Rosemount Analytical TF396 Specifications

• NO GLASS TO BREAK due to use of Ion-selective field effect transistor.
• REDUCED DRIFT with TUpH reference technology.
• SUITABLE FOR USE AT COLD TEMPERATURES with continued rapid response and accuracy.
• REDUCED CALIBRATION FREQUENCY due to increased sensor stability.
• QUICK CABLE-TO-SENSOR RELEASE provided by waterproof electrode/cable connector.
• MINIMUM SENSOR MAINTAINANCE due to TupH reference technology which ensures continued reference performance when the sensor becomes coated.
• OPTIMUM VERSATILITY by providing various mounting options.
• BUILT-IN CABLE CAP PREAMPLIFIER allows use with most pH instruments.
• AVAILABLE WITH 316SS TRI-CLOVER
®
FITTING.
Product Data Sheet
PDS 71-TF396/rev.I June 2012
Model TF396
Model TF396 with Mating Cable
Model TF396
with Tri-Clover®Fitting
NON-GLASS pH SENSOR FOR SUBMERSION/INSERTION
FEATURES AND APPLICATIONS
The ion-selective field effect transistor (ISFET) pH electrode provides a stable pH measurement. Its rate of response can be ten times faster than glass electrodes, enabling better process control. Its short response time and increased sta­bility at low temperatures make it suitable for use in cold processes like brine or water for cooling. Aging effects caused by temperature fluctuations or large changes of process pH are greatly reduced, providing longer intervals between calibration and maintenance of the sensor.
Because there is no glass bulb, it can be used in many applications that restrict or prohibit pH glass electrodes due to the risk of broken glass getting into the process. It may also provide longer sensor life in processes that will break or crack pH glass bulbs. By allowing direct installation into the process, costs for laboratory analysis of sample lines are greatly reduced.
The TUpH Reference technology includes a large area ref­erence junction for minimum maintenance requirements. The reference junction provides an electrical connection between the reference electrode and the sample, and helps maintain a stable reference potential, regardless of the change in sample pH. The TUpH reference electrode junc­tion (the entire plastic tip surrounding the ISFET electrode) maintains a steady reference signal, even in dirty applica­tions, by resisting plugging (a common cause of pH signal drift). This large reference junction area (400 times greater than typical teflon or ceramic junctions) is made of micron­sized reference pathways allowing for ionic exchange but preventing plugging by larger particles and will continue to send a steady pH signal, even in the dirtiest of applications. The field-proven TUpH reference junction technology results in greatly reduced maintenance requirements.
continued on page 2
®
Tri-Clover is a registered mark of Alfa Laval Corporate AB
2 Rosemount Analytical
FEATURES AND APPLICATIONS (continued)
The TUpH helical reference pathway resists reference poisoning. Ions diffuse through the reference pathways and a charge is passed to the reference element. The reference element must be protected from contamination by poisoning ions such as sulfide, mercury, cyanide, and ammonia that will cause reference drift and offsets. The TUpH sensor's long internal reference pathway hinders the contaminants' migration to the reference element thereby providing an increased sensor life.
All TUpH sensor models have been specifically designed for improved performance in harsh, dirty, or abrasive applications where large quantities of suspended solids are present.
The Model TF396 offers a watertight sensor-to-cable connector that prevents cable twisting and eliminates the need for rewiring when replacing the sensor. The sensor cable includes an inte­gral preamplifier cap with mating connector and is compatible with most Rosemount Analytical analyzers and transmitters.
SPECIFICATIONS
Measurement Range: 2-12 pH
Measuring element: ISFET
Repeatability: ±0.05 pH
Response time to pH change: 99% in 30 seconds step change
Wetted Materials: Code -01: Polypropylene, EPDM, Ryton, Silicon.
Code -02: 316SST, Titanium, Polypropylene, EPDM, Ryton, Silicon
Process Connections: Code -01: 1 in. MNPT front and rear facing threads
Code -02: 2 in. Tri-Clamp connection
Temperature Range: 0 to 100°C (32 to 212°F) @ 50 psig
Pressure Range: -10 to 100 psig (32 to 790 kPa [abs]) at 50°C
Minimum Process Conductivity: 100 µS/cm
Cable Lengths: 20 ft, 50 ft (6 m, 18 m)
Weight/Shipping Weight: 0.45 kg/0.9 kg (1 lb/2 lb)
MODEL TF396-01 DIMENSIONS
CONNECTION. PREAMP CAP ADAPTOR WITH CABLE PN 23991 -02 -01