Pay special attention to the following signal words, safety alert symbols, and statements:
Safety alert symbol
This is a safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that
follow this symbol to avoid possible injury or death.
DANGER
Danger indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Warning indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Caution indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Notice is used to address safety messages or practices not related to personal injury.
Important
Important is a statement the user needs to know and consider.
Tip
Tip provides information or suggestions for improved efficiency or best results.
Note
Note is “general by-the-way” content not essential to the main flow of information.
Mark III Wiring I/O and switch settings........................................................................................40
Summary table of communications/output settings.................................................................. 48
3810 Communication and Output settings................................................................................ 52
3810 Series engineering drawings..............................................................................................66
2 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
1Plan
1.1Introduction
1.1.1General
Welcome to the Rosemount 3810 Series Ultrasonic Instruction Manual.
This manual has been designed to provide you with a step-by-step set of
instructions for a Rosemount Liquid Ultrasonic meter with 3800 Series
electronics to the new 3810 Series electronics.
NOTICE
Please read the “Before You Begin” section to make sure you have all the
components necessary to perform the before taking the meter out of
service.
1.2Before you begin
This section shows all of the parts and tools required to perform the
upgrade. Ensure that all of these items are available before taking the 3800
Series meter out of service.
1.2.1Required parts
Ensure that you have received the to upgrade your meter.
Upgrade kit instructions3
Upgrade kit instructionsJune 2022
1.2.2Tools required
Figure 1-1: Required Tools
A. ⅛-in. flat-blade screw driver
B. ¼-in. flat-blade screw driver
C. 3/8-in. drive ratchet wrench
D. 3/8-in. drive - extension - at least 3.5-in. long
E. 3/8-in. drive - 7/16-in. socket
F. Allen wrench - size 6 mm
G. Crescent wrench for cable glands and electrical conduit
MeterLink™ is required to communicate with the meter electronics, access
information and collect the configuration in the meter and then convert and
download the configuration into the new 3810 Series electronics. Always
use the latest version of MeterLink™. Upgrades to the latest version are
available at: Emerson.com/Rosemount
4 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
1.3Before removing the 3800 Series Electronics
1.3.1Procedure before removing the 3800 Series Electronics
Procedure
1. Before removing power from the meter being software to connect to
the meter.
2. Use the Edit/Compare Configuration screen in MeterLink
to read the configuration from the meter and save it to a file on your
computer. An example for a file name might be “Meter Name, 3800
Series Final Config, 3-4-2013 10-15-02 AM.cfg”. MeterLink will be
used later in this procedure (see Configure the 3810 Series
Electronics) to convert the configuration and download it to the
3810 Series electronics.
™
CAUTION
Loss of set-up data
The current meter configuration file must be saved before beginning
the 3810 Series electronics .
Failure to save the current configuration file can result in the loss of
important set-up data.
3 through 8 provide more detailed instructions on obtaining the
required information with respect to the communications set-up of
the 3800 Series electronics, however, if these settings are already
known, these steps can be skipped. Step 8 is for Frequency and
Diagnostic outputs. For reference, the known values should be
entered in the Summary table of communications/output settings in
Appendix B. This information will be required in the setup of the 3810
Series electronics. For any setting which is not known, the applicable
step(s) for obtaining that information can be used.
3. Use the File|Meter Directory menu path, then select the
<meter name> you want to .
a) Click the Direct button on the lower left corner of the Meter
Directory dialog box.
b) The Direct Connection Properties For dialog appears.
c) Obtain the Modbus ID (same as Comms Address).
Upgrade kit instructions5
Upgrade kit instructionsJune 2022
Figure 1-2: Accessing Modbus ID for Ports A and B
4. Based on the information contained in the connection properties
window, enter the values for the following parameters in the
Summary table of communications/output settings in Appendix B:
Port A and B: Modbus ID = _____(enter Comms Address).
5. Exit MeterLink and disconnect your PC from the meter electronics.
The remaining information required before doing the , is based on
the wiring terminations and the settings of various switches on the
boards that comprise the electronics.
6. Power down the electronics.
CAUTION
Equipment damage
Remove power from the meter electronics.
Failure to remove power from the meter electronics may result in
damage to the equipment.
7. Remove the end caps from the upper electronics housing of the
meter to access the electronic circuit boards. See Figure 1-4 for
board layout of the 3800 Series stacks. See Figure 3-4 for the 3810
Series electronics for board layout.
6 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure 1-3: Remove End Caps from the Upper Electronics
Enclosure
Figure 1-4: 3800 Series Electronics Assembly board layout
8. Remove the 3800 Series electronics CPU board, the HART Option
Board, and the Field Termination Board from the enclosure. Fill out
the Summary table of communications/output settings in Appendix
B based on the Field Connection Board wire terminations and/or
switch settings of the CPU board and Option Board, if installed. This
information will be used to configure the new 3810 Series electronics
later in this procedure.
Upgrade kit instructions7
Upgrade kit instructionsJune 2022
Figure 1-5: 3800 Series CPU Board Showing Switch Settings
Figure 1-6: 3800 Series CPU Board with I.S. Barrier Board PiggyBacked on CPU Board
8 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
1.4Removing 3800 Series Electronics
1.4.1Procedure to remove the 3800 Series Electronics
Procedure
1. Having obtained all the information related to the set-up of the 3800
Series electronics configuration and communications, all the
components related to the electronics can now be physically
removed from the meter. Unscrew all wiring from the Field
Termination Board. It may be helpful to label the wires to make it
easier to connect the 3810 Series electronics.
