A robust pH sensor that meets steam sterilization requirements
The Rosemount 328A pH sensors are specifically built for service in applications that require repeated steam sterilization up to 130 °C.
Sensors are suitable for use in many food, beverage, and pharmaceutical applications.
Page 2
Rosemount 328A Steam Sterilizable pH sensor
Overview
June 2017
Rugged Sensor Design
Mechanical and thermal shock resistant special pH sensitive
glass membrane for extended sensor life in high temperature
sterilizations.
The Rosemount 328A pH sensor comes with 15 ft. of integral cable and features a
ceramic sensor body, double junction reference, and gelled reference electrolyte.
Sensors require standard insertion mounting hardware for installation (PN 22924-00;
sold separately).
Table 1. Rosemount 328A pH Sensor ordering information
ModelSensor type
328ApH Sensor
Cable Termination
07Spade Lug Connector
08None (Undressed)
Typical Model Number: 328A-07
www.Emerson.com/RosemountLiquidAnalysis
3
Page 4
Rosemount 328A Steam Sterilizable pH sensor
Specifications
Table 2. Rosemount 328A pH sensor specifications
Process Connections
Standard 12 mm insertion hardware (see Dimensional Drawing)
Sensitivity
± 0.02pH
Temperature/Pressure Rating
446 kPa abs at 130 °C (50 psig at 266 °F)
584 kPa abs at 80 °C (70 psig at 176 °F)
791 kPa abs at 40 °C (100 psig at 104 °F)
Cable
2-conductor, low-noise coax, 15 ft (4.5 m)
Weight/Shipping Weight
June 2017
100 gms/180 gms (.2 lb/1.0 lb)
Performance
In typical applications, the sensor will perform continuously for 50 steam sterilization cycles.
pH Range
1.67-4.01 pH96% linearity
4.01-12.099% linearity
12.0-13.0 pH97% linearity
Repeatability
± 0.05 pH
Automatic Temperature Compensation
Temperature compensation is generally not required since most applications operate very near pH 7 (isopotential point).
When temperature compensation is required a separate RTD can be used with compatible instruments.
Wetted Materials
Ceramic, silicone and glass
Recommended Accessories
PN 22924-0025mm Insertion Mounting Adapter Kit
4
www.Emerson.com/RosemountLiquidAnalysis
Page 5
June 2017
Rosemount 328A Steam Sterilizable pH sensor
Product Certifications
Please see online certificates for further details.
IECEx
Ex ia IIC T4 Ga (-20 °C ≤ Ta ≤ + 60 °C)
Per standards IEC60079-0: 2011, IEC 60079-11: 2011
ATEX
– II 1 G Ex ia IIC T4 Ga (-20 °C ≤ Ta ≤ +60 °C)
Per standards EN 60079-0: 2012 + A11:2013, EN 60079-11:2012
FM
Intrinsically Safe for use in Class I, II, and III, Division 1, Groups A, B, C, D, E, F, and G; Temperature Class T6 Ta = -20 °C to +60 °C
Intrinsically Safe for use in Class I, Zone 0, AEx ia IIC T6 Ta = -20 °C to +60 °C
Nonincendive for use in Class I, Division 2, Groups A, B, C, and D; Temperature Class T6 Ta = -20 °C to +60 °C
Suitable for use in Class II and III, Division 2, Groups E, F, and G; Temperature Class T6 Ta = -20 °C to +60 °C Hazardous (Classified)
Locations
IS/I,II,III/1/ABCDEFG/T6 Ta = 60 °C - 1400332; Entity; I/0/AEx ia IIC/T6 Ta = 60 °C - 1400332; Entity; NI/I/2/ABCD/T6 Ta = 60 °C;
S/II,III/2/EFG/T6 Ta = 60 °C
Per standards 3600:1998, 3610:2010, 3611:2004, 3810:2005
CSA
Intrinsically Safe and Non-Incendive:
Class I, Division 1, Groups ABCD; Class II, Division 1, Groups EFG; Class III; Class I, Division 2, Groups ABCD; Ex ia IIC; T6; Ambient
temperature rating -20 °C to +60 °C: (Simple Apparatus)
Per standards C22.2 No. 142 – M1987, C22.2 No 157 – M1992, CAN/CSA E60079-0:07, CAN/CSA E60079-11:02, UL 50:11th Ed., UL
508:17th Ed., UL 913: 7th Ed., UL 60079-0: 2005, UL 60079-11: 2002
www.Emerson.com/RosemountLiquidAnalysis
5
Page 6
Rosemount 328A Steam Sterilizable pH sensor
Dimensional and Installation Drawings
Figure 1. Dimensional drawing of Rosemount 328A and optional mounting adapter hardware kit
(PN 22924-00)
June 2017
6
www.Emerson.com/RosemountLiquidAnalysis
Page 7
June 2017
Rosemount 328A Steam Sterilizable pH sensor
Accessories
Table 3. Rosemount 328A pH Sensor accessories information