pH Range GPHT Hemi GPHT Flat GPLR Hemi GPLR Hemi
0-2 pH 94% 95% 94% 94%
2-12 pH 99% 99% 97% 97%
12-13 pH 97% 96% 98% 98%
13-14 pH 92% _ 98% 98%
The Model 396R Sensor is specifically
designed for improved life in harsh, dirty appli­cations where a sepa­rate sample stream is difficult to provide and greater insertion depths are required. It is designed for use with a 1-1/4 in. or 1-1/2 in. ball valve for hot tap installation.
The Model 396R is constructed of molded polyprop­ylene housed in a titanium tube with EPDM seals to provide maximum chemical resistance. The sensor also features a titanium solution ground for advanced sensor diagnostics when used with the Model 54 or Model 3081 pH/ORP Analyzer/Transmitter. These
Rosemount Analytical 3
advanced sensor diagnostics provide preventative maintenance by notifying the operator of the need for replacement and cleaning of an aged or fouled sensor, thus allowing continuous optimum performance.
The sensor also features a slotted tip for protection from breakage while allowing the process to flow by the glass electrode for accurate and reliable pH measurement.
The Model 396R is only available without an integral preamplifier and has 15 ft or 9.5 in. of integral high qual­ity 9 conductor cable. The preamplifier must be housed in a remote location or in a junction box kit for attach­ment at the rear, cable end of the sensor (order sepa­rately) or must be integral to the Analyzer/Transmitter. The Model 396R is compatible with all Rosemount Analytical and other manufacturers’ instruments.
SPECIFICATIONS
MODEL 396 MODEL 396P MODEL 396R
Measurements and Ranges pH: 0-14 pH: 0-14 pH: 0-14
ORP: -1500 to 1500 mv ORP: -1500 to 1500 mv
Available pH ACCUGLASS GPHT hemi bulb or GPLR hemi bulb GPLR hemi bulb
Types GPHT flat bulb
Wetted Materials 316 SST, Polypropylene, Titanium, Polypropylene, Titanium, Polypropylene,
EPDM, glass EPDM, glass: EPDM, glass:
platinum (ORP only) platinum (ORP only)
Process Connection None, use 1 in. NPT process 1 in. MNPT front and rear None, use 1-in. process connector
connector, PN 23166-00 or facing threads or ball valve kit (1-1/2 in. 23166-01 (sold separately) or - 1/4 in.) (sold separately)
Temperature Range 0-100°C (32-212°F) 0-100°C (32-212°F) 0-100°C (32-212°F)
Pressure Range-
100-1136 kPa (0-150 psig) 100-1136 kPa (0-150 psig) 100-1136 kPa (0-150 psig)
Hemi bulb
Pressure Range-
100-790 kPa (0-100 psig)
Flat bulb
Maximum Pressure at Not Applicable Not Applicable Code 21: 542 kPa (64 psig)
Retraction or Insertion Code 25: 343 kPa (35 psig)
Minimum Conductivity 75 µS/cm, nominal 75 µS/cm, nominal 75 µS/cm, nominal
100 µS/cm 100 µS/cm 100 µS/cm
Integral Cable 15 ft coaxial with BNC Code 01: 25 ft 11 Standard 15 ft coaxial
conductor Code 60: 9.5 in. coaxial
Code 02: 15 ft coaxial with BNC
Code 61: 9.5 in. coaxial
Preamplifier Options Remote Remote or Integral Remote
Weight/Shipping Weight 0.45 kg/0.9 kg (1 lb/2 lb) 0.45 kg/0.9 kg (1 lb/2 lb) Sensor: Code 21:
0.9 kg/1.40 kg (2.0 lb/3.0 lb) Code 25: 1.40 kg/1.80 kg
(3.0 lb/4.0 lb)
Ball Valve PN 23240-00:
2.25 kg/3.20 kg (5.0 lb/7.0 lb) Junction box; 1.40 kg/1.80 kg
(3 lb/4 lb)
DIMENSIONAL DRAWINGS: Model 396P
4 Rosemount Analytical
DIMENSIONAL DRAWINGS: Model 396 with Optional Connector
168.28
6.63
28.7
1.13
25.4
1.0
53.98
2.13
108
4.25
OPTIONAL CONNECTOR ASSY P.N. 23166-00/-01
CAUTION LABEL
INSERTION
SUBMERSION
Standard Hemi-bulb pH ELECTRODE
Standard Hemi-bulb pH electrode with slotted tip
Optional Flat Bulb pH Electrode
O.D. RETRACTION STOP COLLAR
O.D.
HOUSING STAINLESS STEEL TYP.
CAUTION LABEL
1”1” NPT MALE CONNECTOR
HEX NUT 316 SST TYP.