2. Remove any conduit and wiring attached to all six conduit ports.
3. Remove any ground wire attached to the ground lug on the outside
of the upper electronics housing. At this point there should be no
wires connected to the upper electronics housing.
Figure 1-7: Ground Wire Removed
4. Use the 6mm Allen wrench (supplied with kit) to remove the two
bolts holding the base enclosure.
Upgrade kit instructions9
Upgrade kit instructionsJune 2022
Figure 1-8: Remove Bolts from Base Enclosure Cover
5. Remove the upper electronics housing from the base enclosure.
a) Remove the Acquisition cable, which comes down from the
upper electronics to the Acquisition module in the base
enclosure.
NOTICE
Figure 1-9 shows the Acquisition module for the 3400 Series
electronics.
b) Loosen the two screws on the ends of the Acquisition cable
connector, and disconnect it from the Acquisition module.
c) Set the upper electronics housing aside once the housing is
removed.
10 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure 1-9: Remove the Acquisition Cable
6. Remove all the screws that hold the transducer wires in the terminal
blocks that attach the transducers to the Acquisition module.
a) Remove the screws from the ends of the two connectors.
b) Disconnect the connectors and remove each of the
transducer wires from the connector.
7. Loosen the cable glands on the base enclosure and pull all of the
transducer cables out of the base enclosure.
8. Unscrew the three screws holding the Acquisition module in the base
enclosure and remove the Acquisition module.
The four mounting bolts holding the enclosure cover to the meter
body are sealed with an RTV silicone adhesive/sealant.
9. Remove the RTV with a flat blade screwdriver or utility knife around
the perimeter of the recessed opening and the RTV eases the
removal of the sealant.
a) Use the 7/16-in. socket wrench to remove the four mounting
bolts.
Upgrade kit instructions11
Upgrade kit instructionsJune 2022
Figure 1-10: Remove Old RTV
10. Remove the base enclosure from the meter body.
11. If RTV silicone adhesive/sealant was used to seal the base enclosure
to the meter body, remove the adhesive/sealant so the 3810 base
enclosure will have a clean mounting surface.
The 3800 Series electronics should be completely removed from the
meter body at this time.
12 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
2Install
2.1Installing the 3810 Series Electronics
2.1.1Procedure to install the 3810 Series Electronics
Procedure
1. Remove the 3810 Upgrade components from the packaging.
a) Use the 6 mm Allen wrench to remove the two screws from
the base enclosure cover.
2. Lift the upper electronics housing from the base enclosure. The
acquisition cable connector from the upper electronics is attached to
the acquisition module with two screws. The cable is also secured by
a cable clamp to a mounting bolt.
a) Remove the screw securing the cable clamp and then loosen
the two screws on the acquisition cable connector and
disconnect the acquisition cable connector from the
acquisition module.
Figure 2-1: Remove Acquisition Cable and Module
3. Unscrew the remaining two mounting screws from the acquisition
module in the base enclosure and remove the acquisition board.
4. Place an insulating gasket on the meter body where the electronics
will be mounted (see gasket in Figure 3-4).
5. Place the base enclosure on top of the meter body on top of the
insulating gasket. Note that the transducer port openings on the
base enclosure are labeled with transducer locations (i.e., A1, A2, B1,
B2, C1, C2, D1, D2).
a) Orient the base so that the A1 transducer port is closest to the
A1 transducer location on the meter body. The meter body
has the transducer location labels embossed in the body next
to each transducer boss. The ports on the base enclosure
Upgrade kit instructions13
Upgrade kit instructionsJune 2022
must be oriented outward (towards the sides of the meter
body, perpendicular to meter axis).
Figure 2-2: Base Enclosure Orientation
6. Use the four
¼-in. bolts with stainless steel washers and nylon
shoulder washers to secure the base enclosure to the meter body.
a) Use a nut driver to tighten the bolts to a torque of 55 to 65
inch-lbs.
Figure 2-3: Insert ¼-in. Bolts
7. Fill up the base enclosure wells with RTV adhesive/sealant around
and over the four ¼-in. bolts.
This will ensure a water-tight seal. Any excess sealant can be
removed by using a scraper to leave the sealant flush with the top of
the well. Excess sealant will adhere to the acquisition board when it is
installed, and make future removal of the board difficult.
14 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure 2-4: Apply RTV Sealant Around Bolts
8. Insert the Acquisition board in the base enclosure and secure it with
the two screws as shown for now.
Figure 2-5: Acquisition Module Attachment Screws
Upgrade kit instructions15
Upgrade kit instructionsJune 2022
Figure 2-6: Acquisition Module Wiring
9. Route the transducer cables through the cable glands with the
correct label number (i.e. A1) which matches the label on the
transducer cable.
Figure 2-7: Base Enclosure Cable Glands Installation
10. Judge the proper length and cut off the excess.
11. Strip the outer insulation, outer shield, and inner insulation using a
utility knife. Verify that insulation of individual wires was not cut
while removing outer layers. Strip each wire 0.28-in.
16 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure 2-8: Transducer Cable Cut Instructions
12. Insert tubing over wires, inner insulation and under shield
approximately 1.5-in. of shield should overlap.
13. Insert and secure transducer cables through cable glands verify Line
Mark is as referenced in Figure 2-7.
