Rosemount Wireless Pressure Gauge with WirelessHART Protocol Quick Start Guide

Quick Start Guide
00825-0100-4045 , Rev CA
Feburary 2021
Rosemount™ Wireless Pressure Gauge
with Wireless HART® Protocol
Quick Start Guide Feburary 2021
NOTICE
This guide provides basic guidelines for Rosemount Wireless Pressure Gauges. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, or intrinsically safe (I.S.) installations. Refer to the Rosemount Wireless Pressure Gauge Reference Manual for more instruction. The manual and this guide are also available electronically.
Shipping considerations
The device is shipped with the battery installed. Each device contains one “D” size primary lithium-thionyl chloride battery. Primary lithium
batteries are regulated in transportation by the U.S. Department of Transportation, and are also covered by IATA (International Air Transport Association), ICAO (International Civil Aviation Organization), and ARD (European Ground Transportation of Dangerous Goods). It is the responsibility of the shipper to ensure compliance with these or any other local requirements. Consult current regulations and requirements before shipping.
WARNING
Explosions could result in death or serious injury.
Installation of device in an explosive environment must be in accordance with appropriate local, national, and international standards, codes, and practices.
Ensure device is installed in accordance with intrinsically safe or non-incendive field practices.
Electrical shock could cause death or serious injury.
Care must be taken during transportation of device to prevent electrostatic charge build-up. Device must be installed to ensure a minimum antenna separation distance of 8 in. (20 cm) from
all persons.
Process leaks could result in death or serious injury.
Handle the transmitter carefully.
Failure to follow these installation guidelines could result in death or serious injury.
Ensure only qualified personnel perform the installation.
WARNING
Physical access
Unauthorized personnel may potentially cause significant damage to and/or misconfiguration of end users’ equipment. This could be intentional or unintentional and needs to be protected against.
Physical security is an important part of any security program and fundamental to protecting your system. Restrict physical access by unauthorized personnel to protect end users’ assets. This is true for all systems used within the facility.
Contents
Required equipment.................................................................................................................... 5
What's in the box?........................................................................................................................ 6
2 Emerson.com/Rosemount
Feburary 2021 Quick Start Guide
Optional: Power/device check...................................................................................................... 8
Optional: Normal range indication option.................................................................................... 9
Installation procedure................................................................................................................ 10
Troubleshooting........................................................................................................................ 14
Product Certifications ................................................................................................................16
Declaration of conformity.......................................................................................................... 21
China RoHS................................................................................................................................ 24
Quick Start Guide 3
Quick Start Guide Feburary 2021
4 Emerson.com/Rosemount
AMS
Feburary 2021 Quick Start Guide

1 Required equipment

Anti-seize paste or PTFE tape (for NPT threaded connection)
Standard tools, e.g. screwdriver,
wrench, pliers
AMS Wireless Configurator version 12.0 or later, or Field Communicator
Quick Start Guide 5
Quick Start Guide Feburary 2021

2 What's in the box?

Wireless Pressure Gauge Quick Start Guide
The following options are also available and will ship with the Rosemount Wireless Pressure Gauge if ordered.
Rosemount 306 Integral Manifold (Model code S5)
6 Emerson.com/Rosemount
B4 Bracket (Model code B4)
Feburary 2021 Quick Start Guide
Rosemount 1199 Seal (Model code S1)
Product Certification (Model Codes
Normal Range Indication (Model code LK)
below) Q4: Calibration Cert QG: Calibration Cert and GOST
Verification Cert QP: Calibration Cert and Tamper Evident
Seal Q8: Material Traceability cert per EN
102043.1 Q15: Cert of Compliance to NACE
MR0175/ISO 15156 for wetted materials Q25: Cert of Compliance to NACE
MR00103 for wetted materials
Quick Start Guide 7
Quick Start Guide Feburary 2021

3 Optional: Power/device check

The device is designed to be installation-ready. To check device battery prior to installation, perform the following:
Procedure
1. Perform Turn on device.
2. Slide the ON/OFF switch to the OFF position until ready for use.
8 Emerson.com/Rosemount
Feburary 2021 Quick Start Guide