CABLE
CABLE
MILLIMETER
INCH
MILLIMETER
INCH
Metal Process Connector PN 23166-xx (xx = 00 for 316 SST and xx = 01 for titanium) can be used for insertion or submersion Model 396 sensor connection to 1-inch tee fittings. It also must be used to connect Model 396R to ball valve PN 23240-00 or directly to the process.
The metal process connector gives the sensor various inser­tions depths, depending on where the user locates the com­pression fitting. Also the threads can be switched to face the cable end of the sensor for connection to submersion pipes.
DIMENSIONAL DRAWINGS: Model 396R with Optional Ball Valve PN 23240-00
DIMENSIONAL DRAWINGS: Model 396R with Optional Ball Valve PN 23654-00
Rosemount Analytical 5
MILLIMETER
INCH
MILLIMETER
INCH
Ball Valve Kit (PN 23240-00) used with
Model 396R retractable sensor
A process connector (PN 23166-00 or
-01) must be used to connect the sensor to Ball Valve Kit 23240-00. Process
connector can be purchased separately.
TYPICAL FLOW THROUGH INSERTION INSTALLATION
(sensor must be installed at least 10° above the horizon)
FLOW THROUGH TEE WITH ADAPTER (PN 915240-04) FOR MODEL 396P
1-1/2” PIPE “Y”
1-1/2” X 1” Reducing Bushing
1-1/2” X 1”
Reducing
Bushing
1-1/2” X 1”
Reducing
Bushing
1-1/2” Pipe Tee PN 2002011
1-1/2 in. Pipe Tee PN 2002011
PIPE “Y”
INSTALLATION
SHOWN
STRAIGHT
FLOW
SHOWN
FLOW
ANGLE
FLOW
SHOWN
MOUNTING AND ACCESSORIES
SENSOR CABLE
ADAPTER, RETROFIT PN 33211-00 (INCLUDED IN PN 915240-04)
“O” RING MUST BE IN PLACE PRIOR TO USE
1” FNPT 2 PLACES
2” SCHED. 80”T”
PRESSURE/TEMPERATURE 60 PSIG AT 120° F 514 kPa AT 49° C
174.7
6.88
76.2
3.0
38.1
1.5
APPROX.
190.6
7.5
MILLIMETER
INCH
6 Rosemount Analytical
NOTE: Other flow through tees are available with 3/4 in. or 1 1/2 in. FNPT. See page 10, mounting accessories, for more details
LOW FLOW CELL PN 23728-00 FOR MODELS 396P-41, 396
Rosemount Analytical 7
MILLIMETER
INCH
JET SPRAY CLEANER PN 12707-00 FOR MODEL 396P
JET SPRAY CLEANER SHOWN WITH
TUpH MODEL 396P pH SENSOR
JUNCTION BOX AND
PIPE MOUNTING ACCESSORY
HANDRAIL MOUNTING
ACCESSORY (P/N 11275-01)
SUBMERSION INSTALLATIONS SUBMERSION INSTALLATIONS
8 Rosemount Analytical
MILLIMETER
INCH
MILLIMETER
INCH
MILLIMETER
INCH
PN 9330022
INSERTION ACCESSORY
FOR MODEL 396P
The Insertion Adapter mounts Model 396P into a 1-1/2 inch NPT process pipe. Unscrewing the hex nut allows easy sensor removal without twisting the sensor cable.
Rosemount Analytical 9
MODEL
396 TUpH INSERTION/SUBMERSION STAINLESS STEEL pH SENSOR
CODE ANALYZER/TC COMPATIBILITY (Required Selection)
50 For use with Models 1181, 1050, 1003 (3 K TC)
54 For use with Models 54, 1054, 1054A, 1054B, 2054, 2081, 2700, 81, 3081, 4081 and SCL-P (Pt 100 RTD)
CODE OPTIONAL OPTIONS
71 GPHT Flat bulb
ORDERING INFORMATION
The Model 396 pH Sensor features your selection of glass electrode type, either the standard hemi bulb or the
optional flat glass electrode combined with the coating resistant, polypropylene reference with gel filled elec­trolyte. The sensor is housed in a stainless steel body with an optional 1 in. MNPT threaded connector suitable for insertion, submersion, or flow through installations. The Model 396 is only available without an integral preamplifi­er and has 15 ft of cable. Automatic temperature compensation is standard 3 K Balco or Pt 100 RTD.