Figure 2-9: Line Mark
14. Using a torque screwdriver set to 78±7 oz.-in. secure the wires to the
terminal plugs of the Acquisition Module.
15. Verify the cable lengths are still an appropriate length and if
necessary, cut the transducer cables to the correct length with
allowance for the wiring terminations and connector placement.
16. Ensure that the contacts clamp on the bare wires and not on the wire
insulation when the wires are being terminated on the connector.
a) Leave the connector plugged into the Acquisition board while
terminating the individual wires.
b) Tighten the connector screws on the either end of the
connector after terminating all the wires on the applicable
connector.
c) Repeat this procedure for the transducer cables on the other
side of the meter.
Upgrade kit instructions17
Upgrade kit instructionsJune 2022
Figure 2-10: Install Cable and Secure Wires
17. Use the cable ties to dress the transducer cables. They should be
dressed in groups of two: A1 and C1, D1 and B1, A2 and C2, D2 and
B2. Install one cable tie at three inches from the base enclosure and
another about the point where the cables start to bend and separate
out to their respective port.
18 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure 2-11: Re-oriented and Secured Transducer Cables
18. Reconnect the acquisition cable connector to the acquisition module
and secure the cable connector by tightening the two screws.
19. Install the cable clamp on the Acquisition cable with the screw, lock
washer, flat washer to secure the cable to the final mounting hole of
the Acquisition module..
Upgrade kit instructions19
Upgrade kit instructionsJune 2022
Figure 2-12: Installing the Acquisition Cable and Module
A. Acquisition cable connector
B. Acquisition cable
C. Cable clamp and screw
20. Wrap the excess cable around the Acquisition Module and place the
electronics housing into position on the base enclosure.
21. Ensure the O-ring on the base of the upper enclosure is properly
seated. Position the upper enclosure housing so that it is in the
desired orientation for reattaching the electrical conduit.
22. Install the 3810 meter upper enclosure on the base enclosure once
the transducers are wired correctly.
23. Install the two screws with the 6 mm Allen wrench to secure the
upper enclosure to the base enclosure.
20 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure 2-13: Bolt the Upper Enclosure to Base Enclosure
24. Remove the end cap next to the conduit entries from the upper
enclosure. Figure 2-14 shows the layout of the 3810 electronics.
Upgrade kit instructions21
Upgrade kit instructionsJune 2022
Figure 2-14: 3810 Series Electronics Layout
A. End cap
B. CPU module
C. Optional I/O module
D. 3810 Series Transmitter electronics enclosure
E. I. S. Barrier module
F. Power supply
G. Backplane
H. Optional local display module
I. End cap
J. Acquisition module
K. Base electronics enclosure
22 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
L. Cable glands
M. U.L. warning tag - Base enclosure
N. M20 plug
O. Gasket
The following table shows the default communications and output
settings for the 3810 electronics and configuration.
Table 2-1: 3810 Series Default Communications and Output
Settings
Communication
/output type
Serial port AModbus ID = 32Baud rate =
Frequency/
digital output 1
Frequency/
digital output 2
Frequency/
digital output 3
If the settings above are not consistent with those used in your
meter, then these parameters can be changed using MeterLink
Default settingDefault settingNote
Port B and port C
are available if
optional RS-232
and RS- 485 I/O
modules are
installed
Frequency
output 1A is
configured for
uncorrected
forward flow
Frequency
output 2A is
configured for
uncorrected
forward flow
Digital output 1A
is configured for
validity status
Configured to
output frequency
1A
Configured to
output frequency
2A
Configured to
output digital
output 1A
19200
Drive mode =
open collector
Drive mode =
open collector
Drive mode =
open collector
™
software to reconfigure the communication ports and output ports
later in this procedure. 3810 Communication and Output settings of
this document contains additional details with respect to the wiring
related to the communications and discrete output signals.
Notice
MeterLink™ cannot communicate with 3810 meters over a halfduplex serial connection. As a result, for MeterLink to communicate
via a serial connection, that port on the 3810 electronics must be set
for RS-232-Full Duplex, or RS-485-Full Duplex (requires 4 conductor
cables).
Upgrade kit instructions23
Upgrade kit instructionsJune 2022
25. Check the CPU module switches on the to ensure they are set
properly.
Figure 2-15: CPU Switch Settings
A. WRITE PROT. switch
B. DHCP switch
C. Port A (override)
The DHCP switch enables or disables the DHCP server for Ethernet
communication. The WRITE PROT. switch enables or disables “write
protection” of the meter configuration.
Set the DHCP switch to the ON position to enable Ethernet
communication via the DHCP server. Set the WRITE PROT. switch to
the OFF position to allow configuration parameters to be written to
the meter. Only enable the DHCP server if the meter is not connected
to a network that may have a DHCP server already running. The
DHCP server is designed for use when a PC connects directly to the
meter and requires the meter to assign the PC an IP address.
26. Wire all of the electrical connections.
24 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure 2-16: Install Wiring Terminal Block Connectors to the CPU
Module
All of the terminations in the 3810 Series electronics are removable
terminal blocks. Removing the terminal blocks from the modules
before terminating wires to them makes wiring easier. 3810
Communication and Output settings of this document also includes
wiring tables and illustrations for each of the connectors in the
electronics. Refer to the System Wiring Drawing in Appendix D.
27. Install a ground wire to the ground lug on the side of the upper
enclosure.