4 Optional: Normal range indication option

Procedure
1. Modify each of the stickers to desired size prior to proceeding to step
Step 2.
The stickers are intended to be installed on the dial only and should not be applied on the inside or outside of the housing cover.
2. Remove housing cover.
3. Slide ON/OFF switch to the OFF position and wait for LED to stop flashing.
4. Gently move the needle in the clockwise direction until it is pointing at the Red X.
Note
Use caution as the electronics assembly is connected to the needle.
5. Remove any debris on the dial, so it does not become trapped under the sticker.
6. Peel back the white paper backing of the sticker.
7. Slowly lower the sticker onto the surface of the dial in the desired location and rub it in place firmly. Repeat steps 6 and 7 until desired indication locations are set.
Stickers should be applied in an environment where the ambient
temperature is above 50 °F (10 °C).
Moving the sticker after initial contact is not recommended as
this decreases the amount of adhesive on the back of the sticker.
8. Slide ON/OFF switch to the ON position.
9. Replace housing cover.
Quick Start Guide 9
OR
Quick Start Guide Feburary 2021

5 Installation procedure

Figure 5-1: Seal and protect threads
Figure 5-2: Mount device
Note
Use wrench on flats, not on housing.
5.1

Mounting orientation

The low side pressure port (atmospheric reference) on the process pressure gauge is located in the neck of the device behind the housing. The vent path is between the housing and sensor.
CAUTION
Keep the vent path free of any obstruction, including but not limited to paint, dust, and lubrication by mounting the device so the process can drain away.
10 Emerson.com/Rosemount
A
Feburary 2021 Quick Start Guide
Figure 5-3: Low Side Pressure Port
A. Low side pressure port (atmospheric reference)

5.2 Turn on device

Check to ensure the device and battery are working properly.
Procedure
1. Twist the cover counterclockwise to remove it.
2. Slide the OFF/ON switch to the ON position to initiate the power sequence.
Note
During the power sequence, the dial tests full range of motion and LED flashes amber.
3. Once the power sequence ends, verify the LED flashes green.
Quick Start Guide 11
1 2 3
64 5
8 709
A
B
C
Quick Start Guide Feburary 2021
Note
The LED may display several colors; see Table 6-1in Troubleshooting for device statuses.

5.3 Connect to device

A. Field Communicator B. HART® Modem C. AMS Wireless Configurator

5.4 Field Communicator

Procedure
1. Turn on the Field Communicator.
2. From the Main menu, select the HART® symbol.
5.5
5.6
12 Emerson.com/Rosemount

AMS Wireless Configurator

Procedure
1. Start AMS Wireless Configurator.
2. From the View menu, select Device Connection View.
3. Double click the device under the HART® modem.

Eliminate mounting effects

Devices are factory-calibrated. Once installed, it is recommended to perform this step to eliminate potential error caused by mounting position or static pressure. Instructions for using a Field Communicator are listed below.
Feburary 2021 Quick Start Guide
Note
See the Rosemount Wireless Pressure Gauge Reference Manual for the following:
Using AMS Wireless Configurator
Sensor trim function on absolute gauge
Procedure
1. Vent the device.
2. Connect the Field Communicator.
3. From the HOME screen, enter the HART® Fast Key sequence.
Device dashboard Fast Keys
4. Follow the commands to perform the procedure.

5.7 Activate wireless

Do not activate wireless until Smart Wireless Gateway is installed and functioning properly; toggling off and on reduces battery life.
Note
If Network ID and Join Key is specified at order entry, then the device will automatically search and connect to the wireless network when powered on.
5.8

Join device to network

Procedure
1. Obtain Network ID and Join Key for the wireless network (available in wireless gateway).
2. From the HOME screen, enter the HART® Fast Key sequence.
Device dashboard Fast Keys
3. Follow the commands to perform the procedure.
4. Select Overview>Status.
5. Verify the communication status displays Connected.
2, 1, 1
2, 1, 2
Note
Joining the device to the network could take several minutes.
Quick Start Guide 13
Quick Start Guide Feburary 2021

6 Troubleshooting

This section provides information for basic troubleshooting. See Wireless
Pressure Gauge Reference Manual for advanced troubleshooting.
Device status
The flashing LED indicates device status using the colors descibed.
Table 6-1: Status Descriptions
LED color Device status
Green Functioning properly
Amber Battery is low, battery replacement recommended
Red Battery replacement required OR Device is
No
color
malfunctioning
No power, verify ON/OFF switch is in “on” position

6.1 Pressure measurement

If the mounting effects have not been eliminated after completing Eliminate
mounting effects, perform this alternative procedure for verifying the
pressure value.
Procedure
1. From the HOME screen, eter the HART® Fast Key sequence.
Device dashboard Fast Keys
2. Follow the commands to perform the procedure.
6.2