1. Process Connector Accessories (required for all first time installations)
Choose one: PN 23166-00, 316 SST, 1 in. x 1 in. NPT process connector
PN 23166-01, Titanium, 1 in. x 1 in. NPT process connector
PN 9510066, Nylon, 1 in. x 1 in. NPT process connector
2. Mounting Accessories (optional)
Choose one: PN 915240-03 PVC flow through tee, 3/4 in. NPT process connection
PN 915240-04 PVC flow through tee, 1 in. NPT process connection
PN 915240-05 PVC flow through tee, 1-1/2 in. NPT process connection
3. Junction Boxes (optional, recommended for sensor to analyzer distances of more than 15 ft)
Remote Junction Boxes
Choose one: PN 23555-00 includes preamplifier for Models 54, 81, 3081, 4081
PN 23309-03 and PN 22698-02 plug-in preamplifier for Model 1181Analyzer
PN 23309-04 and PN 22698-03 plug-in preamplifier for Models 1054 series, 2054, 2081 Analyzers
PN 23054-03 includes preamplifier for Solu Cube Model 2700
4. Extension cables (used with remote junction boxes)
Choose one: PN 23646-01, 11 conductor, shielded, prepped
PN 9200273, 11 conductor, shielded, unprepped
5. Wiring Aids
Choose one: PN 9120531 BNC splitter, used in place of BNC coax prepping for connections to junction box (PN 23555-00);
Models 1181, 1054, 2081, 54, 81, 3081, 4081; SoluComp (SCL-P-014); and Model 2700 Preamplifier
(PN 23054-03)
NONE: No wiring aids required for other options not listed above.
FOR FIRST TIME 396 INSTALLATIONS, ROSEMOUNT ANALYTICAL RECOMMENDS USING THE FOLLOWING GUIDE:
396 - 54 EXAMPLE
The Model 396P Sensor is housed in a molded reinforced polypropylene body with 1 in. MNPT threads suitable for insertion, submersion or flow through installation. The sensor includes a general purpose pH electrode or a platinum ORP electrode, a patented reference junction and a solution ground.The Model 396P comes standard with a recessed electrode; an optional slotted tip is also available. In addition, the 396P features an optional inte­gral hermetically sealed preamplifier and 15 ft or 25 ft cable lengths. Automatic temperature compensation, Pt 100 or 3K Balco, is standard with the Model 396P.
MODEL
396P TUpH INSERTION/SUBMERSION POLYPROPYLENE pH/ORP SENSOR
CODE PREAMPLIFIER/CABLE (Required Selection)
01 With integral preamplifier, 25 ft cable
02 Without integral preamplifier, 15 ft cable
CODE MEASURING ELECTRODE TYPE (Required Selection)
10 GPLR hemi bulb, General Purpose Low Resistivity (0-14 pH)
12 ORP
CODE ANALYZER/TC COMPATIBILITY (Required Selection)
50 For Models 1181 (3K TC)
54 For Models 1054, 1054A, 2054, 2081; 2700-Code 02 only (Pt 100 RTD)
55 For Models 54, 3081, 81, 4081 (PT-100 RTD)
396P - 01 - 10 - 55 EXAMPLE
NOTE: The Model 396P is also compatible with Models 1003 (option 02-50 only) and SCL-P/Q and (option 02-54 only).
CODE OPTIONAL OPTIONS
41 Slotted Tip
10 Rosemount Analytical
1. Mounting Accessories (optional)
Choose one: PN 915240-03, PVC flow through tee, 3/4 in. NPT process connection
PN 915240-04, PVC flow through tee, 1 in. NPT process connection
PN 915240-05, PVC flow through tee, 1-1/2 in. NPT process connection
PN 23728-00, acrylic low flow cell
PN 2002011, 1-1/2 in. CPVC tee with 1-in. FNPT connection
PN 11275-01, sensor handrail assembly
2. Junction Boxes (optional)
Remote Junction Boxes (used with option -02 sensors, for sensor to analyzer distances of more than 15 ft)
Choose one: PN 23555-00 includes preamplifier for Models 54, 81, 3081, 4081
PN 23309-03 and PN 22698-02 plug-in preamplifier for Model 1181Analyzer
PN 23309-04 and PN 22698-03 plug-in preamplifier for Models 1054 series, 2054, 2081 Analyzers
PN 23054-03 includes preamplifier for Solu Cube Model 2700
Choose one: PN 9120516 BNC Adapter for use with remote junction boxes PNs 23309-03, 23309-04
Remote Junction Box (used with option -01 sensors)
Choose one: PN 23550-00 cable extension board
3. Extension cables (used with remote junction boxes)
Choose one: PN 23646-01, 11 conductor, shielded, prepped
PN 9200273, 11 conductor, shielded, unprepped
FOR FIRST TIME 396P INSTALLATIONS, ROSEMOUNT ANALYTICAL RECOMMENDS USING THE FOLLOWING GUIDE:
ORDERING INFORMATION
Rosemount Analytical 11
CODE OPTIONAL OPTIONS
60 9.5 in. Cable with BNC (for use with Model 1181, 1054 series, 2054, 2081 sensor head J-Boxes)
61 9.5 in. Cable no BNC (for use with Model 54, 81, 3081, 4081 sensor head J-Boxes; not valid w/option 50)
MODEL
396R TUpH RETRACTABLE pH/ORP SENSOR
CODE MEASURING ELECTRODE TYPE (Required Selection)
10 GPLR hemi bulb, General Purpose Low Resistivity (0-14 pH)
12 ORP
CODE SENSOR LENGTH (Required Selection)
21 21 in.Titanium Tube
25 36 in.Titanium Tube
CODE ANALYZER/TC COMPATIBILITY (Required Selection)
50 For Models 1181 (3K TC)
54 For Models 1054, 1054A, 1054B, 2054, 2081,54, 3081, 4081, 81, SCL-(P/Q), 2700 (Pt 100 RTD)
396R - 10 - 21 - 54 EXAMPLE
ORDERING INFORMATION
The Model 396R Sensor is housed in a titanium tube with a patented polypropylene reference junction and tita- nium solution ground for use with a ball valve (order separately) for hot tap applications. The sensor features a shrouded glass/platinum electrode and Pt 100 or 3K temperature compensation. The 396R sensor is only avail­able without a preamplifier and has 15 ft or 9.5 in. of integral cable. Junction box kits with preamplifiers must be ordered separately if the analyzer/transmitter does not have an integral preamplifier within 15 ft of the probe. Process connector and ball valve assemblies must be ordered separately.
