Rosemount 398/398VP/398R/398RVP TUpH pH sensors are robust sensors designed to meet a number of difficult application
requirements. Sensors feature a variety of options suited to meet a number of installation requirements and are ideal for use in dirty,
abrasive, coating, and high solid applications containing chlorine dioxide.
Rosemount 398/398VP sensors are housed in a titanium tube and constructed with a
Tefzel reference junction. Sensors can be used with a 1 inch MNPT process connector
(sold separately). Rosemount 398 sensors come standard with 15 ft. of integral cable.
Rosemount 398VP sensors are used with quick disconnect VP8 interconnecting cables
(sold separately).
Table 1. Rosemount 398 TUpH pH/ORP Sensor ordering information
ModelSensor type
398pH/ORP sensor
Measuring Electrode
10pH – GPHT Hemi Bulb Glass
12ORP
13pH – GPLR Flat Glass
O-ring Material
30EPDM
31Viton
32Kalrez
Temperature Element
503k Balco
54Pt-100
(1)
(2)
Cable Options
_No Selection - Cable with BNC
62Cable without BNC
(3)
Typical Model Number: 398-10-32-54-62
1.For use with legacy transmitter model Rosemount 1181. Not available with option -62.
2.For use with existing transmitter models Rosemount 1056, 1057, 56, 1066, and 5081. Also compatible with legacy transmitter models 54, 1054, 1055, 6081, 81,
2081, 3081, 4081, and XMT.
3.For use with existing transmitter models Rosemount 1056, 1057, 56, 1066, and 5081. Only available with option -54.
Table 2. Rosemount 398VP TUpH pH/ORP Sensor ordering information
ModelSensor type
398VPpH/ORP sensor
Measuring Electrode
10pH - GPHT Hemi Bulb Glass
12
13
O-ring Material
30EPDM
31Viton
32Kalrez
Temperature Element
503k Balco
54Pt-100
ORP
pH - GPLR Flat Glass
(1)
(2)
June 2017
Typical model number: 398VP-10-30-54
1.For use with legacy transmitter model Rosemount 1181.
2.For use with existing transmitter models Rosemount 1056, 1057, 56, 1066, and 5081. Also compatible with legacy transmitter models 54, 1054, 1055, 6081, 81,
2081, 3081, 4081, and XMT.
Rosemount 398R/398RVP sensors are offered in 21 inch and 36 inch titanium tube
sensor lengths. Sensors can be used with a ball valve (sold separately) for hot tap
applications. Rosemount 398 sensors come standard with 15 ft. of integral or 9.5 in.
cable for use with a sensor head junction box (sold separately). Rosemount 398RVP
sensors are SMART preamplifier optional and are used with quick disconnect VP8
interconnecting cables (sold separately).
Table 3. Rosemount 398R TUpH pH/ORP Sensor ordering information
ModelSensor type
398RpH/ORP sensor
Cell constant
10pH - GPHT Hemi Bulb Glass
12
ORP
13
pH - GPHT Flat Glass
O-ring Material
30EPDM
31Viton
32Kalrez
Temperature Element
54Pt-100
Cable Options
_No Selection - 15 ft. Cable with BNC
609.5 inch Cable with BNC
619.5 inch Cable without BNC
6215 ft. Cable without BNC
(1)
(1)
(2)
Typical Model Number: 398R-10-31-54-62
1.For use with sensor head junction boxes.
2.For use with existing transmitter models Rosemount 1056, 1057, 56, 1066, and 5081. Also compatible with legacy transmitter models 1055, 54e, 81, 3081, 4081,
and XMT.
Table 4. Rosemount 398RVP TUpH pH/ORP Sensor ordering information
ModelSensor type
398RVPpH/ORP sensor
Measuring Electrode
10pH - GPHT Hemi Bulb Glass
12
ORP
June 2017
13
pH - GPHT Flat Glass
Sensor Length
2121 in. Titanium Tube
2536 in. Titanium Tube
O-ring Material
30EPDM
31Viton
32Kalrez
Temperature Element
503k Balco
54Pt-100
55Pt-100
(1)
(2)
(3)
Preamplifier
_No Selection - No Preamplifier
70SMART Preamplifier
(4)
Typical Model Number: 398RVP-10-25-32-55-70
1.For use with legacy transmitter model Rosemount 1181.
2.For use with existing transmitter models Rosemount 1056, 1057, 56, 1066, and 5081. Also compatible with legacy transmitter models 54, 1054, 1055, 6081, 81,
2081, 3081, 4081, and XMT. Not available with option -70.
3.For use with existing transmitter models Rosemount 1056, 1057, 56, 1066, and 5081. Also compatible with legacy transmitter models 54, 1054, 1055, 6081, 81,
2081, 3081, 4081, and XMT. Only available for pH sensors with option -70.
4.Only available for pH sensors with option -55.
6
www.Emerson.com/RosemountLiquidAnalysis
Loading...
+ 12 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.