Wireless connectivity

If the device has not joined to the network after power up, verify the following:
Active Advertising has been enabled on the Smart Wireless Gateway
2, 2, 1, 1, 1
14 Emerson.com/Rosemount
Feburary 2021 Quick Start Guide
Network ID and Join Key in the device match the Network ID and Join Key
of the Gateway
The Network ID and Join Key may be obtained from the Smart Wireless Gateway on the Setup > Network > Settings page on the web interface.
Quick Start Guide 15
Quick Start Guide Feburary 2021

7 Product Certifications

Rev: 4.0
European Directive Information
A copy of the EC Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EC Declaration of Conformity can be found at www.rosemount.com.
Telecommunication compliance
All wireless devices require certification to ensure that they adhere to regulations regarding the use of the RF spectrum. Nearly every country requires this type of product certification. Emerson™ is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.
FCC and IC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions: This devices may not cause harmful interference, this devices must accept any interference received, including interference that may cause undesired operation. This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons.
This device complies with Industry Canada license-exempt RSS-247. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Changes or modification to the equipment not expressly approved by Rosemount Inc. could void the user's authority to operate the equipment.
Cet appareil est conforme à la Partie 15 de la réglementation FCC. Son fonctionnement est soumis aux conditions suivantes: Cet appareil ne doit pas causer d'interférences nuisibles. Cet appareil doit accepter toute interférence reçue, incluant toute interférence pouvant causer un fonctionnement indésirable. Cet appareil doit être installé pour assurer une distance minimum de l'antenne de séparation de 20 cm de toute personne.
Cet appareil est conforme à la norme RSS-247 Industrie Canada exempt de licence. Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute interférence, y compris les interférences pouvant causer un mauvais fonctionnement du dispositif.
Les changements ou les modifications apportés à l'équipement qui n'est pas expressément approuvé par Rosemount Inc pourraient annuler l'autorité de l'utilisateur à utiliser cet équipement.
16 Emerson.com/Rosemount
Feburary 2021 Quick Start Guide
Ordinary Location Certification from CSA
The product has been examined and tested to determine that the design meets the basic electrical, mechanical, and fire protection requirements by CSA, a nationally recognized test laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA).
Installing in North America
The US National Electrical Code (NEC) and the Canadian Electrical Code (CEC) permit the use of Division marked equipment in Zones and Zone marked equipment in Divisions. The markings must be suitable for the area classification, gas, and temperature class. This information is clearly defined in the respective codes.

7.1 USA

I5 U.S.A. Intrinsically Safe (IS)
7.2
Certificate:
Standards:
Markings:
Special Conditions for Safe Use (X):
1. Do not replace battery when explosive atmosphere is present.
2. Use only 00G45-9000-0001 batteries.
3. The surface resistivity of the housing is greater than 1G Ω. To avoid
4. Substitution of components may impair intrinsic safety.
[CSA] 70047656 FM 3600 – 2011, FM 3610 – 2010, UL Standard 50 – Eleventh
Edition, UL 61010-1 – 3rd Edition, ANSI/ISA-60079-0 (12.00.01) – 2013, ANSI/ISA-60079-11 (12.02.01) – 2013, ANSI/IEC 60529 – 2004
IS CL I, DIV 1, GP A, B, C, D T4; Class 1, Zone 0, AEx ia IIC T4 Ga; T4 (-40 °C ≤ Ta ≤ +70 °C) when installed per Rosemount drawing 00G45-1020; Type 4X; IP66/67
electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.

Canada

I6 Canada Intrinsically Safe (IS)
Certificate:
Standards:
[CSA] 70047656 CAN/CSA C22.2 No. 0-10, CAN/CSA C22.2 No. 94-M1991
(R2011), CAN/CSA-60079-0-11, CAN/CSA-60079-11-14, CSA Std C22.2 No. 60529-05, CAN/CSA-C22.2 No. 61010-1-12
Quick Start Guide 17
Quick Start Guide Feburary 2021
Markings:
Special Conditions for Safe Use (X):
1. Do not replace battery when explosive atmosphere is present.
2. Use only 00G45-9000-0001 batteries. Utiliser uniquement des
3. The surface resistivity of the housing is greater than 1G Ω. To avoid
4. Substitution of components may impair intrinsic safety.

