Rosemount Analytical 499 Data sheet

Monochloramine Sensor
LIQ-PDS-499ACL-03
Product Data Sheet
July 2017
Rosemount
TM
499ACL-03
Monochloramine Sensor
The RosemountTM 499ACL-03 sensor is designed to measure monochloramine without the need for a sample conditioning system. These amperometric sensors are ideal for use in drinking water and wastewater applications.
Rosemount 499ACL-03 Monochloramine Sensor Rosemount 499ACL-03 Monochloramine Sensor
July 2017
Overview
A Simple Sensor Design
Measure monochloramine without having to deal with
messy reagents or expensive sample conditioning systems.
Integral Pt-100 RTD allows for automatic temperature
compensation.
Operates in samples up to 50 °C (122 °F).
Measures 0 to 15 ppm monochloramine.
Ease of Maintenance and Installation
1 in. MNPT process connections suitable for mounting in a
low flow cell installed in a sidestream sample or directly in a chlorine contact basin.
Replacing the membrane and electrolyte solution is fast
and easy and requires no special tools or fixtures.
Variopol (VP6) cable connection option, for quick cable-
to-sensor release, eliminates cable twisting.
Contents
Ordering Information ..................................................................................................................................................................... 3
Specifications ................................................................................................................................................................................. 4
Dimensional Drawings ................................................................................................................................................................... 5
Accessories .................................................................................................................................................................................... 7
2
www.Emerson.com/RosemountLiquidAnalysis
July 2017
Ordering Information
Rosemount 499ACL-03 monochloramine sensors are available with either a 25 ft integral cable or a Variopol (VP6) quick disconnect connection for use with VP6 interconnecting cables (sold separately). Three replacement membrane assemblies, three O-rings, and a 4 oz (125 mL) bottle of electrolyte solution are provided with each sensor.
Table 1. Rosemount 499ACL-03 Monochloramine ordering information
Model Sensor Type
499ACL Chlorine Sensor
Sensor Type
03 Monochloramine
Transmitter Compatibility
54 For use with Rosemount 1056, 56, 1066, and 5081 transmitters
Options
Cable Options
- No selection - standard 25 ft cable
60 Optimum EMI/RFI protected 25 ft cable
VP Variopol (VP6) cable connection
Typical Model Number: 499A CL-01-54-60
www.Emerson.com/RosemountLiquidAnalysis 3