Rosemount™ 222
Toroidal Flow Through Conductivity Sensor
Product Data Sheet
July 2017
LIQ-PDS-222
A high performance sensor with ease of maintenance in mind
The Rosemount 222 toroidal flow through conductivity sensor measures conductivity in highly conductive liquids up to 2 S/cm
(2,000,000 μS/cm). A noninvasive flow through design allows for in-line installations without any obstruction to sample and makes
these sensors ideal for use with viscous or fibrous liquids.
Rosemount 222 Toroidal Flow Through Conductivity Sensor
Overview
High Performance and Reliability
Robust measurements - insensitive to process flow rate and
direction.
Avoid accumulation of solids with no part of the sensor
protruding into the sample flow.
Corrosion resistant Teflon pipe liner.
Pt-100 RTD included to allow temperature compensated
conductivity measurements.
Operates in process temperatures up to 182 °C (356 °F).
Meet Process Flow Through Requirements
Versatile installation options allows for direct mounting into
1 in. and 2 in. process lines with 150 lb or 300 lb raised face
threaded ANSI B16.5 flanges.
Plugging resistant and suitable for liquids containing high
levels of suspended solids.
July 2017
Contents
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2
Instrument Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
www.Emerson.com/RosemountLiquidAnalysis
July 2017
Rosemount 222 Toroidal Flow Through Conductivity Sensor
Ordering Information
Rosemount 222 Flow Through Toroidal sensors feature Teflon-lined pipe, an external
toroid assembly, two unlined carbon steel outer flanges, a Pt-100 RTD temperature
compensation element, and 20 ft. of integral cable. Optional stainless steel outer
flanges are also available.
Table 1. Rosemount 222 Flow Through Toroidal Conductivity Sensor Ordering Information
Model Sensor type
222 Flow Through Toroidal Conductivity Sensor
(1)
Sizes
01 1 inch, 150 lb flange
02 2 inch, 150 lb flange
05 1 inch, 300 lb flange
06 2 inch, 300 lb flange
Flange option
_ No selection
21 316 stainless steel outer flange
(2)
Cable
54 Standard integral cable
(3)
Typical Model Number: 222-01-_-54
1. Grounding rings are required for proper operation if the outer flanges of the Rosemount 222 sensor are substituted by the customer with non-conductive flanges.
Order SQ 7430 and consult the factory for pricing.
2. Only available with option -01.
3. Cables can be extended using remote junction box PN 23550-00 and extension cable. See Accessories .
www.Emerson.com/RosemountLiquidAnalysis
3