7.3 Europe

I1 ATEX Intrinsic Safety
Intrinsically Safe for Class I, Division 1, Groups A, B, C, D T4; Ex ia IIC T4 Ga T4 (-40 °C ≤ Ta ≤ +70 °C) when installed per Rosemount drawing 00G45-1020; Type 4X; IP66/67
Ne pas remplacer les accumulateurs si une atmosphère explosive peut être présente.
accumulateurs 00G45-9000-0001.
electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
La résistivité de surface du boÎtier est supérieure à un gigaohm. Pour éviter l’accumulation de charge électrostatique, ne pas frotter ou nettoyer avec des produits solvants ou un chiffon sec.
La substitution de composants peut compromettre la sécurité intrinsèque.
Certificate:
Standards:
Markings:
Special Conditions for Safe Use (X):
1. The plastic enclosure may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth.
2. The measured capacitance between the equipment enclosure and metallic inline sensor module is 4.7 . This must be considered only when the WPG is integrated into a system where the process connection is not grounded.
3. Do not change the battery when an explosive atmosphere is present.
4. Only replace battery with Rosemount Part No. 00G45-9000-0001.
18 Emerson.com/Rosemount
Baseefa16ATEX0005X EN 60079-0: 2012 + A11: 2013, EN 60079-11: 2012
II 1 G Ex ia IIC T4 Ga, T4 (-40 °C ≤ Ta ≤ +70 °C) IP66/67
Feburary 2021 Quick Start Guide

7.4 International

I7 IECEx Intrinsic Safety
Certificate:
Standards:
Markings:
Special Conditions for Safe Use (X):
1. The plastic may constitute a potential electrostatic ignition risk and
2. The measured capacitance between the equipment enclosure and
3. Do not change the battery when an explosive atmosphere is present.
4. Only replace battery with Rosemount Part No. 00G45-9000-0001.

7.5 Brazil

I2 INMETRO Intrinsic Safety
Certificate:
Standards:
Markings:
IECEx BAS 16.0012X IEC 60079-0: 2011, IEC 60079-11: 2011 Ex ia IIC T4 Ga, T4 (-40 °C ≤ Ta ≤ +70 °C) IP66/67
must not be rubbed or cleaned with a dry cloth.
metallic inline sensor module is 4.7pF. This must be considered only when the WPG is integrated into a system where the process connection is not grounded.
UL-BR 16.0826X ABNT NBR IEC 60079-0:2008 + Errata 1:2011, ABNT NBR IEC
60079-11:2009 Ex ia IIC T4 Ga, T4 (-40 °C ≤ Ta ≤ +70 °C)
Special Condition for Safe Use (X):
See certificate for special condition.
7.6
Quick Start Guide 19

Japan

I4 CML Intrinsic Safety
Certificate:
Markings:
Special Condition for Safe Use (X):
See certificate for special condition.
CML18JPN2350X Ex ia IIC T4 Ga, T4 (-40 °C ≤ Ta ≤ +70 °C)
Quick Start Guide Feburary 2021

7.7 EAC - Belarus, Kazakhstan, Russia

IM Technical Regulation Customs Union (EAC) Intrinsic Safety
Certificate:
Markings:
Special Condition for Safe Use (X):
See certificate for special condition.

7.8 Korea

IF KTL Intrinsic Safety
Certificate:
Markings:
Special Condition for Safe Use (X):
See certificate for special condition
TC RU C-US.AA87.B.00372 0Ex ia IIC T4 Ga X, T4 (-40 °C ≤ Ta ≤ +70 °C) IP66/67;
16-KA4BO-0540X Ex ia IIC T4 Ga, T4 (-40 °C ≤ Ta ≤ +70 °C)
20 Emerson.com/Rosemount
Feburary 2021 Quick Start Guide

8 Declaration of conformity

Quick Start Guide 21
Quick Start Guide Feburary 2021
22 Emerson.com/Rosemount
Feburary 2021 Quick Start Guide
Quick Start Guide 23
Quick Start Guide Feburary 2021

9 China RoHS

24 Emerson.com/Rosemount
Feburary 2021 Quick Start Guide
Quick Start Guide 25
Quick Start Guide Feburary 2021
26 Emerson.com/Rosemount
Feburary 2021 Quick Start Guide
Quick Start Guide 27
* 00825-0100-4045 *
00825-0100-4045 , Rev. CA
Quick Start Guide
Feburary 2021
For more information:
©
2021 Emerson. All rights reserved.
Emerson Terms and Conditions of Sale are available upon request. The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount is a mark of one of the Emerson family of companies. All other marks are the property of their respective owners.
www.emerson.com
Loading...