1. Retractable Mounting
1A. Choose one (required for all first time installations, except as noted):
PN 23166-00 1 in. x 1 in. NPT process connector, 316 SST
PN 23166-01 1 in. x 1 in. NPT process connector, Titanium
1B. Choose one:
PN 23240-00 1-1/2 in. ball valve assembly, 316 SST
PN 23654-00 1- 1/4 in. ball valve assembly, 316 SST (process connector not needed)
2. Junction Boxes (Optional, Choose either Sensor Head or Remote)
Sensor Head Junction Boxes (used with option -60 or -61 sensors)
Choose one: PN 23709-00 includes preamplifier for Models 54, 81, 3081, 4081
PN 23708-01 includes preamplifier for Models 1054 series, 2054, 2081
PN 23707-00 includes preamplifier for Model 1181
Remote Junction Boxes (used with standard 15 ft. cable length sensor)
Choose one: PN 23555-00 includes preamplifier for Models 54, 81, 3081, 4081
PN 23309-03 and PN 22698-02 plug-in preamplifier for Model 1181Analyzer
PN 23309-04 and PN 22698-03 plug-in preamplifier for Models 1054 series, 2054, 2081 Analyzers
PN 23054-03 includes preamplifier for Solu Cube Model 2700
3. BNC Adapter
Choose one: PN 9120516 BNC Adapter for use with remote junction boxes PNs 23309-03 or 23309-04
Order option -60 (standard with BNC connector) for PN 23707-00 or 23708-01 Sensor head junction boxes
4. Extension cables
Choose one: PN 23646-01, 11 conductor, shielded, prepped
PN 9200273, 11 conductor, shielded, unprepped
FOR FIRST TIME 396R INSTALLATIONS, ROSEMOUNT ANALYTICAL RECOMMENDS USING THE FOLLOWING GUIDE:
OTHER ACCESSORIES
NOTE: All accessories above can be used with the Models 396 , 396P or 396R.
1
Kynar is a registered trademark of Elf Atochem North American, Inc.
2
Teflon is a registered trademark of E.I. du Pont de Nemours and Company.
PART DESCRIPTION 22698-00 Preamplifier plug-in for junction box, for Model 1003, 22698-02 Preamplifier plug-in for junction box, for Models 1181, 1050 22698-03 Preamplifier plug-in for junction box, for Models 1054A/B, 2054, 2081 22743-01 Pt100 preamplifier for Model 1181 22744-01 3K Preamplifier for Model 1181 23557-00 Preamplifier for junction box for Models 54, 3081, 81, 4081 33046-00 Ferrule, 1 in., split 316SS 9310096 Nut, swage, 1 in. 316SST 9210012 Buffer solution, 4.01 pH, 16 oz 9210013 Buffer solution, 6.86 pH, 16 oz 9210014 Buffer solution, 9.18 pH, 16oz R508-160Z ORP solution, 460 mv ± 10 at 20°C 9550167 EPDM O-ring for Process Connector (PN 23166-00 or 23166-01) 12707-00 Jet Spray Cleaner
Rosemount Analytical Inc. Uniloc Division
2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 863-1181 http://www.RAuniloc.com
© Rosemount Analytical Inc. 1998
Credit Cards for U.S. Purchases Only.
The right people, the right answers, right now.
ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE
http://www.RAuniloc.com
TYPICAL MOUNTING CONFIGURATIONS FOR MODEL 396R
UNILOC DIVISION
CUSTOMER SUPPORT CENTER
1-800-854-8257
Loading...