28. Attach flex conduit to the conduit ports on the transmitter
electronics enclosure.
Before applying power to the meter, ensure the atmosphere is
proven safe using an intrinsically safe gas detector.
WARNING
EXPLOSION HAZARD
Do not apply power to the meter with the end caps removed unless
you are in a non-hazardous or explosive-free environment.
Failure to comply could result in death, serious injury and possible
equipment damage.
29. Apply the sealing compound to the conduit seal fittings and allow to
set in accordance with manufacturer specifications.
30. Apply electrical power to the system and verify the field connections
are working correctly.
31. Do not install end caps until you configure the meter.
This completes the installation of the hardware associated with the
3810 Series Electronics meter upgrade procedure.
26 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
3Operate
3.1Configure the 3810 Series Electronics
1. Check all settings and wiring carefully.
2. Set up the Meter Directory, and start initial communication with the
3810 Series electronics.
The basic instructions for setting up the directory and initializing
communications are contained in the following text. Refer to the 3810
Series Liquid Ultrasonic Flow Meter Installation Manual for more detailed
instructions. Use MeterLink v1.10 or later to make a connection to the
meter.
3.1.1Initial communication connection using Ethernet
Ethernet initial connection material checklist
The following materials and information are required:
• 3810 Ethernet adapter cable
• Personal computer (PC) configured as follows:
— MeterLink software installed (version 1.10 or later)
— Ethernet LAN adapter
— Configured to automatically obtain IP address (via DHCP)
• Desired 3800 Series 3810 meter(s) communication configuration
parameters:
— IP address
— Serial communication parameters such as baud rate and Modbus ID
(if desired)
Ethernet initial connection steps
Procedure
1. Power up the 3810 Series meter and wait two minutes for the meter
to startup.
2. Ensure that the Ethernet DHCP server is enabled on the 3810 CPU
Module by setting DHCP switch to the ON position.
3. Plug the Ethernet adapter cable into the meter CPU Module and
connect the RJ45 end into the PC Ethernet connector.
4. Verify the Ethernet connection status by the 3810 CPU Module LINK
LED which should be solid green.
5. Start MeterLink™ on the PC. The Connect to Meter dialog displays.
Upgrade kit instructions27
Upgrade kit instructionsJune 2022
a) Click the Edit Meter Directory button.
b) Click the Add button (below the Meter Directory file
operations field). MeterLink inserts the New Meter record in
the last field in the Meter Directory table.
6. Create a new meter directory record with the following parameters:
a) Enter a name for the meter.
b) Select Meter Type as Gas or Liquid as appropriate.
c) Check the Ethernet box and uncheck the Direct and Modem
boxes.
d) Set the Ethernet IP address to 192.168.135.100.
e) Close the Meter Directory window.
7. Use the Meter|Connect menu path and click the Ethernet
connection for the meter record established in the previous step.
MeterLink™ will now connect to the meter using the user-specified
Ethernet settings.
3.1.2Initial communication connection using RS-232 Serial
Communications settings and Field Setup Wizard
RS-232 Serial initial connection material checklist
The following materials and information are required:
• Ultrasonic serial cable.
• Personal computer (PC) with MeterLink™ software version 1.10 (or later)
• Desired 3800 Series3810 meter(s) communication configuration
parameters:
— IP address (if desired)
— Serial communication parameters such as baud rate and Modbus ID
RS-232 Serial initial connection steps
Procedure
1. Power up the 3810 meter and PC.
2. Plug the DB-9 end of the cable directly into the PC running
MeterLink. The three wires on the other end of the cable connect to
RX, TX, and COM terminals on the CPU Module. The Digital Out wire
goes to RX, the Digital In wire goes to TX, and the COMMON wire
goes to COM.
28 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure 3-1: CPU RS-232 serial connection
Table 3-1: CPU RS-232/RS-485 wire colors
CPUWire colors
R XRed
T XWhite
C O MBlack
3. Start MeterLink™ on the PC and create a new Meter Directory record
with the following parameters:
Upgrade kit instructions29
Upgrade kit instructionsJune 2022
a) Enter a name.
b) Select Meter Type as Gas or Liquid as appropriate.
c) Check the Direct box and uncheck the Modem and Ethernet
boxes.
d) Set the Direct connection properties for Baud Rate of 19200
and Comms Address (Modbus ID) of 32.
4. Use the Meter|Connect menu path and click Direct connection for
the meter record established above. MeterLink™ will now connect to
the meter using the user-specified serial communication settings.
30 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Follow the instructions in LINK HERE to write the converted
configuration file to the meter.
Meter Communications Settings
Procedure
1. Use the Meter|Communications Settings menu path to
access the Communications dialog.
This dialog displays the communications parameters for the 3810
Series electronics and is used to adjust the Baud Rate and Comms
Address (i.e. Modbus ID) for the serial ports.
Figure 3-2: Communications Settings dialog
2. Use the
Driver selection pull-down menu if communication settings
require RS-485
Upgrade kit instructions31
Upgrade kit instructionsJune 2022
Figure 3-3: Change driver selection for RS-485 half duplex or full
duplex communication
3.1.3Write the converted configuration file to the meter
Important
If the Mark III electronics contained keys, the user needs to ensure the same
keys are enabled in the 3410 electronics prior to writing the convereted
configuration. Otherwise, some configuration points may not be able to be
written.
