Rosemount Analytical 245 Specifications

Rosemount™ 245

Toroidal Flow Through Conductivity Sensor
Product Data Sheet
June 2017
LIQ-PDS-245
A noninvasive sanitary sensor for high conductivity applications
Rosemount 245 Toroidal Flow Through Conductivity Sensor

Overview

High Performance and Reliability
Robust measurements - insensitive to process flow rate and
direction.
Avoid accumulation of solids with no part of the sensor
protruding into the sample flow.
Steam sterilizable up to 130 °C.
Meet Flow Through Installation Requirements
Available with 0.5, 1.0, 1.5, and 2 in. Tri Clamp connections.
Liner and O-rings meet FDA and USP Class VI requirements.
Plugging resistant and suitable for liquids containing high
levels of suspended solids.
June 2017
Contents
Simplified wiring with integral junction box.
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
www.Emerson.com/RosemountLiquidAnalysis
June 2017
Rosemount 245 Toroidal Flow Through Conductivity Sensor

Ordering Information

Rosemount 245 sanitary toroidal flow through conductivity sensors come with a NE MA 7D jun cti on box . Requ ired m ati ng fl ang es, clam ps, gas kets , an d Pt -1000 RTD is customer supplied. The extension cable required for wiring from the junction box to a transmitter must be ordered separately.
Table 1. Rosemount 245 Toroidal Flow Through Conductivity Sensor ordering information
Model Sensor type
245 Toroidal Conductivity Sensor
Line Size
01 1/2 in.
02 1 in.
03 1½ in.
04 2 in.
Process Connection
12 TriClamp
Contact Ring Material
SS 316 Stainless Steel
Line Material
PK Virgin PEEK
Process O-ring Material
EP EP O-rings, FDA-Compliant
Typical Model Number: 245-01-12-SS-PK-EP