FEATURES AND APPLICATIONS (cont.)
A choice of pH glass electrodes is available to best
meet various application needs. Four types are avail-
able: hemi bulb, flat bulb, HF resistant, and Hi pH glass.
The A
CCUGLASS hemi bulb is the standard glass offered
on both models and can be used for most applications.
The hemi bulb is also found on the HF resistant and Hi pH
glass options. The A
CCUGLASS flat glass option can be
used in abrasive or coating applications that etch or build
up on glass, respectively.
NEW - SMART is standard option. A preamplifier converts
the high impedance pH signal into a stable, noise-free
signal and must be used with all pH sensors. The Model
399/399VP offers the Models 399-10, 399-14, 399-34 and
399VP (-70) with an integral SMART preamplifier. Other
Models can use a remote preamplifier, integral to the
analyzer/transmitter or in a remote junction box. All preamplifiers have a transmission capability of up to three
miles.The Rosemount Analytical preamplifier method has
become the industry standard for pH/ORP measurement
reliability.
Model 399VP is offered with a watertight sensor-tocable connector which eliminates re-wiring and cable
twisting when replacing sensors. The Variopol VP multi-
ple pin connector is an integral part of each sensor model
and uses a mating VP cable; see page 5 for example.
Once the cable is installed and wired to the analyzer,
sensors are easily replaced without replacing the cable
and without rewiring the analyzer. Also the cable can be
disconnected from the sensor before removal from the
process which eliminates cable twisting. VP8 cable
assembly works with both VP8 and VP6 sensor connector.
Models 399 and 399VP are housed in a molded Tefzel
body with Viton o-rings, making each sensor virtually
indestructible and chemically resistant. Complete
encapsulation eliminates leakage or high humidity problems traditionally found in other pH/ORP designs. The
simplified construction, designed with user convenience
in mind does not require electrolyte (KCl) replenishment
or any high maintenance troubleshooting procedures.
Installation is easily achieved through the wide variety
of mounting configurations. Both Models feature 1 inch
(MNPT) front and rear facing connections for insertion,
submersion, or flow-through pH and ORP applications.
New options are available for special application
needs, including high purity/low conductivity water, heavy
reference poisoning, and continuous high or low temperature processes. Consult the factory or your local sales
representative for more details on these new options.
PHYSICAL PERFROMANCE AND
SPECIFICATIONS
Sensor Type:: General purpose 399, 399VP
Measured Range: pH: A
CCUGLASS 0-14
ORP: -1500 to +1500 mV
Percent Linearity Over pH Range:
Operating Temperature: 0° to 85°C (32° to 185°F)
Automatic temperature compensation 0° to 85°C (32°
to 185°F), Temperature compensation is not required
for 399 ORP when used with Models 1060, or 1181
ORP
Maximum Pressure: 790 kPa [abs] (100 psig) at 65°C (see
Graph 1 below)
Flow Rate: up to 2 ft/sec
Materials of Construction: Tefzel, glass, ceramic, & Viton
Materials of ORP: Platinum
Process Connections: 1 in. MNPT, 2 places
Integral Cable: 10 or 32 ft cable with integral preamp
(remote preamp) 10 ft cable with remote preamp
VP8 Cable: use PN 24281-00
Weight/Shipping Weight: 0.45 kg/0.9 kg (1 lb/2 lb)
• High pH glass provides greater accuracy over 12.5 pH
• HF glass provides improved resistance to hydrofluoric
acid up to 300 ppm
GPLR Hemi Bulb Flat Bulb
1-2 pH 94% 93%
2-12 pH 99% 98%
12-13 pH 97% 95%
13-14 pH 92% –
GRAPH 1. Pressure/Temperature Operating Range
for Models 399 and 399VP
2
Both models are combination sensors (pH, reference, and
temperature within sensor body) and measure pH or ORP
(Oxidation/Reduction Potential) of aqueous solutions in
pipelines, open tanks, or ponds. Models 399 and 399VP are
suitable for virtually all applications and are compatible with
Rosemount Analytical and other manufacturers’ instruments.