Writing the converted configuration file to the meter
Procedure
1. With communication to the meter established, use the Tools|Edit/
Compare Configuration menu path to access the Edit/Compare
Configuration dialog.
32 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
2. Click Open and the Open Configuration File dialog
displays.
Figure 3-4: Edit/Compare Configuration Dialog
a) Select the final 3800 Series configuration file created in Step 2
of Procedure before removing the 3800 Series Electronics of
this document (i.e., “Meter Name, 3800 Series Final Config,
3-4-2005 10-15-02 AM.cfg”).
b) Click Open. The file opens and you returned to the Edit/
Compare Configuration dialog.
Figure 3-5: Open Configuration File Dialog
c) Click Convert (see Figure 3-6). MeterLink™ reads the 3810
configuration from the meter and modifies it with the 3800
configuration.
Upgrade kit instructions33
Upgrade kit instructionsJune 2022
Figure 3-6: Edit/Compare Configuration Dialog with
Active Convert Button
If the meter supports HART, check the 2nd variable
parameter setting using the Field Setup Wizard|
Current Outputs dialog. A reminder dialog prompts you
to set this parameter.
Figure 3-7: HART Parameter Settings
For Liquid ultrasonic meters, the HART Secondary Variable
option is:
• Uncorrected flow rate
All data points shown in yellow have been modified from the
3800 configuration.
34 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure 3-8: Converted Configuration with Highlighted
Changes
d) Click Write Checked to write the converted configuration to
the meter (see Figure 3-8). If an error occurs, MeterLink™ will
display a message indicating the nature of the problem.
Manually edit the parameter(s) with errors to successfully
complete the download.
e) Click Write Checked again after modifying the parameter(s).
Repeat this until the write occurs with no errors.
f) Save the 3800 Series electronics configuration file to your PC.
g) With the converted configuration still displayed, from the
Edit/Compare Configuration dialog, click the Meter radio
button, located next to the Compare button (see Figure 3-8).
h) Compare the file to verify that this saved configuration
matches the meter configuration. If an error occurs, go back
to the beginning of the Step 2 and try again until no errors are
reported.
3. Use the Meter|Monitor menu path to display the Monitor
window and verify that the meter is operating correctly.
Upgrade kit instructions35
Upgrade kit instructionsJune 2022
Figure 3-9: Meter Monitor Dialog
3.1.4Configure the meter using the Field Setup Wizard
Configuring the meter using the Field Setup Wizard
Procedure
1. Use the Meter|Field Setup Wizard menu path to access the
Field Setup Wizard Startup dialog.
a) Verify that all settings (options) are correct (e.g.,
temperature, pressure, meter connections and meter
outputs).
b) In the Meter name field insert a name for the meter (this
name displays on MeterLink™ main window and the
Maintenance logs and Reports files).
c) Ensure the 3810 Series Electronics digital outputs are
configured appropriately. The .
36 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure 3-10: Field Setup Wizard Startup Dialog
2. Setup the Frequency and Digital Output Sources parameters from
the Field Setup Wizard Frequency/Digital Outputs Sources Page.
Figure 3-11: Field Setup Wizard Frequency and Digital Output
Sources Page
Upgrade kit instructions37
Upgrade kit instructionsJune 2022
The meter has user-configurable selections for either a frequency
output or digital status (FODO). Use the pull-down menus to edit
these parameters.
(3) Frequency/Digital Outputs:
• FODO1 (four possible output configurations)
• FODO2(eight possible output configurations)
• FODO3(eight possible output configurations)
Frequency or Digital Outputs (FODO 1) source selections:
• FO1A, DO1A, FO1B, DO1B
Frequency or Digital Outputs (FODO 2) source selections:
• FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Frequency or Digital Outputs (FODO 3) source selections:
• FO1A, DO1A, FO1B, DO1B, FO2A, DO2A, FO2B, DO2B
Mode options:
• Open Collector (requires external excitation supply voltage and
pull-up resistor)
• TTL (internally powered by the meter 0-5 VDC signal)
Channel B Phase options:
• Lag forward, Lead reverse (Phase B lags Phase A while reporting
forward flow, leads Phase A while reporting reverse flow)
• Lead forward, Lag reverse (Phase B leads Phase A while reporting
forward flow, lags Phase A while reporting reverse flow)
Phase A and Phase B output (based on flow direction):
• Reverse flow - output only reports flow in the reverse direction.
For frequency outputs, Phase B of the output is 90 degrees out of
phase with Phase A.
• Forward flow - output only reports flow in the forward direction.
For frequency outputs, Phase B of the output is 90 degrees out of
phase with Phase A.
• Absolute - output reports flow in both directions. For frequency
outputs, Phase B of the output is 90 degrees out of phase with
Phase A.
• Bidirectional - output reports flow on Phase A only in the forward
direction and on Phase B only in the reverse direction.
Maximum frequency for the frequency outputs:
38 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
• 1000 Hz
• 5000Hz
3. If changes were made in the Field Setup Wizard, choose to save the
configuration when MeterLink™ prompts you after the changes are
written to the meter. Click Finish in the Field Setup Wizard dialog to
write any changes to the meter.
4. You have successfully completed upgrading your3800 Series
electronics to 3810 Series electronics.
5. Save your configuration file for the meter's parameters you just set as
the “As Left Settings”.
Upgrade kit instructions39
Upgrade kit instructionsJune 2022
AMark III Wiring I/O and switch settings
Use the wiring I/O and switch settings in this appendix to configure the 3810
Series electronics parameters.
Figure A-1: Mark III Field Connection Board Switches and Connectors
40 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure A-2: Mark III CPU Boards Switches
Note
The switch positions shown in the sketches of the switch banks are the
factory default positions.
A.1
Upgrade kit instructions41
3800 Series RS-232 Full Duplex
Figure A-3: Port A Settings
Upgrade kit instructionsJune 2022
Figure A-4: Port B Settings
A.23800 Series RS-485 Half Duplex
Figure A-5: Port A Settings (Factory Default Switch Settings for Port A)
Figure A-6: Port B Settings
42 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
A.33800 Series Discrete output switch settings
Figure A-7: Group 1 Frequency and Digital Outputs
Figure A-8: Group 2 Frequency and Digital Outputs
Upgrade kit instructions43
Upgrade kit instructionsJune 2022
Figure A-9: Series 100 Option Board (If Installed)
A.43800 Series RS-232 Full Duplex
Figure A-10: Port C Settings
A.53800 Series RS-485 Half Duplex
Figure A-11: Port C Settings
44 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
A.63800 Series Series 100 option board (if installed)
Figure A-12: Analog Output 1
Figure A-13: Analog Input 1 (Temperature)
Figure A-14: Analog Input 2 (Pressure)
Upgrade kit instructions45
Upgrade kit instructionsJune 2022
Figure A-15: Series 100 Plus HART Option Board (If Installed)
A.73800 Series RS-232 Full Duplex
Figure A-16: Port C Settings
A.83800 Series RS-485 Half Duplex
Figure A-17: Port C Settings
46 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
A.93800 Series Series 100 plus HART option board (if
installed)
Figure A-18: Analog Output 1
Figure A-19: Analog Output 2 (HART capable)
Figure A-20: Analog Input 1 (Temperature)
Figure A-21: Analog Input 2 (Pressure)
Upgrade kit instructions47
Upgrade kit instructionsJune 2022
BSummary table of communications/output
settings
Based on switch position on the 3800 CPU board and Option board if
installed, indicate the appropriate configuration for each communication/
output parameters on the 3800 electronics. Use these parameters to
configure the 3810 Series electronics.
(Check electronics switch settings and circle appropriate box for
each output)
Not
used (if
J5-1 not
used)
Not
used (if
J5-6 not
used)
Not
used (if
J5-5 not
used)
Not
used (if
J12-1
not
used)
Not
used (if
J12-3
not
used)
Not
used (if
J11 not
used)
Not
used (if
J10 not
used)
TTL (if S8-4 is set
to TTL)
TTL (if S9-3 is set
to TTL)
TTL (If S9-4 is set
to TTL)
Source (if S12 is
set to SRC)
Source (if S13 is
set to SRC)
Source (if S14 is
set to SRC)
Source (if S15 is
set to SRC)
Open Collector (if
S8-4 is set to OC)
Open Collector (if
S9-3 is set to OC)
Open Collector (if
S9-4 is set to OC)
Sink (if S12 is set to
SINK)
Sink (if S13 is set to
SINK)
Sink (if S14 is set to
SINK)
Sink (if S15 is set to
SINK)
Enter the results of the 3800 Summary Table of Communications/output
settings in the table below as a quick reference to setup the 3810 Series
meter configuration parameters.
(1) Port B and C are not available for 3810 Series electronics in default
(1)
configuration. Port B is available for 3810 Series electronics with Optional I/O
RS-232, RS-485 or Expansion I/O Modules installed.
output settings
50 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Upgrade kit instructions51
Upgrade kit instructionsJune 2022
C3810 Communication and Output settings
C.13810 Wiring and I/O
Refer to the 3810 Series Ultrasonic Liquid Flow Meter Installation Manual for
more wiring details.
Figure C-1: CPU Module Labeling and LED Indicators
Table C-1: CPU Module Labeling and LED Functions
CPU Module label or LEDFunctionSwitch position indicator
WRITE PROT.Write-protect mode - with
switch in the ON position
(default setting) protects
configuration and
firmware overwrites. To
write configuration
changes or download
firmware to the meter
change the switch to the
OFF position
52 3810 Series Electronics Upgrade kit instructions
or LED
Switch position
• ON - (default setting)
enables writeprotection of the
configuration and
firmware
• OFF - enables writing
configuration changes
or downloading
firmware
June 2022Upgrade kit instructions
Table C-1: CPU Module Labeling and LED Functions (continued)
DHCPDynamic Host Protocol
Server - enables you to
communicate with a
Rosemount™ Ultrasonic
meter that is not
connected to a network.
When the CPU Module
switch is in the ON
position, the meter is
enabled to act as a DHCP
server for a single DHCP
client connected to the
Ethernet port using a
crossover cable. This
should be used for peer to
peer connections only.
When the connection is
made, select to use the
Meter Name in the meter
instead of the Meter
Directory Name in order to
keep all log files and
configurations separate
from each meter.
PORT APORT A override - RS-232
serves as an override
during meter
commissioning to
establish communications
and in the event the user
cannot communicate with
the meter due to an
inadvertent
communication
configuration change. The
override period is for two
minutes. Supports:
• auto-detected ASCII
(Start bit 1, Data Bit 7,
Parity Odd/Even, Stop
Bit 1)
• RTU (Start Bit 1, Data
Bit 8, Parity none,
Stop Bit 1).
• Modbus protocols
RS-232 Baud
rate=19,200 Modbus
ID=32
Switch position
• ON - the meter is
enabled to act as a
DHCP server for a
single DHCP client
• OFF - disables the
DHCP server
Switch position
• ON - enables RS-232
PORT A override
• OFF - (default setting)
disables RS-232 PORT
A override
Upgrade kit instructions53
Upgrade kit instructionsJune 2022
Table C-1: CPU Module Labeling and LED Functions (continued)
MEASSystem color indicates
metrology mode
Acquisition mode
Measurement mode
PWR3.3V Power IndicatorSolid Green
LED 4Not used
LED 5Not used
RXRX signal (Port A for RS485
or RS232)
communication) receiving
data
TXTX signal (Port A for
RS485; 2-wire or 4-wire) or
RS232 communication)
transmitting data
LINKETH1Link user Ethernet
connection
C.2Ethernet cable to PC communication
The Ethernet port IP address, subnet mask, and gateway address are
software-configurable. In addition, a meter can be configured to act as a
DHCP (Dynamic Host Configuration Protocol) server to assign an IP address
to a PC or laptop running MeterLink. The DHCP server facility is not intended
to act as a general purpose DHCP server for a wider network. To this end, no
user control is provided over the class or range of IP addresses the unit
provides. A standard twisted pair (Cat-5) cable should be used for Ethernet
wiring.
It is strongly recommended that the meter be configured using an
independent (off-network) single host. After configuration of the 3810
Series Liquid Ultrasonic Flow Meter, the DHCP option must be turned off if
used on a LAN/WAN.
LED status
• Red flashing LED
• Solid red the
Acquisition Module is
not communicating
with the CPU Module
• Green flashing LED
Flashing green (when
receiving data)
Flashing green (when
transmitting data)
Solid green
54 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
NOTICE
RESTRICTED ETHERNET AND SERIAL CONNECTIVITY USAGE
Failure to restrict Ethernet and communication access to the 3810 Series
Liquid Ultrasonic Flow Meter can result in, among other things, unauthorized
access, system corruption, and/or data loss.
User is responsible for ensuring that physical access and Ethernet or
electronic access to the 3810 Series Liquid Ultrasonic Flow Meter is
appropriately controlled and any necessary security precautions are
implemented; such as, establishing a firewall, setting password permissions
and/or implementing security levels.
Table C-2: Ethernet Communication
Ethernet
Wire colorCPU/EXP
White with green StripeTX+
Solid greenTX-
White with orange stripeRX+
Solid orange
Note
Wiring colors for TX+/TXand RX+/RX- can be
switched as ethernet ports
will automatically detect
crossover vs. straight
connection. Connections
shown are straight
through cable.
RX-
Ethernet Communication
Use ethernet cable, to connect the PC to the meter.
Upgrade kit instructions55
Upgrade kit instructionsJune 2022
A DIN 41612 48-pin connector is the interface from the CPU Module to the
Backplane (male end located on the back of the Backplane Board).
C.3Input and output connections
The Rosemount 3810 Series Ultrasonic Flow Meter provides the Analog
inputs for pressure and temperature, Analog output 2 and frequency and
digital outputs on the CPU Module lower terminal block.
56 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure C-2: CPU Module Lower Terminal Block I/O Connections
A. Frequency/Digital output 2 (FODO 2)
B. Frequency/Digital output 2 (FODO 2) Gnd
C. Frequency/Digital output 2 (FODO 2) Gnd
D. Frequency/Digital output 3 (FODO 3)
E. Analog output 2 + (4-20mA output)
F. Analog output 2 - (4-20mA output)
G. Analog in (Temperature) +
H. Analog in (Temperature) -
I. Analog in (Pressure) +
J. Analog in (Pressure) -
Possible configurations for Frequency and Digital Outputs are shown in the
following figure.
Upgrade kit instructions57
Upgrade kit instructionsJune 2022
Figure C-3: Frequency/Digital Output
Output for FODO1 and Digital Output1 (Group 1 on the CPU Module upper
terminal block) share a common ground and have 50V isolation. FODO2 and
FODO3 (Group 2 on the CPU Module lower terminal block) share a common
ground and have 50V isolation. This allows an output to be connected to a
different flow computer. The outputs are opto-isolated from the CPU
Module and have a withstand voltage of at least 500V rms dielectric.
58 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Figure C-4: CPU Module - Frequency/Digital Outputs Common Ground Type 2
A. FODO1 and Digital input1 - shared common ground (Group1)
B. FODO2 and FODO3 - shared common ground (Group2)
Upgrade kit instructions59
Upgrade kit instructionsJune 2022
Figure C-5: CPU Module - Frequency/Digital Outputs Common Ground Type 4
A. FODO1 and DI1/FODO6 - shared common ground - Type 4 CPU Module
(Group 1)
B. FODO2, FODO3, FODO4 and FODO5 - shared common ground - Type 4
CPU Module (Group 2)
C.4
60 3810 Series Electronics Upgrade kit instructions
Serial communications
Use a serial cable, to connect to a PC running MeterLink™. The cable is
designed for RS-232 communications which is the serial Port A default
configuration (see Appendix D Systems Wiring Diagram, Drawing DMC -
004936).
The DB-9 end of the cable plugs directly into the PC running MeterLink. The
three wires on the other end of the cable connect to the CPU Module
RS-485/RS-232 terminals. The RED wire goes to RX, the WHITE wire goes to
TX, and the BLACK wire goes to COM (see Table 3-5 for Port A wiring).
RS-485, 2-wire connection on Port A, uses TX+ and TX- on the CPU Module
and has a ground wire.
When Belden wire No. 9940 or equivalent is used, the maximum cable
length for RS-232 communications at 9600 bps is 88.3 meters (250 ft.) and
the maximum cable length for RS-485 communication at 57600 bps is 600
meters (1970 ft.).
June 2022Upgrade kit instructions
Port A supports a special override mode which forces the port to use known
communication values (19200 baud, address 32, RS-232). Note that the
protocol is auto-detected. This mode is expected to be used during meter
commissioning (to establish initial communication) and in the event that the
user cannot communicate with the meter (possibly due to an inadvertent
communication configuration change). Alternately, when using MeterLink
with an Ethernet port, use Ethernet cable, to connect the PC.
Table C-3: Serial Port Parameters
Port/communicationDescriptionCommon features
• Port A (Standard)
• RS-232
• RS-485 Half Duplex
• RS-485 ( 2-wire
communication on
(1)
Port A.)
• Typically used for
general
communications with
a flow computer, RTU
(Modbus slave) and
radios.
• RS-485 - 2-wire (Half
Duplex) connected to
TX + and TX -
• Special override mode
to force port
configuration to
known settings.
• Supports RTS/CTS
handshaking with
software-configurable
RTS on/off delay
times.
• Factory default is
RS-232, Address 32,
19200 baud.
• Communications via
MeterLink using
RS-232 or RS-485 Full
Duplex
• Software configurable
Modbus Address
(1-247)
• Auto-detects TCP/IP
and ASCII or RTU
Protocol
• ASCII Protocol:
— Start Bits = 1, Data
Bits = 7
(2)
— Parity: odd or
even 1, Stop Bits =
(3)
1
— Baud Rates: 1200,
2400, 9600,
19200, 38400,
57600, 115000
bps
—
• RTU Protocol: Start
Bits = 1, Data Bits =
(4)
8
— Parity: none, Stop
Bits = 1
(5)
— Baud Rates: 1200,
2400, 9600,
19200, 38400,
57600, 115000
bps
Upgrade kit instructions61
Upgrade kit instructionsJune 2022
Table C-3: Serial Port Parameters (continued)
Port/communicationDescriptionCommon features
EthernetPreferred port for
diagnostic
communication via
MeterLink
10 Mbps/100 Mbps
(1) RS-485 2-wire connections use TX+ and TX - on the CPU Module
(2) Denotes auto-detected protocols
(3) Denotes auto-detected protocols
(4) Denotes auto-detected protocols
(5) Denotes auto-detected protocols
Modbus TCP/IP, Modbus
TCP
NOTICE
If not using Ethernet, a full duplex serial connection is necessary for
MeterLink to communicate with a Rosemount 3810Series Ultrasonic Flow
Meter.
Figure C-6: PC to Meter Serial Connection Wiring
C.5Analog input settings
The Rosemount 3810 Series Ultrasonic Flow Meter has the capability to
sample analog temperature (Analog Input 1) and pressure (Analog Input 2)
with 4-20 mA signals. These analog input signals are configured to sink. The
two independent analog input circuits are configured for conventional 4-20
mA service. Also, 24VDC isolated power supply connection is provided for an
external power source. Refer to the System Wiring Diagram in 3810 Series
engineering drawings.
62 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
C.6Analog output settings
The Rosemount 3810 Series Ultrasonic Flow Meter provides two 4-20 mA
analog output signals that are software configurable for either sink or source
current. Refer to the System Wiring Diagram in Appendix D.
Full HART® functionality is provided so that any commercially available HART
transmitter which meets the specifications of the HART Communications
Foundation can be connected to a Rosemount 3810 Series Ultrasonic Flow
Meter.
C.7Digital Input
The Rosemount 3810 Series Ultrasonic Flow Meter provides one digital input
that can be used as a general purpose input. The digital input must be
configured via the MeterLink™ Tools|Edit/Compare
Configuration screen.
C.8External power source connection and fuse
Located on the CPU Module are connections for a user-provided external
power source, a 2 Amp fuse and a 24V loop power connection for ultrasonic
meter analog outputs, temperature transmitter or pressure transmitter
devices. The current is limited to 88mA.
Upgrade kit instructions63
Upgrade kit instructionsJune 2022
Figure C-7: CPU Module Power Source Connections
A. 24V Loop power
B. Power in connector (main power source)
C. 2 Amp fuse (used for main power input)
64 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Upgrade kit instructions65
Upgrade kit instructionsJune 2022
D3810 Series engineering drawings
DMC-0049363810 Series Ultrasonic Meter System
Wiring Diagram
66 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Upgrade kit instructions67
Upgrade kit instructionsJune 2022
68 3810 Series Electronics Upgrade kit instructions
June 2022Upgrade kit instructions
Upgrade kit instructions69
Upgrade kit instructionsJune 2022
70 3810 Series Electronics Upgrade kit instructions
Emerson Terms and Conditions of Sale are
available upon request. The Emerson logo
is a trademark and service mark of
Emerson Electric Co. Rosemount is a mark
of one of the Emerson family of
companies. All other marks are the
property of their respective owners.
Emerson.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.